Search NASA⌕ Search

SEARCH · Search NASA

Results for “simulator study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Development of Airport Surface Required Navigation Performance (RNP)

The U.S. and international aviation communities have adopted the Required Navigation Performance (RNP) process for defining aircraft performance when operating the en-route, approach and landing phases of flight. RNP consists primarily of the following key parameters - accuracy, integrity, continuity, and availability. The processes and analytical techniques employed to define en-route, approach and landing RNP have been applied in the development of RNP for the airport surface. To validate the proposed RNP requirements several methods were used. Operational and flight demonstration data were analyzed for conformance with proposed requirements, as were several aircraft flight simulation studies. The pilot failure risk component was analyzed through several hypothetical scenarios. Additional simulator studies are recommended to better quantify crew reactions to failures as well as additional simulator and field testing to validate achieved accuracy performance, This research was performed in support of the NASA Low Visibility Landing and Surface Operations Programs.

Cassell, Rick↗

Void growth via dislocation pileup impingement on grain boundary

In this work, the effect of edge dislocations, impinging on grain boundary in fcc Fe near a preexisting void on the volume of this void, was studied using MD simulation. It was found that virtually unlimited growth of the void via this mechanism is possible under certain conditions. To the best of our knowledge this is the first atomistic simulation study, demonstrating feasibility of this void growth mechanism.

36 MATERIALS SCIENCE↗

A Monte Carlo investigation of Swank noise for thick, segmented, crystalline scintillators for radiotherapy imaging

Thick, segmented scintillating detectors, consisting of 2D matrices of scintillator crystals separated by optically opaque septal walls, hold considerable potential for significantly improving the performance of megavoltage (MV) active matrix, flat-panel imagers (AMFPIs). Initial simulation studies of the radiation transport properties of segmented detectors have indicated the possibility of significant improvement in DQE compared to conventional MV AMFPIs based on phosphor screen detectors. It is therefore interesting to investigate how the generation and transport of secondary optical photons affect the DQE performance of such segmented detectors. One effect that can degrade DQE performance is optical Swank noise (quantified by the optical Swank factor I{sub opt}), which is induced by depth-dependent variations in optical gain. In this study, Monte Carlo simulations of radiation and optical transport have been used to examine I{sub opt} and zero-frequency DQE for segmented CsI:Tl and BGO detectors at different thicknesses and element-to-element pitches. For these detectors, I{sub opt} and DQE were studied as a function of various optical parameters, including absorption and scattering in the scintillator, absorption at the top reflector and septal walls, as well as scattering at the side surfaces of the scintillator crystals. The results indicate that I{sub opt} and DQE are only weakly affected by absorption and scattering in the scintillator, as well as by absorption at the top reflector. However, in some cases, these metrics were found to be significantly degraded by absorption at the septal walls and scattering at the scintillator side surfaces. Moreover, such degradations are more significant for detectors with greater thickness or smaller element pitch. At 1.016 mm pitch and with optimized optical properties, 40 mm thick segmented CsI:Tl and BGO detectors are predicted to provide DQE values of {approx}29% and 42%, corresponding to improvement by factors of {approx}29 and 42, respectively, compared to that of conventional MV AMFPIs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A dual-view digital tomosynthesis imaging technique for improved chest imaging

