Search NASA⌕ Search

SEARCH · Search NASA

Results for “single photon source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Importance of bulk excitations and coherent electron-photon-phonon scattering in photoemission from PbTe(111): Ab initio theory with experimental comparisons

This paper presents a fully ab initio many-body photoemission framework that includes coherent three-body electron-photon-phonon scattering to predict the transverse momentum distributions and the mean transverse energies (MTEs) of bulk photoelectrons from single-crystal photocathodes. The need to develop such a theory stems from the lack of studies that provide complete understanding of the underlying fundamental processes governing the transverse momentum distribution of photoelectrons emitted from single crystals. For example, initial predictions based on density-functional theory calculations of effective electron masses suggested that the (111) surface of PbTe would produce very small MTEs (≤ 15 meV), whereas our experiments yielded MTEs ten to twenty times larger than these predictions and also exhibited a lower photoemission threshold than predicted. The ab initio framework presented in this paper correctly reproduces both the magnitude of the MTEs from our measurements in PbTe(111) and the observed photoemission below the predicted threshold. Our results show that both photoexcitations into states that propagate in the bulk of the material and coherent many-body electron-photon-phonon scattering processes, which initial predictions ignored, play surprisingly important roles in photoemission from PbTe(111). Lastly, from the lessons learned, we recommend a procedure for rapid computational screening of potential single-crystal photocathodes for applications in next-generation ultrafast electron diffraction and X-ray free-electron lasers, which will enable significant advances in condensed matter research.

36 MATERIALS SCIENCE↗

Bell Inequality Experiment for a High Brightness Time-Energy Entangled Source

A periodically poled MgO doped LiNbO3 (MgO:LN) non-degenerate photon pair source is utilized for spontaneous parametric down-conversion of 532 nm photons into time-energy entangled pairs of 800 and 1600 nm photons. The entangled photons are separated using previously detailed sorting optics, such that each wavelength is independently directed through one of two modified Mach-Zehnder interferometers also known as a Franson interferometer after which they are fiber-optically guided to high-efficiency photon detectors. Output from the detectors is sent to a high resolution time tagger, where coincidences between the entangled photons are recorded. By varying the length of the long path in one Mach-Zehnder interferometer, it is possible to observe high visibility sinusoidal fringes in the measured coincidence rates (while no variation is seen in single photon detection rates). These fringes due to interference between the photon probability amplitudes are indicative of a violation of the Bell inequality, and confirm inconsistencies with local hidden variable theory for the correlations of the time-energy entangled photon pairs.

time-energy entanglement↗

Bell Inequality Experiment for a High Brightness Time-Energy Entangled Source

A periodically poled MgO - doped LiNbO3 (MgO:LN) non-degenerate photon pair source is utilized for spontaneous parametric down-conversion of 532-nanometer photons into time-energy entangled pairs of 800- and 1600-nanometer photons. The entangled photons are separated using previously detailed sorting optics, such that each wavelength is independently directed through one of two modified Mach-Zehnder interferometers - also known as a Franson interferometer - after which they are fiber-optically guided to high-efficiency photon detectors. Output from the detectors is sent to a high resolution time tagger, where coincidences between the entangled photons are recorded. By varying the length of the long path in one Mach-Zehnder interferometer, it is possible to observe high visibility sinusoidal fringes in the measured coincidence rates (while no variation is seen in single photon detection rates). These fringes - due to interference between the photon probability amplitudes - are indicative of a violation of the Bell inequality, and confirm inconsistencies with local hidden variable theory for the correlations of the time-energy entangled photon pairs.

