Search NASA⌕ Search

SEARCH · Search NASA

Results for “Absolute”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Absolute nuclear charge radius by Na-like spectral line separation in high-Z elements

Abstract We describe a novel technique to determine absolute nuclear radii of high- Z nuclides. Utilizing accurate theoretical atomic structure calculations together with precise measurements of extreme ultraviolet transitions in highly charged ions this method allows for precise determinations of absolute nuclear charge radii based upon the well-known nuclear radii of their neighboring elements. This method can work for elements without stable isotopes, and its accuracy may be competitive with current methods (electron scattering and muonic x-ray spectroscopy).

Hosier, A. (ORCID:0000000328366605)↗

First measurements of the absolute branching fraction of Λ c ( 2625 ) + → Λ c + π + π − and upper limit on Λ c ( 2595 ) + → Λ c + π + π −

The absolute branching fraction of the decay Λ c ( 2625 ) + → Λ c + π + π − is measured for the first time to be ( 50.2 ± 5.7 stat ± 3.5 syst ) % with 368.48 pb − 1 of e + e − collision data collected by the BESIII detector at the center-of-mass energies of s = 4.918 and 4.950 GeV. Although the central value of the result is lower than the theoretical prediction of 67%, obtained from isospin symmetry, they are consistent taking the uncertainties into account. This is the first absolute branching fraction measurement for Λ c ( 2625 ) + since it was found. This measurement is necessary to obtain the coupling constants for the transitions between s -wave and p -wave charmed baryons in heavy hadron chiral perturbation theory. In addition, we search for the decay Λ c ( 2595 ) + → Λ c + π + π − . No significant signal is observed, and the upper limit on its branching fraction is determined to be 85.0% at the 90% confidence level. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Absolute Magnetometry with He3

We report development of a highly accurate (parts per billion) absolute magnetometer based on 3He NMR. Optical pumping polarizes the spins, long coherence times provide high sensitivity, and the 3He electron shell effectively isolates the nuclear spin providing accuracy limited only by corrections including materials, sample shape, and magnetization. Our magnetometer was used to confirm calibration, to 32 ppb, of the magnetic-field sensors used in recent measurements of the muon magnetic moment anomaly g-2, which differs from the standard model by 2.4 ppm. With independent determination of the magnetic moment of 3He, this work will lead the way to a new absolute magnetometry standard.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Absolute measurement of vacuum ultraviolet photon flux in an inductively coupled plasma using a Au thin film

A new method for absolute measurement of the vacuum ultraviolet (VUV) photon flux at the edge of a plasma is described. The light produced by the plasma was allowed to strike a negatively biased, gold-coated copper substrate remote from the plasma. The resulting photoelectron emission current was measured, and the absolute photon flux was then found from the known photoelectron yield of Au. The method was used to quantify the amount of VUV light produced by an Ar/He inductively coupled plasma (ICP). Strong emissions at 104.82 and 106.67 nm, corresponding to the 1s 2 and 1s 4 resonant states of Ar, were observed. The maximum, integrated VUV photon flux measured at the remote location was 3.2 × 10 13 photons/cm 2 s. This was estimated to correspond to a flux of 5 × 10 15 photons/cm 2 s at the edge of the ICP, in the range of reported values under similar conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of the absolute branching fraction of the inclusive decay $\Lambda _c^+ \rightarrow K_S^0X$: (BESIII Collaboration)

We report the first measurement of the absolute branching fraction of the inclusive decay Λ c + → K S 0 X . The analysis is performed using an e + e - collision data sample corresponding to an integrated luminosity of 567 pb - 1 taken at s = 4.6 GeV with the BESIII detector. Using eleven Cabibbo-favored Λ ¯ c - decay modes and the double-tag technique, this absolute branching fraction is measured to be B ( Λ c + → K S 0 X ) = ( 9.9 ± 0.6 ± 0.4 ) % , where the first uncertainty is statistical and the second systematic. The relative deviation between the branching fractions for the inclusive decay and the observed exclusive decays is ( 18.7 ± 8.3 ) % , which indicates that there may be some unobserved decay modes with a neutron or excited baryons in the final state.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Transportable absolute yields of underground nuclear explosions. Application to the North Korean nuclear tests

