Search NASA⌕ Search

SEARCH · Search NASA

Results for “APD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Environmental Radiation Measurements on MIR Station: Internal Experiment - Program 1

Environmental radiation levels on the Russian space station Mir are being monitored under differing shielding conditions by a series of six area passive dosimeters (APDs) placed at individual locations inside the Core and Kvant 2 modules, and by an External Dosimeter Array (EDA) to be-deployed on the exterior surface of the Kvant 2 module. Each APD and the EDA contains CR-39 plastic nuclear track detectors (PNTDs) for measurement of LET spectra and TLDs for absorbed dose measurements. Two of the missions, NASA-2/Mir-21 and NASA-3/Mir-22 have been completed and the six APDs from each mission returned to Earth from Mir. This report covers progress to date on the analysis of TLDs and PNTDs from these two missions. For NASA-2/Mir-21, average mission absorbed dose rates varied from 271 to 407 micro-Gy/d at the APDS. For NASA-3/Mir-22, average mission absorbed dose rates varied from 265 to 421 micro-Gy/d.

Benton, E. V.↗

Temperature Control of Avalanche Photodiode Using Thermoelectric Cooler

Avalanche photodiodes (APDS) are quantum optical detectors that are used for visible and near infrared optical detection applications. Although APDs are compact, rugged, and have an internal gain mechanism that is suitable for low light intensity; their responsivity, and therefore their output, is strongly dependent on the device temperature. Thermoelectric coolers (TEC) offers a suitable solution to this problem. A TEC is a solid state cooling device, which can be controlled by changing its current. TECs are compact and rugged, and they can precisely control the temperature to within 0.1 C with more than a 150 C temperature gradient between its surfaces. In this Memorandum, a proportional integral (PI) temperature controller for APDs using a TEC is discussed. The controller is compact and can successfully cool the APD to almost 0 C in an ambient temperature environment of up to 27 C.

Refaat, Tamer F.↗

Capacity of Pulse-Position Modulation (PPM) on Gaussian and Webb Channels

This article computes the capacity of various idealized soft-decision channels modeling an optical channel using an avalanche photodiode detector (APD) and pulse-position modulation (PPM). The capacity of this optical channel depends in a complicated way on the physical parameters of the APD and the constraints imposed by the PPM orthogonal signaling set. This article attempts to identify and separate the effects of several fundamental parameters on the capacity of the APD-detected optical PPM channel. First, an overall signal-to-noise ratio (SNR) parameter is de ned such that the capacity as a function of a bit-normalized version of this SNR drops precipitously toward zero at quasi-brick-wall limits on bit SNR that are numerically the same as the well-understood brick-wall limits for the standard additive white Gaussian noise (AWGN) channel. A second parameter is used to quantify the effects on capacity of one unique facet of the optical PPM channel (as compared with the standard AWGN channel) that causes the noise variance to be higher in signal slots than in nonsignal slots. This nonuniform noise variance yields interesting capacity effects even when the channel model is AWGN. A third parameter is used to measure the effects on capacity of the difference between an AWGN model and a non-Gaussian model proposed by Webb (see reference in [2]) for approximating the statistics of the APD-detected optical channel. Finally, a fourth parameter is used to quantify the blending of a Webb model with a pure AWGN model to account for thermal noise. Numerical results show that the capacity of M-ary orthogonal signaling on the Webb channel exhibits the same brick-wall Shannon limit, (M ln 2)=(M 1), as on the AWGN channel ( 1:59 dB for large M). Results also compare the capacity obtained by hard- and soft-output channels and indicate that soft-output channels o er a 3-dB advantage.

Dolinar, S.↗

Development of Ultra-High Sensivity Silicon Carbide Detectors

A variety of silicon carbide (SiC) detectors have been developed to study the sensitivity of SiC ultraviolet (UV) detectors, including Schottky photodiodes, p-i-n photodiodes, avalanche photodiodes (APDs), and single photon-counting APDs. Due to the very wide bandgap and thus extremely low leakage current, Sic photo-detectors showed excellent sensitivity. The specific detectivity, D*, of SiC photodiodes are orders of magnitude higher than that of their competitors, such as Si photodiodes, and comparable to the D* of photomultiplier tubes (PMTs). To pursue the ultimate detection sensitivity, SiC APDs and single photon-counting avalanche diodes (SPADs) have also been fabricated. By operating the SiC APDs at a linear mode gain over 10(exp 6), SPADs in UV have been demonstrated. SiC UV detectors have great potential for use in solar blind UV detection and biosensing. Moreover, SiC detectors have excellent radiation hardness and high temperature tolerance which makes them ideal for extreme environment applications such as in space or on the surface of the Moon or Mars.

