Search NASA⌕ Search

SEARCH · Search NASA

Results for “60”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Endwall heat transfer in the junction region of a circular cylinder normal to a flat plate at 30 and 60 degrees from stagnation point of the cylinder

The objective of this experimental study was to investigate the influence of horseshoe vortex on the heat transfer on a flat plate near the base of a protruding cylinder. The partial shock reflection technique was used to produce the flow Mach number of 0.14 which simulated the mean inlet flow Mach number for the first stage vanes of the turbine after combustor. Fast response thin-film platinum heat gages were used to measure the heat transfer flux for radial distances of 0.75, 0.875, 1.0, 1.125 cylinder diameter. For a low Reynolds number of 20,000, r/D = 0.75, and angular location from the stagnation point = 60 deg, the maximum increase in the heat transfer rate with the cylinder was observed to be approximately 460 percent greater than without the cylinder. On the other hand, the increase in the heat flux for a high Reynolds number of 300,000 was approximately 70 percent greater. For the heat gages located along 30 deg and 60 deg angular locations from the stagnation point, the strong effect of the horseshoe vortex was observed in the junction region. The increase in the heat transfer rate depended on the type of boundary layer and on the boundary layer thickness ahead of the cylinder.

Nagamatsu, H. T.↗

60 micron luminosity evolution of rich clusters of galaxies

The average 60-micron flux has been determined for a collection of optically selected galaxy clusters at redshifts ranging from 0.30 to 0.92. The result, 26 mJy per cluster, represents the faintest flux determination known of using the IRAS data base. The flux from this set of clusters has been compared to the 60-micron flux from a sample of nearby galaxy clusters. It is found that the far-infrared luminosity evolution in cluster galaxies can be no more than a factor of 1.7 from z = 0.4 to the present epoch. This upper limit is close to the evolution predicted for simple aging of the stellar populations. Additional processes such as mergers, cannibalism, or enhanced rates of starbursts appear to occur at a low enough level that they have little influence on the far-infrared emission from clusters over this redshift range.

Kelly, Douglas M.↗

The Yerkes Observatory 60-channel far infrared camera for the Kuiper Airborne Observatory

The Yerkes Observatory Far Infrared Camera employs a two-dimensional, 60-detector array of (3)He-cooled silicon bolometers for broadband imaging in the spectral range of 40 to 240 microns. Four interchangeable filters have effective wavelengths of 60, 100, 160, and 200 microns. Three interchangeable lens sets give pixel sizes of 17, 27, and 45 in. Signals are processed through nitrogen-temperature JFET source-follower amplifiers, warm preamplifiers, and digital signal processors, and the system is controlled through a graphical user interface on a Macintosh computer. The camera has been used to image a wide variety of galactic and extragalactic far infrared sources.

Harper, D. AL, Jr.↗

Development of a Flexible Seal for a 60 psi Cryogenic Pressure Box

A cryogenic pressure box test facility has been designed and fabricated for use at NASA Langley Research Center (LaRC) to subject 5 ft x 6 ft curved panels to cryogenic temperatures and biaxial tensile loads. The cryogenic pressure box is capable of testing curved panels down to -423 F (20 K) with 54 psig maximum pressure. The key challenge in the design and fabrication of the pressure box was the development of a seal that could remain flexible at -423 F and contain 60 psi gaseous helium as the pressurization gas. A C-shaped seal was developed using a Gore-tex woven fabric. Mechanical testing of the fabric at room and elevated temperature, liquid nitrogen temperature, and liquid helium temperature demonstrated the strength and creep resistance of the material over the desired operating range. A small scale cryogenic pressure box was used to test prototype seals at cryogenic temperatures up to 60 psi. Preliminary tests indicated that excessive leakage was present through the seal. As a result, an aluminized mylar liner was placed inside the Gore-tex seal to reduce leakage through the seal. The final seal configuration resulted in minimal pressure loss during seal testing.

