Search NASA⌕ Search

SEARCH · Search NASA

Results for “3d imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

High-Energy X-ray Diffraction Microscopy for Nuclear Forensics (FY23 Project Report)

Morphological information on nuclear material has been identified using visible light and scanning electron microscopy. These identify qualitative differences in particle morphology. Three-dimensional imaging of materials through alternating scanning electron microscopy imaging and focused ion beam milling has also been used. Unfortunately, these techniques are time- and labor-intensive, with significant sample preparation required and lengthy analysis times. Further, the resulting 3D images are qualitative, require manual identification, and do not capture statistically-representative populations. High energy X-ray 3D imaging using a direct-beam or diffracted-beam (High-Energy Diffraction Microscopy) have been developed at the Advanced Photon Source and can produce quantitative information on grains (phase, location, etc.) and pores (size distribution, sphericity) in a material. These techniques require only minutes to characterize a sample volume and are non-destructive, thus suitable for a wide range of existing samples and for confirmatory analyses to be carried out using conventional microscopy techniques.

36 MATERIALS SCIENCE↗

Understanding FLiNaK Salt Intrusion Behavior on Nuclear-Grade Graphite via Neutron Tomography

Graphite is an essential material as a neutron moderator in molten salt reactors (MSRs). To understand the impact of salt on the graphite structure to develop structural materials for MSRs, molten salt intrusion behavior on nuclear-grade graphite was studied. The graphite samples, IG-110 and PCEA, were tested for infiltration with LiF-NaF-KF (FLiNaK) at 750°C, 5 bar for 12 h, and, after the intrusion experiment, the graphite was analyzed by neutron imaging. The graphite and Li from FLiNaK showed great contrast in the neutron attenuation coefficient. Thus, the salt behavior in the graphite structure has been visualized for the first time without damaging the sample. The 3D image of the graphite was reconstructed after a neutron computed tomography scan, and the average salt coverage distribution of the XY surface in different depths was obtained from the reconstructed 3D images.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

LABQ3: Bayesian method for quantification of mineral compositions and nano-scale elemental mapping of 3D synchrotron XCT data

Quantitative analysis of mineral compositions is essential in understanding geochemical, mineralogical and environmental processes. Fine-resolution 3D imaging is widely done using synchrotron X-ray computed tomography (XCT), but existing analyses are limited to visualization and segmentation. This paper presents a new method, Linear Attenuation Bayesian Quantitative 3D-mapper (LABQ3), based on the linearity of X-ray attenuation with respect to elemental concentrations. To address the random variability in attenuation measurements, LABQ3 employs Bayesian decision theory to minimize classification error, using reference attenuation distributions from scans of pure mineral standards. To demonstrate LABQ3 and test its performance, we studied precipitated carbonate samples. XCT scans were done at multiple energies using the transmission X-ray microscope (TXM) at beamline 32-ID-C of the Advanced Photon Source at Argonne National Laboratory. The reconstructed 3D images have a voxel size of 20 nm. Analyses revealed rich nano-scale compositional heterogeneity within individual particles. A mixture of calcium and cadmium produced an overall stoichiometric composition of (Ca 0.78 ,Cd 0.22 )CO 3 , with some voxels containing nearly pure CdCO 3 . The addition of zinc led to an overall stoichiometric composition of 33% Ca, 28% Cd, 39% Zn, with a nearly pure CaCO 3 core and compositional zonation through the rim. These compositional gradients are related to temporal sequences of carbonate mineral formation where Cd precipitated at the beginning in (Ca,Cd)CO 3 , while Cd and Zn precipitated at the end in (Ca, Cd,Zn)CO 3 . Results differ from bulk analyses using Inductively Coupled Plasma-Mass Spectrometry (ICP-MS), showing that LABQ3 provides particle-specific insights. LABQ3 distinguishes itself by quantifying chemical compositions along a continuum, making it different from XCT analyses based on segmentation. LABQ3 allows simultaneous acquisition of morphology and chemical composition in 3D, facilitating the interpretation of chemical gradients of trace elements, quantification of solid solution compositions, inferences about temporal sequences of mineral precipitation, and addressing other concerns about solid-phase chemistry.

