Search NASA⌕ Search

SEARCH · Search NASA

Results for “2 column instrument”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Improved Satellite Retrievals of NO2 and SO2 over the Canadian Oil Sands and Comparisons with Surface Measurements

Satellite remote sensing is increasingly being used to monitor air quality over localized sources such as the Canadian oil sands. Following an initial study, significantly low biases have been identified in current NO2 and SO2 retrieval products from the Ozone Monitoring Instrument (OMI) satellite sensor over this location resulting from a combination of its rapid development and small spatial scale. Air mass factors (AMFs) used to convert line-of-sight "slant" columns to vertical columns were re-calculated for this region based on updated and higher resolution input information including absorber profiles from a regional-scale (15 km × 15 km resolution) air quality model, higher spatial and temporal resolution surface reflectivity, and an improved treatment of snow. The overall impact of these new Environment Canada (EC) AMFs led to substantial increases in the peak NO2 and SO2 average vertical column density (VCD), occurring over an area of intensive surface mining, by factors of 2 and 1.4, respectively, relative to estimates made with previous AMFs. Comparisons are made with long-term averages of NO2 and SO2 (2005-2011) from in situ surface monitors by using the air quality model to map the OMI VCDs to surface concentrations. This new OMI-EC product is able to capture the spatial distribution of the in situ instruments (slopes of 0.65 to 1.0, correlation coefficients of greater than 0.9). The concentration absolute values from surface network observations were in reasonable agreement, with OMI-EC NO2 and SO2 biased low by roughly 30%. Several complications were addressed including correction for the interference effect in the surface NO2 instruments and smoothing and clear-sky biases in the OMI measurements. Overall these results highlight the importance of using input information that accounts for the spatial and temporal variability of the location of interest when performing retrievals.

surface concentration↗

Top-Down NOx Emissions of European Cities Based on the Downwind Plume of Modelled and Space-Borne Tropospheric NO2 Columns

Top-down estimates of surface NOX emissions were derived for 23 European cities based on the downwind plume decay of tropospheric nitrogen dioxide (NO2) columns from the LOTOS-EUROS (Long Term Ozone Simulation-European Ozone Simulation) chemistry transport model (CTM) and from Ozone Monitoring Instrument (OMI) satellite retrievals, averaged for the summertime period (April-September) during 2013. Here we show that the top-down NOX emissions derived from LOTOS-EUROS for European urban areas agree well with the bottom-up NOX emissions from the MACC-III inventory data (R(exp 2) = 0.88) driving the CTM demonstrating the potential of this method. OMI top-down NOX emissions over the 23 European cities are generally lower compared with the MACC-III emissions and their correlation is slightly lower (R(exp 2) = 0.79). The uncertainty on the derived NO2 lifetimes and NOX emissions are on average ~55% for OMI and ~63% for LOTOS-EUROS data. The downwind NO2 plume method applied on both LOTOS-EUROS and OMI tropospheric NO2 columns allows to estimate NOX emissions from urban areas, demonstrating that this is a useful method for real-time updates of urban NOX emissions with reasonable accuracy.

NOx emissions↗

Tunable Infrared Laser Absorption Spectroscopy of Aluminum Monoxide $A^2\Pi_i $–$X^2\Sigma^+$.

We report the details of an infrared, laser absorption diagnostic capable of quantifying aluminum monoxide temperature and column density at 100 kHz repetition rate. This novel technique employs a near infrared MEMS-VCSEL to measure rotationally resolved optical absorption spectra of aluminum monoxide $A^2\Pi_i$ - $X^2\Sigma^+$ from approximately 7400 –7900 cm -1 . Temperatures and column densities are extracted from model regressions to provide temporally resolved thermochemical information on aluminum oxidation reactions. The measurement capability is demonstrated by performing 100 kHz measurement in the plume of an exploding bridgewire with measured temperatures of 3450–3100 K and column densities of 1– 11 x 10 16 cm -2 . To the authors knowledge, this is the first use of the AlO $A^2\Pi_i$ - $X^2\Sigma^+$ transition to characterize aluminum combustion environments. Details regarding signal extraction and calibration of MEMS-VCSEL spectra are also included. Although unsuccessful, efforts to extract kinetic temperature and column density from simultaneously measured, atomic aluminum 2 P 3/2,1/2 - 2 S 1/2 transitions at 7618 cm -1 and 7602 cm -1 are also described.