Glass, David E.↗

Low-Speed Investigation of the Effects of Frequency and Amplitude of Oscillation in Sideslip on the Lateral Stability Derivatives of a 60 deg Delta Wing, a 45 deg Sweptback Wing and an Unswept Wing

A low-speed investigation has been conducted in the Langley stability tunnel to study the effects of frequency and amplitude of sideslipping motion on the lateral stability derivatives of a 60 deg. delta wing, a 45 deg. sweptback wing, and an unswept wing. The investigation was made for values of the reduced-frequency parameter of 0.066 and 0.218 and for a range of amplitudes from +/- 2 to +/- 6 deg. The results of the investigation indicated that increasing the frequency of the oscillation generally produced an appreciable change in magnitude of the lateral oscillatory stability derivatives in the higher angle-of-attack range. This effect was greatest for the 60 deg. delta wing and smallest for the unswept wing and generally resulted in a more linear variation of these derivatives with angle of attack. For the relatively high frequency at which the amplitude was varied, there appeared to be little effect on the measured derivatives as a result of the change in amplitude of the oscillation.

Lichtenstein, Jacob H.↗

BOREAS TE-18, 60-m, Radiometrically Rectified Landsat TM Imagery

The BOREAS TE-18 team used a radiometric rectification process to produce standardized DN values for a series of Landsat TM images of the BOREAS SSA and NSA in order to compare images that were collected under different atmospheric conditions. The images for each study area were referenced to an image that had very clear atmospheric qualities. The reference image for the SSA was collected on 02-Sep-1994, while the reference image for the NSA was collected on 2 1 Jun-1995. The 23 rectified images cover the period of 07-Jul-1985 to 18-Sep-1994 in the SSA and 22-Jun-1984 to 09-Jun-1994 in the NSA. Each of the reference scenes had coincident atmospheric optical thickness measurements made by RSS-11. The radiometric rectification process is described in more detail by Hall et al. (1991). The original Landsat TM data were received from CCRS for use in the BOREAS project. Due to the nature of the radiometric rectification process and copyright issues, the full-resolution (30-m) images may not be publicly distributed. However, this spatially degraded 60-m resolution version of the images may be openly distributed and is available on the BOREAS CD-ROM series. After the radiometric rectification processing, the original data were degraded to a 60-m pixel size from the original 30-m pixel size by averaging the data over a 2- by 2-pixel window. The data are stored in binary image-format files. The data files are available on a CD-ROM (see document number 20010000884), or from the Oak Ridge National Laboratory (ORNL) Distributed Activity Archive Center (DAAC).

Hall, Forrest G.↗

Heat-Transfer Measurements at a Mach Number of 4.95 on Two 60 deg Swept Delta Wings with Blunt Leading Edges and Dihedral Angles of 0 deg and 45 deg

An experimental investigation was conducted to evaluate the heat-transfer characteristics of two 60 deg swept delta wings with cylindrical leading edges of 0.25-inch radii and dihedral angles of 0 deg and 45 deg. The tests were conducted at a Mach number of 4.95 and a stagnation temperature of 400 F. The The test-section unit Reynolds number was varied from 1.95 x 10(exp 6) to 12.24 x 10(exp 6) per foot. The results of the investigation indicated that, in a plane normal to the leading edge, the laminar-flow heat-transfer distribution was in good agreement with two-dimensional blunt-body theory. The stagnation-line heat-transfer level could be predicted from two-dimensional blunt-body theory provided the stagnation-line heat-transfer coefficient was assumed to vary as the cosine of the effective sweep. A comparison of the heating rates to the 0 deg dihedral wing (planform sweep of 60 deg) and the 45 deg dihedral wing (planform sweep of 69.3 deg) with equal panel sweep and panel area indicated that the stagnation-line heat-transfer coefficient for the 45 deg dihedral wing could be as much as 40 percent less than the stagnation-line heat-transfer coefficient for the 0 deg dihedral wing at both equal angles of attack and equal lifts. The laminar-flow heat-transfer rate to both wings outside the vicinity of the stagnation line was essentially equal.

