Search NASA⌕ Search

SEARCH · Search NASA

Results for “stream operators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

The effect of cycle variables on the emissions and performance of lean premixed gas turbine primary zone combustor

Experiments were conducted in which a stream of premixed propane and air was burned under conditions representative of gas-turbine operation. Emissions of NOx, CO, and unburned hydrocarbons were measured over a range of combustor inlet temperature (600-1000 K), pressure (5-30 atm), and residence time (1-3 msec) at equivalence ratios from 0.7 down to the lean stability limit. At inlet temperatures of 800 and 1000 K, NOx emissions displayed little sensitivity to pressure. At an inlet temperature of 600 K, observed NOx levels dropped markedly with decreasing pressure for pressures below 20 atm. NOx levels were proportional to combustor residence time, and formation rate was principally a function of adiabatic flame temperature. For adiabatic flame temperatures of 2050 K and higher, CO reached chemical equilibrium within 2 msec. Unburned hydrocarbon species dropped to a negligible level within 2 msec regardless of inlet temperature, pressure, or equivalence ratio. For a combustor residence time of 2.5 msec, combustion inefficiency became less than 0.01% at an adiabatic flame temperature of 2050 K. The maximum combustion inefficiency observed was of the order of 1% and corresponded to conditions near the lean stability limit.

Roffe, G.↗

Measurements of flow phenomena induced by suction through perforated and partially plugged surfaces

Efforts were directed towards completing construction of the windtunnel test section, assembling instrumentation, programming the data acquisition and reduction system, adjusting the streamwise pressure gradient of the test section, calibrating the hot-wire anemometer probe, and constructing and testing a smoke generator. The test section was installed in the wind tunnel and is completely operational. The streamwise pressure gradient was adjusted to be nominally zero at a free-stream velocity of 3.05 m/s (10 ft/s). This was accomplished by adjusting the upper wall of the test section to be slightly divergent. The change in static pressure between any two streamwise locations in the test section was less than one percent of the free-stream dynamic pressure. A suitable means was found for accurately calibrating the hot-wire probe which is used to measure boundary-layer velocity profiles and fluctuating velocities.

Wilkinson, S. P.↗

Convolutional coding results for the MVM '73 X-band telemetry experiment

Results of simulation of several short-constraint-length convolutional codes using a noisy symbol stream obtained via the turnaround ranging channels of the MVM'73 spacecraft are presented. First operational use of this coding technique is on the Voyager mission. The relative performance of these codes in this environment is as previously predicted from computer-based simulations.

Layland, J. W.↗

Plasma torch igniter for scramjets

A small, uncooled plasma torch was developed and used in combination with an injector designed to study ignition and flameholding in hydrogen-fueled supersonic flows. The plasma torch was operated on mixtures of hydrogen and argon with total flows of 10 to 70 scfh. The fuel injector design consisted of five small upstream pilot fuel injectors, a rearward facing step for recirculation, and three main fuel injectors downstream of the step. The plasma torch was located in the recirculation region, and all injection was perpendicular to the Mach 2 stream. Both semi-freejet and ducted tests were conducted. The experimental results indicate that a low power plasma torch operating on a 1:1 volumetric mixture of hygrogen and argon and located in the recirculation zone fueled by the upstream pilot fuel injectors is a good igniter for flow conditions simulating a flight Mach number of 3.7. The total temperature required to autoignite the hydrogen fuel for this injector geometry was 2640 R. The injector configuration was shown to be a good flameholder over a wide range of total temperature. Spectroscopic measurements were used to verify the presence of air total temperatures below 1610 R.

Wagner, Timothy C.↗

Laser velocimetry in turbulent flow fields - Particle response

Measurements of the particle response in a decelerating flow and a highly turbulent two-phase flow were obtained. Simultaneous measurements of the particle size and velocity served to quantify the particle response to the prevailing flow field. In the case of a flow incident upon a cylinder, the particle lag for a range of size classes was recorded. Results were also obtained in the flow generated by an atomizer operating on the leeward side of a flat disk bluff body in a coflowing air stream. Measurements of the mean axial, mean radial, and rms velocities and angles of trajectories were obtained for representative particle size classes. The air velocity and turbulence intensity were inferred from the seed particles on the order of one micrometer in diameter. Particles 9 micrometers and larger showed significant differences with respect to the gas phase mean velocity and turbulence intensity even at low velocities. In two-phase flows, reliable measurements of the continuous phase velocity and turbulence parameters requires the simultaneous measurement of particle size as a means for rejecting readings from large particles from the velocity pdf's.

