Search NASA⌕ Search

SEARCH · Search NASA

Results for “system software”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Exploratory Investigation of Disengagements and Crashes in Autonomous Vehicles Under Mixed Traffic: An Endogenous Switching Regime Framework

Autonomous Vehicles (AVs) have a large potential to improve traffic safety but also pose some critical challenges. While AVs may help reduce crashes caused by human error, they still may experience failures of technologies and sensing, as well as decision-making errors in a mixed traffic environment. A disengagement refers to an AV transitioning control from autonomous systems to the trained test driver. The safety critical nature of disengagements makes it imperative to analyze disengagements and crashes together. In this study, we analyze both crashes and disengagements from real-world AV driving in California to fill the knowledge gap regarding the relationship between disengagements and crashes in a mixed traffic environment. A nested logit model was calibrated using three different outcomes: (1) disengagement with a crash, (2) disengagement with no crash, and (3) no disengagement with a crash. Furthermore, endogenous switching regime models were also calibrated to draw distinctions between the relation of disengagements and crashes while accounting for endogeneity effects. The results show that factors related to AV systems (such as software failures) and other roadway participants increase the propensity of a disengagement without a crash. Furthermore, AVs were observed to disengage less often as the technology matured over time. Marginal effects revealed an 8% decrease. The results thus suggest that disengagements are a part of AVs' safe performance and disengagement alerts may need to be triggered in order to avoid certain failures with current technology.

42 ENGINEERING↗

Simplifying EPID dosimetry for IMRT treatment verification

Purpose: Electronic portal imaging devices (EPIDs) are increasingly used for IMRT dose verification, both pretreatment and in vivo. In this study, an earlier developed backprojection model has been modified to avoid the need for patient-specific transmission measurements and, consequently, leads to a faster procedure. Methods: Currently, the transmission, an essential ingredient of the backprojection model, is estimated from the ratio of EPID measurements with and without a phantom/patient in the beam. Thus, an additional irradiation to obtain ''open images'' under the same conditions as the actual phantom/patient irradiation is required. However, by calculating the transmission of the phantom/patient in the direction of the beam instead of using open images, this extra measurement can be avoided. This was achieved by using a model that includes the effect of beam hardening and off-axis dependence of the EPID response on photon beam spectral changes. The parameters in the model were empirically obtained by performing EPID measurements using polystyrene slab phantoms of different thickness in 6, 10, and 18 MV photon beams. A theoretical analysis to verify the sensitivity of the model with patient thickness changes was performed. The new model was finally applied for the analysis of EPID dose verification measurements of step-and-shoot IMRT treatments of head and neck, lung, breast, cervix, prostate, and rectum patients. All measurements were carried out using Elekta SL20i linear accelerators equipped with a hydrogenated amorphous silicon EPID, and the IMRT plans were made using PINNACLE software (Philips Medical Systems). Results: The results showed generally good agreement with the dose determined using the old model applying the measured transmission. The average differences between EPID-based in vivo dose at the isocenter determined using either the new model for transmission and its measured value were 2.6{+-}3.1%, 0.2{+-}3.1%, and 2.2{+-}3.9% for 47 patients treated with 6, 10, and 18 MV IMRT beams, respectively. For the same group of patients, the differences in mean {gamma} analysis (3% maximum dose, 3 mm) were 0.16{+-}0.26%, 0.21{+-}0.24%, and 0.02{+-}0.12%, respectively. For a subgroup of 11 patients, pretreatment verification was also performed, showing similar dose differences at the isocenter: -1.9{+-}0.9%, -1.4{+-}1.2%, and -0.4{+-}2.4%, with somewhat lower mean {gamma} difference values: 0.01{+-}0.09%, 0.01{+-}0.07%, and -0.09{+-}0.10%, respectively. Clinical implementation of the new model would save 450 h/yr spent in measurement of open images. Conclusions: It can be concluded that calculating instead of measuring the transmission leads to differences in the isocenter dose generally smaller than 2% (2.6% for 6 MV photon beams for in vivo dose) and yielded only slightly higher {gamma}-evaluation parameter values in planes through the isocenter. Hence, the new model is suitable for clinical implementation and measurement of open images can be omitted.

