Search NASA⌕ Search

SEARCH · Search NASA

Results for “ANGULAR ACCELERATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Characteristics of a Lunar Landing Configuration Having Various Multiple-Leg Landing-Gear Arrangements

An experimental investigation has been made of some lunar-landing characteristics of a 1/6-scale dynamic model of a landing module having multiple-leg landing-gear systems. Symmetric four-point and five-point systems and an asymmetric four-point system were investigated. The landing-gear legs were inverted tripod arrangements having a telescoping main strut which incorporated a yielding-metal strap for energy dissipation, hinged V-struts, and circular pads. The landing tests were made by launching a free model onto an impenetrable hard surface (concrete) and onto a powdered-pumice overlay of various depths. Landing motion and acceleration data were obtained for a range of touchdown speeds, touchdown speeds, touch attitudes, and landing-surface conditions. Symmetric four-point and five-point systems and an Maximum normal acceleration experienced at the module center of gravity during landings on hard surface or pumice was 2g (full-scale lunar value in terms of earth's gravity) over a wide range of touchdown conditions. Maximum angular acceleration experienced was 12-1/2 radians/sec(exp 2) and maximum longitudinal acceleration was 1-3/4 g. The module was very stable with all gear configurations during landings on hard surface (coefficient of friction, microns=0.4) at all conditions tested. Some overturn instability occurred during landings on powdered pumice (microns=0.7 to 1.0) depending upon flight path, pitch and yaw attitude, depth of pumice, surface topography, and landing-gear configuration. The effect of stability of roll attitude for the limited amount of roll-attitude landing data obtained was insignificant. Compared with the four-point system, the five-point system with equal maximum gear radius increased landing stability slightly and improved the static stability for subsequent lunar launch. A considerable increase in landing stability in the direction of motion was obtained with an asymmetric four-point gear having two pads offset to increase gear radius by 33 percent in the direction of horizontal flight.

Blanchard, Ulysse J.↗

Mass properties calibration of the NASA Langley low frequency vibration test apparatus

This report presents a description and calibration results of the modified NASA Langley Low Frequency Vibration Test Apparatus. The description includes both the suspension system and the data acquisition system. The test apparatus consists of a 2 inch thick, 21 inch diameter aluminum plate that is suspended from an advanced suspension system using a 40 foot long cable system. The test apparatus employed three orthogonally aligned pairs of Sundstrand QA-700 servo accelerometers that can measure accelerations as low as 1 micro-g. The calibration involved deriving the mass and moments of inertia of the test platform from measured input forces and measured acceleration responses. The derived mass and moments were compared to test platform mass properties obtained initially from measurements with a special mass properties instrument. Results of the calibration tests showed that using the product of the test apparatus mass and the measured accelerations, the disturbance force at the center of gravity (CG) can be determined within 4 percent on all three axes. Similarly the disturbance moments about the X, Y, and Z axes can be determined within 5 percent by using the product of the measured moments of inertia and the angular accelerations about the X, Y, and Z axes.

Javeed, Mehzad↗

Gyroscopic stimulation of the semicircular canals during sensory deprivation.

A static object revolving at a constant velocity is stationary with respect to that environment. When the object is rotated outside the plane of spin, a gyroscopic or cross-coupled acceleration is produced orthogonal to the two planes of rotation. In this situation, a man feels himself moving in a direction other than that which his visual or proprioceptive sensors perceive. The conflict in spatial orientation is the cross-coupled acceleration imposed on the semicircular canals. This perceptual conflict and the thresholds involved were studied by partial isolation of the physiological stimuli through sensory deprivation. Subjects weighted to neutral buoyancy were submerged in 94 F water in the dark. The subjects were then rotated while being revolved about a displaced axis. Thresholds for detection of angular acceleration were higher than those reported in the literature for detection of acceleration of a single plane. This discrepancy may be attributable to the length of time the stimuli are imposed to each of the canals and the cupular response periods.