47 OTHER INSTRUMENTATION↗

3D Cloud Aerosol Precipitation Experiment at kennaook Cape Grim (3D-CAPE-k) Field Campaign Report

The objective of this campaign was to complement the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) User Facility’s Cloud And Precipitation Experiment at kennaook (CAPE-k) in northwest Tasmania by deploying scanning, fixed pointing angle, and in situ aerosol, cloud, and precipitation remote-sensing instruments during the last six months of the experiment. These instruments provided a three-dimensional (3D) context to the second ARM Mobile Facility (AMF2) vertically pointing observations collected at the kennaook Cape Grim (KCG) site and captured a portion of the life cycle of the clouds before and after the passage over the AMF2 vertical column. These 3D cloud measurements will be used in the near future to 1) investigate how the vertical profiles of aerosol and cloud properties are representative of the broader area and how these properties evolve during the portion of the cloud life cycle captured by the scanning instruments, 2) quantify how accurate the cloud fraction derived with assumptions from vertically pointing observations are compared with direct 3D cloud fraction measurements, 3) evaluate cloud fraction and liquid water path in the Australian Community Climate and Earth-System Simulator–Convective-scale (ACCESS-C) forecast model, and 4) evaluate aerosol and cloud products from the European Space Agency/Japanese Aerospace Exploration Agency (ESA/JAXA) Earth Cloud Aerosol Radiation Explorer (EarthCARE) mission using the scanning measurements, offering more chances of exact collocation, thereby complementing the statistical approach we are planning to employ with AMF2 observations for that same purpose.

54 ENVIRONMENTAL SCIENCES↗

The NASA participation in the 1980 EPA PEPE/NEROS field measurements program

The Persistent Elevated Pollution Episode (PEPE)/Northeast Regional Oxidant Study (NEROS) Project consisted of a series of field measurements sponsored by the EPA during July and August, 1980. NASA participation in the Project had several purposes: (1) use remote sensing to help determine mixed layer height and ozone profiles regionally; and (2) provide opportunity for development, testing and evaluation of several NASA 'emerging' airborne remote sensing systems. NASA also provided information on the hazy pollution episodes throughout the summer of 1980 with satellite imagery. This paper describes findings on atmospheric aerosols, ozone profile and ozone column and discusses the instruments (airborne and ground-based sensors) and techniques used to obtain the relevant data. Associated archived data is also discussed.

Remsberg, E.↗

Nimbus 7 solar backscatter ultraviolet (SBUV) ozone products user's guide

Three ozone tape products from the Solar Backscatter Ultraviolet (SBUV) experiment aboard Nimbus 7 were archived at the National Space Science Data Center. The experiment measures the fraction of incoming radiation backscattered by the Earth's atmosphere at 12 wavelengths. In-flight measurements were used to monitor changes in the instrument sensitivity. Total column ozone is derived by comparing the measurements with calculations of what would be measured for different total ozone amounts. The altitude distribution is retrieved using an optimum statistical technique for the inversion. The estimated initial error in the absolute scale for total ozone is 2 percent, with a 3 percent drift over 8 years. The profile error depends on latitude and height, smallest at 3 to 10 mbar; the drift increases with increasing altitude. Three tape products are described. The High Density SBUV (HDSBUV) tape contains the final derived products - the total ozone and the vertical ozone profile - as well as much detailed diagnostic information generated during the retrieval process. The Compressed Ozone (CPOZ) tape contains only that subset of HDSBUV information, including total ozone and ozone profiles, considered most useful for scientific studies. The Zonal Means Tape (ZMT) contains daily, weekly, monthly and quarterly averages of the derived quantities over 10 deg latitude zones.