Bachalo, W. D.↗

Space plasma contactor research, 1987

A simple model describing the process of electron collection from a low pressure ambient plasma in the absence of magnetic field and contactor velocity effects is presented. Experimental measurments of the plasma surrounding the contactor are used to demonstrate that a double-sheath generally develops and separates the ambient plasma from a higher density, anode plasma located adjacent to the contactor. Agreement between the predictions of the model and experimental measurements obtained at the electron collection current levels ranging to 1 A suggests the surface area at the ambient plasma boundary of the double-sheath is equal to the electron current being collected divided by the ambient plasma random electron current density; the surface area of the higher density anode plasma boundary of the double-sheath is equal to the ion current being emitted across this boundary divided by the ion current density required to sustain a stable sheath; and the voltage drop across the sheath is determined by the requirement that the ion and electron currents counterflowing across the boundaries be at space-charge limited levels. The efficiency of contactor operation is shown to improve when significant ionization and excitation is induced by electrons that stream from the ambient plasma through the double-sheath and collide with neutral atoms being supplied through the hollow cathode.

Wilbur, Paul J.↗

Plasma torch igniter for scramjets

A small, uncooled plasma torch was developed and used in combination with an injector designed to study ignition and flameholding in hydrogen-fueled supersonic flows. The plasma torch was operated on mixtures of hydrogen and argon with total flows of 10 to 70 scfh. The fuel injector design consisted of five small upstream pilot fuel injectors, a rearward facing step for recirculation, and three main fuel injectors downstream of the step. The plasma torch was located in the recirculation region, and all injection was perpendicular to the Mach 2 stream. Both semi-freejet and ducted tests were conducted. The experimental results indicate that a low power plasma torch operating on a 1:1 volumetric mixture of hydrogen and argon and located in the recirculation zone fueled by the upstream pilot fuel injectors is a good igniter for flow conditions simulating a flight Mach number of 3.7. The total temperature required to autoignite the hydrogen fuel for this injector geometry was 2640 R. The injector configuration was shown to be a good flameholder over a wide range of total temperature. Spectroscopic measurements were used to verify the presence of air total temperatures below 1610 R.

Wagner, Timothy C.↗

Arc Jet Flow Properties Determined from Laser- Induced Fluorescence of Atomic Species

Flow property measurements that were recently acquired in the Ames Research Center Aerodynamic Heating Facility (AHF) arc jet using two-photon Laser-Induced Fluorescence (LIF) of atomic nitrogen and oxygen are reported. The measured properties, which include velocity, translational temperature, and species concentration, cover a wide range of facility operation for the 30 cm nozzle. During the tests, the arc jet pressure and input stream composition were maintained at fixed values and the arc current was varied to vary the flow enthalpy. As part of this ongoing effort, a measurement of the two-photon absorption coefficient for the 3p4D(left arrow)2p4S transition of atomic nitrogen was performed, and the measured value is used to convert the relative concentration measurements to absolute values. A flow reactor is used to provide a known temperature line shape profile to deconvolve the laser line width contribution to the translational temperature measurements. Results from the current experiments are compared with previous results obtained using NO-beta line profiles at room temperature and the problem of multimode laser oscillation and its impact on the two-photon excitation line shape are discussed. One figure is attached, and this figure show relative N atom concentration measurements as a function of the arc power. Other measurements have already been acquired and analyzed. The arc jet flow facilities are heavily used in thermal protection material development and evaluation. All hypersonic flight and planetary atmospheric entry vehicles will use materials tested in these arc jet facilities. This poster represents an application of laser-spectroscopic measurements in an important test facility.

Fletcher, Douglas G.↗

Arcjet Flow Properties Determined from Laser-Induced Fluorescence of Atomic Species

Flow property measurements that were recently acquired in the Ames Research Center Aerodynamic Heating Facility (AHF) arc jet using two-photon Laser-Induced Fluorescence (LIF) of atomic nitrogen and oxygen are reported. The measured properties, which include velocity, translational temperature, and species concentration, cover a wide range of facility operation for the 30 cm nozzle. During the tests, the arc jet pressure and input stream composition were maintained at fixed values and the arc current was varied to vary the flow enthalpy. As part of this ongoing effort, a measurement of the two-photon absorption coefficient for the 3p4D<-2p4S transition of atomic nitrogen was performed, and the measured value is used to convert the relative concentration measurements to absolute values. A flow reactor is used to provide a known temperature line shape profile to deconvolve the laser line width contribution to the translational temperature measurements. Results from the current experiments are compared with previous results obtained using NO-Beta line profiles at room temperature and the problem of multimode laser oscillation and its impact on the two-photon excitation line shape are discussed. One figure is attached, and this figure shows relative N atom concentration measurements as a function of the arc power. Other measurements have already been acquired and analyzed. This poster represents an application of laser-spectroscopic measurements in an important test facility. The arc jet flow facilities are heavily used in thermal protection material development and evaluation. All hypersonic flight and planetary atmospheric entry vehicles will use materials tested in these arc jet facilities.