The method developed and presented here improves our nuclear explosion monitoring capability by providing a new independent and transportable method to determine the explosive yields of seismically recorded events associated with foreign weapons development. Here we report new independent absolute yield and depth of burial estimates of the North Korean nuclear tests which are commensurate with previously determined source parameters. The key advantage of this method over other methods which estimate absolute explosive yields is that this method does not require any a priori calibration, and can be immediately applied to any region of interest. This method uses the source information obtained from the spectral ratios of envelopes of measured seismic coda waves to invert for model-derived yield and depth of burial. The only requirements of this method are that the region of interest must contain several (> 3) seismic sources which have been well recorded (SNR > 2) by a set of shared stations. For regions with only a few events (~ 3) and/or extremely band-limited observations for which the depth of burial is unknown, an earthquake with a known magnitude may be required to obtain an accurate and robust yield estimate.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

The Absolute Color Calibration of the Dark Energy Survey: A Spectrophotometric Sample of DA White Dwarfs in the Southern Sky

The Dark Energy Survey (DES), which is nearing the completion of the analysis of its full data set, is an imaging survey of one-quarter of the Southern sky down to an apparent magnitude of $i\sim24.5$. The survey observations were conducted between 2013 and 2019 with a 3-square-degree wide-field CCD mosaic camera (the Dark Energy Camera, or DECam) on the Blanco 4-meter telescope at the Cerro Tololo Interamerican Observatory in the Chilean Andes. The primary scientific goal of the DES was to measure properties of Dark Energy. In order to achieve its science goals, the DES had tight requirements on both its relative and absolute photometric calibrations. In this poster, we describe the sample of pure-hydrogen-atmosphere (“DA”) white dwarfs which were instrumental in working to establish the requirement on the absolute color calibration -- i.e., the calibration across the filter bands -- of the DES.

79 ASTRONOMY AND ASTROPHYSICS↗

Absolute Efficiency Characterization of Neutron Detectors within Radioisotope Identification Devices [Slides]

Some Radioisotope Identification Devices (RIIDs) have a low efficiency neutron detector that can provide a neutron singles counting rate along with the primary gamma spectra that can be used to identify a radioisotope. When we know absolute efficiency, other characteristics of a radioisotope can be estimated such as mass or source strength when accompanied by the identity of the isotope and other observable variables. This study focuses on characterizing and comparing the absolute neutron efficiencies of some commonly used RIIDs: the ORTEC Detective X, ORTEC RADEAGLET-R, and FLIR IDentifinder 2.

Nuclear Criticality Safety Program (NCSP)↗

An absolute recoil-carbon polarimeter for polarized light-ions at the BNL Booster

We describe a recoil-carbon polarimeter for the BNL Booster synchrotron capable of measuring the transverse polarization of both the polarized proton beam and the polarized 3 He ion beam throughout the acceleration cycle. The instrument addresses a critical gap in the BNL polarized beam program: no independent polarization measurement currently exists in the injector chain between the 200 MeV Linac polarimeter and the AGS. The proposed new polarimeter will provide continuous, absolute polarization measurements at the Booster stage, supplying additional anchor points for the polarization transmission through the accelerator chain. The polarimeter 9 is based on elastic pC and 3 He C scattering from a thin internal carbon target, with detection of the recoil 12 C nucleus in a fixed six-station silicon detector ring. A single detector geometry provides continuous kinematic coverage from injection to extraction for both beam species without mechanical adjustment. For pC scattering, the available data and the Bonin parametrization provide a well-established basis for estimating the analyzing power and figure of merit over the Booster energy range; for 3 He C the sole experimental anchor is a measurement at 443 MeV, and the Booster polarimeter itself is identified as the instrument to map the analyzing power across the remainder of the acceleration ramp by a ramp-and-return calibration that anchors the absolute 3 He polarization scale to a few percent. Provision for future deuteron polarimetry is incorporated in the chamber design without modification to the existing geometry. With appropriate detector upgrades, the same recoil-carbon technique can be extended to deuteron beams, for which analyzing power data are already available, and, with future analyzing-power measurements, also to 6 Li and 7 Li beams, making the polarimeter a versatile instrument for the full range of light polarized ion species anticipated at BNL.

43 PARTICLE ACCELERATORS↗

Using an Absolute Cavity Pyrgeometer to Calibrate Pyrgeometers Outdoors with Respect to the International System of Units

