Search NASA⌕ Search

SEARCH · Search NASA

Results for “'Interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

2D grating simulation for X-ray phase-contrast and dark-field imaging with a Talbot interferometer

Talbot interferometry is a recently developed and an extremely powerful X-ray phase-contrast imaging technique. Besides giving access to ultra-high sensitivity differential phase contrast images, it also provides the dark field image, which is a map of the scattering power of the sample. In this paper we investigate the potentialities of an improved version of the interferometer, in which two dimensional gratings are used instead of standard line grids. This approach allows to overcome the difficulties that might be encountered in the images produced by a one dimensional interferometer. Among these limitations there are the phase wrapping and quantitative phase retrieval problems and the directionality of the differential phase and dark-field signals. The feasibility of the 2D Talbot interferometer has been studied with a numerical simulation on the performances of its optical components under different circumstances. The gratings can be obtained either by an ad hoc fabrication of the 2D structures or by a superposition of two perpendicular linear grids. Through this simulation it has been possible to find the best parameters for a practical implementation of the 2D Talbot interferometer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design and implementation of a multichannel millimeter wave interferometer for the Compact Toroidal Hybrid experiment

A three-channel 1 mm wave interferometer has been designed, assembled, and installed on the Compact Toroidal Hybrid torsatron (CTH). The interferometer design makes novel use of a subharmonic mixer for detection, which simplifies alignment. It employs a single electronically tunable source that is repetitively chirped using a sawtooth waveform of frequency up to 1 MHz. The 15.25 GHz drive oscillator is multiplied in two stages to 122 GHz before a final doubler stage brings it to 244 GHz. Local oscillator (LO) power at 122 GHz is directed through waveguide to the LO input of the subharmonic mixer of each viewing chord, simplifying alignment. Phase detection is performed by directly digitizing the amplified mixer outputs at 50 MHz and processing them with a software algorithm. Initial measurements made with the central chord of the new interferometer agree with those from the existing 4 mm system at low densities. The 1 mm system performs well in current-driven discharges reaching densities over 10{sup 19} m{sup -3}, whereas the lower frequency interferometer is found to be less reliable due to loss of fringes. This is a critical improvement for experiments studying the onset, avoidance, and vacuum magnetic transform dependence of disruptions in the CTH device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An extreme ultraviolet Michelson interferometer for experiments at free-electron lasers

We present a Michelson interferometer for 13.5 nm soft x-ray radiation. It is characterized in a proof-of-principle experiment using synchrotron radiation, where the temporal coherence is measured to be 13 fs. The curvature of the thin-film beam splitter membrane is derived from the observed fringe pattern. The applicability of this Michelson interferometer at intense free-electron lasers is investigated, particularly with respect to radiation damage. This study highlights the potential role of such Michelson interferometers in solid density plasma investigations using, for instance, extreme soft x-ray free-electron lasers. A setup using the Michelson interferometer for pseudo-Nomarski-interferometry is proposed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The effect of losses on the quantum-noise cancellation in the SU(1,1) interferometer

Quantum-noise cancellation (QNC) is an effective method to control the noise of the quantum system, which reduces or even eliminates the noise of the quantum systems by utilizing destructive interference in the quantum system. However, QNC can be extremely dependent on the losses inside the system. In this letter, we experimentally and theoretically study how the losses can affect the QNC in the SU(1,1) interferometer. We find that losses in the different arms inside the SU(1,1) interferometer can have different effects on the QNC in the output fields from the SU(1,1) interferometer. And the QNC in the SU(1,1) interferometer can almost be insensitive to the losses in some cases. Our findings may find its potential applications in the quantum noise control.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental study of the mutual influence of fibre Faraday elements in a spun-fibre interferometer

An all-spun-fibre linear reflective interferometer with two linked Faraday fibre coils is studied. It is found experimentally that there is mutual influence of Faraday fibre coils in this interferometer. It manifests itself as an additional phase shift of the interferometer response, which depends on the circular birefringence induced by the Faraday effect in both coils. In addition, the interferometer contrast and magneto-optical sensitivity of one of the coils change. A probable physical mechanism of the discovered effect is the distributed coupling of orthogonal polarised waves in the fibre medium, which is caused by fibre bend in the coil. (interferometry)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multiple-beam fibre reflection interferometer based on an all-dielectric diffraction structure