58 GEOSCIENCES↗

Stereo Camera Simulation for Lunar Surface Photogrammetry

During the rocket-powered landing of a vehicle on a planetary body, the interaction between the rocket plume and the surface material beneath the vehicle plays a significant role in the descent dynamics and the safety of powered descent. However, in-situ data taken to investigate plume-surface interaction has been limited. The upcoming flight and lunar landing of the Intuitive Machines Nova-C will be equipped with the Stereo Cameras for Lunar Plume-Surface Studies (SCALPSS) science package, enabling the direct measurement of plume-induced surface cratering during powered descent. In this work, we present the engineering constraints, design iteration process, and simulation results that drove the design selection for the SCALPSS camera system. The chosen design will provide 3D-imaging coverage of 84 percent of the lunar surface directly under the landed Nova-C, in addition to some coverage of the neighboring surface. SCALPSS will provide a total 3D-imaging coverage area of approximately 13 square meters. With the anticipated Nova-C landing in October of 2021, SCALPSS will provide the first dedicated in-situ measurement of plume-induced surface cratering.

Ryan J. Thompson↗

3D seismic imaging of a fracture damage zone controlling reservoir compartmentalization at the Raft River EGS using multi-azimuth walkaway VSP

Accurate imaging of steeply dipping fracture zones in crystalline enhanced geothermal systems (EGS) is critical for constraining permeability architecture and guiding stimulation design. However, such structures remain poorly resolved by conventional surface seismic methods. We present a fully three-dimensional (3D) elastic-waveform inversion-migration workflow applied to multi-azimuth walkaway vertical seismic profiling (VSP) data acquired in a deviated borehole at the Raft River EGS. The workflow integrates first-arrival traveltime tomography, multi-scale elastic waveform inversion (EWI), and elastic least-squares reverse-time migration (ELSRTM) to recover high-resolution compressional-and shear-wave velocity models and to image structural discontinuities in the crystalline basement. The results reveal a laterally continuous low-velocity anomaly, with shear-wave velocity reductions of 25-30%, consistent with fractureinduced mechanical weakening. Two steeply dipping discontinuities bound a 50-80 m wide fracture damage zone. Independent constraints from microseismic clustering and geochemical compartmentalization corroborate the geometry and structural significance of this feature. Synthetic modeling further confirms that structures of this scale are resolvable (~30 m). These findings indicate that the Narrows structure is a distributed fracture damage zone rather than a discrete fault plane. By resolving fracture-zone geometry at the tens-of-meters scale using a single borehole, this workflow provides a practical and transferable approach for improving structural characterization, reducing uncertainty in permeability architecture, and supporting reservoir modeling and stimulation design in fractured crystalline EGS reservoirs.

58 GEOSCIENCES↗

Using dorsal surface for individual identification of dairy calves through 3D deep learning algorithms

Advances in machine learning techniques have allowed the development of computer vision systems (CVS) that can accurately predict several phenotypes of interest for livestock operations. In this context, 3D images taken from a top-down view are particularly useful for estimating body condition score, growth development, and body biometrics in cattle. Frequently, such CVS rely on identification (ID) systems, such as electronic tags, as a way to match animal ID and the predicted phenotype. However, the same 3D images used to predict body weight and other animal biometrics could be adopted for animal recognition as well. Such alternative would optimize CVS to recognize animal ID and monitor growth development simultaneously while leveraging the same hardware infrastructure. Furthermore, this strategy could be used to recognize animals with similar color patterns. Nonetheless, growing animals are continuously changing body shape, which could limit its use as an invariant feature for pattern recognition. Thus, the objectives of this study were: (1) to compare algorithms for different 3D object representations to identify individual animals; and (2) to evaluate how short-term changes in body shape due to animal growth affect the predictive performance of these algorithms. For objective 1, the algorithms were trained (n = 4,558) and tested (n = 1,139) using images from 38 Holstein calves. For objective 2, we designed three different experiments using images (n = 2,347) from five Holstein calves taken over six weeks during their growing period, always training and testing on different weeks. Each experiment evaluated how changing a different parameter of the image capturing procedure affected the predictive ability of the trained algorithms. In the first experiment, we varied the total number of images per animal in the training set; in the second experiment, we varied the number of weeks while keeping a fixed number of images in the training set; and in the third experiment, we skipped weeks between images in the training and test sets. The F 1 score for objective (1) was up to 0.804 when testing with the last frames of each video, and up to 0.959 when using random frames for testing. For objective (2), the F 1 score was up to 0.947 for the first experiment when using 130 images per animal; up to 0.979 for the second experiment when using all five weeks; and up to 0.917 when not skipping weeks between training and testing. In conclusion, these results show that deep learning algorithms can be used to identify individual animals through their dorsal area 3D surfaces, and, from our experiments using calves in their growing period, that they are robust enough to account for changes in body shape and size, making them a promising tool for animal recognition during growth.