Stainback, P. Calvin↗

Heat-Transfer Measurements on the Apexes of Two 60 deg Sweptback Delta Wings (Panel Semiapex Angle of 30 deg) Having 0 deg and 45 deg Dihedral at a Mach Number of 4.95

An experimental investigation was conducted to evaluate the heat-transfer rates at the apex of two 60 degree sweptback delta wings (panel semi-apex angle of 30 degrees) having cylindrical leading edges and 0 degrees and 45 degree positive dihedral. The models tested might correspond to the first several feet of a hypersonic reentry vehicle. The tests were conducted at a Mach number of 4.95 and a stagnation temperature of 400 F. nominal test-section unit Reynolds numbers varied from 2 x 10(exp 6) to 12 x 10(exp 6) per foot. The results of the investigation indicated that the laminar heat-transfer distributions (ratio of local to stagnation-line heating rate) about the models normal to the leading edges were in close agreement with two-dimensional blunt-body theory. The three-dimensional stagnation point heat-transfer rate on the 0 degree dihedral model was in excellent agreement with theory and the stagnation-line heat transfer on the straight portion of the leading edge of both models approached a constant level 12 percent above the theoretical stagnation-line level on an isolated swept infinite cylinder. When the heating rates on the 45 degree dihedral model (planform sweep of 69.3 degree) were compared with those on the 0 degree dihedral model (planform sweep of 60 degrees) at equal angles of attack and equal lifts greater than zero, the stagnation-line heating rates on the 45 degrees dihedral model were, in general, considerably lower as a result of the difference in effective sweeps of the leading edges. On the wing panels inboard from the stagnation lines, the differences in heating were very small. The stagnation-line heat-transfer variation with angle of attack, the shift in stagnation-line location, and the reduction in stagnation-line heat transfer resulting from the increase in effective sweep when positive dihedral is incorporated into a constant-panel 0 degree dihedral wing, all agreed with the results of a theoretical study made of highly swept delta wings with large positive dihedral.

Gunn, Charles R.↗

Characteristics of a 60-Inch Arc-Image Furnace and Application to the Study of Materials

An arc-image furnace consisting of two paraboloidal searchlight mirrors 60 inches (152 centimeters) in diameter and a modified electrode mechanism has been developed and has been used as an operational piece of laboratory equipment for the study of the elevated-temperature behavior of engineering materials. Using two types of 16-millimeter high-current anodes and operating in the atmosphere at current levels of 80 to 550 amperes, the arc-image furnace provides a heating-rate range from 100 to 1,000 Btu per square foot-sec (27 to 270 cal per centimeters squared-sec) with good reliability and reproducibility. Running times vary from 60 seconds at 550 amperes to 10 minute or longer at the lower current levels.

Peters, Roger W.↗

BIGEL analysis of gene expression in HL60 cells exposed to X rays or 60 Hz magnetic fields

We screened a panel of 1,920 randomly selected cDNAs to discover genes that are differentially expressed in HL60 cells exposed to 60 Hz magnetic fields (2 mT) or X rays (5 Gy) compared to unexposed cells. Identification of these clones was accomplished using our two-gel cDNA library screening method (BIGEL). Eighteen cDNAs differentially expressed in X-irradiated compared to control HL60 cells were recovered from a panel of 1,920 clones. Differential expression in experimental compared to control cells was confirmed independently by Northern blotting of paired total RNA samples hybridized to each of the 18 clone-specific cDNA probes. DNA sequencing revealed that 15 of the 18 cDNA clones produced matches with the database for genes related to cell growth, protein synthesis, energy metabolism, oxidative stress or apoptosis (including MYC, neuroleukin, copper zinc-dependent superoxide dismutase, TC4 RAS-like protein, peptide elongation factor 1alpha, BNIP3, GATA3, NF45, cytochrome c oxidase II and triosephosphate isomerase mRNAs). In contrast, BIGEL analysis of the same 1,920 cDNAs revealed no differences greater than 1.5-fold in expression levels in magnetic-field compared to sham-exposed cells. Magnetic-field-exposed and control samples were analyzed further for the presence of mRNA encoding X-ray-responsive genes by hybridization of the 18 specific cDNA probes to RNA from exposed and control HL60 cells. Our results suggest that differential gene expression is induced in approximately 1% of a random pool of cDNAs by ionizing radiation but not by 60 Hz magnetic fields under the present experimental conditions.