Time-Energy Entanglement↗

Mid-IR interferometric nulling for TPF

By the middle of 2006, the Interferometry Technology development program for NASA’s Terrestrial Planet Finder (TPF) Mission has the goal of demonstrating deep and stable interferometric nulling of broadband Mid-IR thermal radiation under conditions that are traceable to the expected on-orbit conditions. Specifically, the task is to demonstrate null levels of 10 to the negative 6 power, with a 50% BW centered at 10 um, with null stabilities of 10 to the negative 7 power all at cryogenic temperatures for observational periods of a couple of hours. The Achromatic Nulling activity at JPL addresses this concern in two testbeds: the warm nulling testbed and the cryonulling testbed. The warm nulling testbed will demonstrate the physics of nulling broadband thermal sources in an environment that is conducive to efficient research. We’ll explore nulling techniques, optical-mechanical alignment methods, motion control, and path-length metrology for a single beam interferometer, as well as preliminary planet detection techniques. Ultimate nulling capabilities under conditions that are more flight-like will be demonstrated in cryogenic nulling testbed. Knowledge gained from operation at room temperature will be applied to the cryongenic experiment where we face the additional challenges of extreme temperatures, cryongenic actuators, component survivability and fluxes that are within an order of magnitude of expected flux levels on orbit. Concurrently, we will develop a low flux mid-IR camera that will allow us to measure the nulls at these faint photon fluxes. This talk will review this development activity and will include recent nulling experimental results and plans for future work.

Vasisht, Gautam↗

Synthetic and Mechanistic Implications of Chlorine Photoelimination in Nickel/Photoredox C(sp 3 )–H Cross-Coupling

In recent years, the development of light-driven reactions has contributed numerous advances in synthetic organic chemistry. A particularly active research area combines photoredox catalysis with nickel catalysis to accomplish otherwise inaccessible cross-coupling reactions. In these reactions, the photoredox catalyst absorbs light to generate an electronically excited charge-transfer state that can engage in electron or energy transfer with a substrate and the nickel catalyst. Our group questioned whether photoinduced activation of the nickel catalyst itself could also contribute new approaches to cross-coupling. Over the past 5 years, we have sought to advance this hypothesis for the development of a suite of mild and site-selective C(sp 3 )–H cross-coupling reactions with chloride-containing coupling partners via photoelimination of a Ni–Cl bond. On the basis of a report from the Nocera laboratory, we reasoned that photolysis of a Ni(III) aryl chloride species, generated by single-electron oxidation of a typical Ni(II) intermediate in cross-coupling, might allow for the catalytic generation of chlorine atoms. Combining this with the ability of Ni(II) to accept alkyl radicals, we hypothesized that photocatalytically generated chlorine atoms could mediate hydrogen atom transfer (HAT) with C(sp 3 )–H bonds to generate a substrate-derived alkyl radical that is captured by the Ni center in cross-coupling. A photoredox catalyst was envisioned to promote the necessary single-electron oxidation and reduction of the Ni catalyst to facilitate an overall redox-neutral process. Overall, this strategy would offer a visible-light-driven mechanism for chlorine radical formation enabled by the sequential capture of two photons. As an initial demonstration, we developed a Ni/photoredox-catalyzed α-oxy C(sp 3 )–H arylation of cyclic and acyclic ethers. This method was extended to a mild formylation of abundant and complex aryl chlorides through selective 2-functionalization of 1,3-dioxolane. Seeking to develop a suite of reactions that introduce carbon at all different oxidation states, we explored C(sp 3 )–H cross-coupling with trimethyl orthoformate, a common laboratory solvent. We found that trimethyl orthoformate serves as a source of methyl radical for a methylation reaction via β-scission from a tertiary radical generated upon chlorine-mediated HAT. Since chlorine radical is capable of abstracting unactivated C(sp 3 )–H bonds, our efforts have also been directed at cross-coupling with a range of feedstock chemicals, such as alkanes and toluenes, along with late-stage intermediates, using chloroformates as coupling partners. Overall, this platform enables access to valuable synthetic transformations with (hetero)aryl chlorides, which despite being the most ubiquitous and inexpensive aryl halide coupling partners, are rarely reactive in Ni/photoredox catalysis. Little is known about the photophysics and photochemistry of organometallic Ni complexes relevant to cross-coupling. We have conducted mechanistic investigations, including computational, spectroscopic, emission quenching, and stoichiometric oxidation studies, of Ni(II) aryl halide complexes common to Ni/photoredox reactions. These studies indicate that chlorine radical generation from excited Ni(III) is operative in the described C(sp 3 )–H functionalization methods. More generally, the studies illustrate that the photochemistry of cross-coupling catalysts cannot be ignored in metallaphotoredox reactions. We anticipate that further mechanistic understanding should facilitate catalyst design and lead to the development of new synthetic methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of 128 × 128 MM-PAD-2.1 ASIC: a fast framing hard x-ray detector with high dynamic range