Yan, Feng↗

Smaller, Lower-Power Fast-Neutron Scintillation Detectors

Scintillation-based fast-neutron detectors that are smaller and less power-hungry than mainstream scintillation-based fast-neutron detectors are undergoing development. There are numerous applications for such detectors in monitoring fast-neutron fluxes from nuclear reactors, nuclear materials, and natural sources, both on Earth and in outer space. A particularly important terrestrial application for small, low-power, portable fast-neutron detectors lies in the requirement to scan for nuclear materials in cargo and baggage arriving at international transportation facilities. The present development of miniature, low-power scintillation-based fast-neutron detectors exploits recent advances in the fabrication of avalanche photodiodes (APDs). Basically, such a detector includes a plastic scintillator, typically between 300 and 400 m thick with very thin silver mirror coating on all its faces except the one bonded to an APD. All photons generated from scintillation are thus internally reflected and eventually directed to the APD. This design affords not only compactness but also tight optical coupling for utilization of a relatively large proportion of the scintillation light. The combination of this tight coupling and the avalanche-multiplication gain (typically between 750 and 1,000) of the APD is expected to have enough sensitivity to enable monitoring of a fast-neutron flux as small as 1,000 cm(exp -2)s(exp -1). Moreover, pulse-height analysis can be expected to provide information on the kinetic energies of incident neutrons. It has been estimated that a complete, fully developed fast-neutron detector of this type, would be characterized by linear dimensions of the order of 10 cm or less, a mass of no more than about 0.5 kg, and a power demand of no more than a few watts.

Patel, Jagdish↗

Novel Photon-Counting Detectors for Free-Space Communication

We present performance data for novel photon counting detectors for free space optical communication. NASA GSFC is testing the performance of three novel photon counting detectors 1) a 2x8 mercury cadmium telluride avalanche array made by DRS Inc. 2) a commercial 2880 silicon avalanche photodiode array and 3) a prototype resonant cavity silicon avalanche photodiode array. We will present and compare dark count, photon detection efficiency, wavelength response and communication performance data for these detectors. We discuss system wavelength trades and architectures for optimizing overall communication link sensitivity, data rate and cost performance. The HgCdTe APD array has photon detection efficiencies of greater than 50 were routinely demonstrated across 5 arrays, with one array reaching a maximum PDE of 70. High resolution pixel-surface spot scans were performed and the junction diameters of the diodes were measured. The junction diameter was decreased from 31 m to 25 m resulting in a 2x increase in e-APD gain from 470 on the 2010 array to 1100 on the array delivered to NASA GSFC. Mean single photon SNRs of over 12 were demonstrated at excess noise factors of 1.2-1.3.The commercial silicon APD array has a fast output with rise times of 300ps and pulse widths of 600ps. Received and filtered signals from the entire array are multiplexed onto this single fast output. The prototype resonant cavity silicon APD array is being developed for use at 1 micron wavelength.

Photons↗

Novel Photon-Counting Detectors for Free-Space Communication

We present performance data for novel photon-counting detectors for free space optical communication. NASA GSFC is testing the performance of two types of novel photon-counting detectors 1) a 2x8 mercury cadmium telluride (HgCdTe) avalanche array made by DRS Inc., and a 2) a commercial 2880-element silicon avalanche photodiode (APD) array. We present and compare dark count, photon-detection efficiency, wavelength response and communication performance data for these detectors. We successfully measured real-time communication performance using both the 2 detected-photon threshold and AND-gate coincidence methods. Use of these methods allows mitigation of dark count, after-pulsing and background noise effects. The HgCdTe APD array routinely demonstrated photon detection efficiencies of greater than 50% across 5 arrays, with one array reaching a maximum PDE of 70%. We performed high-resolution pixel-surface spot scans and measured the junction diameters of its diodes. We found that decreasing the junction diameter from 31 micrometers to 25 micrometers doubled the e- APD gain from 470 for an array produced in the year 2010 to a gain of 1100 on an array delivered to NASA GSFC recently. The mean single-photon SNR was over 12 and the excess noise factors measurements were 1.2-1.3. The commercial silicon APD array exhibited a fast output with rise times of 300 ps and pulse widths of 600 ps. On-chip individually filtered signals from the entire array were multiplexed onto a single fast output.

