Search NASA⌕ Search

SEARCH · Search NASA

Results for “Absolute pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Multi-sensor fusion for robust autonomous flight in indoor and outdoor environments with a rotorcraft micro-aerial vehicle (MAV)

The subject matter described herein includes a modular and extensible approach to integrate noisy measurements from multiple heterogeneous sensors that yield either absolute or relative observations at different and varying time intervals, and to provide smooth and globally consistent estimates of position in real time for autonomous flight. We describe the development of the algorithms and software architecture for a new 1.9 kg MAV platform equipped with an IMU, laser scanner, stereo cameras, pressure altimeter, magnetometer, and a GPS receiver, in which the state estimation and control are performed onboard on an Intel NUC 3rd generation i3 processor. We illustrate the robustness of our framework in large-scale, indoor-outdoor autonomous aerial navigation experiments involving traversals of over 440 meters at average speeds of 1.5 m/s with winds around 10 mph while entering and exiting buildings.

42 ENGINEERING↗

Reexamining supercritical gas adsorption theories in nano-porous shales under geological conditions

Adsorption is an important phenomenon in surface chemistry, especially for nano-porous shales. In the shale gas-in-place, adsorbed gas could contribute up to 85%. However, adsorption is hard to quantitatively characterize due to different adsorption mechanisms, patterns, surfaces, and pore sizes. Moreover, key thermodynamic parameters, such as the enthalpy of adsorption, are challenging to determine due to uncertainties in adsorbed gas densities used in constructing absolute isotherms. In this paper, we revisit the Brunauer, Emmett, and Teller (BET) model, analytically simplify Ono-Kondo (OK) models for subsurface shales, and compare commonly used mono- and multilayer adsorption models (e.g., Langmuir, supercritical Dubinin-Radushkevich (SDR), supercritical BET (SBET), and simplified OK (OKs) models) with recently proposed pressure-dependent adsorption densities to develop a practical and reliable methodology that can be used in the supercritical state, typical for subsurface black shale conditions.Three independent data sets were used for nitrogen and methane adsorption isotherms at different temperatures. Furthermore, we demonstrate that adsorption predicted by the SDR model is comparable or lower than that predicted by the SBET model, but higher than the amounts predicted by Langmuir and OK models. The nitrogen BET method tends to underestimate the accessible SSA for methane. Measurement of isosteric heat of adsorption is suggested instead of the experimental fitting method, due to the significant difference between the calculated results by two commonly used methods. Experimental fitting and simulation methods are also briefly reviewed to guide future research on shale gas adsorption.

58 GEOSCIENCES↗

Aerosol emissions from water-lean solvents for post-combustion CO 2 capture

Advanced water-lean solvents (WLS) for post-combustion CO 2 capture have been gaining interest due to their ability to reduce the parasitic penalty from energy needed for solvent regeneration. Commercial implementation of these novel CO 2 capture technologies hinges on successful control of amine emissions. RTI conducted a parametric study of fundamental and operational variables influence on overall amine aerosol and vapor emissions from our water-lean solvent eCO 2 Sol™ using our 6-kW equivalent bench-scale gas absorption system. The parametric testing used a simulated flue gas with 15 % CO 2 , 2.3–4.2 % H 2 O, and 0–6 ppm sulfite (SO 3 ) to examine the impact of the presence of aerosols to the capture performance and amine emissions from the system. The SO 3 reacts with water in the flue gas to create H 2 SO 4 , which forms liquid aerosol droplets and provide nucleation sites for growth of aerosols. Scanning Mobility Particle Sizer and Aerodynamic Particle Sizer instruments monitored the aerosol particle size distribution. Parametric testing results suggested that the presence of the aerosols in the flue gas could increase the overall amine emissions by 10X compared to the baseline emissions from WLS’s vapor pressure. Principal component analysis (PCA) and projection to latent squares (PLS) developed models to predict the aerosol-based amine emissions from process data. The predictive PLS model had a correlation coefficient (Q 2 ) of 0.92 and could predict the aerosol-based emissions from the NAS process with ±15 % accuracy (average absolute deviation, AAD). The PLS regression model also identified key variables affecting aerosol-based emissions from WLS.