Newsom, B. D.↗

Two-dimensional spatiotemporal coding of linear acceleration in vestibular nuclei neurons

Response properties of vertical (VC) and horizontal (HC) canal/otolith-convergent vestibular nuclei neurons were studied in decerebrate rats during stimulation with sinusoidal linear accelerations (0.2-1.4 Hz) along different directions in the head horizontal plane. A novel characteristic of the majority of tested neurons was the nonzero response often elicited during stimulation along the "null" direction (i.e., the direction perpendicular to the maximum sensitivity vector, Smax). The tuning ratio (Smin gain/Smax gain), a measure of the two-dimensional spatial sensitivity, depended on stimulus frequency. For most vestibular nuclei neurons, the tuning ratio was small at the lowest stimulus frequencies and progressively increased with frequency. Specifically, HC neurons were characterized by a flat Smax gain and an approximately 10-fold increase of Smin gain per frequency decade. Thus, these neurons encode linear acceleration when stimulated along their maximum sensitivity direction, and the rate of change of linear acceleration (jerk) when stimulated along their minimum sensitivity direction. While the Smax vectors were distributed throughout the horizontal plane, the Smin vectors were concentrated mainly ipsilaterally with respect to head acceleration and clustered around the naso-occipital head axis. The properties of VC neurons were distinctly different from those of HC cells. The majority of VC cells showed decreasing Smax gains and small, relatively flat, Smin gains as a function of frequency. The Smax vectors were distributed ipsilaterally relative to the induced (apparent) head tilt. In type I anterior or posterior VC neurons, Smax vectors were clustered around the projection of the respective ipsilateral canal plane onto the horizontal head plane. These distinct spatial and temporal properties of HC and VC neurons during linear acceleration are compatible with the spatiotemporal organization of the horizontal and the vertical/torsional ocular responses, respectively, elicited in the rat during linear translation in the horizontal head plane. In addition, the data suggest a spatially and temporally specific and selective otolith/canal convergence. We propose that the central otolith system is organized in canal coordinates such that there is a close alignment between the plane of angular acceleration (canal) sensitivity and the plane of linear acceleration (otolith) sensitivity in otolith/canal-convergent vestibular nuclei neurons.

NASA Discipline Neuroscience↗

A Novel Approach for Computing Rigid Body Motion Using Linear Accelerations

Here, a novel approach is presented for computing general rigid body motion based on a few known linear accelerations. This method utilizes linear acceleration data obtained from three distinct points on the body, all within a body-fixed reference frame. The only requirement is that the three chosen points must not be collinear. A system of differential-algebraic equations is derived, combining principles of rigid body kinematics with theory of the rotation group SO(3). These equations provide a framework for numerically computing various motion parameters, including angular velocity, angular acceleration, body orientation, velocity field, acceleration field, and displacement field. By numerically solving this system of equations, we can fully characterize rigid body motion in three-dimensional space. A numerical example is provided to demonstrate the practical implementation and efficacy of the proposed technique, illustrating its potential for accurate motion computation in various applications.

42 ENGINEERING↗

Interaction of semicircular canal stimulation with carotid baroreceptor reflex control of heart rate

The carotid-cardiac baroreflex contributes to the prediction of orthostatic tolerance; experimental attenuation of the reflex response leads to orthostatic hypotension in humans and animals. Anecdotal observations indicate that rotational head movements about the vertical axis of the body can also induce orthostatic bradycardia and hypotension through increased parasympathetic activity. We therefore measured the chronotropic response to carotid baroreceptor stimulation in 12 men during varying conditions of vestibulo-oculomotor stimulation to test the hypothesis that stimulation of the semicircular canals associated with head movements in the yaw plane inhibits cardioacceleration through a vagally mediated baroreflex. Carotid-cardiac baroreflex response was assessed by plotting R-R intervals (ms) at each of 8 neck pressure steps with their respective carotid distending pressures (mmHg). Calculated baroreflex gain (maximal slope of the stimulus-response relationship) was measured under 4 experimental conditions: 1) sinusoidal whole-body yaw rotation of the subject in the dark without visual fixation (combined vestibular-oculomotor stimulation); 2) yaw oscillation of the subject while tracking a small head-fixed light moving with the subject (vestibular stimulation without eye movements); 3) subject stationary while fixating on a small light oscillating in yaw at the same frequency, peak acceleration, and velocity as the chair (eye movements without vestibular stimulation); and 4) subject stationary in the dark (no eye or head motion). Head motion alone and with eye movement reduced baseline baroreflex responsiveness to the same stimulus by 30%. Inhibition of cardioacceleration during rotational head movements may have significant impact on functional performance in aerospace environments, particularly in high-performance aircraft pilots during high angular acceleration in aerial combat maneuvers or in astronauts upon return from spaceflight who already have attenuated baroreflex functions.

