Search NASA⌕ Search

SEARCH · Search NASA

Results for “variable coefficients”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Distillation of mixed-state continuous-variable entanglement by photon subtraction

We present a detailed theoretical analysis for the distillation of one copy of a mixed two-mode continuous-variable entangled state using beam splitters and coherent photon-detection techniques, including conventional on-off detectors and photon-number-resolving detectors. The initial Gaussian mixed-entangled states are generated by transmitting a two-mode squeezed state through a lossy bosonic channel, corresponding to the primary source of errors in current approaches to optical quantum communication. We provide explicit formulas to calculate the entanglement in terms of logarithmic negativity before and after distillation, including losses in the channel and the photon detection, and show that one-copy distillation is still possible even for losses near the typical fiber channel attenuation length. A lower bound for the transmission coefficient of the photon-subtraction beam splitter is derived, representing the minimal value that still allows to enhance the entanglement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

WE-G-207-05: Relationship Between CT Image Quality, Segmentation Performance, and Quantitative Image Feature Analysis

Purpose: Segmentation quality can affect quantitative image feature analysis. The objective of this study is to examine the relationship between computed tomography (CT) image quality, segmentation performance, and quantitative image feature analysis. Methods: A total of 90 pathology proven breast lesions in 87 dedicated breast CT images were considered. An iterative image reconstruction (IIR) algorithm was used to obtain CT images with different quality. With different combinations of 4 variables in the algorithm, this study obtained a total of 28 different qualities of CT images. Two imaging tasks/objectives were considered: 1) segmentation and 2) classification of the lesion as benign or malignant. Twenty-three image features were extracted after segmentation using a semi-automated algorithm and 5 of them were selected via a feature selection technique. Logistic regression was trained and tested using leave-one-out-cross-validation and its area under the ROC curve (AUC) was recorded. The standard deviation of a homogeneous portion and the gradient of a parenchymal portion of an example breast were used as an estimate of image noise and sharpness. The DICE coefficient was computed using a radiologist’s drawing on the lesion. Mean DICE and AUC were used as performance metrics for each of the 28 reconstructions. The relationship between segmentation and classification performance under different reconstructions were compared. Distributions (median, 95% confidence interval) of DICE and AUC for each reconstruction were also compared. Results: Moderate correlation (Pearson’s rho = 0.43, p-value = 0.02) between DICE and AUC values was found. However, the variation between DICE and AUC values for each reconstruction increased as the image sharpness increased. There was a combination of IIR parameters that resulted in the best segmentation with the worst classification performance. Conclusion: There are certain images that yield better segmentation or classification performance. The best segmentation Result does not necessarily lead to the best classification Result. This work has been supported in part by grants from the NIH R21-EB015053. R Nishikawa is receives royalties form Hologic, Inc.

60 APPLIED LIFE SCIENCES↗

Thermal Expansion of EuF{sub 2+x} Single Crystals and Their Thermal Stability

Thermal expansion of an EuF{sub 2.136} nonstoichiometric crystal with the fluorite structure type (Eu{sub 0.864}{sup 2+}Eu{sub 0.136}{sup 3+}F{sub 2.136}, lattice parameter 5.82171(5) Å) has been experimentally investigated in the temperature range of 9–500 K. The coefficient of thermal expansion is α = 15.8 × 10{sup –6} K{sup –1} at T = 300 K. The observed anomalies in the behavior of the coefficient of thermal expansion at T > 400 K are related to the oxidation processes with partition of Eu{sup 2+} ions. It is established by differential scanning calorimetry that the onset temperature of EuF{sub 2+x} oxidation in air is 430 K and that this process occurs in three stages. X-ray diffraction analysis shows that the oxidation is accompanied by the formation of a phase mixture based on two modifications of the Eu{sub 1–y}{sup 3+}Eu{sub y}{sup 2+}F{sub 3–y} solid solution with the structure types of tysonite (LaF{sub 3}), orthorhombic β-YF{sub 3} phase, and europium oxyfluorides of variable composition EuO{sub 1–x}F{sub 1+2x}, with dominance of the latter.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

