Search NASA⌕ Search

SEARCH · Search NASA

Results for “AUTO Program”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

97 records · Page 6

MO-PIS-Exhibit Hall-01: Imaging: CT Dose Optimization Technologies I

Partners in Solutions is an exciting new program in which AAPM partners with our vendors to present practical “hands-on” information about the equipment and software systems that we use in our clinics. The imaging topic this year is CT scanner dose optimization capabilities. Note that the sessions are being held in a special purpose room built on the Exhibit Hall Floor, to encourage further interaction with the vendors. Dose Optimization Capabilities of GE Computed Tomography Scanners Presentation Time: 11:15 – 11:45 AM GE Healthcare is dedicated to the delivery of high quality clinical images through the development of technologies, which optimize the application of ionizing radiation. In computed tomography, dose management solutions fall into four categories: employs projection data and statistical modeling to decrease noise in the reconstructed image - creating an opportunity for mA reduction in the acquisition of diagnostic images. Veo represents true Model Based Iterative Reconstruction (MBiR). Using high-level algorithms in tandem with advanced computing power, Veo enables lower pixel noise standard deviation and improved spatial resolution within a single image. Advanced Adaptive Image Filters allow for maintenance of spatial resolution while reducing image noise. Examples of adaptive image space filters include Neuro 3-D filters and Cardiac Noise Reduction Filters. AutomA adjusts mA along the z-axis and is the CT equivalent of auto exposure control in conventional x-ray systems. Dynamic Z-axis Tracking offers an additional opportunity for dose reduction in helical acquisitions while SmartTrack Z-axis Tracking serves to ensure beam, collimator and detector alignment during tube rotation. SmartmA provides angular mA modulation. ECG Helical Modulation reduces mA during the systolic phase of the heart cycle. SmartBeam optimization uses bowtie beam-shaping hardware and software to filter off-axis x-rays - minimizing dose and reducing x-ray scatter. The DICOM Radiation Dose Structured Report (RDSR) generates a dose report at the conclusion of every examination. Dose Check preemptively notifies CT operators when scan parameters exceed user-defined dose thresholds. DoseWatch is an information technology application providing vendor-agnostic dose tracking and analysis for CT (and all other diagnostic x-ray modalities) SnapShot Pulse improves coronary CTA dose management. VolumeShuttle uses two acquisitions to increase coverage, decrease dose, and conserve on contrast administration. Color-Coding for Kids applies the Broselow-Luten Pediatric System to facilitate pediatric emergency care and reduce medical errors. FeatherLight achieves dose optimization through pediatric procedure-based protocols. Adventure Series scanners provide a child-friendly imaging environment promoting patient cooperation with resultant reduction in retakes and patient motion. Philips CT Dose Optimization Tools and Advanced Reconstruction Presentation Time: 11:45 ‘ 12:15 PM The first part of the talk will cover “Dose Reduction and Dose Optimization Technologies” present in Philips CT Scanners. The main Technologies to be presented include: DoseRight and tube current modulation (DoseRight, Z-DOM, 3D-DOM, DoseRight Cardiac) Special acquisition modes Beam filtration and beam shapers Eclipse collimator and ClearRay collimator NanoPanel detector DoseRight will cover automatic tube current selection that automatically adjusts the dose for the individual patient. The presentation will explore the modulation techniques currently employed in Philips CT scanners and will include the algorithmic concepts as well as illustrative examples. Modulation and current selection technologies to be covered include the Automatic Current Selection component of DoseRight, ZDOM longitudinal dose modulation, 3D-DOM (combination of longitudinal and rotational dose modulation), Cardiac Dose right (an ECG based dose modulation scheme), and the DoseRight Index (DRI) IQ index. The special acquisition modes covers acquisition techniques such as prospective gating that is designed to reduce exposure to the patient through the Cardiac Step and Shoot scan mode. This mode can substitute the much higher dose retrospective scan modes for certain types of cardiac imaging. The beam filtration and beam shaper portion will discuss the variety of filtration and beam shaping configurations available on Philips scanners. This topic includes the x-ray beam characteristics, tube filtration as well as dose compensator characteristics. The Eclipse collimator, ClearRay collimator and the NanoPanel detector portion will discuss additional technologies specific to wide coverage CT that address some of the unique challenges encountered and techniques employed to optimize image quality and optimize dose utilization. The Eclipse collimator reduces extraneous exposure by actively blocking the radiation tails at either end of helical scans that do not contribute to the image generation. The ClearRay collimator and the NanoPanel detector optimize the quality of the signal that reaches the detectors by addressing the increased scattered radiation present in wide coverage and the NanoPanel detector adds superior electronic noise characteristics valuable when imaging at a low dose level. The second part of the talk will present “Advanced Reconstruction Technologies” currently available on Philips CT Scanners. The talk will cover filtered back projection (FBP), iDose4 and Iterative Model Reconstruction (IMR). Each reconstruction method will include a discussion of the algorithm as well as similarities and differences between the algorithms. Examples illustrating the merits of each algorithm will be presented, and techniques and metrics to characterize the performance of each type of algorithm will be presented. The Filtered Back projection portion will discuss and provide a brief summary of relevant standard image reconstruction techniques in common use, and discuss the common tradeoffs when using the FBP algorithm. The iDose4 portion will present the algorithms used for iDose4 as well the different levels. The meaning of different levels of iDose4 available will be presented and quantified. Guidelines for selection iDose4 parameters based on the imaging need will be explained. The different image quality goals available with iDose4 and specifically how iDose4 enables noise reduction, spatial resolution improvement or both will be explained. The approaches to leveraging the benefits of iDose4 such as improved spatial resolution, decreased noise, and artifact prevention will be described and quantified; and measurements and metrics behind the improvements will be presented. The image quality benefits in specific imaging situations as well as how to best combine the technology with other dose reduction strategies to ensure the best image quality at a given dose level will be presented. Insight into the IMR algorithm as well as contrast to the iDose4 techniques and performance characteristics will be discussed. Metrics and techniques for characterizing this class of algorithm and IQ performance will be presented. The image quality benefits and the dose reduction capabilities of IMR will be explored. Illustrative examples of the noise reduction, spatial resolution improvement, and low contrast detectability improvements of the reconstruction method will be presented: clinical cases and phantom measurements demonstrating the benefits of IMR in the areas of low dose imaging, spatial resolution and low contrast resolution are discussed and the technical details behind the measurements will be presented compared to both iDose4 and traditional filtered back projection (FBP)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automatic Generation of High-Performance Convolution Kernels on ARM CPUs for Deep Learning