Review, Tutorial↗

The vestibulo-ocular reflex of the squirrel monkey during eccentric rotation and roll tilt

The vestibulo-ocular reflexes (VOR) are determined not only by angular acceleration, but also by the presence of gravity and linear acceleration. This phenomenon was studied by measuring three-dimensional nystagmic eye movements, with implanted search coils, in six male squirrel monkeys during eccentric rotation. Monkeys were rotated in the dark at a constant velocity of 200 degrees/s (centrally or 79 cm off axis) with the axis of rotation always aligned with gravity and the spinal axis of the upright monkeys. The monkey's orientation (facing-motion or back-to-motion) had a dramatic influence on the VOR. These experiments show that: (a) the axis of eye rotation always shifted toward alignment with gravito-inertial force; (b) the peak value of horizontal slow phase eye velocity was greater with the monkey facing-motion than with back-to-motion; and (c) the time constant of horizontal eye movement decay was smaller with the monkey facing-motion than with back-to-motion. All of these findings were statistically significant and consistent across monkeys. In another set of tests, the same monkeys were rapidly tilted about their naso-occipital (roll) axis. Tilted orientations of 45 degrees and 90 degrees were maintained for 1 min. Other than a compensatory angular VOR during the angular rotation, no consistent eye velocity response was observed during or following the tilt for any of the six monkeys. The absence of any eye movement response following tilt weighs against the possibility that translational linear VOR responses are due to simple high-pass filtering of the otolith signals. The VOR response during eccentric rotation was divided into the more familiar angular VOR and linear VOR components. The angular component is known to depend upon semicircular canal dynamics and central influences. The linear component of the response decays rapidly with a mean duration of only 6.6 s, while the axis of eye rotation rapidly aligns (< 10 s) with gravito-inertial force. These results are consistent with the hypothesis that the measurement of gravito-inertial force by the otolith organs is resolved into central estimates of linear acceleration and gravity, such that the central estimate of gravitational force minus the central estimate of linear acceleration approximately equals the otolith measurement of gravito-inertial force.

NASA Discipline Neuroscience↗

The Effects of Slots and Flaps on Lateral Control of a Low-wing Monoplane as Determined in Flight

This paper presents the results of flight tests made to determine the effect of slots and flaps on the lateral control of a low-wing monoplane. Maximum angular accelerations in roll and yaw produced by sudden application of the ailerons and maximum accelerations in yaw produced by sudden application of the rudder during gliding flight were recorded for the following wing arrangements: (a) no auxiliary device; (b) full-span slots; (c) plain flaps; (d) flaps and full-span slots; (e) wing-tip slots. Rolling- and yawing-moment coefficients were derived from the accelerations. The full span slots and the flaps each had about the same influence on the aileron rolling moments. At values of the lift coefficient obtainable with the plain wing, the effect of these devices was negligible. At the higher lift coefficients obtainable with these devices, the rolling-moment coefficients increased slightly but, despite this increase, the aileron effectiveness progressively decreased with increasing lift coefficient, owing to the corresponding reduction in air speed. In the range covered by the tests, the effectiveness of the controls was appreciably reduced by the wing-tip slots. The adverse yawing moment of the ailerons experienced at the large lift coefficients obtained with the flaps was appreciably less than at similar lift coefficients obtained with either full-span or wing-tip slots. The yawing moments produced by the rudder were only slightly affected by the use of the auxiliary devices. The airplane was found to be laterally unstable with all combinations tested. Because of the angular velocities acquired in the time taken to deflect the ailerons the rolling moments recorded in flight were only about two thirds the values that would have been obtained with the wing restrained as in wind-tunnel tests.

WING SLOTS↗

A study of human performance in a rotating environment

Consideration is given to the lack of sufficient data relative to the response of man to the attendant oculovestibular stimulations induced by multi-directional movement of an individual within the rotating environment to provide the required design criteria. This was done to determine the overall impact of artificial gravity simulations on potential design configurations and crew operational procedures. Gross locomotion and fine motor performance were evaluated. Results indicate that crew orientation, rotational rates, vehicle design configurations, and operational procedures may be used to reduce the severity of the adverse effects of the Coriolis and cross-coupled angular accelerations acting on masses moving within a rotating environment. Results further indicate that crew selection, motivation, and short-term exposures to the rotating environment may be important considerations for future crew indoctrination and training programs.

Green, J. A.↗