Fleig, Albert J.↗

The Sensitivity of U.S. Surface Ozone Formation to NOx, and VOCs as Viewed from Space

We investigated variations in the sensitivity of surface ozone formation in summer to precursor species concentrations of volatile organic compounds (VOCs) and nitrogen oxides (NO(x)) as inferred from the ratio of tropospheric columns of formaldehyde and nitrogen dioxide from the Aura Ozone Monitoring Instrument (OMI). The data indicate that ozone formation became: 1. more sensitive to NO(x) over most of the U.S, from 2005 to 2007 because of substantial decreases in NO(x) emissions primarily from stationary sources, and 2. more sensitive to NO(x) with increasing temperature, in part because emissions of highly reactive, biogenic isoprene increase with temperature, thus increasing the total VOC reactivity. Based on our interpretation of the data, current strategies implemented to reduce unhealthy levels of surface ozone should focus more on reducing NO(x) emissions, except in some downtown areas which have historically benefited from reductions in VOC emissions.

Duncan, Bryan N.↗

Has NO(2) in Metropolitan Areas Returned to Pre-COVID-19 Levels as Measured by OMI Satellite Data?

Nitrogen oxides (NOx = NO + NO2) are primarily emitted through the combustion of fossil fuels, such as automobiles and power plants. NOx can contribute to chemical reactions that produce ozone and fine particulate matter (PM2.5) pollution. Using tropospheric vertical column density (TVCD) NO2 data from satellite hyperspectral instruments, such as the Ozone Monitoring Instrument (OMI) on board NASA’s EOS Aura satellite, one can monitor changes in NO2 pollution during “black-swan” events, such as mobility restrictions during COVID-19 lockdowns. Our OMI team has created the Global Nitrogen Dioxide Monitoring Home Page (https://so2.gsfc.nasa.gov/no2/no2_index.html ) where we display NO2 TVCD time series, animated maps, and COVID-specific NO2 anomalies comparing to a pre-COVID five-year average for 317 cities and regions around the world. During the pandemic as a result of the widespread lockdowns, many areas saw low NO2 anomalies superimposed on the natural weather related NO2 changes, such as seasonal NO2 cycle. Has NO2 levels returned to pre-Covid-19 levels in large metropolitan areas? We analyze NO2 time series from March through September for the years 2020-2023 using as a reference the average NO2 from 2015-2019 for those months. We will present data from selected cities that represent all countries.

Keith D Evans↗

Airborne Sunphotometer Measurements of Aerosol Optical Depth and Water Vapor in ACE-Asia and Their Comparisons to Correlative Measurements