Non-NASA Center↗

The Australian National Airborne Field Experiment 2005: Soil Moisture Remote Sensing at 60 Meter Resolution and Up

Spatially-distributed soil moisture observations have applications spanning a wide range of spatial resolutions from the very local needs of individual farmers to the progressively larger areas of interest to weather forecasters, water resource managers, and global climate modelers. To date, the most promising approach for space-based remote sensing of soil moisture makes use of passive microwave emission radiometers at L-band frequencies (1-2 GHz). Several soil moisture-sensing satellites have been proposed in recent years, with the European Space Agency's Soil Moisture Ocean Salinity (SMOS) mission scheduled to be launched first in a couple years. While such a microwave-based approach has the advantage of essentially allweather operation, satellite size limits spatial resolution to 10's of km. Whether used at this native resolution or in conjunction with some type of downscaling technique to generate soil moisture estimates on a finer-scale grid, the effects of subpixel spatial variability play a critical role. The soil moisture variability is typically affected by factors such as vegetation, topography, surface roughness, and soil texture. Understanding and these factors is the key to achieving accurate soil moisture retrievals at any scale. Indeed, the ability to compensate for these factors ultimately limits the achievable spatial resolution and/or accuracy of the retrieval. Over the last 20 years, a series of airborne campaigns in the USA have supported the development of algorithms for spaceborne soil moisture retrieval. The most important observations involved imagery from passive microwave radiometers. The early campaigns proved that the retrieval worked for larger and larger footprints, up to satellite-scale footprints. These provided the solid basis for proposing the satellite missions. More recent campaigns have explored other aspects such as retrieval performance through greater amounts of vegetation. All of these campaigns featured extensive ground truth collection over a range of grid spacings, to provide a basis for examining the effects of subpixel variability. However, the native footprint size of the airborne L-band radiometers was always a few hundred meters. During the recently completed (November, 2005) National Airborne Field Experiment (NAFE) campaign in Australia, a compact L-band radiometer was deployed on a small aircraft. This new combination permitted routine observations at native resolutions as high as 60 meters, substantially finer than in previous airborne soil moisture campaigns, as well as satellite footprint areal coverage. The radiometer, the Polarimetric L-band Microwave Radiometer (PLMR) performed extremely well and operations included extensive calibration-related observations. Thus, along with the extensive fine-scale ground truth, the NAFE dataset includes all the ingredients for the first scaling studies involving very-high-native resolution soil moisture observations and the effects of vegetation, roughness, etc. A brief overview of the NAFE will be presented, then examples of the airborne observations with resolutions from 60 m to 1 km will be shown, and early results from scaling studies will be discussed.

Kim, E. J.↗

Electric propulsion using C.sub.60 molecules

Fullerene propellants, which are stable carbon cage structures composed of even numbers of carbon atoms in the range of about 32 to 200 atoms, particularly a combination of conveniently obtainable C.sub.60 and C.sub.70, may be carried in solid form in a spacecraft, sublimated to produce the appropriate molecular propellant such as C.sub.60 or C.sub.70, which may then be ionized by DC discharge or RF radiation to efficiently produce specific impulses in the range above 1000 lbf -s/lbm.

Leifer, Stephanie D.↗

WISE-2005: LBNP/Treadmill and Resistive Exercise Countermeasures Maintain Aerobic Capacity during a 60-d Bed Rest

We have previously documented that supine treadmill exercise within lower body negative pressure (LBNPex) performed 6 sessions (raised dot) wk(sup -1) during 15- and 30-day bed rests (BR) maintained upright aerobic capacity (VO2pk). In the present study, ure are evaluating whether aerobic capacity is maintained during a 60-d BR when the LBNPex frequency is reduced to 2-4 sessions (raised dot) wk(sup -1) and resistance exercise (REX) is added 2-3 sessions (raised dot) wk(sup -1). Eight healthy women (32 plus or minus 4 yrs; 56.4 plus or minus 3.6 kg; 164 plus or minus 8 cm; mean plus or minus SD) performed maximal-exertion, graded treadmill tests before and 3 days after a 60-d, 6 deg. head-down tilt BR. (Earliest day the medical monitors would permit a maximal exercise test post-BR). During BR, four subjects performed no exercise (CON), while four other subjects (EX) performed LBNPex and REX on separate days. The LBNPex countermeasure employed an intermittent (40-80% pre-BR VO2pk), 40-min protocol against an LBNP pressure (-49 plus or minus 3 mmHg) applied to provide a footward force equivalent to 1.0-1.2 body weight. REX consisted of maximal concentric and eccentric supine leg press and heel raise exercises using a gravity-independent flywheel ergometer. Comparisons were performed using paired (within-group) or non-paired (between-group) t-tests. Three days post-BR, VO2pk of the CON group was reduced significantly from pre-BR (Pre:37.2 plus or minus 1.2, Post: 29.4 plus or minus 2 ml (raised dot) kg(sup -1) (raised dot) min(sup -1), P less than 0.05), while the VO2pk of the EX group was not significantly reduced (Pre: 39.6 plus or minus 1.9, Post: 38.0 plus or minus 0.6 ml (raised dot) kg(sup -1) (raised dot) min(sup -1)). Peak heart rate, ventilation, rating of perceived exertion, and respiratory exchange ratio were not significantly different between the two groups pre- and post-BR. These preliminary results suggest that the combined LBNPex and REX countermeasures may be sufficient to maintain upright aerobic capacity after long-duration space flights.