On the electric activity of superfluid helium at the excitation of first and second sound waves

We show that the electric activity of superfluid helium (HeII) observed in the experiments [3] during the excitation of standing second sound waves in an acoustic resonator can be described in terms of the phenomenological mechanism of the inertial polarization of atoms in a dielectric, in particular, in HeII, when the polarization field induced in the medium is proportional to the mechanical acceleration, by analogy with the Stewart-Tolman effect. The variable relative velocity w = v{sub n} - v{sub s} of the normal and superfluid HeII components that emerges in the second sound wave determines the mean group velocity of rotons, V{sub g} Almost-Equal-To w, with the density of the normal component related to their equilibrium number density in the temperature range 1.3 K {<=} T {<=} 2 K. Therefore, the acceleration of the 4He atoms involved in the formation of a roton excitation is proportional to the time derivative of the relative velocity.w. In this case, the linear local relations between the variable values of the electric induction, electric field strength, and polarization vector should be taken into account. As a result, the variable displacement current induced in the bulk of HeII and the corresponding potential difference do not depend on the anomalously low polarizability of liquid helium. This allows the ratio of the amplitudes of the temperature and potential oscillations in the second sound wave, which is almost independent of T in the above temperature range, consistent with experimental data to be obtained. At the same time, the absence of an electric response during the excitation of first sound waves in the linear regime is related to an insufficient power of the sound oscillations. Based on the experimental data on the excitation of first and second sounds, we have obtained estimates for the phenomenological coefficient of proportionality between the polarization vector and acceleration and for the drag coefficient of helium atoms by rotons in the second sound wave. We also show that the presence of a steady heat flow in HeII with nonzero longitudinal velocity and temperature gradients due to finite viscosity and thermal conductivity of the normal component leads to a change in the phase velocities of the first and second sound waves and to an exponential growth of their amplitudes with time, which should cause the amplitudes of the electric signals at the first and second sound frequencies to grow. This instability is analogous to the growth of the amplitude of long gravity waves on a shallow-water surface that propagate in the direction of decreasing basin depth.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

To have value, comparisons of high-throughput phenotyping methods need statistical tests of bias and variance

The gap between genomics and phenomics is narrowing. The rate at which it is narrowing, however, is being slowed by improper statistical comparison of methods. Quantification using Pearson’s correlation coefficient ( r ) is commonly used to assess method quality, but it is an often misleading statistic for this purpose as it is unable to provide information about the relative quality of two methods. Using r can both erroneously discount methods that are inherently more precise and validate methods that are less accurate. These errors occur because of logical flaws inherent in the use of r when comparing methods, not as a problem of limited sample size or the unavoidable possibility of a type I error. A popular alternative to using r is to measure the limits of agreement (LOA). However both r and LOA fail to identify which instrument is more or less variable than the other and can lead to incorrect conclusions about method quality. An alternative approach, comparing variances of methods, requires repeated measurements of the same subject, but avoids incorrect conclusions. Variance comparison is arguably the most important component of method validation and, thus, when repeated measurements are possible, variance comparison provides considerable value to these studies. Statistical tests to compare variances presented here are well established, easy to interpret and ubiquitously available. The widespread use of r has potentially led to numerous incorrect conclusions about method quality, hampering development, and the approach described here would be useful to advance high throughput phenotyping methods but can also extend into any branch of science. The adoption of the statistical techniques outlined in this paper will help speed the adoption of new high throughput phenotyping techniques by indicating when one should reject a new method, outright replace an old method or conditionally use a new method.

