AtomiStructure and Composition of Pt3Co Nanocatalysts in Fuel Cells: An Aberration-Corrected STEM HAADF Study
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Fuel cells, particularly proton exchange membrane fuel cells (PEMFCs), are promising energy conversion devices for the future. At the heart of these PEMFCs, Pt nanoparticles are currently used as the catalyst to dissociate H2 at the anode and O2 at the cathode. However, as Pt is extremely expensive, Pt3Co nanoparticles are being investigated as a way to reduce cost, as well as increase the overall effectiveness of the fuel cell.
A novel heating technology composed of a disposable MEMS-based (microelectromechanical systems) device has recently been developed and shown to provide unique in-situ heating capabilities in electron microscopes [1]. Protochips, Inc. (Raleigh, NC) provides the AduroTM heater technology, composed of a disposable MEMS device that serves both as the heating element and the specimen support grid, a TEM holder with electrical feed-throughs, and an external current source. This system has been shown to provide near instantaneous (106 C/s) heating and cooling, and is stable to the limit of the microscope's specimen stage so full sub- ngstr m image resolution in highangle annular dark-field imaging mode can be achieved on our JEOL 2200FS scanning transmission electron microscope (STEM/TEM) instrument, fitted with a hexapole corrector on the probe-forming lenses (CEOS GmbH, Heidelberg, Ger.). This heating technology is being extended to function in a closed cell system that allows heating in a gaseous environment for in-situ elevated temperature reaction studies. The design concepts and early results of testing of the environmental cell (E-cell) performance are detailed here.
In improved method of designing solid unstable resonator of laser diode, shapes of mirrors calculated to yield specified mode. Ray tracing used to compute shape of initially unspecified end mirror, given shape of initially specified end mirror and specified output mode. No need to accept aberrations or suboptimal circular shapes, to make iterative design computations in effort to converge on desired mode, or to assume paraxiality of rays: Angles between rays and optical axis large, cross sections of surfaces noncircular, and computed shape of end mirror exact. End mirror corrects for all aberrations.
Two approaches to reducing optical aberrations of concave grating spectrographs have been used, holographically controlling the groove curvature and spacing and reshaping the optical substrate while ruling the grooves conventionally. The latter approach, slightly deforming an ellipsoidal grating blank, can lead to diffraction-limited performance at a single FUV wavelength. When such a grating is used in a slitted Rowland circle spectrograph, the result is an extremely efficient spectrograph with spectral resolving power of about 30,000 and low astigmatism. Optical fabrication technology has advanced to the point where these exotic surface gratings are becoming practical.
The successful correction of third-order and, more recently, fifth-order aberrations has enormously enhanced the capabilities of the scanning transmission electron microscope (STEM), by not only achieving record resolution, but also allowing near 100% efficiency for electron energy loss spectroscopy, and higher currents for two-dimensional spectrum imaging. These advances have meant that the intrinsic advantages of the STEM, incoherent imaging and simultaneous collection of multiple complementary images can now give new insights into many areas of materials physics. Here, we review a number of examples, mostly from the field of complex oxides, and look towards new directions for the future.
We demonstrate that a transmission electron microscope fitted with two spherical-aberration correctors can be operated as an energy-filtered scanning confocal electron microscope. A method for establishing this mode is described and initial results showing 3D chemical mapping with nanoscale sensitivity to height and thickness changes in a carbon film are presented. Importantly, uncorrected chromatic aberration does not limit the depth resolution of this technique and moreover performs an energy-filtering role, which is explained in terms of a combined depth and energy-loss response function.
Designing and simulating complex magnet systems needed for cooling channels in both neutrino factories and muon colliders requires innovative techniques to correct for both chromatic and spherical aberrations. Optimizing complex systems, such as helical magnets for example, is also difficult but essential. By using COSY INFINITY, a differential algebra based code, the transfer and aberration maps can be examined to discover what critical terms have the greatest influence on these aberrations.