Here, we characterize a new x-ray Mixed-Mode Pixel Array Detector (MM-PAD-2.1) Application Specific Integrated Circuit (ASIC). Using an integrating pixel front-end with dynamic charge removal architecture, the MM-PAD-2.1 ASIC extends the maximum measurable x-ray signal (in 20 keV photon units) to > 10 7 x-rays/pixel/frame while maintaining a low read noise across the full dynamic range, all while imaging continuously at a frame rate of up to 10 kHz. The in-pixel dynamic charge removal mechanism prevents saturation of the input amplifier and proceeds in parallel with signal integration to achieve deadtime-less measurements with incident x-ray rates of > 10 10 x-rays/pixel/s. The ASIC format consists of 128 × 128 square pixels each 150 μm on a side and is designed to be 3-side buttable so large arrays can be effectively tiled. Here we use both laboratory x-ray sources and the Cornell High Energy Synchrotron Source (CHESS) to characterize two single ASIC prototype detectors for both low (single x-ray) and high incident flux detection. In the first detector the ASIC was solder bump-bonded to a 500 μm thick Si sensor for efficient detection of x-rays below 20 keV, whereas the second detector used a 750 μm thick CdTe sensor for x-rays above ~20 keV.

36 MATERIALS SCIENCE↗

Efficiency and coherence preservation studies of Be refractive lenses for XFELO application

Performance tests of parabolic beryllium refractive lenses, considered as X-ray focusing elements in the future X-ray free-electron laser oscillator (XFELO), are reported. Single and double refractive lenses were subject to X-ray tests, which included: surface profile, transmissivity measurements, imaging capabilities and wavefront distortion with grating interferometry. Optical metrology revealed that surface profiles were close to the design specification in terms of the figure and roughness. The transmissivity of the lenses is >94% at 8 keV and >98% at 14.4 and 18 keV. These values are close to the theoretical values of ideal lenses. Images of the bending-magnet source obtained with the lenses were close to the expected ones and did not show any significant distortion. Grating interferometry revealed that the possible wavefront distortions produced by surface and bulk lens imperfections were on the level of ~λ/60 for 8 keV photons. Thus the Be lenses can be succesfully used as focusing and beam collimating elements in the XFELO.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Repeatable, multiple-peaked structure in Type I X-ray bursts

A distinct, identifiable, multiple-peaked structure has been observed in Type I X-ray bursts from three sources. At energies below 6 keV, the light curves look like typical Type I bursts. At higher energies, the burst is double-peaked, with both the depth of the dip and the separation between the peaks increasing with energy. A light curve of the energy-integrated intensity shows no distinct double peak, suggesting that only a single energy release occurs. Blackbody fits to the evolving burst spectra yield changing radii and temperatures, inversely correlated, during the early part of the burst. The physical interpretation of these changes is uncertain. Burst decay spectra yield relatively constant radii with decreasing temperatures. It is proposed that Compton scattering may be responsible for the dips in the higher-energy light curves by shifting photons to lower energies.