Photons↗

HgCdTe Avalanche Photodiode Detectors for Airborne and Spaceborne Lidar at Infrared Wavelengths

We report results from characterizing the HgCdTe avalanche photodiode (APD) sensorchip assemblies (SCA) developed for lidar at infrared wavelength using the high density vertically integrated photodiodes (HDVIP) technique. These devices demonstrated high quantum efficiency, typically greater than 90 between 0.8 micrometers and the cut-off wavelength, greater than 600 APD gain, near unity excess noise factor, 6-10 MHz electrical bandwidth and less than 0.5 fW/Hz(exp.1/2) noise equivalent power (NEP). The detectors provide linear analog output with a dynamic range of 2-3 orders of magnitude at a fixed APD gain without averaging, and over 5 orders of magnitude by adjusting the APD and preamplifier gain settings. They have been successfully used in airborne CO2 and CH4 integrated path differential absorption (IPDA) lidar as a precursor for space lidar applications.

Sun, Xiaoli↗

Monitor support on accelerated processing device

A technique for implementing synchronization monitors on an accelerated processing device (“APD”) is provided. Work on an APD includes workgroups that include one or more wavefronts. All wavefronts of a workgroup execute on a single compute unit. A monitor is a synchronization construct that allows workgroups to stall until a particular condition is met. Responsive to all wavefronts of a workgroup executing a wait instruction, the monitor coordinator records the workgroup in an “entry queue.” The workgroup begins saving its state to a general APD memory and, when such saving is complete, the monitor coordinator moves the workgroup to a “condition queue.” When the condition specified by the wait instruction is met, the monitor coordinator moves the workgroup to a “ready queue,” and, when sufficient resources are available on a compute unit, the APD schedules the ready workgroup for execution on a compute unit.

42 ENGINEERING↗

The Effect of Radiation Damage on the Charge Collection Efficiency of Silicon Avalanche Photodiodes

Understanding radiation effects on avalanche photodiodes (APDs) is important because they are used in several applications involving harsh radiation environments. APDs are used as photosensors in applications where speed and detection efficiency are critical. Proton irradiation experiments on a commercial off-the-shelf APD demonstrated that the irradiation flux and applied reverse bias have a strong influence on the severity of radiation effects. This is measured using the ion beam induced charge (IBIC) technique in which charge collection efficiency (CCE) describes the signal response from a device. CCE can degrade substantially due to radiation damage, but recent measurements show that certain combinations of irradiation flux and reverse bias can lead to increases in CCE up to 186% ± 24% for irradiations with 2 MeV protons at a fluence of 6.4 × 10 11 cm –2 . This defect-enhanced charge multiplication (DECM) only appeared when the reverse bias during irradiation ranged from 170 to 1830 V out of a maximum operating bias of 2000 V and the proton flux ranged from 9.8 × 10 7 to 3.4 × 10 9 cm –2 s –1 . Furthermore values outside of either range led to losses in CCE. It is expected that DECM should be encountered in other devices, especially those with sufficiently high electric fields to cause impact ionization.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Clinical Tumor Dimensions May Be Useful to Prevent Geographic Miss in Conventional Radiotherapy of Uterine Cervix Cancer-A Magnetic Resonance Imaging-Based Study