In this work, we present FastConv, a template-based code auto-generation open source library that can automatically generate high-performance deep learning convolution kernels of arbitrary matrices/tensors shapes. FastConv is based on the Winograd algorithm, which is reportedly the highest performing algorithm for the time-consuming convolution layers of convolutional neural networks. ARM CPUs cover a wide range designs and specifications, from embedded devices to HPC-grade CPUs. The leads to the dilemma of how to consistently optimize Winograd-based convolution solvers for convolution layers of different shapes. FastConv addresses this problem by using templates to auto-generate multiple shapes of tuned kernels variants suitable for skinny tall matrices. As a performance portable library, FastConv transparently searches for the best combination of kernel shapes, cache tiles, scheduling of loop orders, packing strategies, access patterns, and online/offline computations. Auto-tuning is used to search the parameter configuration space for the best performance for a given target architecture and problem size. The experiments with layer-wise evaluation on the VGG--16 model confirms a 1.25x performance gains is got by tuning the Winograd library. Integrated comparison results shows 1.02x to 1.40x, 1.14x to 2.17x, and 1.22x and 2.48x speedup is achieved over NNPACK, Arm NN, and FeatherCNN on the Kunpeng 920 beside few cases. Furthermore, problem size performance portability experiments with various convolution shapes shows that FastConv achieves 1.2x to 1.7x speedup and 2x to 22x speedup over NNPACK and ARM NN inference engine using Winograd on Kunpeng 920 . CPU performance portability evaluation on the VGG--16 show an average speedup over NNPACK of 1.42x, 1.21x, 1.26x, 1.37x, 2.26x, and 11.02x is observed on Kunpeng 920, Snapdragon 835, 855, 888, Apple M1, and AWS Graviton2, respectively.

97 MATHEMATICS AND COMPUTING↗

Energy Saving Glass Lamination via Selective Radio Frequency Heating

Ceralink Inc. developed FastFuse™, a rapid, new, energy saving process for lamination of glass and composites using radio frequency (RF) heating technology. The Inventions and Innovations program supported the technical and commercial research and development needed to elevate the innovation from bench scale to a self-supporting technology with significant potential for growth. The attached report provides an overview of the technical and commerical progress achieved for FastFuse™ during the course of the project. FastFuse™ has the potential to revolutionize the laminate manufacturing industries by replacing energy intensive, multi-step processes with an energy efficient, single-step process that allows higher throughput. FastFuse™ transmits RF energy directly into the interlayer to generate heat, eliminating the need to directly heat glass layers and the surrounding enclosures, such as autoclaves or vacuum systems. FastFuse™ offers lower start-up and energy costs (up to 90% or more reduction in energy costs), and faster cycles times (less than 5 minutes). FastFuse™ is compatible with EVA, TPU, and PVB interlayers, and has been demonstrated for glass, plastics, and multi-material structures such as photovoltaics and transparent armor.