Fletcher, Douglas G.↗

A Complexity Metric for Automated Separation

A metric is proposed to characterize airspace complexity with respect to an automated separation assurance function. The Maneuver Option metric is a function of the number of conflict-free trajectory change options the automated separation assurance function is able to identify for each aircraft in the airspace at a given time. By aggregating the metric for all aircraft in a region of airspace, a measure of the instantaneous complexity of the airspace is produced. A six-hour simulation of Fort Worth Center air traffic was conducted to assess the metric. Results showed aircraft were twice as likely to be constrained in the vertical dimension than the horizontal one. By application of this metric, situations found to be most complex were those where level overflights and descending arrivals passed through or merged into an arrival stream. The metric identified high complexity regions that correlate well with current air traffic control operations. The Maneuver Option metric did not correlate with traffic count alone, a result consistent with complexity metrics for human-controlled airspace.

Aweiss, Arwa↗

Portable Airborne Laser System Measures Forest-Canopy Height

(PALS) is a combination of laser ranging, video imaging, positioning, and data-processing subsystems designed for measuring the heights of forest canopies along linear transects from tens to thousands of kilometers long. Unlike prior laser ranging systems designed to serve the same purpose, the PALS is not restricted to use aboard a single aircraft of a specific type: the PALS fits into two large suitcases that can be carried to any convenient location, and the PALS can be installed in almost any local aircraft for hire, thereby making it possible to sample remote forests at relatively low cost. The initial cost and the cost of repairing the PALS are also lower because the PALS hardware consists mostly of commercial off-the-shelf (COTS) units that can easily be replaced in the field. The COTS units include a laser ranging transceiver, a charge-coupled-device camera that images the laser-illuminated targets, a differential Global Positioning System (dGPS) receiver capable of operation within the Wide Area Augmentation System, a video titler, a video cassette recorder (VCR), and a laptop computer equipped with two serial ports. The VCR and computer are powered by batteries; the other units are powered at 12 VDC from the 28-VDC aircraft power system via a low-pass filter and a voltage converter. The dGPS receiver feeds location and time data, at an update rate of 0.5 Hz, to the video titler and the computer. The laser ranging transceiver, operating at a sampling rate of 2 kHz, feeds its serial range and amplitude data stream to the computer. The analog video signal from the CCD camera is fed into the video titler wherein the signal is annotated with position and time information. The titler then forwards the annotated signal to the VCR for recording on 8-mm tapes. The dGPS and laser range and amplitude serial data streams are processed by software that displays the laser trace and the dGPS information as they are fed into the computer, subsamples the laser range and amplitude data, interleaves the subsampled data with the dGPS information, and records the resulting interleaved data stream.

Nelson, Ross↗

Field Evaluation of the Baseline Integrated Arrival, Departure, and Surface Capabilities at Charlotte Douglas International Airport

NASA is currently developing a suite of decision support capabilities for integrated arrival, departure, and surface (IADS) operations in a metroplex environment. The effort is being made in three phases, under NASA's Airspace Technology Demonstration 2 (ATD-2) sub-project, through a strong partnership with the Federal Aviation Administration (FAA), air carriers, airport, and general aviation community. The Phase 1 Baseline IADS capabilities provide enhanced operational efficiency and predictability of flight operations through data exchange and integration, tactical surface metering, and automated coordination of release time of controlled flights for overhead stream insertion. The users of the IADS system include the personnel at the Charlotte Douglas International Airport (CLT) air traffic control tower, American Airlines ramp tower, CLT terminal radar approach control (TRACON), and Washington Center. This paper describes the Phase 1 Baseline IADS capabilities and field evaluation conducted at CLT from September 2017 for a year. From the analysis of operations data, it is estimated that 538,915 kilograms of fuel savings, and 1,659 metric tons of CO2 emission reduction were achieved during the period with a total of 944 hours of engine run time reduction. The amount of CO2 savings is estimated as equivalent to planting 42,560 urban trees. The results have also shown that the surface metering had no negative impact on on-time arrival performance of both outbound and inbound flights. The technology transfer of Phase 1 Baseline IADS capabilities has been made to the FAA and aviation industry, and the development of additional capabilities for the subsequent phases is underway.