Purpose: The purpose of this work is to assess the magnitude of speed of sound (SOS) aberrations in three-dimensional ultrasound (US) imaging systems in image guided radiotherapy. The discrepancy between the fixed SOS value of 1540 m/s assumed by US systems in human soft tissues and its actual nonhomogeneous distribution in patients produces small but systematic errors of up to a few millimeters in the positions of scanned structures. Methods: A correction, provided by a previously published density-based algorithm, was applied to a set of five prostate, five liver, and five breast cancer patients. The shifts of the centroids of target structures and the change in shape were evaluated. Results: After the correction the prostate cases showed shifts up to 3.6 mm toward the US probe, which may explain largely the reported positioning discrepancies in the literature on US systems versus other imaging modalities. Liver cases showed the largest changes in volume of the organ, up to almost 9%, and shifts of the centroids up to more than 6 mm either away or toward the US probe. Breast images showed systematic small shifts of the centroids toward the US probe with a maximum magnitude of 1.3 mm. Conclusions: The applied correction in prostate and liver cancer patients shows positioning errors of several mm due to SOS aberration; the errors are smaller in breast cancer cases, but possibly becoming more important when breast tissue thickness increases.
Two approaches to reducing the optical aberrations of concave diffraction gratings have been studied to obtain candidate grating designs for the Lyman/Far-Ultraviolet Spectroscopic Explorer mission. The first approach involves shaping the grating substrate while using straight and equally spaced grooves. The second approach involves using a gating substrate with a relatively simple figure and holographically controlling the groove curvature and spacing. Specific designs derived from both approaches are analyzed and compared.
A technique for a real-time beam abberation correction scheme for deep space uplink and downlink communications is presented.
The burgeoning field of atomic-level material control holds great promise for future breakthroughs in quantum and memristive device manufacture and fundamental studies of atomic-scale chemistry. Realization of atom-by-atom control of matter represents a complex and ongoing challenge. Here, we explore the feasibility of controllable motion of dopant Si atoms at the edges of graphene via the sub-atomically focused electron beam in a scanning transmission electron microscope. Furthermore, we demonstrate that the graphene edges can be cleaned of Si atoms and then subsequently replenished from nearby source material. It is also shown how Si edge atoms may be “pushed” from the edge of a small hole into the bulk of the graphene lattice and from the bulk of the lattice back to the edge. This is accomplished through sputtering of the edge of the graphene lattice to bury or uncover Si dopant atoms. Finally, we demonstrate e-beam mediated hole healing and incorporation of dopant atoms. These experiments form an initial step toward general atomic-scale material control.
Explore the source record for details and available documents.
Previous works experimentally demonstrated that the application of spatially-coded apertures to simple sector mass spectrographs can result in increased signal intensity while maintaining spectral resolution comparable to that of a conventional slit aperture.[Chen, E.X., et al.: J Am Soc Mass Spectr. 26, 1633 (2015)][Russell, Z.E., et al.: J Am Soc Mass Spectr. 26, 248 (2015)] This spatial coding technique was later applied to a double-focusing Mattauch-Herzog mass spectrograph, and shown to be generally compatible with the architecture.[Russell, Z.E., et al.: J Am Soc Mass Spectr. 27, 1 (2016)] However, the achieved signal gain was limited by the spatial size of the electric sector gap. In this work, we introduce a modified version of the Mattauch-Herzog mass spectrograph with a wide-gap electric sector that is enabled by a novel, segmented-electrode approach, and show via simulation that this modified architecture alone (without aperture coding) achieves a 1.8x improvement in mass resolving power compared to a conventional Mattauch-Herzog spectrograph of equivalent size. Further, simulation of an aperture-coded version of the instrument supports a predicted signal strength increase of 50x with minimal loss of aperture clarity on the sensor due to the increased open area of the high-order coded aperture which can be passed.
Explore the source record for details and available documents.
Explore the source record for details and available documents.