Hoffman, J. A.↗

THE RADIO ACTIVITY-ROTATION RELATION OF ULTRACOOL DWARFS

We present a new radio survey of about 100 late-M and L dwarfs undertaken with the Very Large Array. The sample was chosen to explore the role of rotation in the radio activity of ultracool dwarfs. As part of the survey we discovered radio emission from three new objects, 2MASS J 0518113 - 310153 (M6.5), 2MASS J 0952219 - 192431 (M7), and 2MASS J 1314203 + 132001 (M7), and made an additional detection of LP 349-25 (M8). Combining the new sample with results from our previous studies and from the literature, we compile the largest sample to date of ultracool dwarfs with radio observations and measured rotation velocities (167 objects). In the spectral type range M0-M6 we find a radio activity-rotation relation, with saturation at L{sub rad}/L{sub bol} Almost-Equal-To 10{sup -7.5} above vsin i Almost-Equal-To 5 km s{sup -1}, similar to the relation in H{alpha} and X-rays. However, at spectral types {approx}> M7 the ratio of radio to bolometric luminosity increases significantly regardless of rotation velocity, and the scatter in radio luminosity increases. In particular, while the most rapid rotators (vsin i {approx}> 20 km s{sup -1}) exhibit 'super-saturation' in X-rays and H{alpha}, this effect is not seen in the radio. We also find that ultracool dwarfs with vsin i {approx}> 20 km s{sup -1} have a higher radio detection fraction by about a factor of three compared to objects with vsin i {approx}< 10 km s{sup -1}. When measured in terms of the Rossby number (Ro), the radio activity-rotation relation follows a single trend and with no apparent saturation from G to L dwarfs and down to Ro {approx} 10{sup -3}; in X-rays and H{alpha} there is clear saturation at Ro {approx}< 0.1, with super-saturation beyond M7. A similar trend is observed for the radio surface flux (L{sub rad}/R{sup 2}{sub *}) as a function of Ro. The continued role of rotation in the overall level of radio activity and in the fraction of active sources, and the single trend of L{sub rad}/L{sub bol} and L{sub rad}/R{sup 2}{sub *} as a function of Ro from G to L dwarfs, indicates that rotation effects are important in regulating the topology or strength of magnetic fields in at least some fully convective dwarfs. The fact that not all rapid rotators are detected in the radio provides additional support to the idea of dual dynamo states proposed from spectropolarimetric observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Microbeam radiation therapy: A Monte Carlo study of the influence of the source, multislit collimator, and beam divergence on microbeams

Microbeam radiation therapy (MRT) is a new oncology method currently under development for the treatment of inoperable pediatric brain tumors. Monte Carlo simulation, or the computational study of radiation transport in matter, is often used in radiotherapy to theoretically estimate the dose required for treatment. However, its potential use in MRT dose planning systems is currently hindered by the significant discrepancies that have been observed between measured and theoretical dose and the PVDR (peak to valley dose ratio). The need to resolve these discrepancies is driven by the desirability of making MRT available to humans in the next few years. This article aims to resolve some of the discrepancies by examining the simplifications adopted in previous MRT Monte Carlo studies, such as the common practice of commencing microbeam transport on the surface of the target which neglects the influence of the distributed synchrotron source, multislit collimator, and the beam divergence between them. This article uses PENELOPE Monte Carlo simulation to investigate the influence of these beamline components upstream of the target on the lateral dose profiles and PVDRs of an array of 25 microbeams. It also compares the dose profiles and PVDRs of a microbeam array produced from a single simulation (full array) to those produced from the superposition of a single microbeam profile (sup array). The effect of modeling the distributed source and the beam divergence was an increase in the absorbed dose in the penumbral and valley regions of the microbeam profiles. Inclusion of the multislit collimator resulted in differences of up to 5 {mu}m in the FWHM of microbeam profiles across the array, which led to minor variations in the corresponding PVDR yields.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Self-consistent Maxwell-Bloch theory of quantum-dot-population switching in photonic crystals