14 SOLAR ENERGY↗

Multi-Channel Auto-Dilution System for Remote Continuous Monitoring of High Soil-CO2 Fluxes

Geological sequestration has the potential capacity and longevity to significantly decrease the amount of anthropogenic CO2 introduced into the atmosphere by combustion of fossil fuels such as coal. Effective sequestration, however, requires the ability to verify the integrity of the reservoir and ensure that potential leakage rates are kept to a minimum. Moreover, understanding the pathways by which CO2 migrates to the surface is critical to assessing the risks and developing remediation approaches. Field experiments, such as those conducted at the Zero Emissions Research and Technology (ZERT) project test site in Bozeman, Montana, require a flexible CO2 monitoring system that can accurately and continuously measure soil-surface CO2 fluxes for multiple sampling points at concentrations ranging from background levels to several tens of percent. To meet this need, PNNL is developing a multi-port battery-operated system capable of both spatial and temporal monitoring of CO2 at concentrations from ambient to at least 150,000 ppmv. This report describes the system components (sampling chambers, measurement and control system, and power supply) and the results of a field test at the ZERT site during the late summer and fall of 2008. While the system performed well overall during the field test, several improvements to the system are suggested for implementation in FY2009.

01 COAL, LIGNITE, AND PEAT↗

Using AI to Reproduce Neutrino Cross Section Analysis - Prototyping the Neutrino Discovery Platform

The Neutrino Discovery Platform (NDP) aims to accelerate DUNE-era science by making the neutrino program's existing datasets analyzable through fast, reproducible, and auditable workflows. We report a working version of two of its layers, data curation and agentic orchestration, built and tested end to end on MINERvA open data. The guiding lesson throughout is that a cross section is a measurement, and not just a plotted shape, only if it carries a defensible systematic-uncertainty budget, a trustworthy unfolding, and a reproducible record. Using a single medium-energy playlist pair from the MINERvA open-data release (about $2.05\times10^{17}$ protons on target of data), we first reproduced the shapes of two published charged-current inclusive $\nu_\mu$ measurements through a complete extraction ladder: selection, background subtraction, D'Agostini unfolding, efficiency correction, and flux normalization. These shape-level reproductions ran and tracked the published results, but they lacked the systematic-uncertainty machinery that defines a MINERvA cross section. To supply it, we vendored and built the MINERvA Analysis Toolkit and developed a many-universe systematic-uncertainty tool that produces a portable covariance artifact, a parallel event-loop runner, and a per-run auditability harness. Validated against a published covariance release, the toolchain reproduces the released statistical, flux, and muon-energy-scale terms and shows that they account for roughly 63\% of the total variance, with the remainder unreleased. Using this same infrastructure, we then performed a measurement of our own design, the hadronic recoil-energy distribution of low-energy ($E_\nu<2.5$~GeV) charged-current inclusive events, and found data/simulation shape agreement of $\chi^2/\mathrm{ndf}=1.26$. Together these results show that the platform supports original physics and not only reproductions.

Breaux, Auto [Tulane U. (main)]↗

Toward the Neutrino Discovery Platform: An Auditable, Uncertainty-Bearing Toolchain for MINERvA Open-Data Cross-Section Analysis

The Neutrino Discovery Platform (NDP) aims to accelerate DUNE-era science by making the neutrino program's existing datasets analyzable through fast, reproducible, and auditable workflows. We report a working version of two of its layers, data curation and agentic orchestration, built and tested end to end on MINERvA open data. The guiding lesson throughout is that a cross section is a measurement, and not just a plotted shape, only if it carries a defensible systematic-uncertainty budget, a trustworthy unfolding, and a reproducible record. Using a single medium-energy playlist pair from the MINERvA open-data release (about $2.05\times10^{17}$ protons on target of data), we first reproduced the shapes of two published charged-current inclusive $\nu_\mu$ measurements through a complete extraction ladder: selection, background subtraction, D'Agostini unfolding, efficiency correction, and flux normalization. These shape-level reproductions ran and tracked the published results, but they lacked the systematic-uncertainty machinery that defines a MINERvA cross section. To supply it, we vendored and built the MINERvA Analysis Toolkit and developed a many-universe systematic-uncertainty tool that produces a portable covariance artifact, a parallel event-loop runner, and a per-run auditability harness. Validated against a published covariance release, the toolchain reproduces the released statistical, flux, and muon-energy-scale terms and shows that they account for roughly 63\% of the total variance, with the remainder unreleased. Using this same infrastructure, we then performed a measurement of our own design, the hadronic recoil-energy distribution of low-energy ($E_\nu<2.5$~GeV) charged-current inclusive events, and found data/simulation shape agreement of $\chi^2/\mathrm{ndf}=1.26$. Together these results show that the platform supports original physics and not only reproductions.