In the Spring 2001 phase of the Asian Pacific Regional Aerosol Characterization Experiment (ACE-Asia), the 6-channel NASA Ames Airborne Tracking Sunphotometer (AATS-6) operated on 15 of the 19 research flights of the NCAR C-130, while its 14-channel counterpart (AATS-14) flew successfully on all 19 research flights of the CIRPAS Twin Otter. ACE-Asia studied aerosol outflow from the Asian continent to the Pacific basin. It was designed to integrate suborbital and satellite measurements and models to reduce the uncertainty in calculations of the climate forcing due to aerosols. AATS-6 and AATS-14 measured solar beam transmission at six and 14 wavelengths (380-1021 and 354-1558 nm, respectively), yielding aerosol optical depth (AOD) spectra and columnar water vapor (CWV). Vertical differentiation in profiles yielded aerosol extinction spectra and water vapor concentration. In this paper, we plan to present examples of the following, preliminary findings that are based in part on our airborne sunphotometer measurements: (1) The wavelength dependence of sunphotometer-derived AOD and extinction indicates that supermicron dust was often a major component of the aerosol, frequently extending to high altitudes. The percentage of full-column AOD (525 nm) that Jay above 3 km was typically 34+/-13%. In contrast, the analogous percentage of columnar water vapor was only 10+/-4%; (2) Initial comparison studies between AOD data obtained by AATS-6 and AATS-14 during coordinated low-level flight legs show agreement well within the instruments' error bars; (3) Aerosol extinction has been derived from airborne in situ measurements of scattering (nephelometers) and absorption (particle soot/ absorption photometer, PSAP) or calculated from particle size distribution measurements (mobility analyzers and aerodynamic particle sizers). Comparison with corresponding extinction values derived from the Ames airborne sunphotometer measurements shows good agreement for the vertical distribution of aerosol layers. However, the level of agreement in absolute magnitude of the derived aerosol extinction/optical depth varied among the aerosol layers sampled; (4) Initial comparisons of sunphotometer and satellite-derived AOD using SeaWiFS, MISR and AVHRR show promising results. We also plan to include comparisons with MODIS and TOMS: (5) Initial comparisons of sunphotometer-derived AOD and aerosol extinction profiles with lidars in Tokyo and on a ship show reasonable agreement.

Schmid, B.↗

Satellite Remote-Sensing Capability to Assess Tropospheric-Column Ratios of Formaldehyde and Nitrogen Dioxide: Case Study During the Long Island Sound Tropospheric Ozone Study 2018 (LISTOS 2018) Field Campaign

Satellite retrievals of tropospheric-column formaldehyde (HCHO) and nitrogen dioxide (NO 2 ) are frequently used to investigate the sensitivity of ozone (O 3 ) production to emissions of nitrogen oxides and volatile organic carbon compounds. This study inter-compared the systematic biases and uncertainties in retrievals of NO 2 and HCHO, as well as resulting HCHO–NO 2 ratios (FNRs), from two commonly applied satellite sensors to investigate O 3 production sensitivities (Ozone Monitoring Instrument, OMI, and TROPOspheric Monitoring Instrument, TROPOMI) using airborne remote-sensing data taken during the Long Island Sound Tropospheric Ozone Study 2018 between 25 June and 6 September 2018. Compared to aircraft-based HCHO and NO 2 observations, the accuracy of OMI and TROPOMI were magnitude-dependent with high biases in clean environments and a tendency towards more accurate comparisons to even low biases in moderately polluted to polluted regions. OMI and TROPOMI NO 2 systematic biases were similar in magnitude (normalized median bias, NMB = 5 %–6 %; linear regression slope ≈ 0.5–0.6), with OMI having a high median bias and TROPOMI resulting in small low biases. Campaign-averaged uncertainties in the three satellite retrievals (NASA OMI; Quality Assurance for Essential Climate Variables, QA4ECV OMI; and TROPOMI) of NO 2 were generally similar, with TROPOMI retrievals having slightly less spread in the data compared to OMI. The three satellite products differed more when evaluating HCHO retrievals. Campaign-averaged tropospheric HCHO retrievals all had linear regression slopes ∼0.5 and NMBs of 39 %, 17 %, 13 %, and 23 % for NASA OMI, QA4ECV OMI, and TROPOMI at finer (0.05° x 0.05°) and coarser (0.15° x 0.15°) spatial resolution, respectively. Campaign-averaged uncertainty values (root mean square error, RMSE) in NASA and QA4ECV OMI HCHO retrievals were ~9.0 x 10 15 molecules cm –2 (∼ 50 %–55 % of mean column abundance), and the higher-spatial-resolution retrievals from TROPOMI resulted in RMSE values ∼30 % lower. Spatially averaging TROPOMI tropospheric-column HCHO, along with NO 2 and FNRs, to resolutions similar to the OMI reduced the uncertainty in these retrievals. Systematic biases in OMI and TROPOMI NO 2 and HCHO retrievals tended to cancel out, resulting in all three satellite products comparing well to observed FNRs. However, while satellite-derived FNRs had minimal campaign-averaged median biases, unresolved errors in the indicator species did not cancel out in FNR calculations, resulting in large RMSE values compared to observations. Uncertainties in HCHO retrievals were determined to drive the unresolved biases in FNR retrievals.