We theoretically demonstrate the population switching of quantum dots (QD's), modeled as two-level atoms in idealized one-dimensional (1D) and two-dimensional (2D) photonic crystals (PC's) by self-consistent solution of the Maxwell-Bloch equations. In our semiclassical theory, energy states of the electron are quantized, and electron dynamics is described by the atomic Bloch equation, while electromagnetic waves satisfy the classical Maxwell equations. Near a waveguide cutoff in a photonic band gap, the local electromagnetic density of states (LDOS) and spontaneous emission rates exhibit abrupt changes with frequency, enabling large QD population inversion driven by both continuous and pulsed optical fields. We recapture and generalize this ultrafast population switching using the Maxwell-Bloch equations. Radiative emission from the QD is obtained directly from the surrounding PC geometry using finite-difference time-domain simulation of the electromagnetic field. The atomic Bloch equations provide a source term for the electromagnetic field. The total electromagnetic field, consisting of the external input and radiated field, drives the polarization components of the atomic Bloch vector. We also include a microscopic model for phonon dephasing of the atomic polarization and nonradiative decay caused by damped phonons. Our self-consistent theory captures stimulated emission and coherent feedback effects of the atomic Mollow sidebands, neglected in earlier treatments. This leads to remarkable high-contrast QD-population switching with relatively modest (factor of 10) jump discontinuities in the electromagnetic LDOS. Switching is demonstrated in three separate models of QD's placed (i) in the vicinity of a band edge of a 1D PC, (ii) near a cutoff frequency in a bimodal waveguide channel of a 2D PC, and (iii) in the vicinity of a localized defect mode side coupled to a single-mode waveguide channel in a 2D PC.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In Situ Mineralogical Analysis of Planetary Materials Using X-Ray Diffraction and X-Ray Fluorescence

Remote observations of Mars have led scientists to believe that its early climate was similar to that of the early Earth, having had abundant liquid water and a dense atmosphere. One of the most fascinating questions of recent times is whether simple bacterial life developed on Mars (as it did on the Earth) during this early element period. Analyses of SNC meteorites have broadened considerably our knowledge of the chemistry of certain types of Martian rocks, underscoring the tantalizing possibility of early hydrothermal systems and even of ancient bacterial life. Detailed analyses of SNC meteorites in Terrestrial laboratories utilize the most sophisticated organic, isotopic and microscopic techniques in existence. Indeed; it is unlikely that the key biogenic indicators used in McKay et al (ibid) could be identified by a remote instrument on the surface of Mars. As a result, it is probable that any robotic search for evidence of an ancient Martian biosphere will have as its focus the identification of key minerals in likely host rocks rather than the direct detection of organic or isotopic biomarkers. Even on a sample return mission, mineralogical screening will be utilized to choose the most likely candidate rocks. X-ray diffraction (XRD) is the only technique that can provide a direct determination of the crystal structures of the phases present within a sample. When many different crystalline phases are present, quantitative analysis is better constrained if used in conjunction with a determination of elemental composition, obtainable by X-ray fluorescence (XRF) using the same X-ray source as for XRD. For planetary surface analysis, a remote instrument combining XRD and XRF could be used for mineralogical characterization of both soils and rocks. We are designing a remote XRD/XRF instrument with this objective in mind. The instrument concept pays specific attention to constraints in sample preparation, weight, volume, power, etc. Based on the geometry of a pinhole camera (transmission geometry, flat two-dimensional detector perpendicular to the direct beam), the instrument (which we call CHEMIN, for Chemistry and Mineralogy) uses an X-ray sensitive CCD detector which will allow concurrent positional and energy-dispersive analysis of collected photons. Thus XRF (energy) and XRD (geometry) analysis of transmitted X-rays will be performed at the same time. Tests performed with single minerals and simple mixtures give promising results. Refinements of the prototype promise interpretable results on complex samples.