61 RADIATION PROTECTION AND DOSIMETRY↗

Poster — Thur Eve — 39: Feasibility of Commissioning HybridArc with the Delta 4 two plane diode phantom: comparisons with Gafchromic Film

HybridArc is a relatively novel radiation therapy technique which combines optimized dynamic conformai arcs (DCA) and intensity modulated radiation therapy (IMRT). HybridArc has possible dosimetry and efficiency advantages over stand alone DCA and IMRT treatments and can be readily implemented on any linac capable of DCA and IMRT, giving strong motivation to commission the modality. The Delta4 phantom (Scandidos, Uppsala, Sweden) has been used for IMRT and VMAT clinical dosimetric verification making it a candidate for HybridArc commissioning. However the HybridArc modality makes use of several non co-planar arcs which creates setup issues due to the geometry of the Delta4, resulting in possible phantom gantry collisions for plans with non-zero couch angles. An analysis was done determining the feasibility of using the Delta4 fixed at 0° couch angle compared with results obtained using Gafchromic ETB2 film (Ashland, Covington Kentucky) in an anthropomorphic phantom at the planned couch angles. A gamma index analysis of the measured and planned dose distributions was done using Delta4 and DoseLab Pro (Mobius Medical Systems, Houston Texas) software. For both arc and IMRT sub-fields there is reasonable correlation between the gamma index found from the Delta4 and Gafchromic film. All results show the feasibility of using the Delta4 for HybridArc commissioning.

60 APPLIED LIFE SCIENCES↗

SU-E-P-59: A Graphical Interface for XCAT Phantom Configuration, Generation and Processing

Purpose: To design a comprehensive open-source, publicly available, graphical user interface (GUI) to facilitate the configuration, generation, processing and use of the 4D Extended Cardiac-Torso (XCAT) phantom. Methods: The XCAT phantom includes over 9000 anatomical objects as well as respiratory, cardiac and tumor motion. It is widely used for research studies in medical imaging and radiotherapy. The phantom generation process involves the configuration of a text script to parameterize the geometry, motion, and composition of the whole body and objects within it, and to generate simulated PET or CT images. To avoid the need for manual editing or script writing, our MATLAB-based GUI uses slider controls, drop-down lists, buttons and graphical text input to parameterize and process the phantom. Results: Our GUI can be used to: a) generate parameter files; b) generate the voxelized phantom; c) combine the phantom with a lesion; d) display the phantom; e) produce average and maximum intensity images from the phantom output files; f) incorporate irregular patient breathing patterns; and f) generate DICOM files containing phantom images. The GUI provides local help information using tool-tip strings on the currently selected phantom, minimizing the need for external documentation. The DICOM generation feature is intended to simplify the process of importing the phantom images into radiotherapy treatment planning systems or other clinical software. Conclusion: The GUI simplifies and automates the use of the XCAT phantom for imaging-based research projects in medical imaging or radiotherapy. This has the potential to accelerate research conducted with the XCAT phantom, or to ease the learning curve for new users. This tool does not include the XCAT phantom software itself. We would like to acknowledge funding from MRA, Varian Medical Systems Inc.

60 APPLIED LIFE SCIENCES↗

Metabolic Synergy between Human Symbionts Bacteroides and Methanobrevibacter

Trophic interactions between microbes are postulated to determine whether a host microbiome is healthy or causes predisposition to disease. Two abundant taxa, the Gram-negative heterotrophic bacterium Bacteroides thetaiotaomicron and the methanogenic archaeon Methanobrevibacter smithii, are proposed to have a synergistic metabolic relationship. Both organisms play vital roles in human gut health; B. thetaiotaomicron assists the host by fermenting dietary polysaccharides, whereas M. smithii consumes end-stage fermentation products and is hypothesized to relieve feedback inhibition of upstream microbes such as B. thetaiotaomicron. To study their metabolic interactions, we defined and optimized a coculture system and used software testing techniques to analyze growth under a range of conditions representing the nutrient environment of the host. Here we verify that B. thetaiotaomicron fermentation products are sufficient for M. smithii growth and that accumulation of fermentation products alters secretion of metabolites by B. thetaiotaomicron to benefit M. smithii. Studies suggest that B. thetaiotaomicron metabolic efficiency is greater in the absence of fermentation products or in the presence of M. smithii. Under certain conditions, B. thetaiotaomicron and M. smithii form interspecies granules consistent with behavior observed for syntrophic partnerships between microbes in soil or sediment enrichments and anaerobic digesters. Furthermore, when vitamin B 12 , hematin, and hydrogen gas are abundant, coculture growth is greater than the sum of growth observed for monocultures, suggesting that both organisms benefit from a synergistic mutual metabolic relationship.