Accurate measurement of the atmospheric longwave irradiance is important for renewable energy and atmospheric science applications. Pyrgeometers are deployed outdoors all over the world to measure the atmospheric longwave irradiance and presently are calibrated with traceability to the interim standards for atmospheric longwave radiation measurement, the standards are based on four pyrgeometers and their average irradiance is the World InfraRed Standard Group (WISG) which is developed and maintained by The Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center (PMOD/WRC). Since 2013 the InfraRed Integrating Sphere (IRIS) developed by PMOD/WRC and the Absolute Cavity Pyrgeometer (ACP) developed by the National Renewable Energy Laboratory (NREL) have been compared outdoors six times at different locations and the difference between the measured atmospheric longwave irradiance by ACP and IRIS was less than 2 W/m2 with traceability to the International System of Units (SI). During the six comparisons the irradiance measured by the interim WISG was 5 W/m2 lower than the irradiance measured by the average irradiance measured by the ACP and IRIS [1]. Based on this discrepancy, the World Meteorological Organization's Commission for Instruments and Methods of Observation (CIMO) recommended that the interim WISG should be adjusted to be traceable to SI units [2]. In anticipation of CIMO's expert team agreement on establishing the world reference using the average irradiance measured by ACP and IRIS in this article we describe a procedure to calibrate pyrgeometers with traceability to SI. One Absolute Cavity Pyrgeometer (ACP95F3) was used to calibrate four pyrgeometers traceable to SI units. Three Eppley PIRs and one Kipp&Zonen CG4 were originally calibrated with traceability to the interim WISG. Using the described procedure below, the responsivity of each pyrgeometer was then adjusted to match the irradiance measured by ACP. Outdoor data was collected during one clear sky nights monitored by the output thermopile voltage of ACP95F3. The irradiance measured by the PIRs was calculated using NREL equation and the CG4 using NREL equation and PMOD/WRC equation. Using the NREL equation, the calculated uncertainty (U_95) of the PIRs varied from 2.43 W/m2 to 2.67 W/m2, and for the CG4 using the NREL equation U_95 equals 1.97 W/m2, and using the PMOD equation U_95 equals 2.88 W/m2 with respect to SI.

International System of Units↗

Determination of the absolute contours of optical flats

Emersons procedure is used to determine true absolute contours of optical flats. Absolute contours of standard flats are determined and a comparison is then made between standard and unknown flats. Contour differences are determined by deviation of Fizeau fringe.

Primak, W.↗

Singular perturbation of absolute stability.

The influence of a small parameter at the higher derivatives in the differential equations describing nonlinear systems of the Lur'e-Postnikov class on absolute stability in the parameter space is investigated. The conditions leading to singular perturbations of absolute stability are examined.

Siljak, D. D.↗

A recalibration of the absolute magnitudes of supergiants.

Since luminosities of the supergiants are obtained most accurately by the group membership method, the study employed distance moduli of stellar groups that were determined from the magnitudes of the B-type main sequence stars using an extinction ratio of 3.0. For the supergiants, this ratio was taken to be a function of the spectral type following Schmidt-Kaler (1965) and Lee (1970). Supergiant data used in the construction of mean absolute magnitudes are discussed. In contrast to previous calibrations, no significant trend of visual absolute magnitude within a spectral subclass was found for the supergiants. Significant differences in some MK classes were observed between the results presented and the results of Blaauw and Schmidt-Kaler.

Stothers, R.↗

Singular perturbation of absolute stability.

It was previously shown (author, 1969) that the regions of absolute stability in the parameter space can be determined when the parameters appear on the right-hand side of the system equations, i.e., the regular case. Here, the effect on absolute stability of a small parameter attached to higher derivatives in the equations (the singular case) is studied. The Lur'e-Postnikov class of nonlinear systems is considered.

Siljak, D. D.↗

Experimental comparisons of the international pyrheliometric scale with the absolute radiation scale.

Solar irradiance measurements by instruments (Eppley Angstrom Pyrheliometers) reproducing the International Pyrheliometric Scale (IPS) have been compared with measurements made simultaneously by a number of JPL Active Cavity Radiometers (ACR) and the Practical Absolute Cavity Radiometer (PACRAD). The results of these tests demonstrate a systematic difference between the absolute radiation scale as defined by the ACR and PACRAD measurements and the IPS.

Willson, R. C.↗

Absolute intensity and polarization of rotational Raman scattering from N2, O2, and CO2

An experimental examination of the absolute intensity, polarization, and relative line intensities of rotational Raman scattering (RRS) from N2, O2, and CO2 is reported. The absolute scattering intensity for N2 is characterized by its differential cross section for backscattering of incident light at 647.1 nm, which is calculated from basic measured values. The ratio of the corresponding cross section for O2 to that for N2 is 2.50 plus or minus 5 percent. The intensity recent for N2, O2, and CO2 are shown to compare favorably to values calculated from recent measurements of the depolarization of Rayleigh scattering plus RRS. Measured depolarizations of various RRS lines agree to within a few percent with the theoretical value of 3/4. Detailed error analyses are presented for intensity and depolarization measurements. Finally, extensive RRS spectra at nominal gas temperatures of 23 C, 75 C, and 125 C are presented and shown to compare favorably to theoretical predictions.

Penney, C. M.↗