Purpose: To evaluate the risk of geographic miss associated with the classic four-field 'box' irradiation technique and to define the variables that predict this risk. Materials and Methods: The study population consisted of 80 patients with uterine cervix cancer seen between 2001 and 2006. Median age was 55 years (23-82 years), and 72 (90%) presented with squamous cell carcinoma. Most patients (68.7%) presented with locally advanced disease (IIb or more). Magnetic resonance imaging findings from before treatment were compared with findings from simulation of the conventional four-field 'box' technique done with rectal contrast. Study variables included tumor volume; involvement of vagina, parametrium, bladder, or rectum; posterior displacement of the anterior rectal wall; and tumor anteroposterior diameter (APD). Margins were considered adequate when the target volume (primary tumor extension, whole uterine body, and parametrium) was included within the field limits and were at least 1 cm in width. Results: Field limits were inadequate in 45 (56%) patients: 29 (36%) patients at the anterior and 28 (35%) at the posterior border of the lateral fields. Of these, 12 patients had both anterior and posterior miss, and this risk was observed in all stages of the disease (p = 0.076). Posterior displacement of the anterior rectal wall beyond S2-S3 was significantly correlated with the risk of geographic miss (p = 0.043). Larger tumors (APD 6 cm or above and volume above 50 cm{sup 3}) were also significantly correlated with this risk (p = 0.004 and p = 0.046, respectively). Conclusions: Posterior displacement of the anterior rectal wall, tumor APD, and volume can be used as guidance in evaluating the risk of geographic miss.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A high-performance β-solidifying TiAl alloy sheet: Multi-type lamellar microstructure and phase transformation

Highlights: • A high-performance β-solidifying TiAl alloy sheet is fabricated via hot rolling. • Fine multi-type β/γ and α{sub 2}/γ lamellar structures are formed during hot-rolling. • These lamellar structures are induced by the β → γ and α + γ → α{sub 2} + γ/γ{sub T} transformations. • The nano-scaled antiphase domain is induced by α → α{sub 2} disorder-order transformation. • The fine multi-type lamellar structures contribute to the strength enhancement. - Abstract: TiAl alloys are widely used in the aerospace industry and, hence, a thorough understanding of the corresponding microstructural evolution is crucial for providing insight into the fabrication of high-performance TiAl alloy sheets. In this study, a high-performance β-solidifying Ti-43Al-9V-0.2Y alloy sheet with multi-type lamellar structures was obtained via hot-rolling at an initial rolling temperature of 1260 °C. Owing to the temperature drop and reheat associated with multi-pass rolling, relatively fine irregular β/γ and regular α{sub 2}/γ lamellar microstructures (average size: ~25 μm) with nano-scaled antiphase domains (APDs) were generated by the β → γ and α + γ → α{sub 2} + γ/γ{sub T} phase transformations. These two lamellar structures have different formation mechanisms. The results of electron backscatter diffraction and transmission electron microscopy revealed that the nucleation and growth of (i) β/γ and (ii) α{sub 2}/γ lamellar structures are induced mainly by (i) stress and (ii) a combination of the stress and temperature drop during hot-rolling, respectively. Thin γ{sub T} precipitates from the α/α{sub 2} or γ phases. This precipitation is induced by the higher stress and lower temperature associated with the later stage (compared with those occurring in the initial stages) of hot-rolling. Moreover, compared with the corresponding as-forged alloy, the as-rolled TiAl alloy sheet exhibits better performance at both room and elevated temperatures. The improvement in the tensile properties is attributed to the duplex microstructure consisting of fine multi-type lamellar structures with nano-scaled APDs. The interface boundaries of β/γ, α{sub 2}/γ and APDs, which are effective in retarding dislocation motion, contribute mainly to strengthening of the alloy sheet.

36 MATERIALS SCIENCE↗

Particulate air pollution induces arrhythmia via oxidative stress and calcium calmodulin kinase II activation