We report experiments aimed at making a fibre reflection interferometer based on all-dielectric diffraction structures for the range 1500–1600 nm. The diffractive scattering structure of the input mirror of the interferometer is produced on the fibre end face by damaging it using abrasive diamond film with a grain size of a few microns. As a result, sharp reflection peaks are obtained for two interferometers, with the following parameters: finesse, 100 and 11; contrast, 2 and 60, respectively. Such an interferometer can, in principle, combine high contrast and high finesse. (laser applications and other topics in quantum electronics)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Scalable Bose-Einstein-condensate Sagnac interferometer in a linear trap

We demonstrate a two-dimensional atom interferometer in a harmonic magnetic waveguide using a Bose-Einstein condensate. Such an interferometer could measure rotation using the Sagnac effect. Compared to free space interferometers, larger interactions times and enclosed areas can in principle be achieved, since the atoms are not in free fall. In this implementation, we induce the atoms to oscillate along one direction by displacing the trap center. We then split and recombine the atoms along an orthogonal direction using an off-resonant optical standing wave. We enclose a maximum effective area of 0.1 mm{sup 2} limited by fluctuations in the initial velocity and by the coherence time of the interferometer. We argue that this arrangement is scalable to enclose larger areas by increasing the coherence time and then making repeated loops.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Atom Interferometers with Scalable Enclosed Area

Bloch oscillations (i.e., coherent acceleration of matter waves by an optical lattice) and Bragg diffraction are integrated into light-pulse atom interferometers with large momentum splitting between the interferometer arms, and hence enhanced sensitivity. Simultaneous acceleration of both arms in the same internal states suppresses systematic effects, and simultaneously running a pair of interferometers suppresses the effect of vibrations. Ramsey-Borde interferometers using four such Bloch-Bragg-Bloch beam splitters exhibit 15% contrast at 24(Planck constant/2pi)k splitting, the largest so far ((Planck constant/2pi)k is the photon momentum); single beam splitters achieve 88(Planck constant/2pi)k. The prospects for reaching 100 s of (Planck constant/2pi)k and applications such as gravitational wave sensors are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-410: Fringe Stability and Phase Shift Measurements in a Michelson Interferometer for Optical Calorimetry

Purpose: To identify the variables limiting the resolution of a Michelson interferometer used to measure phase shifts (PS) in water as part of a radiometric calorimeter. Methods: We investigated the output stability of a He-Ne laser and a laser diode. The short and long term stability of the fringe pattern in a Michelson interferometer was tested with different types of lasers, thermal insulation arrangements, damping systems and optical mounts to optimize system performance. PS were induced by electrically heating water in a 1 cm quartz cuvette located in one of the interferometer arms. The PS was calculated from fringe intensity changes and compared to a calculated PS using thermocouple-measured temperature changes in the water. Results: The intensity of the laser diode is more stable, but the gas laser’s profile is more suitable for fringe analysis and has better temporal coherence. The laser requires a warm-up time of 4 hours before its output is stabilized (SNR>95). The fringe’s stability strongly depends on the thermal insulation. When the interferometer is exposed to ambient temperature swings of 0.7 K, it is not possible to stabilize the fringe pattern. Enclosing the system in a 2.5 cm-thick Styrofoam box improves the SNR, but further insulation will be needed to increase the SNR above 50. High frequency noise is significantly reduced by damping the system.Inducing a temperature rise in water, starting at 299 K, the average temperature increase for a 2π PS is 0.29 ± 0.02 K and the proportionality constant is -21.1 ± 0.8 radians/K. This is 5.8% lower than the calculated value using the thermocouple. Conclusion: Interferometric PS measurements of temperature may provide an alternative to thermistors for water calorimetry. The resolution of the current prototype is limited by ambient temperature stability. Calculated and measured thermally-induced PS in water agreed to within 5.8%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prism-pair interferometry by homodyne interferometers with a common light source for high-accuracy measurement of the absolute refractive index of glasses