Schneider, Suzanne M.↗

Effects of 30-, 60-, and 90-Day Bed Rest on Postural Control in Men and Women

INTRODUCTION Head-down-tilt bed rest (HDT) has been used as a safe gr ound-based analog to mimic and develop countermeasures for the physiological effects of spaceflight, including decrements in postural stability. The purpose of this investigation was to characterize the effects of 30-, 60-, and 90-day bed rest on postural control in men and women. METHODS Twenty-nine subjects (18M,11F) underwent 13 days of ambula tory acclimatization and were placed in 6? HDT for 30 (n=12), 60 (n=8), or 90 (n=9) days, followed by 14 days of ambulatory recovery. Computerized dynamic posturography (CDP) was used to assess changes in sensory and motor components of postural control, and recovery after HDT. Sensory Organization Tests (SOTs) objectively evaluate one?s ability to effectively use or suppress visual, vestibular, and proprioceptive information for postural control. Stability during the SOTs was assessed using peak-to-peak sway and convergence toward stability limits to derive an equilibrium score. Motor Control Tests (MCTs) evaluate one?s ability to recover from unexpected support surface perturbations, with performance determined by center-of-pressure path length. Whole-body kinematic data were collected to determine body-sway strategy used to maintain stability during each condition. Baselines were determined pre-HDT. Recovery was tracked post-HDT on days 0, 1, 2, and 4. RESULTS Immediately after HDT, subjects showed decreased performance on most SOTs, primarily on sway-referenced support conditions, typically returning to baseline levels within 4 days. MCT performance was not significantly affected. There were no significant gender or duration differences in performance. Kinematic data revealed a tendency to use ankle strategy to maintain an upright stance during most SOT conditions. Interestingly, six subjects (2M,4F) experienced orthostatic intolerance and were unable to complete day 0 testing. CONCLUSION HDT mimics some un loading mechanisms of spaceflight and elicits orthostatic issues present post-spaceflight (contributing to instability); however, it does not sufficiently address the vestibular dysfunction which occurs post-spaceflight.

Esteves, Julie↗

Charpy Impact Energy and Microindentation Hardness of 60-NITINOL

60-NITINOL (60 wt.% Ni 40 wt.% Ti) is being studied as a material for advanced aerospace components. The Charpy impact energy and microindentation hardness has been studied for this material, fabricated by vacuum induction skull melting (casting) and by hot isostatic pressing. Test specimens were prepared in various hardened and annealed heat treatment conditions. The average impact energy ranged from 0.33 to 0.49J for the hardened specimens while the annealed specimens had impact energies ranging from 0.89 to 1.18J. The average hardness values of the hardened specimens ranged from 590 to 676 HV while that of the annealed specimens ranged from 298 to 366 HV, suggesting an inverse relationship between impact energy and hardness. These results are expected to provide guidance in the selection of heat treatment processes for the design of mechanical components.

Stanford, Malcolm K.↗

Preliminary Investigation of Surface Treatments to Enhance the Wear Resistance of 60-Nitinol

The use of protective surface treatments on 60-Nitinol (60wt%Ni-40wt%Ti) was studied. Various nitriding techniques as well as a (Ti, Al)N coating were evaluated visually, microscopically, and by hardness and scratch testing. The chemical composition of the surface treatments was investigated by x-ray techniques. The results indicate that very hard (greater than 1,000 HK) and adherent surface layers can be produced on 60-Nitinol. Further work is needed to determine the tribological properties of these surface treatments in relevant operating environments.

Nitinol↗