Purpose: Digital tomosynthesis (DTS) has been shown to be useful for reducing the overlapping of abnormalities with anatomical structures at various depth levels along the posterior–anterior (PA) direction in chest radiography. However, DTS provides crude three-dimensional (3D) images that have poor resolution in the lateral view and can only be displayed with reasonable quality in the PA view. Furthermore, the spillover of high-contrast objects from off-fulcrum planes generates artifacts that may impede the diagnostic use of the DTS images. In this paper, the authors describe and demonstrate the use of a dual-view DTS technique to improve the accuracy of the reconstructed volume image data for more accurate rendition of the anatomy and slice images with improved resolution and reduced artifacts, thus allowing the 3D image data to be viewed in views other than the PA view. Methods: With the dual-view DTS technique, limited angle scans are performed and projection images are acquired in two orthogonal views: PA and lateral. The dual-view projection data are used together to reconstruct 3D images using the maximum likelihood expectation maximization iterative algorithm. In this study, projection images were simulated or experimentally acquired over 360° using the scanning geometry for cone beam computed tomography (CBCT). While all projections were used to reconstruct CBCT images, selected projections were extracted and used to reconstruct single- and dual-view DTS images for comparison with the CBCT images. For realistic demonstration and comparison, a digital chest phantom derived from clinical CT images was used for the simulation study. An anthropomorphic chest phantom was imaged for the experimental study. The resultant dual-view DTS images were visually compared with the single-view DTS images and CBCT images for the presence of image artifacts and accuracy of CT numbers and anatomy and quantitatively compared with root-mean-square-deviation (RMSD) values computed using the digital chest phantom or the CBCT images as the reference in the simulation and experimental study, respectively. High-contrast wires with vertical, oblique, and horizontal orientations in a PA view plane were also imaged to investigate the spatial resolutions and how the wire signals spread in the PA view and lateral view slice images. Results: Both the digital phantom images (simulated) and the anthropomorphic phantom images (experimentally generated) demonstrated that the dual-view DTS technique resulted in improved spatial resolution in the depth (PA) direction, more accurate representation of the anatomy, and significantly reduced artifacts. The RMSD values corroborate well with visual observations with substantially lower RMSD values measured for the dual-view DTS images as compared to those measured for the single-view DTS images. The imaging experiment with the high-contrast wires shows that while the vertical and oblique wires could be resolved in the lateral view in both single- and dual-view DTS images, the horizontal wire could only be resolved in the dual-view DTS images. This indicates that with single-view DTS, the wire signals spread liberally to off-fulcrum planes and generated wire shadow there. Conclusions: The authors have demonstrated both visually and quantitatively that the dual-view DTS technique can be used to achieve more accurate rendition of the anatomy and to obtain slice images with improved resolution and reduced artifacts as compared to the single-view DTS technique, thus allowing the 3D image data to be viewed in views other than the PA view. These advantages could make the dual-view DTS technique useful in situations where better separation of the objects-of-interest from the off-fulcrum structures or more accurate 3D rendition of the anatomy are required while a regular CT examination is undesirable due to radiation dose considerations.

60 APPLIED LIFE SCIENCES↗

Gate Control Coefficient Effect on CNFET Characteristic

The development of carbon nanotube field-effect transistor (CNFET) as alternative to existing transistor technology has long been published and discussed. The emergence of this device offers new material and structure in building a transistor. This paper intends to do an analysis of gate control coefficient effect on CNFET performance. The analysis is based on simulation study of current-voltage (I-V) characteristic of ballistic CNFET. The simulation study used the MOSFET-like CNFET mathematical model to establish the device output characteristic. Based on the analysis of simulation result, it is found that the gate control coefficient contributes to a significant effect on the performance of CNFET. The result also shown the parameter could help to improve the device performance in terms of its output and response as well. Nevertheless, the characteristic of the carbon nanotube that acts as the channel is totally important in determining the performance of the transistor as a whole.

36 MATERIALS SCIENCE↗

Systematic study of target localization for bioluminescence tomography guided radiation therapy

Purpose: To overcome the limitation of CT/cone-beam CT (CBCT) in guiding radiation for soft tissue targets, the authors developed a spectrally resolved bioluminescence tomography (BLT) system for the small animal radiation research platform. The authors systematically assessed the performance of the BLT system in terms of target localization and the ability to resolve two neighboring sources in simulations, tissue-mimicking phantom, and in vivo environments. Methods: Multispectral measurements acquired in a single projection were used for the BLT reconstruction. The incomplete variables truncated conjugate gradient algorithm with an iterative permissible region shrinking strategy was employed as the optimization scheme to reconstruct source distributions. Simulation studies were conducted for single spherical sources with sizes from 0.5 to 3 mm radius at depth of 3–12 mm. The same configuration was also applied for the double source simulation with source separations varying from 3 to 9 mm. Experiments were performed in a standalone BLT/CBCT system. Two self-illuminated sources with 3 and 4.7 mm separations placed inside a tissue-mimicking phantom were chosen as the test cases. Live mice implanted with single-source at 6 and 9 mm depth, two sources at 3 and 5 mm separation at depth of 5 mm, or three sources in the abdomen were also used to illustrate the localization capability of the BLT system for multiple targets in vivo. Results: For simulation study, approximate 1 mm accuracy can be achieved at localizing center of mass (CoM) for single-source and grouped CoM for double source cases. For the case of 1.5 mm radius source, a common tumor size used in preclinical study, their simulation shows that for all the source separations considered, except for the 3 mm separation at 9 and 12 mm depth, the two neighboring sources can be resolved at depths from 3 to 12 mm. Phantom experiments illustrated that 2D bioluminescence imaging failed to distinguish two sources, but BLT can provide 3D source localization with approximately 1 mm accuracy. The in vivo results are encouraging that 1 and 1.7 mm accuracy can be attained for the single-source case at 6 and 9 mm depth, respectively. For the 2 sources in vivo study, both sources can be distinguished at 3 and 5 mm separations, and approximately 1 mm localization accuracy can also be achieved. Conclusions: This study demonstrated that their multispectral BLT/CBCT system could be potentially applied to localize and resolve multiple sources at wide range of source sizes, depths, and separations. The average accuracy of localizing CoM for single-source and grouped CoM for double sources is approximately 1 mm except deep-seated target. The information provided in this study can be instructive to devise treatment margins for BLT-guided irradiation. These results also suggest that the 3D BLT system could guide radiation for the situation with multiple targets, such as metastatic tumor models.