3D neural networks↗

3D diffractive imaging of nanoparticle ensembles using an x-ray laser

Single particle imaging at x-ray free electron lasers (XFELs) has the potential to determine the structure and dynamics of single biomolecules at room temperature. Two major hurdles have prevented this potential from being reached, namely, the collection of sufficient high-quality diffraction patterns and robust computational purification to overcome structural heterogeneity. We report the breaking of both of these barriers using gold nanoparticle test samples, recording around 10 million diffraction patterns at the European XFEL and structurally and orientationally sorting the patterns to obtain better than 3-nm-resolution 3D reconstructions for each of four samples. With these new developments, integrating advancements in x-ray sources, fast-framing detectors, efficient sample delivery, and data analysis algorithms, we illuminate the path towards sub-nanometer biomolecular imaging. The methods developed here can also be extended to characterize ensembles that are inherently diverse to obtain their full structural landscape.

47 OTHER INSTRUMENTATION↗

recon3d

SAND2025-00533O recon3d is a software tool that provides automated 3D reconstruction and meshing capabilities. It processes labeled 3D image data from various sources, starting from image stacks, and calculates 3D feature distributions like size, shape, and location. The software also has tools for downscaling rectilinear grid data and creating tetrahedral meshes directly from image data. recon3d can be used by novice users via the command line with a properly formatted configuration file. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Emery, John↗

Dark-field X-ray microscopy with structured illumination for three-dimensional imaging

Dark-field X-ray microscopy is a lens-based technique that enables real-space imaging of heterogeneous micro- and meso-scale ordered materials. However, achieving accurate three-dimensional (3D) reconstruction often requires meticulous sample alignment or rastering, requiring complex rotational setups and extended acquisition times. To address these challenges, we introduce a structured illumination technique optimized for 3D imaging of ordered materials at sub-micrometer length scales. Our approach employs a coded aperture to spatially modulate the incident X-ray beam, enabling 3D structural reconstruction from images captured at various aperture positions. Unlike current 3D imaging approaches, which often rely on rotational or rastering methods, our technique uses scanning X-ray silhouettes of the coded aperture for depth resolution along the diffraction axis. This eliminates the need for sample rotation or rastering, resulting in a highly stable and efficient imaging modality. We validated the efficacy of this approach through experimental imaging of an isolated twin domain within a bulk single crystal of an iron pnictide using a dark-field X-ray microscope. This advancement aligns with the enhanced brightness upgrades of modern synchrotron radiation facilities, unlocking new possibilities for high-resolution imaging of ordered materials.

47 OTHER INSTRUMENTATION↗

ML-based Micro-CT SOFC Microstructure Models (from Kent 2026 Microstructural Augmentation paper)