A prism-pair interferometer comprising two homodyne interferometers with a common light source was developed for high-precision measurements of the refractive index of optical glasses with an uncertainty of the order of 10{sup -6}. The two interferometers measure changes in the optical path length in the glass sample and in air, respectively. Uncertainties in the absolute wavelength of the common light source are cancelled out by calculating a ratio between the results from the interferometers. Uncertainties in phase measurement are suppressed by a quadrature detection system. The combined standard uncertainty of the developed system is evaluated as 1.1x10{sup -6}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Designs of multipass optical configurations based on the use of a cube corner retroreflector in the interferometer

We describe designs of the multipass optical configurations of an interferometer with high spectral resolution with respect to 6, 12, and 24 times more optical passes than the conventional Michelson interferometer. In each design, a movable cube corner retroreflector is combined with a folding reflector group (FRG) as the interferometer's moving combination to implement the multipass optical configuration with the characteristic of surface division. Analyses reveal that when there are 12 or more optical passes, the net effect of the ray's angular deviation of the entire moving combination amounts to only the alignment error of one of the reflectors in the FRG, demonstrating the self-aligning property of the interferometer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The StarLight Space Interferometer: Optical design and performance modeling

The StarLight mission aimed to place the first formation flying optical interferometer into space in year 2006. Utilizing two spacecraft to form a long baseline Michelson interferometer, it would measure white light fringes on a number of partially resolved stars of magnitudes >5 in the wavelength range 600 to 1000nm. The interferometer baseline is variable between 30 and 125 m, and also has a fixed 1 m mode. The spacecraft are flown in a parabolic geometry which requires an optical delay line to build up more than 14m of delay on one arm of the interferometer. To obtain high fringe visibility, starlight wavefront, pointing and intensity must be preserved through 22 reflections from mirrors and beamsplitters. The alignment of a total of 27 optics is maintained through careful thermal design and the use of two actuated mirrors on each arm. This paper describes the optical layout in depth, including the beam combiner design which allows star tracking, optical system alignment and fringe formation on a single CCD. The effects of diffraction of the starlight transferred from a distant spacecraft and from optical surface imperfections are modeled. Other contributors to the visibility budget and the resulting variation of fringe visibility across the focal plane are discussed .

StarLight↗

A novel heterodyne displacement interferometer with no detectable periodic nonlinearity and optical resolution doubling

This paper describes a novel heterodyne laser interferometer with no significant periodic nonlinearity for linear displacement measurements. Moreover, the optical configurations have the benefit of doubling the measurement resolution when compared to its respective traditional counterparts. Experimental results show no discernable periodic nonlinearity for a retro-reflector interferometer and plane mirror interferometer configurations with a noise level below 20 pm. The incoming laser beams of the interferometers are achieved by utilizing two single mode optical fibers. To determine the stability of the optical fiber couplers a fiber delivery prototype was also built and tested.

42 ENGINEERING↗

Spatially translatable optical fiber-coupled heterodyne interferometer

An interferometer is a useful diagnostic tool for measuring line-averaged electron density but is limited in its use because it generally measures at a fixed location. Here, we report here a spatially translatable fiber-coupled interferometer that measures the density of a high-speed MHD-driven plasma jet colliding with a target cloud. The interferometer uses a He–Ne laser coupled to a polarization-maintaining single mode optical fiber having a vacuum feedthrough. Lastly, the interferometer provides a measure of the spatial-temporal profile of the line-averaged electron density from which the change in jet velocity as a result of its collision with the target cloud can be deduced.

