Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerator Control C#”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

An application of modern control theory to jet propulsion systems

The control of an airbreathing turbojet engine by an onboard digital computer is studied. The approach taken is to model the turbojet engine as a linear, multivariable system whose parameters vary with engine operating environment. From this model adaptive closed-loop or feedback control laws are designed and applied to the acceleration of the turbojet engine.

Merrill, W. C.↗

Attitude dynamics of the Tether Elevator/Crawler System for micro-gravity applications

The Tether Elevator/Crawler System (TECS) consists of two end platforms tethered to opposite sides of the Space Station. A variable gravity laboratory is located on board an elevator which can crawl along the upper tether. This paper analyzes the elevator's attitude dynamics in order to evaluate its effect on microgravity applications. To this end, a simulation model is described and numerical results are given for a steady state case. It is shown that the elevator attitude dynamics, without attitude control, contributes additional spectral lines to the acceleration noise.

Vetrella, S.↗

Physiological Effects of Acceleration Observed During a Centrifuge Study of Pilot Performance

An investigation was conducted by the National Aeronautics and Space Administration, Ames Research Center, and the Naval Air Development Center, Aviation Medical Acceleration Laboratory, to study the effects of acceleration on pilot performance and to obtain some meaningful data for use in establishing tolerance to acceleration levels. The flight simulator used in the study was the Johnsville centrifuge operated as a closed loop system. The pilot was required to perform a control task in various sustained acceleration fields typical of those that Might be encountered by a pilot flying an entry vehicle in which he is seated in a forward-facing position. A special restraint system was developed and designed to increase the pilot's tolerance to these accelerations. The results of this study demonstrated that a well-trained subject, such as a test pilot, can adequately carry out a control task during moderately high accelerations for prolonged periods of time. The maximum levels of acceleration tolerated were approximately 6 times that of gravity for approximately 6 minutes, and varied slightly with the acceleration direction. The tolerance runs were in each case terminated by the subject. In all but two instances, the cause was extreme fatigue. On two occasions the subject terminated the run when he "grayed out." Although there were subjective and objective findings involving the visual and cardiovascular systems, the respiratory system yielded the more critical limiting factors. It would appear that these limiting factors were less severe during the "eyeballs-out" accelerations when compared with the "eyeballs-in" accelerations. These findings are explained on the basis of the influence that the inertial forces of acceleration have on the mechanics of respiration. A condensed version of this report was presented at the Annual Meeting of the Aerospace Medical Association, Miami Beach, May 5-11, 1960, in a paper entitled "Ability of Pilots to Perform a Control Task in Various Sustained Acceleration Fields."

Smedal, Harald A.↗

The EURISOL Multi-MW Target Unit: Neutronics, Dose Rate, Shielding and Activation Calculations

The EURISOL (The EURopean Isotope Separation On-Line Radioactive Ion Beam) project aims at designing a facility for producing high intensity radioactive ion beams, with unprecedented (two to three orders of magnitude higher) intensities, compared to the majority of the worldwide existing RIB facilities. For this purpose, a proton beam of energy 1 GeV and intensity up to 4 mA impinges on a liquid mercury target (the converter). The high neutron fluxes (in excess of 10{sup 15} n cm{sup -2} s{sup -1}) produced by spallation nuclear reactions in the converter induce fission on {sup 235}U targets surrounding the liquid mercury converter. In order to attain the intended high intensity radioactive ion beams, the appropriate configuration (geometry and materials) of the target unit components (converter, fission targets, moderators, reflectors) must be determined, to attain the highest possible fission rates in the uranium targets (in excess of 10{sup 15} fissions per second). The extremely high neutron and photon fluxes resulting from the operation of the target unit impose, for radiological protection and safety purposes, a careful assessment of the dose rates in the surrounding areas. Activation of the structural components must be studied. Thick shielding barriers must be designed. In this work, the so-called MAFF inspired target configuration, allowing a versatile operation, maintenance, remote control and storage of the fission targets is considered. The results obtained using the state-of-the-art Monte Carlo codes MCNPX and FLUKA are presented. The neutronics, dose rate, shielding and activation calculations, needed for radiological protection and safety assessment purposes are discussed.

