Toward measurements of absolute membrane potential in Bacillus subtilis using fluorescence lifetime
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
The Optical Penning (or Species-Selective Penning) Gauge technique is used for the measurement of the H2/D2/T2 fuel isotopic composition and He/D2 concentration in the neutralized particle exhaust of fusion devices. An Optical Penning detection system has already been used in JET during its first deuterium-tritium campaigns (DTE1) and has been chosen by ITER. Recent improvements to the sub-divertor diagnostic suite as well as the optical instrumentation, in preparation for the next DT campaign, have improved the optical throughput of the measurement and enabled 3He/D2 detection down to 0.1 %. For the first time, the 3He/4He isotopic ratio can be measured simultaneously with the H/D/T ratio. This technique is of particular interest for ion cyclotron resonance frequency (ICRF) heating scenarios.
No abstract prepared.
The design and performance of a new Compton-suppressed HPGe and charged-particle array, CLARION2-TRINITY, are described. The TRINITY charged-particle array is comprised of 64 Cerium-doped Gadolinium Aluminum Gallium Garnet (GAGG:Ce) crystals configured into five rings spanning 7–54 degrees, and two annular silicon detectors that can shadow or extend the angular coverage to backward angles with minimal $\gamma$-ray attenuation. GAGG:Ce is a non-hygroscopic, bright, and relatively fast scintillator with a light distribution well matched to SiPMs. Count rates up to 40 kHz per crystal are sustainable. Fundamental characteristics of GAGG:Ce are measured and presented, including light- and heavy-ion particle identification (PID) capability, pulse-height defects, radiation hardness, and emission spectra. The CLARION2 array consists of up to 16 Compton-suppressed HPGe Clover detectors (efficiency at 1 MeV) configured into four rings (eight HPGe crystal rings) using a non-Archimedean geometry that suppresses back-to-back coincident 511-keV gamma rays. The entire array is instrumented with 100- and 500-MHz (14 bit) waveform digitizers which enable triggerless operation, pulse-shape discrimination, fast timing, and pileup correction. Lastly, two examples of experimental data taken during the commissioning of the CLARION2-TRINITY system are given: a PID spectrum from 16 O + 18 O fusion-evaporation, and PID and Doppler-corrected -ray spectra from 48 Ti + 12 C Coulomb excitation.
GRETINA (Gamma-Ray Energy Tracking In-beam Nuclear Array), a state-of-the-art γ-ray tracking spectrometer, has been instrumental in advancing nuclear structure studies, particularly in experiments using fast beams of rare isotopes where the γ rays emitted in flight are subject to large Doppler shifts. This work presents an experimental determination of the γ-ray detection efficiency of GRETINA at energies up to 6 MeV. The high-energy γ rays originated from states that were populated in nucleon-removal reactions from a projectile beam at an intermediate beam energy of about 85 MeV/nucleon. Utilizing γ-γ coincidences, efficiency values were extracted in-beam and translated into a source efficiency at rest employing GEANT4 Monte Carlo simulations. A systematic discrepancy in the efficiency of the forward-positioned detectors was identified which is attributed to specific dead-time effects caused by high-energy light-particle events prevalent at forward angles, generating signals in the Ge crystals that saturate the preamplifier’s first stage. Furthermore, this study provides refined efficiency benchmarks for in-beam experiments, improving the accuracy of quantitative γ-ray spectroscopy analyses with GRETINA and GRETA (Gamma Ray Energy Tracking Array) in the future.
Pixelated High Rate Picosecond Photon Detectors (HRPPDs) by Incom Inc. are promising photosensors for use in Ring Imaging CHerenkov (RICH) detectors, where a high gain, sub-mm position resolution and sub-100ps timing resolution are required in a single photon mode. Quantum Efficiency (QE) has been measured for the first batch of EIC HRPPDs both by Incom and EIC research groups at Jefferson Lab and Brookhaven Lab, with peak values at ∼365 nm typically exceeding 30%. Furthermore, in this study, we present a first direct measurement of Photon Detection Efficiency being equal to (17.1 ± 0.1 [stat] ± 0.3 [sys])% at 398.6 nm, for a pixel near the center of HRPPD, in a photoelectron pulse counting mode using a picosecond diode laser. HRPPD QE at the same spot and at the same wavelength was evaluated to be (24.4 ± 0.1 [stat] ± 0.3 [sys])%, leading to a Collection Efficiency estimate of (70.3 ± 1.6)%, which is consistent with the expectations.