60 APPLIED LIFE SCIENCES↗

Study of an Automatic System for Control of the Terminal Phase of Satellite Rendezvous

An analytical and simulation study has been conducted of an automatic system for control of the terminal phase of rendezvous between two space vehicles. The basic system employs switching and thrust orientation criteria based upon relative-motion parameters first to establish a collision course and then to reduce the range and range rate to zero, simultaneously. In addition, a technique has been devised by which the system effects control based upon the total amount of fuel available for this phase of the space mission. The onboard equipment assumed for the intercepting vehicle includes a special-purpose computer, an attitude-control system, a single main rocket engine with, multi-start capabilities, and sensors capable of measuring range, line-of sight angles, and the time derivatives of these quantities. Techniques are developed. for employing control with either modulated thrust or on-off thrust at a constant level. The results of an analog simulation study of the automatic control system in which a six-degree-of freedom vehicle is assumed are presented for various initial conditions at the beginning of the terminal phase. The results of the study indicate that the automatic system can effectively control the terminal phase of rendezvous over a wide range of initial conditions and control-system requirements and, in addition, can utilize the available fuel in a very efficient manner.

RENDEZVOUS↗

Translational and Rotational Motion of C8 Aromatics Adsorbed in Isotropic Porous Media (MOF-5): NMR Studies and MD Simulations

For this, we combined nuclear magnetic resonance (NMR) and molecular dynamics (MD) simulation to study xylene behavior in MOF-5, probing the effects of adsorbate geometry in a weakly interacting model isotropic metal organic framework (MOF) system. We employed NMR diffusometry and relaxometry techniques at low field (13 MHz) to quantify the self-diffusion coefficients (D s ) and the longitudinal relaxation times (T 1 ) of xylenes in MOF-5 as a function of temperature at the saturated loading for each xylene. These experiments reveal the translational motion activation energies to be 15.3, 19.7, and 21.2 kj mol -1 and the rotational activation energies to be 47.26, 12.88, and 11.55 for the (p-, m-, o-) xylene isomers, respectively. Paraxylene exhibits faster translational motion, yet shows four times the activation energy barrier for rotational motion vis-à-vis the other isomers. MD simulations performed on these model systems corroborate the findings for paraxylene and suggest that paraxylene has the lower free energy barrier for hopping away from its binding sites, yet has the slowest rotational motion in the plane of the xylene molecule.

36 MATERIALS SCIENCE↗

A digital computer simulation and study of a direct-energy-transfer power-conditioning system

An investigation of the behavior of the power-conditioning system as a whole is a necessity to ensure the integrity of the aggregate system in the case of space applications. An approach for conducting such an investigation is considered. A description is given of the application of a general digital analog simulator program to the study of an aggregate power-conditioning system which is being developed for use on the International Ultraviolet Explorer spacecraft. The function of the direct energy transfer system studied involves a coupling of a solar array through a main distribution bus to the spacecraft electrical loads.

Burns, W. W., III↗

A parameter sensitivity study for simulating DNA damage after proton irradiation using TOPAS-nBio

Monte Carlo (MC) track structure simulation tools are commonly used for predicting radiation induced DNA damage by modeling the physical and chemical reactions at the nanometer scale. However, the outcome of these MC simulations is particularly sensitive to the adopted parameters which vary significantly across studies. In this study, a previously developed full model of nuclear DNA was used to describe the DNA geometry. The TOPAS-nBio MC toolkit was used to investigate the impact of physics and chemistry models as well as three key parameters (the energy threshold for direct damage, the chemical stage time length, and the probability of damage between hydroxyl radical reactions with DNA) on the induction of DNA damage. Our results show that the difference in physics and chemistry models alone can cause differences up to 34% and 16% in the DNA double strand break (DSB) yield, respectively. Additionally, changing the direct damage threshold, chemical stage length, and hydroxyl damage probability can cause differences of up to 28%, 51%, and 71% in predicted DSB yields, respectively, for the configurations in this study.