42 ENGINEERING↗

FY24 Report on Water NSTF Testing: Lower Tank Inlet Piping Configuration

The following report serves as a summary of the accomplishments and testing results by the Natural convection Shutdown heat removal Test Facility (NSTF) experimental program over the past 12-month period. A major activity included reconfiguration of the chimney piping geometry which altered the discharge position into the tank from the original 50% tank height to a new lower position at a 10.9% tank height. This modification increases the volume of available coolant thus extending long-term operating capacity, however also results in a decreased liquid driving head which has the potential to reduce the natural circulation efficiency and decrease overall performance. Examination of the tradeoffs for these two configurations is an area of interest for RCCS designers and drove planned test activities this year. Ten matrix tests were performed in FY24, totaling 195 hours of heated operations and 12.9 MWh of electrical heating throughout the year, with eight classified as Accepted per NQA-1 and two classified as Trending. Testing prior to the facility reconfiguration examined the facility response to throttling at the tank inlet, demonstrating increased sensitivity of flow instabilities to throttling within the two-phase region when compared to throttling at the lower sensitivity single-phase inlet region. Testing after the chimney reconfiguration began with a baseline test at conditions of 80% inventory fill and prototypic thermal power input of 2.1 MW t . In addition to establishing a reference for nominal system behavior and performance, repeat testing with multiple subsequent runs demonstrated strong repeatability between tests performed at the same conditions in this new configuration. These tests also examined if influences would occur to system behavior with installation of new higher-resolution instrumentation within the upper chimney. In this critical region where boiling and flashing phenomena dominate, the test results provided confidence that the new instrumentation does not uncharacteristically influence the observed behaviors. An inventory parametric series was then initiated to examine system behavior with the new chimney configuration at six varying initial inventory levels, ranging from high 80% to low 20% fill. Two-phase oscillations with similar peak and mean flow rates were observed when comparing to the previous mid tank configuration. Generally, similar system response trends with inventory were also observed, such as two phase oscillations suppressing as inventories were lowered. However, in one absolute inventory comparison at the highest fill of 80%, flow oscillations saw a gradual growth over the 4 hours of two-phase operation in the new lower tank inlet configuration, opposite of the gradual dampening observed in the mid tank inlet configuration. This can be attributed to, in part, a greater hydrostatic head pressure above the two-phase discharge region where the boiling front is developed. Furthermore, the change resulted in greater sensitivity to liquid degassing phenomena during single-phase heating, causing loop instabilities to form which trigged moderate flow degradation during the period approaching saturation and boiling conditions. This behavior had been observed previously under some conditions but was a common occurrence in recent testing with the newer lower tank inlet configuration. Initial observations from these first data sets suggest an overall larger window of stability for the mid tank inlet configuration compared to the lower tank inlet. Lastly, the lowest inventory fill test was repeated over an extended testing window to examine depletion behavior. Natural circulation flow and effective heat removal performance were observed during most of the testing period; only after the tank became fully drained (0% fill) did flow stagnate and violent geysering events occur. This early observation confirms one relative advantage over the mid tank inlet configuration, which stagnated under comparable conditions at ~20% inventory remaining in the tank.