59 BASIC BIOLOGICAL SCIENCES↗

Thermally Effective and Efficient Cooling Technologies for Advanced Gas Turbine Systems

This report presents the research which has been undertaken under DOE grant DE-FE-0011875 as part of NETL’s UTSR (University Turbine System Research) Program. The experimental portion of this work was undertaken at the University of North Dakota (UND) under the direction of Dr. Forrest Ames. The computational work was undertaken at LSU (Louisiana State University), UM (University of Memphis), and at IIT (Illinois Institute of Technology) under the direction of Dr. Sumanta Acharya. The research program was organized into a four phase program which included: 1) development of a FDA/FEA (finite difference analysis/finite element analysis) cooling model, 2) experimental/computational investigation of appropriate internal cooling methods, 3) experimental/computational investigation of external heat transfer and film cooling, 4) development of an enhanced FDA/FEA model along with the development of a warm cascade test for comparison purposes. The experimental work at UND included research on both internal cooling methods and external heat transfer. The internal cooling work included the design and testing of multiple variable hole-size “incremental impingement” configurations along with testing of two converging rounded diamond pedestal arrays for the trailing edge region. The external heat transfer work included the building of a large scale cascade facility to test a vane design with a large leading edge and an aft loaded suction surface. UND has acquired both midspan and full suction surface heat transfer measurements as well as prepared for film cooling measurements under the grant. LSU/UM/IIT has developed and conducted wall resolved LES computations for the incremental impingement geometries and provided rational understanding of the effect of hole sizes and their distributions. Additionally they have provided design correlations for the incremental impingement heat transfer coefficients. They have also developed LES methods to predict flow through film cooling plenums, which have pedestals along with the development of slot film cooling downstream from the plenums. Additionally, they have developed wall resolved LES to predict vane surface heat transfer including bypass transition without the use of a transition model. Through these simulations they provide understanding of the aerodynamic and surface heat transfer behavior under a range of influences such as freestream turbulence. The present study has produced some very useful research outcomes.

01 COAL, LIGNITE, AND PEAT↗

Adaptive sparse polynomial chaos expansion based on least angle regression

Polynomial chaos (PC) expansions are used in stochastic finite element analysis to represent the random model response by a set of coefficients in a suitable (so-called polynomial chaos) basis. The number of terms to be computed grows dramatically with the size of the input random vector, which makes the computational cost of classical solution schemes (may it be intrusive (i.e. of Galerkin type) or non intrusive) unaffordable when the deterministic finite element model is expensive to evaluate. To address such problems, the paper describes a non intrusive method that builds a sparse PC expansion. First, an original strategy for truncating the PC expansions, based on hyperbolic index sets, is proposed. Then an adaptive algorithm based on least angle regression (LAR) is devised for automatically detecting the significant coefficients of the PC expansion. Beside the sparsity of the basis, the experimental design used at each step of the algorithm is systematically complemented in order to avoid the overfitting phenomenon. The accuracy of the PC metamodel is checked using an estimate inspired by statistical learning theory, namely the corrected leave-one-out error. As a consequence, a rather small number of PC terms are eventually retained (sparse representation), which may be obtained at a reduced computational cost compared to the classical 'full' PC approximation. The convergence of the algorithm is shown on an analytical function. Then the method is illustrated on three stochastic finite element problems. The first model features 10 input random variables, whereas the two others involve an input random field, which is discretized into 38 and 30 - 500 random variables, respectively.

97 MATHEMATICS AND COMPUTING↗

Galvanostatic Intermittent Titration Technique Reinvented: Part I. A Critical Review

The galvanostatic intermittent titration technique (GITT), introduced in 1977 by Weppner and Huggins, provided a readily accessible means to measuring the chemical diffusion coefficient of electrochemical electrode materials. The method continues to be widely used today, but the reported diffusivity values are highly inconsistent, ranging as much as four orders of magnitude for some Li layered oxide compositions. Even qualitative trends of diffusivity are inconsistent, suggesting significant flaws in the implementation of the method. Other variants of the GITT method also suffer from similar inconsistency problems. Here we identify numerous sources of significant error including composition-dependent reaction overpotentials, mathematical flaws in the relaxation analysis methods, finite-size and non-planar geometry effects, inter-particle inhomogeneity issues, early transient effects, and surface area uncertainties. We propose a simple relaxation analysis scheme using the time variable t relax + τ - t relax , where t relax is relaxation time and τ is the galvanostatic pulse duration. We also propose to use dense diffusion-limited samples to isolate the bulk-diffusion process in the time domain. Chemical diffusivity can be extracted much more reliably with this improved implementation of the GITT method.