Ambient particulate matter (PM) can increase the incidence of arrhythmia. However, the arrhythmogenic mechanism of PM is poorly understood. This study investigated the arrhythmogenic mechanism of PM. In Sprague–Dawley rats, QT interval was increased from 115.0 ± 14.0 to 142.1 ± 18.4 ms (p = 0.02) after endotracheal exposure of DEP (200 μg/ml for 30 min, n = 5). Ventricular premature contractions were more frequently observed after DEP exposure (100%) than baseline (20%, p = 0.04). These effects were prevented by pretreatment of N-acetylcysteine (NAC, 5 mmol/L, n = 3). In 12 Langendorff-perfused rat hearts, DEP infusion of 12.5 μg/ml for 20 min prolonged action potential duration (APD) at only left ventricular base increasing apicobasal repolarization gradients. Spontaneous early afterdepolarization (EAD) and ventricular tachycardia (VT) were observed in 8 (67%) and 6 (50%) hearts, respectively, versus no spontaneous triggered activity or VT in any hearts before DEP infusion. DEP-induced APD prolongation, EAD and VT were successfully prevented with NAC (5 mmol/L, n = 5), nifedipine (10 μmol/L, n = 5), and active Ca{sup 2+}/calmodulin-dependent protein kinase II (CaMKII) blockade, KN 93 (1 μmol/L, n = 5), but not by thapsigargin (200 nmol/L) plus ryanodine (10 μmol/L, n = 5) and inactive CaMKII blockade, KN 92 (1 μmol/L, n = 5). In neonatal rat cardiomyocytes, DEP provoked ROS generation in dose dependant manner. DEP (12.5 μg/ml) induced apoptosis, and this effect was prevented by NAC and KN 93. Thus, this study shows that in vivo and vitro exposure of PM induced APD prolongation, EAD and ventricular arrhythmia. These effects might be caused by oxidative stress and CaMKII activation. -- Highlights: ► The ambient PM consistently prolonged repolarization. ► The ambient PM induced triggered activity and ventricular arrhythmia. ► These effects were prevented by antioxidants, I{sub CaL} blockade and CaMKII blockade. ► The ambient PM can induce arrhythmia via oxidative stress and activation of CaMKII.

60 APPLIED LIFE SCIENCES↗

Evaluation of nefazodone-induced cardiotoxicity in human induced pluripotent stem cell-derived cardiomyocytes

The recent establishment of human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs), which express the major cardiac ion channels and recapitulate spontaneous mechanical and electrical activities, may provide a possible solution for the lack of in vitro human-based cardiotoxicity testing models. Cardiotoxicity induced by the antidepressant nefazodone was previously revealed to cause an acquired QT prolongation by hERG channel blockade. To elucidate the cellular mechanisms underlying the cardiotoxicity of nefazodone beyond hERG, its effects on cardiac action potentials (APs) and ion channels were investigated using hiPSC-CMs with whole-cell patch clamp techniques. In a proof of principle study, we examined the effects of cardioactive channel blockers on the electrophysiological profile of hiPSC-CMs in advance of the evaluation of nefazodone. Nefazodone dose-dependently prolonged the AP duration at 90% (APD{sub 90}) and 50% (APD{sub 50}) repolarization, reduced the maximum upstroke velocity (dV/dt{sub max}) and induced early after depolarizations. Voltage-clamp studies of hiPSC-CMs revealed that nefazodone inhibited various voltage-gated ion channel currents including I{sub Kr}, I{sub Ks}, I{sub Na}, and I{sub Ca}. Among them, I{sub Kr} and I{sub Na} showed relatively higher sensitivity to nefazodone, consistent with the changes in the AP parameters. In summary, hiPSC-CMs enabled an integrated approach to evaluate the complex interactions of nefazodone with cardiac ion channels. These results suggest that hiPSC-CMs can be an effective model for detecting drug-induced arrhythmogenicity beyond the current standard assay of heterologously expressed hERG K{sup +} channels. - Highlights: • Nefazodone prolonged APD and decreased upstroke velocity of APs in hiPSC-CMs. • Nefazodone inhibited cardiac ion channels, especially I{sub Kr} and I{sub Na}, in hiPSC-CMs. • Nefazodone-induced AP changes are mainly the result of I{sub Kr} and I{sub Na} inhibition. • hiPSC-CMs are sensitive model to validate nefazodone-induced cardiotoxicity. • hiPSC-CMs provide an integrated approach for evaluating mechanism of drug actions.