47 OTHER INSTRUMENTATION↗

Slow Quasiparticle Dynamics and Anyonic Statistics in a Fractional Quantum Hall Fabry-Pérot Interferometer

Anyons are two-dimensional particles with fractional exchange statistics that emerge as elementary excitations of fractional quantum Hall phases. Experimentally, their exchange statistics can be measured in the edge-state Fabry-Pérot interferometer, wherein the presence of 𝑁 𝑞⁢𝑝 localized anyons contributes a phase 𝑁 𝑞⁢𝑝⁢ 𝜃 𝑎 to the interference pattern where 𝜃 𝑎 is twice the exchange phase. Here we report the observation of large, hysteretic phase jumps in a monolayer graphene Fabry-Pérot interferometer at 𝜈 = 1/3. When the filling factor is increased from 𝜈 < 1/3 toward the center of the plateau, we observe phase slips with magnitude Δ⁢𝜃 ≈ 2⁢𝜋/3, consistent with the addition of individual quasiparticles to the interferometer bulk. These phase slips occur as instantaneous jumps in the interference signal, with intervals between the jumps indicating quasiparticle equilibration times exceeding 20 min. We use this long timescale to investigate the effect of changes in interferometer area 𝐴 𝐼 and 𝑁 𝑞⁢𝑝 independently at fixed magnetic field, revealing a striking memory effect in the phase slip magnitude. In particular, as the 𝜈 =1/3 plateau is approached from higher filling, we observed phase slips with Δ⁢𝜃 significantly larger than 2⁢𝜋/3 over the same range of gate voltage where quantized jumps are seen for increasing 𝜈. We discuss this asymmetry in terms of bulk-edge coupling of quasiparticles localized near the edge or in the bulk, and argue that this effect can be qualitatively reconciled with theoretical expectations for strongly interacting quasiparticles in the presence of weak disorder and strongly nonequilibrium charge dynamics. Besides providing a replication of interferometric measurements sensitive to 𝜃 𝑎 , our results highlight the key role played by charge dynamics on signatures of the anyon phase, and demonstrate that fractional quasiparticles can be indefinitely localized in nonequilibrium configurations.

anyons↗

Dynamical quantum phase transitions in interacting atomic interferometers

Particle-wave duality has allowed physicists to establish atomic interferometers as celebrated complements to their optical counterparts in a broad range of quantum devices. In particular, interactions give rise to multiparticle correlations unavailable in linear interferometers. Here, we show that interactions lead to dynamical quantum phase transitions (DQPTs) between NOON states in an atomic interferometer. These transition points result from zeros of the Loschmidt echo, which approach the real axis of the complex time plane in the large-particle-number limit, and signify pair condensates, another type of exotic quantum states featured with prevailing two-body correlations. Such DQPTs thus provide us with a new angle to understand many-body states emergent from quantum nonequilibrium dynamics. Further, our work also suggests interacting atomic interferometers as a new tool for creating highly entangled states to beat the standard quantum limit.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron interferometer crystallographic imperfections and gravitationally induced quantum interference measurements

Dynamical diffraction leads to an interesting, unavoidable set of interference effects for neutron interferometers. This experiment studies the interference signal from two and three successive Bragg diffractions in the Laue geometry. We find that intrinsic Bragg-plane misalignment in monolithic, “perfect” silicon neutron interferometers is relevant between successive diffracting crystals, as well as within the Borrmann fan for typical interferometer geometries. Furthermore, we show that the dynamical phase correction employed in the Colella, Overhauser, and Werner gravitationally induced quantum interference experiments is attenuated by slight, intrinsic misalignments between diffracting crystals, potentially explaining the long-standing 1% discrepancy between theory and experiment. This systematic may also impact precision measurements of the silicon structure factor, affecting previous and future measurements of the Debye-Waller factor and neutron-electron scattering length as well as potential fifth-force searches. For the interferometers used in this experiment, Bragg planes of different diffracting crystals were found to be misaligned by 10 to 40 nrad.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Interferometer response to geontropic fluctuations

We model vacuum fluctuations in quantum gravity with a scalar field, characterized by a high occupation number, coupled to the metric. The occupation number of the scalar is given by a thermal density matrix, whose form is motivated by fluctuations in the vacuum energy, which have been shown to be conformal near a light-sheet horizon. For the experimental measurement of interest in an interferometer, the size of the energy fluctuations is fixed by the area of a surface bounding the volume of spacetime being interrogated by an interferometer. We compute the interferometer response to these “geontropic” scalar-metric fluctuations, and apply our results to current and future interferometer measurements, such as LIGO and the proposed GQuEST experiment.

79 ASTRONOMY AND ASTROPHYSICS↗