25 ENERGY STORAGE↗

S-Preconditioner for Multi-fold Data Reduction with Guaranteed User-Controlled Accuracy

The growing gap between the massive amounts of data generated by petascale scientific simulation codes and the capability of system hardware and software to effectively analyze this data necessitates data reduction. Yet, the increasing data complexity challenges most, if not all, of the existing data compression methods. In fact, lossless compression techniques offer no more than 10% reduction on scientific data that we have experience with, which is widely regarded as effectively incompressible. To bridge this gap, in this paper, we advocate a transformative strategy that enables fast, accurate, and multi-fold reduction of double-precision floating-point scientific data. The intuition behind our method is inspired by an effective use of preconditioners for linear algebra solvers optimized for a particular class of computational dwarfs (e.g., dense or sparse matrices). Focusing on a commonly used multi-resolution wavelet compression technique as the underlying solver for data reduction we propose the S-preconditioner, which transforms scientific data into a form with high global regularity to ensure a significant decrease in the number of wavelet coefficients stored for a segment of data. Combined with the subsequent EQ-calibrator, our resultant method (called S-Preconditioned EQ-Calibrated Wavelets (SPEQC-WAVELETS)), robustly achieved a 4- to 5- fold data reduction while guaranteeing user-defined accuracy of reconstructed data to be within 1% point-by-point relative error, lower than 0:01 Normalized RMSE, and higher than 0:99 Pearson Correlation. In this paper, we show the results we obtained by testing our method on six petascale simulation codes including fusion, combustion, climate, astrophysics, and subsurface groundwater in addition to 13 publicly available scientific datasets. We also demonstrate that application-driven data mining tasks performed on decompressed variables or their derived quantities produce results of comparable quality with the ones for the original data.

Jin, Ye↗

Impact of CT attenuation correction method on quantitative respiratory-correlated (4D) PET/CT imaging

Purpose: Respiratory-correlated positron emission tomography (PET/CT) 4D PET/CT is used to mitigate errors from respiratory motion; however, the optimal CT attenuation correction (CTAC) method for 4D PET/CT is unknown. The authors performed a phantom study to evaluate the quantitative performance of CTAC methods for 4D PET/CT in the ground truth setting. Methods: A programmable respiratory motion phantom with a custom movable insert designed to emulate a lung lesion and lung tissue was used for this study. The insert was driven by one of five waveforms: two sinusoidal waveforms or three patient-specific respiratory waveforms. 3DPET and 4DPET images of the phantom under motion were acquired and reconstructed with six CTAC methods: helical breath-hold (3DHEL), helical free-breathing (3DMOT), 4D phase-averaged (4DAVG), 4D maximum intensity projection (4DMIP), 4D phase-matched (4DMATCH), and 4D end-exhale (4DEXH) CTAC. Recovery of SUV{sub max}, SUV{sub mean}, SUV{sub peak}, and segmented tumor volume was evaluated as RC{sub max}, RC{sub mean}, RC{sub peak}, and RC{sub vol}, representing percent difference relative to the static ground truth case. Paired Wilcoxon tests and Kruskal–Wallis ANOVA were used to test for significant differences. Results: For 4DPET imaging, the maximum intensity projection CTAC produced significantly more accurate recovery coefficients than all other CTAC methods (p < 0.0001 over all metrics). Over all motion waveforms, ratios of 4DMIP CTAC recovery were 0.2 ± 5.4, −1.8 ± 6.5, −3.2 ± 5.0, and 3.0 ± 5.9 for RC{sub max}, RC{sub peak}, RC{sub mean}, and RC{sub vol}. In comparison, recovery coefficients for phase-matched CTAC were −8.4 ± 5.3, −10.5 ± 6.2, −7.6 ± 5.0, and −13.0 ± 7.7 for RC{sub max}, RC{sub peak}, RC{sub mean}, and RC{sub vol}. When testing differences between phases over all CTAC methods and waveforms, end-exhale phases were significantly more accurate (p = 0.005). However, these differences were driven by the patient-specific respiratory waveforms; when testing patient and sinusoidal waveforms separately, patient waveforms were significantly different between phases (p < 0.0001) while the sinusoidal waveforms were not significantly different (p = 0.98). When considering only the subset of 4DMATCH images that corresponded to the end-exhale image phase, 4DEXH, mean and interquartile range were similar to 4DMATCH but variability was considerably reduced. Conclusions: Comparative advantages in accuracy and precision of SUV metrics and segmented volumes were demonstrated with the use of the maximum intensity projection and end-exhale CT attenuation correction. While respiratory phase-matched CTAC should in theory provide optimal corrections, image artifacts and differences in implementation of 4DCT and 4DPET sorting can degrade the benefit of this approach. These results may be useful to guide the implementation, analysis, and development of respiratory-correlated thoracic PET/CT in the radiation oncology and diagnostic settings.