Jung, Yoon C.↗

Field Evaluation of the Baseline Integrated Arrival, Departure, and Surface (IADS) Capabilities at Charlotte Douglas International Airport (CLT)

NASA is currently developing a suite of decision support capabilities for integrated arrival, departure, and surface (IADS) operations in a metroplex environment. The effort is being made in three phases, under NASA's Airspace Technology Demonstration 2 (ATD-2) sub-project, through a strong partnership with the Federal Aviation Administration (FAA), air carriers, airport, and general aviation community. The Phase 1 Baseline IADS capabilities provide enhanced operational efficiency and predictability of flight operations through data exchange and integration, tactical surface metering, and automated coordination of release time of controlled flights for overhead stream insertion. The users of the IADS system include the personnel at the Charlotte Douglas International Airport (CLT) air traffic control tower, American Airlines ramp tower, CLT terminal radar approach control (TRACON), and Washington Center. This paper describes the Phase 1 Baseline IADS capabilities and field evaluation conducted at CLT from September 2017 for a year. From the analysis of operations data, it is estimated that 538,915 kilograms of fuel savings, and 1,659 metric tons of CO2 emission reduction were achieved during the period with a total of 944 hours of engine run time reduction. The amount of CO2 savings is estimated as equivalent to planting 42,560 urban trees. The results have also shown that the surface metering had no negative impact on on-time arrival performance of both outbound and inbound flights. The technology transfer of Phase 1 Baseline IADS capabilities has been made to the FAA and aviation industry, and the development of additional capabilities for the subsequent phases is underway.

and Surface (IADS)↗

A Two-Stage Regenerable Filter for Collection and Disposal of Carbon Fines

NASA is investigating the use of the Plasma Pyrolysis Assembly (PPA), which is a methane post-processing technology with the goal to recover hydrogen from the Carbon dioxide Reduction Assembly (CRA) currently onboard the International Space Station (ISS). The PPA can theoretically recover 75% of hydrogen from methane produced by the CRA. During methane processing the PPA creates roughly 40 mg/hr of carbon dust when operating at 4 crew member levels. The unwanted fines need to be removed from the stream to prevent any clogging of downstream components. The Regenerable Carbon Filter (RCF) was designed by Umpqua Research Company to address the carbon particulate created in the PPA. The RCF includes two stages. The first is an electrostatic precipitator designed to collect ultrafine particles. The second is a low pressure drop physical filter. Both filters are made of heat tolerant materials to allow regeneration of the filtration capacity by O2 oxidation of captured carbon. This paper will discuss the RCF hardware and test plans.

Filtration, Environmental Control, Life Support↗

Methods and devices for optimizing the operation of a semiconductor optical modulator

A semiconductor-based optical modulator includes a control loop to control and optimize the modulator's operation for relatively high data rates (above 1 GHz) and/or relatively high voltage levels. Both the amplitude of the modulator's driving voltage and the bias of the driving voltage may be adjusted using the control loop. Such adjustments help to optimize the operation of the modulator by reducing the number of errors present in a modulated data stream.

42 ENGINEERING↗

Field trial of the enhanced data authentication system (EDAS)

The Enhanced Data Authentication System (EDAS) is means to securely branch information from an existing measurement system or data stream to a secondary observer. In an international nuclear safeguards context, the EDAS connects to operator instrumentation, and provides a cryptographically secure copy of the information for a safeguards inspectorate. However, this novel capability could be a valuable complement to inspector-owned safeguards instrumentation, offering context that is valuable for anomaly resolution and contingency.

97 MATHEMATICS AND COMPUTING↗

High CO2 Capture Rate Cost and Performance for F- and H-Class Natural Gas Combined Cycles (NGCC)

The National Energy Technology Laboratory (NETL) is updating its study titled “Cost and Performance Baselines for Fossil Energy Plants, Volume 1: Bituminous Coal and Natural Gas to Electricity.” Revision 4 was published in 2019. Pulverized coal (PC) and natural gas combined cycle (NGCC) cases with carbon capture in that study capture carbon dioxide (CO2) at 90% efficiency. Field-testing of post-combustion CO2 capture technology as well as vendor and industry feedback on projects currently in the planning stages (including FEED projects sponsored by DOE) indicate that capture rates as high as 95% are feasible for both coal- and natural gas-fueled electricity generating units. Technology suppliers (as reflected in vendor-supplied information provided to DOE for this study that included cost and performance estimates for both NGCC (97%) and PC (99%) study cases) as well as subject matter experts acknowledge and support that solvent-based post-combustion CO2 capture technologies are capable of achieving CO2 removal rates beyond 95% on low-purity streams representative of fossil-fueled combustion; however, the relatively limited experience with design and operation of capture systems that can routinely, reliably, and economically achieve very high removal rates (e.g., 97% for NGCC flue gas) requires further study. This presentation will address performance and cost estimates for 90%, 95%, and 97% capture for F- and H-class NGCC plants. This presentation was given at the 2022 Pittsburgh Coal Conference.

Fout, Timothy↗