42 ENGINEERING↗

Creating high-precision reference gas standards of 85Kr for groundwater age-dating

Absolute gas counting (AGC) was applied to two gas blends of 85Kr in argon-methane (P10) counting gas to establish a high-precision specific activity (Bq/cm3) reference value for characterizing 85Kr detection efficiency for groundwater age dating measurements. The AGC or length-compensated technique has been utilized by the metrology community for decades and is an accepted method for developing radioactive gas standards. The AGC capability at Pacific Northwest National Laboratory (PNNL) uses a set of nine unequal-length proportional counters with precisely-measured internal volumes, and a gas loading system with high-precision pressure and temperature sensors. A series of AGC measurements were collected at multiple pressures to determine the inverse pressure relationship (1/P) for 85Kr and define a wall-effect correction that accounts for events decaying into the detector wall and not depositing sufficient energy in the gas to be detected. In addition to the wall-effect, two additional corrections were evaluated and are discussed in detail. Specifically, the threshold effect which accounts for events deposited below the analysis threshold and a detection efficiency as a function of detector volume effect that was observed during analysis. A robust uncertainty model was developed using the Guide to the expression of Uncertainty in Measurements (GUM) approach. The combination of carefully scrutinized correction factors, precise measurements of pressure, temperature and detector volume, and robust counting statistics resulted in the determination of high-precision specific activity values with 0.50% or less total combined uncertainty for two Kr-in-P10 reference gas standards (KP10) that will enable new groundwater age-dating measurements at PNNL.

Kr-85↗

Ion fluxes and memory effects in an Ar–O 2 modulated radiofrequency-driven atmospheric pressure plasma jet

In this work we used molecular beam mass spectrometry to characterize ion fluxes produced by a modulated radiofrequency (RF)-driven atmospheric pressure plasma jet operating in a homogeneous gas environment (Ar + 1% O 2 ). The influence of the RF modulation frequency (100 Hz to 20 kHz) on the ion fluxes was investigated by time-resolved measurements, and the lifetimes of the dominant ions, O 2 + , NO + , O − , O 2 − and O 3 − , were found to be 28 ± 2, 117 ± 8, 7.3 ± 0.4, 17 ± 1 and 23 ± 2 μs, respectively. The absolute ion densities in the near afterglow region were found to be of the order of 1011 cm−3. Significant differences in the dynamics of the positive and negative ions were found; these are explained by the presence of electrons at similar densities in the afterglow produced by electron detachment reactions from negative ions due to the large concentrations of atomic oxygen and singlet delta oxygen. Transitions in ion flux dynamics for different modulation frequencies and at the startup of the plasma were analyzed together with intensified charge coupled device images recording the plasma propagation in order to assess the dynamics of plasma plume propagation and how it is impacted by ‘memory effects’. Quantitative measurements of the ion densities enabling these memory effects are reported. The results in this paper highlight the tremendous impact of memory effects on plasma propagation and the corresponding pre-ionization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Accurate determination of solvation free energies of neutral organic compounds from first principles

The main goal of molecular simulation is to accurately predict experimental observables of molecular systems. Another long-standing goal is to devise models for arbitrary neutral organic molecules with little or no reliance on experimental data. While separately these goals have been met to various degrees, for an arbitrary system of molecules they have not been achieved simultaneously. For biophysical ensembles that exist at room temperature and pressure, and where the entropic contributions are on par with interaction strengths, it is the free energies that are both most important and most difficult to predict. We compute the free energies of solvation for a diverse set of neutral organic compounds using a polarizable force field fitted entirely to ab initio calculations. The mean absolute errors (MAE) of hydration, cyclohexane solvation, and corresponding partition coefficients are 0.2 kcal/mol, 0.3 kcal/mol and 0.22 log units, i.e. within chemical accuracy. The model (ARROW FF) is multipolar, polarizable, and its accompanying simulation stack includes nuclear quantum effects (NQE). The simulation tools’ computational efficiency is on a par with current state-of-the-art packages. The construction of a wide-coverage molecular modelling toolset from first principles, together with its excellent predictive ability in the liquid phase is a major advance in biomolecular simulation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Near-Real-Time Model for Predicting Electricity Disruptions in Texas During Winter Storms