60 APPLIED LIFE SCIENCES↗

Cardiovascular responses to hypogravic environments

The cardiovascular deconditioning observed during and after space flight is characterized in a review of human space and simulation studies and animal simulations. The various simulation techniques (horizontal bed rest, head-down tilt, and water immersion in man, and immobilization of animals) are examined, and sample results are presented in graphs. Countermeasures such as exercise regimens, fluid replacement, drugs, venous pooling, G-suits, oscillating beds, electrostimulation of muscles, lower-body negative pressure, body-surface cooling, and hypoxia are reviewed and found to be generally ineffective or unreliable. The need for future space experimentation in both humans and animals is indicated.

Sandler, H.↗

Aerosol measurement program strategy for global aerosol backscatter model development

The purpose was to propose a balanced program of aerosol backscatter research leading to the development of a global model of aerosol backscatter. Such a model is needed for feasibility studies and systems simulation studies for NASA's prospective satellite-based Doppler lidar wind measurement system. Systems of this kind measure the Doppler shift in the backscatter return from small atmospheric aerosol wind tracers (of order 1 micrometer diameter). The accuracy of the derived local wind estimates and the degree of global wind coverage for such a system are limited by the local availability and by the global scale distribution of natural aerosol particles. The discussions here refer primarily to backscatter model requirements at CO2 wavelengths, which have been selected for most of the Doppler lidar systems studies to date. Model requirements for other potential wavelengths would be similar.

Bowdle, David A.↗

Interpretation of lidar and satellite data sets using a global photochemical model

The status in the beginning of the report period was that the existing General Circulation Model (GCM) was running with a chemistry module compiled for stratospheric simulation studies. The chemistry simulation was not working sufficiently in the troposphere and any tropospheric trace gas sources or dry deposition sinks were not yet incorporated. The current status concerning the chemistry module is that the chemistry simulation has been modified to also simulate the chemistry in the troposphere with resulting mixing ratios close to other model simulations as described in Olson et al. (1996). The mechanism to incorporate trace gas source and dry deposition sinks, testing for H202, CH300H, 03, HCHO, HN03, and N02, are incorporated and is currently being tested. Existing model and development versions include: the full GCM model, currently still running with the original stratospheric chemistry module; an off-line version of the GCM, i.e. wind and photolysis rates are pre-calculated and prescribed in read-in arrays; a box model version of the modified chemistry module for developments and first tests of new modifications; and a box model with the same chemistry simulated but flexible partitioning and integration methods for test purposes of those. The grantee's work focused mainly on three areas: trace gas sources and dry deposition; method to introduce a NO source instead of a NO(x) source; and investigating integration methods.

Chyba, Thomas↗

Simulation Framework to Estimate the Performance of CO2 and O2 Sensing from Space and Airborne Platforms for the ASCENDS Mission Requirements Analysis

The Active Sensing of CO2 Emissions over Nights Days and Seasons (ASCENDS) mission recommended by the NRC Decadal Survey has a desired accuracy of 0.3% in carbon dioxide mixing ratio (XCO2) retrievals requiring careful selection and optimization of the instrument parameters. NASA Langley Research Center (LaRC) is investigating 1.57 micron carbon dioxide as well as the 1.26-1.27 micron oxygen bands for our proposed ASCENDS mission requirements investigation. Simulation studies are underway for these bands to select optimum instrument parameters. The simulations are based on a multi-wavelength lidar modeling framework being developed at NASA LaRC to predict the performance of CO2 and O2 sensing from space and airborne platforms. The modeling framework consists of a lidar simulation module and a line-by-line calculation component with interchangeable lineshape routines to test the performance of alternative lineshape models in the simulations. As an option the line-by-line radiative transfer model (LBLRTM) program may also be used for line-by-line calculations. The modeling framework is being used to perform error analysis, establish optimum measurement wavelengths as well as to identify the best lineshape models to be used in CO2 and O2 retrievals. Several additional programs for HITRAN database management and related simulations are planned to be included in the framework. The description of the modeling framework with selected results of the simulation studies for CO2 and O2 sensing is presented in this paper.