Sarrazin, P.↗

The Case for Space-Borne Far-Infrared Line Surveys

The combination of sensitive direct detectors and a cooled aperture promises orders of magnitude improvement in the sensitivity and survey time for far-infrared and submillimeter spectroscopy compared to existing or planned capabilities. Continuing advances in direct detector technology enable spectroscopy that approaches the background limit available only from space at these wavelengths. Because the spectral confusion limit is significantly lower than the more familiar spatial confusion limit encountered in imaging applications, spectroscopy can be carried out to comparable depth with a significantly smaller aperture. We are developing a novel waveguide-coupled grating spectrometer that disperses radiation into a wide instantaneous bandwidth with moderate resolution (R ~ 1000) in a compact 2-dimensional format. A line survey instrument coupled to a modest cooled single aperture provides an attractive scientific application for spectroscopy with direct detectors. Using a suite of waveguide spectrometers, we can obtain complete coverage over the entire far-infrared and sub-millimeter. This concept requires no moving parts to modulate the optical signal. Such an instrument would be able to conduct a far-infrared line survey 10 6 times faster than planned capabilities, assuming existing detector technology. However, if historical improvements in bolometer sensitivity continue, so that photon-limited sensitivity is obtained, the integration time can be further reduced by 2 to 4 orders of magnitude, depending on wavelength. The line flux sensitivity would be comparable to ALMA, but at shorter wavelengths and with the continuous coverage needed to extract line fluxes for sources at unknown redshifts. For example, this capability would break the current spectroscopic bottleneck in the study of far-infrared galaxies, the recently discovered, rapidly evolving objects abundant at cosmological distances.

Bock, J. J.↗

Signatures of linearized gravity in atom interferometers: A simplified computational framework

We develop a general framework for calculating the leading-order, general relativistic contributions to the gravitational phase shift in single-photon atom interferometers within the context of linearized gravity. We show that the atom gradiometer observable, which only depends on the atom interferometer propagation phase, can be written in terms of three distinct contributions: the Doppler phase shift, which accounts for the tidal displacement of atoms along the baseline, the Shapiro phase shift, which accounts for the delay in the arrival time of photons at atom-light interaction points, and the Einstein phase shift, which accounts for the gravitational redshift measured by the atoms. For specific atom gradiometer configurations, we derive the signal and response functions for two physically motivated scenarios: (i) transient gravitational waves in the transverse-traceless gauge and, for the first time, in the proper detector frame, and (ii) transient massive objects sourcing weak and slow-varying Newtonian potentials. Here, we find that the Doppler contribution of realistic Newtonian noise sources (e.g., a freight truck or a piece of space debris) at proposed atom gradiometer experiments, such as AION, MAGIS, and AEDGE, can exceed the shot noise level and thus affect physics searches if not properly subtracted. Note: 44 pages including appendices, 4 figures; v2: different formatting, fixed typos, 28 pages including appendices, 5 figures, agrees with published version

Atom interferometry↗

VeryFastCCD: a high frame rate soft X-ray detector

Direct X-ray detection in silicon has been transformative for scattering experiments in biology and materials science. While bump-bonded hybrid pixels have been attractive for hard X-ray detection, the challenge for single photon soft X-ray detection is sufficiently low noise. CCD structures on thick, high-resistivity silicon have been successfully used as sensors over the range of soft to hard X-rays at storage rings and FELs. The VeryFastCCD is a high frame rate, column-parallel CCD sensor with 48 μm pixels. Combined with 256-channel custom readout ASICs, frame rates of 5–10 kHz have been achieved with readout noise as low as 20 e and full-well capacity >4 × 10 5 e/pixel. Thin (10 nm and 100 nm) entrance window contact processes have also been developed which provide >85% quantum efficiency for 285 eV X-rays. Systems are currently being developed for several beamlines at the upgraded Advanced Light Source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Eta Carinae: What We have learned recently with HST/STIS, VLT/UVES and VLTI: What We Might Learn with VLT/VLTI across the 2008/9 Minimum