43 PARTICLE ACCELERATORS↗

Thermophilic site-specific recombination system for rapid insertion of heterologous DNA into the Clostridium thermocellum chromosome

Clostridium thermocellum is an anaerobic thermophile capable of producing ethanol and other commodity chemicals from lignocellulosic biomass. The insertion of heterologous DNA into the C. thermocellum chromosome is currently achieved via a time-consuming homologous recombination process, where a single stable insertion can take 2–4 weeks or more to construct. In this work, we developed a thermostable version of the Serine recombinase Assisted Genome Engineering (tSAGE) approach for gene insertion in C. thermocellum utilizing a site-specific recombinase from Geobacillus sp. Y412MC61, enabling quick and easy insertion of DNA into the chromosome for accelerated genetic tool screening and heterologous gene expression. Using tSAGE, chromosomal insertion of plasmid DNA occurred at a maximum transformation efficiency of 5 × 10 3 CFU/µg, which is comparable to the transformation efficiency of a replicating control plasmid in C. thermocellum. Using tSAGE, we chromosomally integrated and characterized 17 reporter genes, 15 homologous and 31 heterologous constitutive promoters of varying strengths, 4 inducible promoters, and 5 riboswitches in C. thermocellum. We also determined that a 6–7 nucleotide gap between the ribosome binding site (RBS) and the start codon is optimal for high expression by employing a library of superfolder green fluorescent protein expression constructs driven by our strongest tested promoter (P clo1313_1194 ) with different distances between the RBS and start codon. The tools developed here will aid in accelerating C. thermocellum strain engineering for producing sustainable fuels and chemicals directly from plant biomass.

Biofuels↗

Independent Orbiter Assessment (IOA): Analysis of the displays and controls subsystem

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA approach features a top-down analysis of the hardware to determine failure modes, criticality, and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. This report documents the independent analysis results corresponding to the Orbiter Displays and Controls (D and C) subsystem hardware. The function of the D and C hardware is to provide the crew with the monitor, command, and control capabilities required for management of all normal and contingency mission and flight operations. The D and C hardware for which failure modes analysis was performed consists of the following: Acceleration Indicator (G-METER); Head Up Display (HUD); Display Driver Unit (DDU); Alpha/Mach Indicator (AMI); Horizontal Situation Indicator (HSI); Attitude Director Indicator (ADI); Propellant Quantity Indicator (PQI); Surface Position Indicator (SPI); Altitude/Vertical Velocity Indicator (AVVI); Caution and Warning Assembly (CWA); Annunciator Control Assembly (ACA); Event Timer (ET); Mission Timer (MT); Interior Lighting; and Exterior Lighting. Each hardware item was evaluated and analyzed for possible failure modes and effects. Criticality was assigned based upon the severity of the effect for each failure mode.

Trahan, W. H.↗

Machine learning for reducing noise in RF control signals at industrial accelerators

Industrial particle accelerators typically operate in dirtier environments than research accelerators, leading to increased noise in RF and electronic systems. Furthermore, given that industrial accelerators are mass produced, less attention is given to optimizing the performance of individual systems. As a result, industrial accelerators tend to underperform their own hardware capabilities. Improving signal processing for these machines will improve cost and time margins for deployment, helping to meet the growing demand for accelerators for medical sterilization, food irradiation, cancer treatment, and imaging. Our work focuses on using machine learning techniques to reduce noise in RF signals used for pulse-to-pulse feedback in industrial accelerators. Here we review our algorithms and observed results for simulated RF systems, and discuss next steps with the ultimate goal of deployment on industrial systems.