There has been an increase in extreme weather events, posing a threat to power grid systems, potentially influenced by factors such as population growth, changes in ecosystems, land cover, and land use in the service area, as well as the growth of certain vegetation types. This research seeks to develop a predictive model to mitigate potential damages caused by future winter storms. This research utilizes the Light Gradient Boosting Machine (LightGBM), incorporating the number of power outages experienced at the county level, geographic details, weather information, and lagged outage and lagged weather data. The developed models were broadly divided into two groups, with six models in each group - one group without optimization and another with optimization, totaling 12 trained models. For model optimization, Bayesian optimization was employed using Root Mean Squared Error (RMSE) as the objective function. In results, when comparing Group 2 (the optimized group) with Group 1 (the non-optimized group), it was found that optimization did not always lead to a reduction in RMSE and Mean Absolute Error (MAE). However, in terms of Mean Directional Accuracy (MDA), while all results in Group 1 were below the baseline accuracy of 0.33, all results in Group 2 exceeded 0.33, with some cases showing an increase of more than three times the baseline. The results indicated that, in the optimized model group, Population and Pressure were the most influential factors when using current weather data and geographical information. When using lagged data, lagged recorded outages and lagged Pressure emerged as the most significant factors. Among the 12 developed models, the L-1-2-O model showed the lowest RMSE and MAE, as well as the highest accuracy, with values of 390.62 households and 168.13 households, respectively. To normalize the RMSE and MAE values, each metric was divided by the average number of households among the counties in Texas. For the L-1-2-O model, the scaled RMSE was 0.88% and the scaled MAE was 0.38%. In terms of MDA, which indicates the accuracy of the prediction direction, the L-1-O model achieved the highest score of 0.41. Although this study focused on Texas, which suffered the greatest impact from the winter storms in 2021, with additional validation, the methodology used in this research could be applied to other regions.

Lee, Jangjae [Texas A & M Univ., College Station, ↗

Rate constants and third-body collision efficiencies for recombination of Na with OH and O2: Implications for flame inhibition by alkali salts

Flame inhibition by alkali metals has implications for solid fuel combustion, fire safety, and a number of industrial processes. While the mechanism of inhibition is fairly well understood, details related to thermodynamic properties and rate constants are still in question. In the present work, the recombination of Na with OH (R5) and O2 (R7), respectively, was characterized theoretically, and the implications for modeling laminar premixed hydrogen flames doped with sodium species were examined. Third-body collision efficiencies and low-pressure-limit rate constants were obtained using newly fitted ab initio-based potential energy surfaces, classical trajectories, and one-dimensional master equation calculations. The results are consistent with available experimental results and aid in the present modeling study by providing rate information for bath gases and conditions that remain unexplored experimentally. Chemical kinetic modeling of relative Na and absolute H and OH profiles in H2-fueled laminar, premixed flames doped with a sodium salt shows that the most important radical removal cycle is the sequence Na + OH (+M) → NaOH (+M) (R5), NaOH + H → Na + H2O (R12), even under oxidizing conditions. A secondary cycle, Na + O2 (+M) ⇄ NaO2 (+M) (R7), NaO2 + OH → NaOH + O2 (R14), is less important due to the low thermal stability of NaO2. In most flames, reaction R7 is partially equilibrated, and reaction R14 becomes rate-limiting for the second cycle. The flame analysis supports a lower value of k14 than indicated by recent work on KO2 + OH, but more work is required to confirm this.