Eta Carinae, the LBV that we have learned to love and hate, has revealed many clues of its character over the past seven years by studies with HST and VLT. Based upon X-Ray, optical and IR observations, Eta Carinae is convincingly a massive binary system that uniquely has major nebular ejecta that are connected with historical outbursts. We have successhlly followed the stellar and nebular changes over the 5.5 year cycle, especially with STIS and RXTE, and across the spectroscopic minimum in 2003.5 with STIS, CHANDRA, RXTE, FUSE, and VLT/UVES. The HST/STIS high spatial resolution, combined with appropriate spectral resolving powers from 1150 to 10300 A, has revealed much about the Central Source and especially the spatially resolved extended stellar atmosphere and the ejecta, known as the Homunculus. Indeed the neutral, dusty outer Homunculus, ejected in the 1840s, envelops the newly discovered ionized Little Homunculus, ejected in the 1890s. In line of sight, multiple hot clumps, both ionized and neutral, are seen in absorption and provide much information on the physical conditions of these massive ejecta. Against the nebular-scattered starlight, wind and nebular absorptions provide views at different angles from line of sight. The VLT/UVES studies from 2002 through 2004 provided very important time-sampled spectra of both the star as seen directly and as seen by the SE lobe viewing the polar region of the star. The VLTI 2.2 micron measures of the central source are consistent with a prolate spheroid with its axis extending along the axis of the Homunculus. This is consistent with the noticeably larger wind mass and higher terminal velocity along the axis of the Homunculus compared to that measured in line of sight at about 45 degrees from the polar axes. We understand the system to be a massive primary with an O or WR companion in a very highly elliptical orbit. The spectroscopic minimum occurs during periastron, when the greatly extended primary atmosphere and wind bottles up the ionizing uv radiation of the companion star. This transient drop in uv photons leads to recombination of much of the wind structure and of the nearby ejecta. Doubly-ionized elements (iron, neon, argon, vanadium) recombine to singly ionized forms and extended structures on the scales of below 0.03 arcseconds to an arcsecond change, appear, or disappear. With the loss of the STIS on HST, ground-based observations, especially with high spatial-resolution facilities, including the VLT and VLTI will be key to further studies across the minimum centered on 2009.0. Now is the time to plan for these studies.

Gull, Theodore R.↗

Identification of the Hard X-Ray Source Dominating the E > 25 keV Emission of the Nearby Galaxy M31

We report the identification of a bright hard X-ray source dominating the M31 bulge above 25 kiloelectronvolts from a simultaneous NuSTAR-Swift observation. We find that this source is the counterpart to Swift J0042.6+4112, which was previously detected in the Swift BAT All-Sky Hard X-Ray Survey. This Swift BAT source had been suggested to be the combined emission from a number of point sources; our new observations have identified a single X-ray source from 0.5 to 50 kiloelectronvolts as the counterpart for the first time. In the 0.5-10 kiloelectronvolt band, the source had been classified as an X-ray Binary candidate in various Chandra and XMM-Newton studies; however, since it was not clearly associated with Swift J0042.6+4112, the previous E is less than 10 kiloelectronvolts observations did not generate much attention. This source has a spectrum with a soft X-ray excess (kT approximately equal to 0.2 kiloelectronvolts) plus a hard spectrum with a power law of gamma approximately equal to 1 and a cutoff around 15-20 kiloelectronvolts, typical of the spectral characteristics of accreting pulsars. Unfortunately, any potential pulsation was undetected in the NuSTAR data, possibly due to insufficient photon statistics. The existing deep HST (Hubble Space Telescope) images exclude high-mass (greater than 3 times the radius of the moon) donors at the location of this source. The best interpretation for the nature of this source is an X-ray pulsar with an intermediate-mass (less than 3 times the radius of the moon M) companion or a symbiotic X-ray binary. We discuss other possibilities in more detail.

galaxies: bulges – galaxies: individual (M31)↗