60 APPLIED LIFE SCIENCES↗

Comparison of Combined X-Ray Radiography and Magnetic Resonance (XMR) Imaging-Versus Computed Tomography-Based Dosimetry for the Evaluation of Permanent Prostate Brachytherapy Implants

Purpose: To present a method for the dosimetric analysis of permanent prostate brachytherapy implants using a combination of stereoscopic X-ray radiography and magnetic resonance (MR) imaging (XMR) in an XMR facility, and to compare the clinical results between XMR- and computed tomography (CT)-based dosimetry. Methods and Materials: Patients who had received nonstranded iodine-125 permanent prostate brachytherapy implants underwent XMR and CT imaging 4 weeks later. Four observers outlined the prostate gland on both sets of images. Dose-volume histograms (DVHs) were derived, and agreement was compared among the observers and between the modalities. Results: A total of 30 patients were evaluated. Inherent XMR registration based on prior calibration and optical tracking required a further automatic seed registration step that revealed a median root mean square registration error of 4.2 mm (range, 1.6-11.4). The observers agreed significantly more closely on prostate base and apex positions as well as outlining contours on the MR images than on those from CT. Coefficients of variation were significantly higher for observed prostate volumes, D90, and V100 parameters on CT-based dosimetry as opposed to XMR. The XMR-based dosimetry showed little agreement with that from CT for all observers, with D90 95% limits of agreement ranges of 65, 118, 79, and 73 Gy for Observers 1, 2, 3, and 4, respectively. Conclusions: The study results showed that XMR-based dosimetry offers an alternative to other imaging modalities and registration methods with the advantages of MR-based prostate delineation and confident three-dimensional reconstruction of the implant. The XMR-derived dose-volume histograms differ from the CT-derived values and demonstrate less interobserver variability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Emergence of Intermediate Range Order in Jammed Packings

We perform a structural analysis of large scale jammed packings of monodisperse, frictionless and frictional spheres to elucidate structural signatures of the static structure factor in the low-to-intermediate wave number region. We employ discrete element method simulations containing up to 8×10^{7} particles, in which the particle friction coefficient(s), including sliding, rolling, and twisting interactions, are varied. At intermediate wave number values, corresponding to length scales that lie between that of the nearest neighbor primary peak and the system size, we find the emergence of a prepeak-a signature of intermediate range order-that grows with increasing friction. We correlate the emergence of this peak to real space fluctuations in the local particle coordination number, which exhibits a grainy fluctuating field throughout the packing process that is retained in the final, mechanically stable state. While the formation of the prepeak shows varying degrees of robustness to packing protocol changes, our results suggest that preparation history may be used to construct packings with variable large length scale structural properties.