Jasper, Ahren W.↗

AmeriFlux US-GL1 Stannard Rock

This is the AmeriFlux version of the carbon flux data for the site US-GL1 Stannard Rock. Site Description - Stannard Rock is located 39 km from the nearest shore (Keweenaw Peninsula) in Lake Superior, 44 miles NNE of Marquette, Michigan, and 24 miles ESE of Manitou Island. The site is located on the historic Stannard Rock Lighthouse, which was completed in 1882. Eddy covariance instrumentation was installed in 2008 by a network of scientists from both US and Canada, eventually to be called the Great Lakes Evaporation Network (GLEN). The intent of GLEN has been to provide observations of over-lake meteorology and evaporation, improve forecasting of Great Lakes water levels, and support a wide variety of stakeholders, including the National Weather Service (NWS), Environment and Climate Change Canada, National Oceanic and Atmospheric Administration, U.S. Coast Guard, recreational boaters and commercial shipping, emergency management officials, and the Great Lakes research community. The eddy covariance station along with other ancillary meteorological instrumentation is located at an approximate elevation of 39.2 meters above mean lake water level. Meteorological data from the lighthouse are sent to the National Data Buoy Center, where they can be viewed in real-time at http://www.ndbc.noaa.gov/station_page.php?station=stdm4 Uncorrected half-hour fluxes were computed directly on the logger using a 30-minute block averaging period as high-frequency data were not available. The half hour flux measurements downloaded from the datalogger were post-processed with the following filters and corrections. Latent and sensible heat and carbon dioxide fluxes were corrected with 2-D coordinate rotation. Although the primary objective of data collection at Stannard Rock was to quantify the evaporative flux, additional preliminary measurements of the carbon dioxide concentration and flux from the LI-7500 are also included in this dataset but it is advised to use the carbon data with caution. Carbon data reported in this dataset includes turbulent fluxes of CO2 with no storage correction (FC, µmol m-2 s-1) and CO2 density in mole fraction of wet air (CO2), which was originally output on the datalogger as average CO2 density (mg m-2 s-1) and converted into µmol mol-1 using air temperature and pressure in post-processing. Webb, Pearman, and Leuning terms were applied to account for density fluctuations for water vapor and CO2. Sonic path length, high-frequency attenuation and sensor separation were accounted for according to Horst and Massman, and the oxygen absorption correction for the KH2O hygrometer was also applied. Latent and sensible heat fluxes were assumed to be unrealistic above an absolute value of 1000 W m-2 and were removed. Both carbon flux (FC) and carbon dioxide mole fraction in wet air (CO2) and were assumed to be unrealistic above 1000 µmol m-2 s-1 and 1000 µmol mol-1 respectively. Spikes in latent and sensible heat and carbon fluxes and densities (often due to periods of precipitation) were identified by computing the mean and standard deviation over a moving, overlapping window of 336 half-hours (7 days), similar to Shao et al., and were removed when the flux was more than 1.5 standard deviations from the moving window’s mean. While Vickers and Mahrt use a threshold of 3.5 standard deviations from the mean, a conservative value of 1.5 was chosen due to the noisy nature of over-lake data at this particular site. This process was repeated twice for latent and sensible heat, and carbon dioxide fluxes and densities and therefore it is possible that some real, realistic data was filtered out in this process. No detrending was performed. As per AmeriFlux standards, no friction velocity (USTAR, m s-1) filtering was performed.