Iodine monochloride (ICl) is a gaseous off-product of molten salt reactors; monitoring this heteronuclear diatomic is of great interest for both environmental and safety purposes. In this paper we investigate the possibility of infrared monitoring of ICl by measuring the far-infrared absorption cross section of its fundamental band near 381 cm -1 . We have performed quantitative studies of the neat gas in a 20 cm cell at 25, 35, 50 and 70 oC at multiple pressures up to ~ 9 Torr and investigated the temperature and pressure dependence of the band’s infrared cross section. Quantitative measurements were problematic due to sample adhesion to the cell walls and windows as well as reactions/possible hydrolysis of ICl to form HCl gas. Effects were mitigated by measuring only the neat gas, using short measurement times and subtracting out the partial pressure of the HCl(g). The integrated band strength is shown to be temperature independent and was found to be equal to 9.1 x 10 -19 (cm 2 /molecule) cm-1. As expected, the temperature dependence of the band profile showed only a small effect over this limited temperature range. Furthermore, we have also investigated using the absorption data along with inverse least squares multivariate methods for the quantitative monitoring of ICl effluent concentrations under different scenarios using infrared (standoff) sensing and compare these results with traditional Beer’s Law (univariate) techniques.
Not provided.
We report second harmonic generation (SHG) electric field triplet interferometry performed using three mutually coherent ultrafast pulses in a common path with controllable relative phases, namely, the light fields of a sample signal (SI), a reference oscillator (RO), and a local oscillator (LO). The ROLO phase determined from the interference of the light fields produced by two quartz wafers is subtracted from the phase determined from the SIROLO interferogram to yield the signal phase, ϕ SI . The new method also calibrates the measured SHG intensity from a given sample internally by sending the fundamental light field reflected from the sample into one of the quartz wafers in the ROLO element. The approach avoids having to exchange the sample against a reference material with a known χ(2) value or known phase and accounts on-the-fly for situations where the reflected fundamental light field intensity changes with experimental conditions. The new method is successfully benchmarked against z-cut α-quartz, fused silica held at its point of zero charge, and hematite nanolayers in air, across three different interferometers. Furthermore, the approach should be applicable for other second-order nonlinear spectroscopies, such as vibrational or electronic sum-frequency generation.
We present a formally exact and simulation-free approach for the normalization of X-ray Thomson scattering (XRTS) spectra based on the f-sum rule of the imaginary-time correlation function (ITCF). Our method works for any degree of collectivity, over a broad range of temperatures, and is applicable even in nonequilibrium situations. In addition to giving us model-free access to electronic correlations, this new approach opens up the intriguing possibility to extract a plethora of physical properties from the ITCF based on XRTS experiments.
Explore the source record for details and available documents.
Laser absorption is one of the most important parameters governing laser–matter interactions. The laser energy absorption on nanowire array targets is measured for the first time in the relativistic regime at intensities of 10 19 W=cm 2 and compared to foil targets. The results show that the laser energy absorption of 0.7 ps frequency doubled (527 nm) pulses on Au nanowire targets varies widely with nanowire parameters, reaching laser energy absorption values up to 71% of the incident energy, significantly exceeding those of solid flat targets obtained in similar irradiation conditions. The analysis shows that the increase in absorption strongly correlates with larger effective target surface area over a broad range of nanowire parameters explored. These direct absorption measurements provide valuable data to benchmark simulations of the relativistic laser pulse interactions with nanostructures.
In this work, we report a technique of proton deflectometry that uses a grid and an in situ reference x-ray grid image for precise measurements of magnetic fields in high-energy-density plasmas. A D 3 He fusion implosion provides a bright point source of both protons and x-rays, which is split into beamlets by a grid. The protons undergo deflections as they propagate through the plasma region of interest, whereas the x-rays travel along straight lines. The x-ray image, therefore, provides a zero-deflection reference image. The line-integrated magnetic fields are inferred from the shifts of beamlets between the deflected (proton) and reference (x-ray) images. We developed a system for analysis of these data, including automatic algorithms to find beamlet locations and to calculate their deflections from the reference image. The technique is verified in an experiment performed at OMEGA to measure a nonuniform magnetic field in vacuum and then applied to observe the interaction of an expanding plasma plume with the magnetic field.
Atmospheric pressure plasma jets (APPJs) are operating in direct contact with dielectric substrates for many applications. Nonetheless, many studies have been focusing on free jets. In this letter, we report spatially resolved measurements of reactive species including neutral and ionic species in an He + 1% O 2 RF-driven APPJ by molecular beam mass spectrometry equipped with a dielectric sampling plate, enabling to detect species densities for APPJ operating remotely or in direct contact with a substrate. Here, the spatially resolved distribution of O, O 2 (a 1 Δ g ) and O 3 is dominated by convection and, remarkably, shows minimum differences between touching and non-touching conditions.