Monti, Joseph M↗

Estimating Leaf Area Index in Row Crops Using Wheel-Based and Airborne Discrete Return Light Detection and Ranging Data

Leaf area index (LAI) is an important variable for characterizing plant canopy in crop models. It is traditionally defined as the total one-sided leaf area per unit ground area and is estimated by both direct and indirect methods. This paper explores the effectiveness of using light detection and ranging (LiDAR) data to estimate LAI for sorghum and maize with different treatments at multiple times during the growing season from both a wheeled vehicle and Unmanned Aerial Vehicles. Linear and nonlinear regression models are investigated for prediction utilizing statistical and plant structure-based features extracted from the LiDAR point cloud data with ground reference obtained from an in-field plant canopy analyzer (indirect method). Results based on the value of the coefficient of determination ( R 2 ) and root mean squared error for predictive models ranged from ∼0.4 in the early season to ∼0.6 for sorghum and ∼0.5 to 0.80 for maize from 40 Days after Sowing to harvest.

59 BASIC BIOLOGICAL SCIENCES↗

Numerical Prediction of Cyclic Variability in a Spark Ignition Engine Using a Parallel Large Eddy Simulation Approach

Cycle-to-cycle variability (CCV) is detrimental to IC engine operation and can lead to partial burn, misfire, and knock. Predicting CCV numerically is extremely challenging due to two key reasons. First, high-fidelity methods such as large eddy simulation (LES) are required to accurately resolve the in-cylinder turbulent flow field both spatially and temporally. Second, CCV is experienced over long timescales and hence the simulations need to be performed for hundreds of consecutive cycles. Ameen et al. (2017, "Parallel Methodology to Capture Cyclic Variability in Motored Engines,"Int. J. Engine Res., 18(4), pp. 366-377.) developed a parallel perturbation model (PPM) approach to dissociate this long time-scale problem into several shorter time-scale problems. This strategy was demonstrated for motored engine and it was shown that the mean and variance of the in-cylinder flow field was captured reasonably well by this approach. In the present study, this PPM approach is extended to simulate the CCV in a fired port-fuel injected (PFI) spark ignition (SI) engine. The predictions from this approach are also shown to be similar to the consecutive LES cycles. It is shown that the parallel approach is able to predict the coefficient of variation (COV) of the in-cylinder pressure and burn raterelated parameters with sufficient accuracy, and is also able to predict the qualitative trends in CCV with changing operating conditions. It is shown that this new approach is able to give accurate predictions of the CCV in fired engines in less than one-tenth of the time required for the conventional approach of simulating consecutive engine cycles.

Ameen, Muhsin M.↗

MODELING, IMPLEMENTATION AND CONTROL OF A CVT BASED PTO FOR A SMALL SCALE MHK-TURBINE IN LOW FLOW SPEED OPERATION

Modeling, implementation, field testing and control of a power takeoff (PTO) device equipped with a ball-type continuously variable transmission (B-CVT) for a small marine hydrokinetic (MHK) turbine deployed from a floating unmanned autonomous mobile catamaran platform is described. The turbine is a partially submerged multi-blade undershot waterwheel (USWW). A validated numerical torque model for the MHK turbine has been derived and a speed controller has been developed, implemented and tested in the field. The dependance of the power generated as a function of number and submergence level of turbine blades has been investigated and the number of blades that maximizes power production is determined. Bench and field testing in support of characterizing the power conversion capabilities of MHK turbine and PTO are described. Detailed results of the final torque and power coefficient models, the controls architecture, and the MHK turbine performance with varying numbers of blades are provided.

Pimentel, Hugo↗

Enhanced information content for three-dimensional localization and tracking using the double-helix point spread function with variable-angle illumination epifluorescence microscopy

The signal-to-noise ratio (SNR) and three-dimensional localization precision of a double helix point spread function (DH-PSF) can be significantly improved by applying variable-angle illumination epifluorescence microscopy (VAI, also commonly known as “pseudo-TIRF” or “quasi-TIRF”). In this paper, we performed a quantitative analysis of the dependence of SNR and localization precision on the number of measured photons and the incident angle for static particles under both low (at a planar index-matched interface) and high (within a porous silica matrix) fluorescent background conditions. We found that under noisier imaging conditions, the SNR and localization precision obtained using VAI are up to fivefold and threefold greater, respectively, than those obtained using epi-illumination. Finally and moreover, we demonstrate that the combination of DH-PSF and VAI can significantly improve the accuracy of the measured diffusion coefficient for mobile particles, even at a relatively large distance (50 μm) from the boundary of the optical cell.