Spence, Chris↗

AmeriFlux FLUXNET-1F US-GL1 Stannard Rock

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-GL1 Stannard Rock. This is the FLUXNET version of the carbon flux data for the site US-GL1 Stannard Rock produced by applying the standard ONEFlux (1F) software. Site Description - Stannard Rock is located 39 km from the nearest shore (Keweenaw Peninsula) in Lake Superior, 44 miles NNE of Marquette, Michigan, and 24 miles ESE of Manitou Island. The site is located on the historic Stannard Rock Lighthouse, which was completed in 1882. Eddy covariance instrumentation was installed in 2008 by a network of scientists from both US and Canada, eventually to be called the Great Lakes Evaporation Network (GLEN). The intent of GLEN has been to provide observations of over-lake meteorology and evaporation, improve forecasting of Great Lakes water levels, and support a wide variety of stakeholders, including the National Weather Service (NWS), Environment and Climate Change Canada, National Oceanic and Atmospheric Administration, U.S. Coast Guard, recreational boaters and commercial shipping, emergency management officials, and the Great Lakes research community. The eddy covariance station along with other ancillary meteorological instrumentation is located at an approximate elevation of 39.2 meters above mean lake water level. Meteorological data from the lighthouse are sent to the National Data Buoy Center, where they can be viewed in real-time at http://www.ndbc.noaa.gov/station_page.php?station=stdm4 Uncorrected half-hour fluxes were computed directly on the logger using a 30-minute block averaging period as high-frequency data were not available. The half hour flux measurements downloaded from the datalogger were post-processed with the following filters and corrections. Latent and sensible heat and carbon dioxide fluxes were corrected with 2-D coordinate rotation. Although the primary objective of data collection at Stannard Rock was to quantify the evaporative flux, additional preliminary measurements of the carbon dioxide concentration and flux from the LI-7500 are also included in this dataset but it is advised to use the carbon data with caution. Carbon data reported in this dataset includes turbulent fluxes of CO2 with no storage correction (FC, µmol m-2 s-1) and CO2 density in mole fraction of wet air (CO2), which was originally output on the datalogger as average CO2 density (mg m-2 s-1) and converted into µmol mol-1 using air temperature and pressure in post-processing. Webb, Pearman, and Leuning terms were applied to account for density fluctuations for water vapor and CO2. Sonic path length, high-frequency attenuation and sensor separation were accounted for according to Horst and Massman, and the oxygen absorption correction for the KH2O hygrometer was also applied. Latent and sensible heat fluxes were assumed to be unrealistic above an absolute value of 1000 W m-2 and were removed. Both carbon flux (FC) and carbon dioxide mole fraction in wet air (CO2) and were assumed to be unrealistic above 1000 µmol m-2 s-1 and 1000 µmol mol-1 respectively. Spikes in latent and sensible heat and carbon fluxes and densities (often due to periods of precipitation) were identified by computing the mean and standard deviation over a moving, overlapping window of 336 half-hours (7 days), similar to Shao et al., and were removed when the flux was more than 1.5 standard deviations from the moving window’s mean. While Vickers and Mahrt use a threshold of 3.5 standard deviations from the mean, a conservative value of 1.5 was chosen due to the noisy nature of over-lake data at this particular site. This process was repeated twice for latent and sensible heat, and carbon dioxide fluxes and densities and therefore it is possible that some real, realistic data was filtered out in this process. No detrending was performed. As per AmeriFlux standards, no friction velocity (USTAR, m s-1) filtering was performed.

Spence, Chris [Environment and Climate Change Cana↗

Pressure, temperature, and orientation dependent thermal conductivity of pentaerythritol tetranitrate (PETN)

We use reverse non-equilibrium molecular dynamics to determine the thermal conductivity tensor, κ, of tetragonal pentaerythritol tetranitrate (PETN). The most stable form under standard ambient conditions (PETN I, with space group P4¯2 1 c) is considered in the temperature and pressure intervals 200–500 K and 0–8 GPa, which covers approximately the stability range for this polymorph. We compute κ along the [100] and [001] directions, which is enough to construct the full thermal conductivity tensor for a system with tetragonal symmetry. In addition, we also determine κ along the [010] direction and confirm that κ 100 ~ κ 010 , with less than 4% average absolute error between the two quantities. We observe an anisotropic response for κ, with κ 100 > κ 001 across the whole (T,P) interval, and 37% difference at 300 K, 0 GPa. Furthermore, we provide analytical functions to interpolate κ(P,T) within the fitting interval and serve as input for continuum-scale simulations.