Plitau, Denis↗

Fermilab Booster Transition Crossing Simulations and Beam Studies

The Fermilab Booster accelerates beam from 400 MeV to 8 GeV at 15 Hz. In the PIP (Proton Improvement Plan) era, it is required that Booster deliver 4.2 x $10^{12}$ protons per pulse to extraction. One of the obstacles for providing quality beam to the users is the longitudinal quadrupole oscillation that the beam suffers from right after transition. Although this oscillation is well taken care of with quadrupole dampers, it is important to understand the source of these oscillations in light of the PIP II requirements that require 6.5 x $10^{12}$ protons per pulse at extraction. This paper explores the results from machine studies, computer simulations and solutions to prevent the quadrupole oscillations after transition.

Bhat, C. M.↗

Electron heating during magnetic reconnection: A simulation scaling study

Electron bulk heating during magnetic reconnection with symmetric inflow conditions is examined using kinetic particle-in-cell simulations. Inflowing plasma parameters are varied over a wide range of conditions, and the increase in electron temperature is measured in the exhaust well downstream of the x-line. The degree of electron heating is well correlated with the inflowing Alfvén speed c{sub Ar} based on the reconnecting magnetic field through the relation ΔT{sub e}=0.033 m{sub i} c{sub Ar}{sup 2}, where ΔT{sub e} is the increase in electron temperature. For the range of simulations performed, the heating shows almost no correlation with inflow total temperature T{sub tot}=T{sub i}+T{sub e} or plasma β. An out-of-plane (guide) magnetic field of similar magnitude to the reconnecting field does not affect the total heating, but it does quench perpendicular heating, with almost all heating being in the parallel direction. These results are qualitatively consistent with a recent statistical survey of electron heating in the dayside magnetopause (Phan et al., Geophys. Res. Lett. 40, 4475, 2013), which also found that ΔT{sub e} was proportional to the inflowing Alfvén speed. The net electron heating varies very little with distance downstream of the x-line. The simulations show at most a very weak dependence of electron heating on the ion to electron mass ratio. In the antiparallel reconnection case, the largely parallel heating is eventually isotropized downstream due a scattering mechanism, such as stochastic particle motion or instabilities. The simulation size is large enough to be directly relevant to reconnection in the Earth's magnetosphere, and the present findings may prove to be universal in nature with applications to the solar wind, the solar corona, and other astrophysical plasmas. The study highlights key properties that must be satisfied by an electron heating mechanism: (1) preferential heating in the parallel direction; (2) heating proportional to m{sub i} c{sub Ar}{sup 2}; (3) at most a weak dependence on electron mass; and (4) an exhaust electron temperature that varies little with distance from the x-line.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Atmospheric Modeling And Sensor Simulation (AMASS) study

A 4800 band synchronous communications link was established between the Perkin-Elmer (P-E) 3250 Atmospheric Modeling and Sensor Simulation (AMASS) system and the Cyber 205 located at the Goddard Space Flight Center. An extension study of off-the-shelf array processors offering standard interface to the Perkin-Elmer was conducted to determine which would meet computational requirements of the division. A Floating Point Systems AP-120B was borrowed from another Marshall Space Flight Center laboratory for evaluation. It was determined that available array processors did not offer significantly more capabilities than the borrowed unit, although at least three other vendors indicated that standard Perkin-Elmer interfaces would be marketed in the future. Therefore, the recommendation was made to continue to utilize the 120B ad to keep monitoring the AP market. Hardware necessary to support requirements of the ASD as well as to enhance system performance was specified and procured. Filters were implemented on the Harris/McIDAS system including two-dimensional lowpass, gradient, Laplacian, and bicubic interpolation routines.

Parker, K. G.↗

Development of a Neural Network Simulator for Studying the Constitutive Behavior of Structural Composite Materials

This paper introduces a recent development and application of a noncommercial artificial neural network (ANN) simulator with graphical user interface (GUI) to assist in rapid data modeling and analysis in the engineering diffraction field. The real-time network training/simulation monitoring tool has been customized for the study of constitutive behavior of engineering materials, and it has improved data mining and forecasting capabilities of neural networks. This software has been used to train and simulate the finite element modeling (FEM) data for a fiber composite system, both forward and inverse. The forward neural network simulation precisely reduplicates FEM results several orders of magnitude faster than the slow original FEM. The inverse simulation is more challenging; yet, material parameters can be meaningfully determined with the aid of parameter sensitivity information. The simulator GUI also reveals that output node size for materials parameter and input normalization method for strain data are critical train conditions in inverse network. The successful use of ANN modeling and simulator GUI has been validated through engineering neutron diffraction experimental data by determining constitutive laws of the real fiber composite materials via a mathematically rigorous and physically meaningful parameter search process, once the networks are successfully trained from the FEM database.

Na, Hyuntae↗