42 ENGINEERING↗

Influence on Structural Loading of a Wave Energy Converter by Controlling Variable-Geometry Components and the Power Take-Off

Oceans are harsh environments and can impose significant loads on deployed structures. The deployment of wave energy converters (WECs) faces a design challenge with apparently contradictory goals. A WEC should be designed to maximize the energy absorbed while ensuring the operating wave condition does not exceed the failure limits of the device itself. Therefore, the loads endured by the support structure are a design constraint for the system. Adaptability to different sea states is, therefore, highly desirable. This work uses a WEC-Sim model of a variable-geometry oscillating wave energy converter (VGOSWEC) mounted on a support structure simulated under different wave scenarios. A VGOSWEC resembles a paddle pitching about a fixed hinge perpendicular to the incoming wave fronts. Therefore, the hinge experiences loads perpendicular to its axis as it maintains its position. The geometry of the VGOSWEC is varied by opening a series of controllable flaps on the pitching paddle when the structure experiences threshold loads. Because opening the flaps lets the waves transmit through the paddle, it is hypothesized that opening the flaps should result in load shedding at the base of the support structure. The load shedding is achieved by reducing the moments about the hinge axis. This work compares the hydrodynamic coefficients, natural periods, and response amplitude operators from completely closed to completely open configurations of the controllable flaps. The comparisons quantify the effects of letting the waves transmit through the VGOSWEC. This work shows that the completely open configuration can reduce the pitch and surge loads on the base of the support structure by as much as 80%. It was observed that at the paddle's resonance frequency, the loads on the structure increased substantially. This increase in loads can be mitigated by a rotational power take-off damping about the hinge axis. Changing the rotational power take-off damping was identified as an additional design parameter that can be used to control the loads experienced by the WEC's support structure.

fixed and floating structures↗

SU-E-T-22: A Deterministic Solver of the Boltzmann-Fokker-Planck Equation for Dose Calculation

Purpose: The Boltzmann-Fokker-Planck equation (BFPE) accurately models the migration of photons/charged particles in tissues. While the Monte Carlo (MC) method is popular for solving BFPE in a statistical manner, we aim to develop a deterministic BFPE solver based on various state-of-art numerical acceleration techniques for rapid and accurate dose calculation. Methods: Our BFPE solver is based on the structured grid that is maximally parallelizable, with the discretization in energy, angle and space, and its cross section coefficients are derived or directly imported from the Geant4 database. The physical processes that are taken into account are Compton scattering, photoelectric effect, pair production for photons, and elastic scattering, ionization and bremsstrahlung for charged particles.While the spatial discretization is based on the diamond scheme, the angular discretization synergizes finite element method (FEM) and spherical harmonics (SH). Thus, SH is used to globally expand the scattering kernel and FFM is used to locally discretize the angular sphere. As a Result, this hybrid method (FEM-SH) is both accurate in dealing with forward-peaking scattering via FEM, and efficient for multi-energy-group computation via SH. In addition, FEM-SH enables the analytical integration in energy variable of delta scattering kernel for elastic scattering with reduced truncation error from the numerical integration based on the classic SH-based multi-energy-group method. Results: The accuracy of the proposed BFPE solver was benchmarked against Geant4 for photon dose calculation. In particular, FEM-SH had improved accuracy compared to FEM, while both were within 2% of the results obtained with Geant4. Conclusion: A deterministic solver of the Boltzmann-Fokker-Planck equation is developed for dose calculation, and benchmarked against Geant4. Xiang Hong and Hao Gao were partially supported by the NSFC (#11405105), the 973 Program (#2015CB856000) and the Shanghai Pujiang Talent Program (#14PJ1404500)

60 APPLIED LIFE SCIENCES↗