36 MATERIALS SCIENCE↗

Absolute Band Intensity of the Iodine Monochloride Fundamental Mode for Infrared Sensing and Quantitative Analysis

Iodine monochloride (ICl) is a gaseous off-product of molten salt reactors; monitoring this heteronuclear diatomic is of great interest for both environmental and safety purposes. In this paper we investigate the possibility of infrared monitoring of ICl by measuring the far-infrared absorption cross section of its fundamental band near 381 cm -1 . We have performed quantitative studies of the neat gas in a 20 cm cell at 25, 35, 50 and 70 oC at multiple pressures up to ~ 9 Torr and investigated the temperature and pressure dependence of the band’s infrared cross section. Quantitative measurements were problematic due to sample adhesion to the cell walls and windows as well as reactions/possible hydrolysis of ICl to form HCl gas. Effects were mitigated by measuring only the neat gas, using short measurement times and subtracting out the partial pressure of the HCl(g). The integrated band strength is shown to be temperature independent and was found to be equal to 9.1 x 10 -19 (cm 2 /molecule) cm-1. As expected, the temperature dependence of the band profile showed only a small effect over this limited temperature range. Furthermore, we have also investigated using the absorption data along with inverse least squares multivariate methods for the quantitative monitoring of ICl effluent concentrations under different scenarios using infrared (standoff) sensing and compare these results with traditional Beer’s Law (univariate) techniques.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Surrogate-driven Variance-based Sensitivity Analysis of Thermal Storage Tanks in Integrated Energy Systems

Sensitivity analysis and uncertainty quantification are essential steps for enhancing the accuracy of computational models by identifying and mitigating uncertainties. This study focuses on these steps for the Thermal Energy Delivery System at Idaho National Laboratory, specifically targeting the thermocline tank. Using a Modelica/Dymola simulation model, the study perturbed various design parameters and boundary conditions, including shape factor, porosity, outlet temperature, inlet mass flow rate, and system pressure, to predict and quantify uncertainty in the tank’s ax- ial temperature. A dataset of over 1,000 simulations was generated, and surrogate models were developed using the pyMAISE (Michigan Artificial Intelligence Standard Environment) library, which is an Automatic Machine Learning library for nuclear engineering applications. The optimal model, a feedforward neural network with two hidden layers, achieved an R2 score above 0.99 and a mean absolute error below 1 Kelvin. Sensitivity analyses using Sobol indices and Fourier amplitude sensitivity testing methods on this surrogate model revealed that the inlet mass flow rate at initial timestamps and porosity significantly impacts predicted temperatures across all sensors and time steps.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Elucidating the Impact of Flow on Material-Sensitive Critical Heat Flux and Boiling Heat Transfer Coefficients: An Experimental Study with Various Materials

In this work, steady-state internal flow boiling critical heat flux (CHF) experiments were carried out at 10°C inlet subcooling and atmospheric pressure (84 kPa at an altitude of about 5300 feet) with mass flux ranging from 200 to 2,000 kg/m 2 -s on seven tube materials, including the accident-tolerant fuel cladding candidate FeCrAl (C26M) alloy. At a relatively low flow rate, the sensitivity of CHF to different materials was appreciable (the average difference among the tested materials was 19% at 200 kg/m 2 -s). As the absolute CHF differences stayed constant for higher flow rates, the increased flow rate led to reduced relative CHF differences among the tested materials (average relative difference of 15% at 1,000 kg/m 2 -s). FeCrAl alloy claddings that were oxidized under simulated Light Water Reactor (LWR) conditions yielded CHF comparable to as-received FeCrAl alloy cladding, with less than 1.8% difference. Experimental CHF results imply marginal material sensitivity impacts on the departure from nucleate boiling ratio in steady-state nuclear reactor cores. Yet, for accident progression analysis, material sensitivity may hold importance, as boiling behavior variation at low mass flux is appreciable. Macroscopic material parameters (surface wettability, surface roughness, and thermal properties) do not provide a suitable explanation for observed material-sensitive CHFs. Yet, surface roughness and thermal effusivity revealed power and linear relations, respectively, to the nucleate boiling heat transfer coefficients at low mass flux. At high mass flux, material sensitivity on nucleate boiling heat transfer significantly decreased due to the increased shear stress on boiling surface overwhelming material-related boiling implications.