Matthew S. Johnson↗

M2-SCREAM: A Stratospheric Composition Reanalysis of Aura MLS Data With MERRA-2 Transport

MERRA-2 Stratospheric Composition Reanalysis of Aura Microwave Limb Sounder (M2-SCREAM) is a new reanalysis of stratospheric ozone, water vapor, hydrogen chloride (HCl), nitric acid (HNO 3 ) and nitrous oxide (N 2 O) between 2004 and the present (with a latency of several months). The assimilated fields are provided at a 50-km horizontal resolution and at a three-hourly frequency. M2-SCREAM assimilates version 4.2 Microwave Limb Sounder (MLS) profiles of the five constituents alongside total ozone column from the Ozone Monitoring Instrument. Dynamics and tropospheric water vapor are constrained by the MERRA-2 reanalysis. The assimilated species are in excellent agreement with the MLS observations, except for HNO 3 in polar night, where data are not assimilated. Comparisons against independent observations show that the reanalysis realistically captures the spatial and temporal variability of all the assimilated constituents. In particular, the standard deviations of the differences between M2-SCREAM and constituent mixing ratio data from The Atmospheric Chemistry Experiment Fourier Transform Spectrometer are much smaller than the standard deviations of the measured constituents. Evaluation of the reanalysis against aircraft data and balloon-borne frost point hygrometers indicates a faithful representation of small-scale structures in the assimilated water vapor, HNO 3 and ozone fields near the tropopause. Comparisons with independent observations and a process-based analysis of the consistency of the assimilated constituent fields with the MERRA-2 dynamics and with large-scale stratospheric processes demonstrate the utility of M2-SCREAM for scientific studies of chemical and transport variability on time scales ranging from hours to decades. Analysis uncertainties and guidelines for data usage are provided.

MERRA-2↗

Investigation of NO2 Measurements Made During DISCOVER-AQ and KORUS-AQ Campaigns in Conjunction with NO2 Tropospheric Column from the Ozone Monitoring Instrument (OMI) and High-Resolution Community Multi-Scale Air Quality (CMAQ) Model Simulation

Atmospheric NO2 is produced by combustion, lightning, and in soil. NO2 affects ozone production and criteria pollutant itself.It also has indirect radiative impacts in the troposphere, since ozone has largest warming effect in upper troposphere. Tropospheric vertical column densities (VCD) of NO2 are available from satellites (GOME, OMI, SCIAMACHY, GOME-2). DISCOVER-AQ and KORUS-AQ aircraft campaigns we reconducted to improve the use of satellites to monitor air quality for public health and environmental benefit in United States and South Korea. In this study, we investigate 1) How do these measurements compare? 2) What is the best way to make comparisons of space- and ground-based measurements?

multi-scale air quality↗

Nimbus-7 Total Ozone Mapping Spectrometer (TOMS) data products user's guide

Two tape products from the Total Ozone Mapping Spectrometer (TOMS) aboard the Nimbus-7 have been archived at the National Space Science Data Center. The instrument measures backscattered Earth radiance and incoming solar irradiance; their ratio -- the albedo -- is used in ozone retrievals. In-flight measurements are used to monitor changes in the instrument sensitivity. The algorithm to retrieve total column ozone compares the observed ratios of albedos at pairs of wavelengths with pair ratios calculated for different ozone values, solar zenith angles, and optical paths. The initial error in the absolute scale for TOMS total ozone is 3 percent, the one standard-deviation random error is 2 percent, and the drift is +/- 1.5 percent over 14.5 years. The High Density TOMS (HDTOMS) tape contains the measured albedos, the derived total ozone amount, reflectivity, and cloud-height information for each scan position. It also contains an index of SO2 contamination for each position. The Gridded TOMS (GRIDTOMS) tape contains daily total ozone and reflectivity in roughly equal area grids (110 km in latitude by about 100-150 km in longitude). Detailed descriptions of the tape structure and record formats are provided.