60 APPLIED LIFE SCIENCES↗

Inhibition of potassium currents is involved in antiarrhythmic effect of moderate ethanol on atrial fibrillation

Excessive consumption of alcohol is a well-established risk factor of atrial fibrillation (AF). However, the effects of moderate alcohol drinking remain to be elucidated. This study was designed to determine the effects of moderate ethanol ingestion on atrial fibrillation and the electrophysiological mechanisms. In acetylcholine-induced canine and mouse AF models, the moderate ethanol prevented the generation and persistence of AF through prolonging the latent period of AF and shortening the duration of AF. The action potential duration (APD) was remarkably prolonged under the concentration range of 12.5–50.0 mM ethanol in guinea pig atrial myocytes. Ultra-rapid delayed rectified potassium currents (I{sub Kv1.5}) were markedly inhibited by 12.5–50.0 mM ethanol in a concentration-dependent manner. Ethanol with 50.0 mM could inhibit rapid delayed rectifier potassium currents (I{sub hERG}). Ethanol under 6.25–50.0 mM did not affect on inward rectifier potassium currents (I{sub Kir2.1}). Collectively, the present study provided an evidence that moderate ethanol intake can prolong the APD of atrial myocytes by inhibition of I{sub Kv1.5} and I{sub hERG}, which contributed to preventing the development and duration of AF. - Highlights: • Moderate ethanol prevented the development of AF in animal models. • Moderate ethanol prolonged APD in guinea pig atrial myocytes. • Moderate ethanol inhibited Kv1.5 currents.

60 APPLIED LIFE SCIENCES↗

Synchronization of high speed framing camera and intense electron-beam accelerator

A new trigger program is proposed to realize the synchronization of high speed framing camera (HSFC) and intense electron-beam accelerator (IEBA). The trigger program which include light signal acquisition radiated from main switch of IEBA and signal processing circuit could provide a trigger signal with rise time of 17 ns and amplitude of about 5 V. First, the light signal was collected by an avalanche photodiode (APD) module, and the delay time between the output voltage of APD and load voltage of IEBA was tested, it was about 35 ns. Subsequently, the output voltage of APD was processed further by the signal processing circuit to obtain the trigger signal. At last, by combining the trigger program with an IEBA, the trigger program operated stably, and a delay time of 30 ns between the trigger signal of HSFC and output voltage of IEBA was obtained. Meanwhile, when surface flashover occurred at the high density polyethylene sample, the delay time between the trigger signal of HSFC and flashover current was up to 150 ns, which satisfied the need of synchronization of HSFC and IEBA. So the experiment results proved that the trigger program could compensate the time (called compensated time) of the trigger signal processing time and the inherent delay time of the HSFC.

43 PARTICLE ACCELERATORS↗

Analysis of edge density fluctuation measured by trial KSTAR beam emission spectroscopy system

A beam emission spectroscopy (BES) system based on direct imaging avalanche photodiode (APD) camera has been designed for Korea Superconducting Tokamak Advanced Research (KSTAR) and a trial system has been constructed and installed for evaluating feasibility of the design. The system contains two cameras, one is an APD camera for BES measurement and another is a fast visible camera for position calibration. Two pneumatically actuated mirrors were positioned at front and rear of lens optics. The front mirror can switch the measurement between edge and core region of plasma and the rear mirror can switch between the APD and the visible camera. All systems worked properly and the measured photon flux was reasonable as expected from the simulation. While the measurement data from the trial system were limited, it revealed some interesting characteristics of KSTAR plasma suggesting future research works with fully installed BES system. The analysis result and the development plan will be presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gigahertz-gated InGaAs/InP single-photon detector with detection efficiency exceeding 55% at 1550 nm

We report on a gated single-photon detector based on InGaAs/InP avalanche photodiodes (APDs) with a single-photon detection efficiency exceeding 55% at 1550 nm. Our detector is gated at 1 GHz and employs the self-differencing technique for gate transient suppression. It can operate nearly dead time free, except for the one clock cycle dead time intrinsic to self-differencing, and we demonstrate a count rate of 500 Mcps. We present a careful analysis of the optimal driving conditions of the APD measured with a dead time free detector characterization setup. It is found that a shortened gate width of 360 ps together with an increased driving signal amplitude and operation at higher temperatures leads to improved performance of the detector. We achieve an afterpulse probability of 7% at 50% detection efficiency with dead time free measurement and a record efficiency for InGaAs/InP APDs of 55% at an afterpulse probability of only 10.2% with a moderate dead time of 10 ns.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