Overview -------------------------- This repository contains datasets from the manuscript **"Enhanced Generalizability to Deep-Learning Quantification of 3D Microstructural Characteristics through Microstructurally Aware Augmentation of Scarce Data"** (*William F. Kent, Rochan Bajpai, Rachel C. Kurchin, William K. Epting, Harry W. Abernathy, Paul A. Salvador. Submitted 2026*). The methods are also described in the dissertation **Data Intensive Analysis of Solid Oxide Cell Microstructures** (*Doctoral dissertation, Carnegie Mellon University, 2025*). The datasets here are trained convolutional neural network (CNN) models for predicting key microstructural properties of solid oxide cell (SOC) electrodes from low-res, 2-channel 3D images, as well as some helpful code. The parameters for input images are provided in the paper. Sample data is provided in the file `Combined_anode_aug_dual_1k_examples` - that particular data was used to train `anode_all_aug.pth` and will work most accurately with that model. Please familiarize yourself with all caveats on accuracy and applicability, as detailed in the associated paper. Usage -------------------------- The basic usage is as follows, assuming `model_fn` is the path to the .pth file, and `X` is 2-channel input image(s) of the proper dimensions (either one image of shape `[2,12,24,24]`, or a batch of N input images of shape `[N,2,12,24,24]`): from CNN_inferencer import load_model_for_inference model = load_model_for_inference(model_fn) y_predicted = model(X) The model object automatically handles input scaling and output de-scaling based on the way the models were trained - in other words, pass in a 2-channel micro-CT image, and it will output microstructural property values in real units. ## Other model object attributes Note that model has useful attributes other than its forward pass model(X). * `model.output_descaler` - returns the output descaler object. Model does the de-scaling when generating inferences, but you may want to re-use this de-scaler on other values to e.g. compare predictions to ground truth from already-scaled training data. * `model.prop_names` - Gives the property names of the predicted y values, in order. Only exists if there's an output scaler as part of the model object, which there will be in the models provided here. ## Usage with sample data Here is a short script to use with the included sample data. from CNN_inferencer import display_predictions, load_model_for_inference, calculate_mape, parity_plot import h5py import numpy as np model_fn = 'anode_all_aug.pth' data_fn = 'Combined_anode_aug_dual_1k_examples.h5' N_samples = 200 figure_outdir = '.' model = load_model_for_inference(model_fn) with h5py.File(data_fn,'r') as f: XX = f['X'] #These are the 2-channel 3D images yy = f['y'] #These are the ground-truth microstructural properties, but they have been scaled for training - need to de-scale below N = XX.shape[0] #How many images total in the input data file #Run inferences on N_samples random samples from XX. #Run in a batch, much more efficient than one at a time. ii = np.random.choice(N,N_samples,replace=False) ii.sort() y_pred = model(XX[ii]) #Get the original/true (but normalized/scaled) values from the training dataset... #Because they were normalized, they are not in real units yet. So let's also de-scale them using model.output_scaler. y_true = model.output_scaler.transform(yy[ii]) #Let's display actual values for just 5 random ones for i in np.random.choice(N_samples,5,replace=False): display_predictions(y_true[i], y_pred[i], model.prop_names) #Make parity plots for each property (ground truth vs predicted values) #Also label each plot with the mean abs. percent error (MAPE) of the predicted values for i,key in enumerate(model.prop_names): mape = calculate_mape(y_true[:,i], y_pred[:,i]) parity_plot(y_true[:,i], y_pred[:,i], figure_outdir, key, extra_title=f' ({mape:.2f}% MAPE)')

3D microstructure↗

Development of green-colour-emitting pyrotechnics as a core for 3D temperature imaging sensors inside coal boilers

Efficiency in the control operation of the boilers for coal and coal with biomass can be further improved if the flue gas temperature distribution can be better characterized. This is very difficult in these harsh environmental systems, where spatially resolved measurements are nearly impossible with solid-state sensors. Here, in this work, we evaluate the development of pyrotechnic compounds that would serve as the basis for a novel optical mapping of the temperature inside coal boilers. For this purpose, various green-colour-emitting pyrotechnics using BaCl 2 · 2H 2 O and Ba(NO 3 ) 2 as the green light source were prepared, as this colour offers a distinct signal from the combustion-based background in the boiler. These pyrotechnics were characterized using thermogravimetric analysis (TGA) and X-ray diffraction (XRD) and tested using a flat-flame burner. Furthermore, the composition was varied to evaluate the effect of different metal fuels such as Sn, Co, and Mg, as well as various binders such as ethylcellulose, shellac, parlon, and PVC on green light emission. The emission intensity and the apparent ignition temperature were strongly dependent on the metal type, with Mg showing higher intensities. On the other hand, the effect of the binder showed that the ignition behaviour, emission intensity, and spectral purity were influenced by the nature and exothermicity of the binder. The addition of other potential green light-producing materials, such as boric acid, increased the intensity of emission by 17% for a BaCl 2 · 2H 2 O-based composition. This study identified prospective compositions with intense and bright green-colour emissions that have high spectral purities.

42 ENGINEERING↗

3D magnetic imaging using electron vortex beam microscopy

Abstract Electron vortex beams are free-electron waves that carry orbital angular momentum. There has been growing theoretical and experimental interest in the use of electron vortex beams as a tool for the investigation of magnetic materials. However, due to the complex wavefront of the propagating waves, a deeper understanding of the interaction of electron vortex beams and the magnetic sample is needed. Here we calculate the magnetic phase shift that an electron vortex beam obtains upon transmitting through a magnetic sample. We show that this magnetic phase shift is influenced by the out-of-plane magnetization, which is a unique characteristic of incident electron vortex beams and is proportional to their orbital angular momentum. Finally, we develop a phase retrieval methodology to retrieve the out-of-plane component of magnetization. Based on our theory, we discuss suitable experimental conditions that would enable this imaging capability for magnetic materials and further extend to non-magnetic chiral materials.

47 OTHER INSTRUMENTATION↗