Mcpeters, Richard D.↗

Science Objectives of EOS-Aura's Ozone Monitoring Instrument (OMI)

OMI is a UV/VIS nadir solar backscatter spectrograph, which provides near global coverage in one day with a spatial resolution of 13 x 24 sq km. OMI is a new instrument, with a heritage from the European satellite instruments GOME, GOMOS and SCIAMACHY. OMI's unique capabilities for measuring important trace gases with a small footprint and daily global coverage, in conjunction with the other Aura instruments, will make a major contribution to our understanding of stratospheric and tropospheric chemistry and climate change. OMI will measure solar irradiance and Earth radiances in the wavelength range of 270 to 500 nm with spectral resolution of about 0.5 nm and a spectral sampling of about 2-3 per FWHM. From these observations, total columns of O3, NO2, BrO and SO2 will be derived from the back-scattered solar radiance using differential absorption spectroscopy (DOAS). The TOMS total ozone record will also be continued by employing the well established TOMS algorithm. Because of the high accuracy and spatial resolution of the measurements, a good estimate of tropospheric amounts of ozone and NO2 are expected. Ozone profiles will be derived using the optimal estimation method. The spectral aerosol optical depth will be determined from measurements between 340 and 500 nm. This will provide information on aerosol concentration, aerosol size distribution and aerosol type. This wavelength range makes it possible to retrieve aerosol information over both land and sea. OMI observations will also allow retrievals of cloud coverage and cloud heights. From these products, the UV-B flux at the surface can then be derived with high spatial resolution.

Levelt, P. F.↗

University of Washington Airborne Studies in Support of the CLAMS-2001 Field Study

The main activity under this grant was participation in the Chesapeake Lighthouse and Aircraft Measurements for Satellites (CLAMS) field study from 10 July through 2 August 2001. The Cloud and Aerosol Research Group (CARG) from the University of Washington (UW) flew its Convair-580 research aircraft on thirteen occasions, for a total of 45 research flight hours, in support of CLAMS. Some of the main accomplishments of these flights were: 1) Aerosol and trace gas measurements and sunphotometer measurements of aerosol optical depth and column water vapor and ozone from close to Ocean surface to approx. 10,000 ft off Delmarva Peninsula on various occasions; 2) Measurements of aerosol properties on seven occasions beneath the Terra satellite, once beneath AVHRR, and five times beneath the ER-2 aircraft; 3) Measurements of aerosol properties in the vicinity of the (CERES instrumented) Chesapeake Bay lighthouse (COVE) on nine occasions; 4) Use of the NASA Goddard Cloud Absorption Radiometer (CAR) to obtain measurements of BRDF of the ocean surface on fifteen occasions and over Great Dismal Swamp on two occasions; 5) Measurements of aerosol properties over instrumented buoys 44014, 44004, and 41001. 6) On July 17 (a CLAMS 'Golden Day') six aircraft, including the Convair-580 and ER-2, were stacked above the Chesapeake Bay lighthouse under clear skies at the time of the Terra overpass.