Breaux, Auto [Tulane U. (main)]↗

Ultra Efficient Light Duty Powertrain with Gasoline Low Temperature Combustion (Final Report)

This document details the work completed during Project DE-EE0006839 ‘Ultra Efficient Light Duty Powertrain with Gasoline Low Temperature Combustion’. All tasks from the project’s Statement of Project Objectives are discussed. Final demonstration data is also presented and discussed. Further project details can be found in the Quarterly Technicial Reports that were submitted during the course of the project and are stored on the EERE Project Management Center Website. The goal of this project was to develop, implement and demonstrate a low temperature combustion approach called Gasoline Direct Injection Compression Ignition (GDCI) that provides high thermal efficiency with low NOx and PM emissions. The project target was to demonstrate a 35% fuel economy improvement over the baseline vehicle while meeting Tier 3 emissions levels. At the start of this project, GDCI was a moderately mature combustion technology, due in large part to advances made during a Delphi Technologies program funded through an earlier Department of Energy Advanced Technology Powertrains (ATP) opportunity; under that earlier contract, DE-EE0003258, Delphi Technologies assembled a team with complementary industrial and academic experience, and led this team to advance the technology from the original fundamental work to the state of art embodied by a first-generation (Gen 1) multi-cylinder GDCI engine. Key activities during that project centered on engine and combustion chamber design, and development of fuel injection equipment, valvetrain and advanced controls. Performance results with the Gen 1 engine in a development vehicle demonstrated that GDCI had the capability to operate using Low Temperature Combustion (LTC) over a broad speed-load range. Based on benchmarking work, efficiency for the Gen 1 GDCI engine compared favorably overall to production light-duty diesel engines. The second DOE funded project, DE-EE0006839, focused on a number of technical risks and issues that were left to be resolved for GDCI to become a production-viable technology. These risks were:GDCI combustion system refinement to achieve near-ideal air/fuel mixture preparation for high efficiency and low HC and CO emissions; Transient control development for low temperature combustion with high EGR levels during real-world transient driving maneuvers and over a broader range of ambient conditions; Aftertreatment system design that is effective in dealing with the low-temperature challenges of a highly efficient engine. The project was executed in two phases. Phase 1 leveraged the development vehicle from the Advanced Technologies Powertrain 1 (ATP1) project, DE-EE0003258. That vehicle was used as an initial test bed in the development of a high performance low temperature exhaust aftertreatment system. The vehicle was also used to develop calibration refinements for improved exhaust emissions and fuel efficiency. Samples of a new GDCI development level engine, called Gen2 GDCI (and developed outside of the first DOE funded project), were also used during Phase 1 to develop refined controller hardware and control algorithms, as well as improved sensors and actuators. The Gen2 engine was then retrofitted into the development vehicle from the ATP1 project and used for controls refinement and calibration of GDCI to achieve improved cold start, drivability and robustness to real world environments and fuel variations. During Phase 2 of the project, Gen3 versions of the GDCI engine were designed and built specifically for this project based on experience from the earlier engines. These engines were designed to be production-like in construction and, when combined with refined control systems and project specific low temperature exhaust aftertreatment, were intended to support the goal of meeting Tier 3 emissions levels at a vehicle level. Though great progress had been made advancing the GDCI combustion process, and despite extensive presentations of our work on the technology at various conferences and in direct meetings with automotive companies, none of the US domestic automotive OEMs had shown an interest in adopting this combustion process as part of their technology planning as the project approached the Go/No-Go point at the end of Budget Period 3. As a result of this low-level of interest both the US Department of Energy and Delphi Technologies received in this technology from domestic auto manufactures, Delphi Technologies elected a ‘No-Go’ status for the gate between Budget Period 3 and Budget Period 4 which terminated the project without spending any Budget Period 4 funds. The project team concluded that the dynamometer mapping of the most recent level of hardware, combined with the vehicle level simulation by Argonne National Laboratory, was sufficient to document the capabilities and potential of the combustion process without spending the time and money to do the controls development and full calibration necessary for a demonstration vehicle.

33 ADVANCED PROPULSION SYSTEMS↗