59 BASIC BIOLOGICAL SCIENCES↗

Pecos v. 1.0

Pecos is a python package designed to perform quality control analysis on time series data for system operations. The software loads time indexed databases, performs a series of quality control tests defined by the user, and creates automated reports which include summary statistics, tables, and graphics.

Klise, Katherine↗

Blockchain Based Remote Data Integrity Checking Tool v1.0

Computer System Security: The software is used to perform remote data integrity checking without relying on a single third party. In order to remove the trusted third party our tool uses distributed ledger (Blockchain) technology. The ledger is used to store evidences (in the form of hash values). These values are used as an input in the integrity checking process.

Wonjiga, Amir↗

Hybrid Optimization and Performance Platform (HOPP)

As part of NREL's Hybrid Energy Systems Research, this software assesses optimal designs for the deployment of utility-scale hybrid energy plants, particularly considering wind, solar and storage.

Tripp, CharlesEdison [National Renewable Energy La↗

Sparx PCA Module

Sparx, a new environment for Cryo-EM image processing; Cryo-EM, Single particle reconstruction, principal component analysis; Hardware Req.: PC, MAC, Supercomputer, Mainframe, Multiplatform, Workstation. Software Req.: operating system is Unix; Compiler C++; type of files: source code, object library, executable modules, compilation instructions; sample problem input data. Location/transmission: http://sparx-em.org; User manual & paper: http://sparx-em.org;

Yang, Chao↗

simcov v0.1

Simcov is an agent-based model of the spread of viral infections and the immune response in human lung at the cellular level. It is designed to scale well on HPC systems. No other software like it currently exists.

Hofmeyr, Steven↗

InvenioRDM Memento Proxy

The Memento Proxy software transforms Invenio systems on the web into repositories that are compliant with the Memento protocol.

Klein, Martin↗

Dependency Analysis Project

The Dependency Analysis Project creates datasets from package management ecosystems to determine what package a file was likely installed by, and provides tools to recognize implicit dependencies when source code is available for a variety of language ecosystems. The overarching goal is to help answer the question: what software does a system use?

Mast, Ryan↗

Automation Scripts for Feeder Analysis using CymPy

SAND2025-00330O Automation Scripts for Feeder Analysis using CymPy is a software tool that uses Python scripts to automate the analysis of power system feeders using CYME software. Utilities and researchers can use it to perform various types of analyses by leveraging the capabilities of CYME. The scripts use the CymPy library to interface with CYME and automate the analysis process. The software uses standard Python libraries along with the Eaton CymPy library. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525

Reno, Matthew↗

NEWTS USGS Brackish Water Database

Data from the USGS Brackish Water Database on brackish water compositions from across the US. Data has been filtered for high salinity and completeness of data attributes. Data has been transposed and converted for ease of input into aqueous chemistry modeling software including OLI Systems and Geochemist's Workbench. Original data from: Qi, S.L., and Harris, A.C., 2017, Geochemical Database for the Brackish Groundwater Assessment of the United States: U.S. Geological Survey data release, https://doi.org/10.5066/F72F7KK1.

Brackish Groundwater↗

NEWTS USGS Produced Waters Database

Data from the USGS Produced Waters Database on produced water compositions from across the US. Data has been filtered for completeness of data attributes. Data has been transposed and converted for ease of input into aqueous chemistry modeling software including OLI Systems and Geochemist's Workbench. Original data from: Blondes, M. S., Gans, K. D., Engle, M. A., Kharaka, Y. K., Reidy, M. E., Saraswathula, V., Thordsen, J. J., Rowan, E. L., & Morrissey, E. A. (2019). U.S. Geological Survey National Produced Waters Geochemical Database v2.3 [Data set]. U.S. Geological Survey. https://doi.org/10.5066/F7J964W8

Geochemists Workbench↗

WIRE SCANNER FOR HIGH INTENSITY BEAM PROFILE DIAGNOSITICS

A control and data acquisition system of a high speed wire scanner is developed for high intensity beam profile diagnostics. The control system of the wire scanner includes two IOCs, a Soft IOC and a VME IOC. The Soft IOC connects with an Aerotech Ensemble motor drive through EPCIS motor record and controls the movement of the wire scanner. An Electrical Input card samples the real-time position of the wire through an incremental encoder, and generates a pulse to synchronize a VME ADC data acquisition card, which digitizes and samples the beam-induced signal after pre-amplification. A VME Relay Output card is installed to control the Brake Solenoid and Actuator Solenoid. All the VME I/O cards are installed on one VME crate and controlled by the VME IOC. The system configuration and software of the wire scanner are under development.

Yan, J.↗