Hobbs, Peter V.↗

Detecting Organic Compounds in Martian Soil Analogues Using Gas Chromatography Mass Spectrometry

One of the primary objectives of the 1976 Viking missions was to determine whether organic compounds, possibly of biological origin, were present in the Martian surface soils. The Viking gas chromatography mass spectrometry (GCMS) instruments found no evidence for any organic compounds of Martian origin above a few parts per billion in the upper 10 cm of surface soil [l], suggesting the absence of a widely distributed Martian biota. However, Benner et d. have suggested that significant amounts of non-volatile organic compounds, possibly including oxidation products of bioorganic molecules (e.g. carboxylic acids) would not have been detected by the Viking GCMS [2]. Moreover, other key organic compounds important to biology, such as amino acids and nucleobases, would also likely have been missed by the Viking GCMS as these compounds require chemical derivatization to be stable in a GC column [3]. Recent pyrolysis experiments with a Mars soil analogue that had been innoculated with Escherichia coli bacteria have shown that amino acid decomposition products (amines) and nucleobases are among the most abundant products generated after pyrolysis of the bacterial cells [4,5]. At the part per billion level (Viking GCMS detection limit), these pyrolysis products generated from several million bacterial cells per gram of Martian soil would not have been detected by the Viking GCMS instruments [4]. Analytical protocols are under development for upcoming in situ lander opportunities to target several important biological compounds including amino acids and nucleobases. For example, extraction and chemical derivatization techniques [3] are being adapted for space flight use to transform reactive or fragile molecules that would not have been detected by the Viking GCMS instruments, into species that are sufficiently volatile to be detected by GCMS. Recent experiments carried out at NASA Goddard have shown that using this derivatization technique all of the targeted compounds mentioned above can be separated on a GC column and detected by MS at sub-picomole (< 10(exp -l2 mole) levels. With these methods, the detection limit for amino acids, carboxylic acids and nucleobases is several orders of magnitude more sensitive than the Viking GCMS instruments for these compounds. Preliminary results using this analytical technique on a variety of Martian soil analogues will be presented.

Glavin, D. P.↗

Two-year moored instrument results along 152 deg E

Results from a 2-year (nominal) deployment of a moored array along 152 deg E from 28 deg N to 41 deg N are presented, with emphasis on similarities and differences between settings (approximately year-to-year). Ten moorings and 38 instruments were involved, from the fall of 1980 to 1982. Current-temperature meters spanned the water column from 500- to 4000-m depths, with occasional instruments in the vicinity of 300 m and near the bottom (about 6000 m). Upper level features located in the center of the array near 35-36 deg N were generally stable relative to the axis of the Kuroshio Extension, varying from deployment to deployment with meanders in this flow regime. Some properties of the abyssal (about 4000 m) currents were comparatively more variable, with these changes not connected to meandering of the Kuroshio Extension in an obvious way. The vertical structure and frequency distributions of eddy kinetic energy were similar in shape and to some extent in amplitude from deployment to deployment, especially relative to meanders of the Kuroshio Extension, but translated in the opposite direction.

Schmitz, William J., Jr.↗

Development of a Coherent Differential Absorption Lidar for Range Resolved Atmospheric CO2 Measurements

A pulsed, 2-m coherent Differential Absorption Lidar (DIAL) / Integrated Path Differential Absorption (IPDA) transceiver, developed under the Laser Risk Reduction Program (LRRP) at NASA, is integrated into a fully functional lidar instrument. This instrument will measure atmospheric CO2 profiles (by DIAL) initially from a ground platform, and then be prepared for aircraft installation to measure the atmospheric CO2 column densities in the atmospheric boundary layer (ABL) and lower troposphere. The airborne prototype CO2 lidar can measure atmospheric CO2 column density in a range bin of 1km with better than 1.5% precision at horizontal resolution of less than 50km. It can provide the image of the pooling of CO2 in lowlying areas and performs nighttime mass balance measurements at landscape scale. This sensor is unique in its capability to study the vertical ABL-free troposphere exchange of CO2 directly. It will allow the investigators to pursue subsequent in science-driven deployments, and provides a unique tool for Active Sensing of CO2 Emissions over Night, Days, and Seasons (ASCENDS) validation that was strongly advocated in the recent ASCENDS Workshop.

Yu, Jirong↗