36 MATERIALS SCIENCE↗

Absolute Hugoniot measurements in low-density plastic foams on the NIKE shock compression platform

The propagation of Mbar-range shock waves in low-density foam materials is of interest to target design in all approaches to inertial confinement fusion, high energy density physics, and laboratory astrophysics. We report absolute Hugoniot measurements for CH 1.72 N 0.086 O 0.37 plastic foams with 73 and 94 mg/cm 3 densities in the 32–107 km/s shock velocity range. The experiments were performed on the shock compression platform developed on the NIKE KrF laser facility at the U.S. Naval Research Laboratory. NIKE's 4 or 8-ns long flat-top laser pulses drive steady shock waves into foam targets at the ablative pressures of 1–7 Mbar. The propagation of the ablation and shock fronts is tracked continuously in time using streaked side-on monochromatic x-ray imaging radiography. The straight x−t trajectories of the shock and ablation fronts in the recorded streak images confirmed their steadiness. The SESAME tabulated equation of state predictions generally agrees with our Hugoniot data within a 95% confidence band. The experimental uncertainty of the evaluated shock density compression ratios remains large, indicating the need for more experiments and improved theoretical understanding of the strong shock propagation mechanisms in dry foams.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Rapid Determination of Uranium Isotopic Abundance from Cotton Swipes: Direct Extraction via a Planar Surface Reader and Coupling to a Microplasma Ionization Source

The collection of solid particulates and liquids from surfaces by the use of cloth swipes is fairly ubiquitous. In such methods, there is a continuous concern regarding the ability to locate and quantitatively sample the analyte species from the material. In this effort, we demonstrate the initial coupling of an Advion Plate Express plate reader to a liquid sampling–atmospheric pressure glow discharge (LS-APGD) microplasma ionization source with an Orbitrap mass spectrometer to perform uranium isotopic analyses of solution residues on cotton swipes. The Plate Express employs a sampling probe head to engage and seal against the swipe surface. Subsequentially, the analyte residues are desorbed and transported within a 2% HNO 3 electrolyte flow to the ionization source. Quantitative recoveries were observed following a single 30 s extraction step, with the absolute mass sampled per extraction being ~100 ng. While the intrasample variability in the analytical responses for triplicate sampling of the same swipe yield ~30% RSD, this lack of precision is offset by the ability to determine isotope ratios for enriched uranium specimens with a precision of better than 10% RSD. Pooled, intersample precision ( n = 9) was found to be <5%RSD across the various sample compositions. Finally, 235 U/ 238 U determinations (ranging from 0.053 to 1.806) were accurate with errors of <10%, absolute. The 234 U- and 236 U-inclusive ratios were determined with similar accuracy in enriched samples. While the driving force for the effort is in the realm of nuclear nonproliferation efforts, the ubiquitous use of cloth swipes across many application areas could benefit from this convenient approach, including the use of versatile, reduced-format mass spectrometer systems.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Prediction of Self-Diffusion in Binary Fluid Mixtures Using Artificial Neural Networks

Artificial neural networks (ANNs) were developed to accurately predict the self-diffusion constants for individual components in binary fluid mixtures. The ANNs were tested on an experimental database of 4328 self-diffusion constants from 131 mixtures containing 75 unique compounds. The presence of strong hydrogen bonding molecules may lead to clustering or dimerization resulting in non-linear diffusive behavior. To address this, self- and binary association energies were calculated for each molecule and mixture to provide information on intermolecular interaction strength and were used as input features to the ANN. An accurate, generalized ANN model was developed with an overall average absolute deviation of 4.1%. Forward input feature selection reveals the importance of critical properties and self-association energies along with other fluid properties. Additional ANNs were developed with subsets of the full input feature set to further investigate the impact of various properties on model performance. The results from two specific mixtures are discussed in additional detail: one providing an example of strong hydrogen bonding and the other an example of extreme pressure changes, with the ANN models predicting self-diffusion well in both cases.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