43 PARTICLE ACCELERATORS↗

ACCELERATED THERMAL AGING OF HARVESTED HYPALON JACKET FOR REMAINING USEFUL LIFE DETERMINATION AND DIAGNOSIS

For nuclear power plants (NPPs) that are considering second license renewal for their operation beyond 60 years, knowledge of long-term operation, condition monitoring, and viability for the reactor components including reactor pressure vessel, concrete structures, and cable systems is essential. Such knowledge will provide NPPs with a game plan to predict performance and to estimate costs that are associated with monitoring or replacement programs for the affected systems. For cable systems that encompass a wide variety of materials, manufacturers, and in-plant location, accelerated aging of harvested cable jacket and insulation can provide insight as to remaining useful life and methods for monitoring. Accelerated thermal aging in air at temperatures between 80°C and 120°C was carried out on a multi-conductor control rod cable that had been in-service for over 30 years and was made by Boston Insulated Wire with Hypalon cable jacket and ethylene-propylene rubber insulation. From elongation at break (EAB) measurements and supporting Arrhenius analysis of the jacket material, an activation energy of 97.84 kJ/mol was estimated and the time to degradation, as represented by 50% EAB at the expected maximum operating temperature of 45°C, was estimated as consistent with 80 years. These values were slightly below previous measurements and could either be attributed to in-service degradation or variations in material properties from a given manufacturer. In addition, results from indenter modulus measurements and Fourier transform infrared spectroscopy suggest possible markers that could be beneficial to monitor cable conditions.

Glass III, Samuel W.↗

Accelerated Thermal Aging of Harvested Hypalon Jacket for Remaining Useful Life Determination and Diagnosis

For nuclear power plants (NPPs) considering second license renewal for their operation beyond 60 years, knowledge of long-term operation, condition monitoring, and viability for the reactor components including reactor pressure vessel, concrete structures, and cable systems is essential. Such knowledge will provide NPPs with a game plan to predict performance and to estimate costs that are associated with monitoring or replacement programs for the affected systems. For cable systems that encompass a wide variety of materials, manufacturers, and in-plant location, accelerated aging of harvested cable jacket and insulation can provide insight as to remaining useful life and methods for monitoring. Accelerated thermal aging in air at temperatures between 80°C and 120°C was carried out on a multi-conductor control rod cable that had been in-service for over 30 years and was made by Boston Insulated Wire with Hypalon™ cable jacket and ethylene-propylene rubber insulation. From elongation at break (EAB) measurements and supporting Arrhenius analysis of the jacket material, an activation energy of 97.84 kJ/mol was estimated and the time to degradation, as represented by 50% EAB at the expected maximum operating temperature of 45°C, was estimated to be 80 years. These values were slightly below previous measurements on similar BIW Hypalon cable jacket and could either be attributed to in-service degradation or variations in material properties from process variations. In addition, results from indenter modulus measurements and Fourier transform infrared spectroscopy suggest possible markers that could be beneficial to monitor cable conditions.

cable aging, cable insulation, Hypalon, second lic↗

Control of transverse wakefields via phase-matched laser modes in parabolic plasma channels

The use of higher-order modes is proposed to control the transverse wakefield structure generated by a laser pulse propagating through a plasma channel. This can be done in the quasilinear regime in both the Laguerre-Gaussian and Hermite-Gaussian bases for appropriate laser-plasma parameters, independent of the longitudinal field. Control of the wake can be achieved by using modes of different mode numbers but with matched phase velocities to generate tunable, matched laser propagation. Furthermore, the wake can be tuned by modifying the initial phase and amplitude of each mode. In addition, it is shown that two different higher order modes can propagate at the same group velocity by appropriately tuning the frequencies. Geometric and frequency tuning of the laser driver allows for greater control of the transverse phase-space of the accelerated electron bunch.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

STOL Simulation Requirements for Development of Integrated Flight/propulsion Control Systems

The role and use of simulation as a design tool in developing integrated systems where design criteria is largely unavailable is well known. This paper addresses additional simulation needs for the development of Integrated Flight/Propulsion Control Systems (IFPCS) which will improve the probability of properly interpreting simulation results. These needs are based on recent experience with power approach flying qualities evaluations of an advanced fighter configuration which incorporated Short Takeoff and Landing (STOL) technologies and earlier experiences with power approach flying qualities evaluations on the AFTI/F-16 program. The use of motion base platforms with axial and normal degrees of freedom will help in evaluating pilot coupling and workload in the presence of high frequency low amplitude axial accelerations produced by high bandwidth airspeed controllers in a gusty environment.

Sanders, K. E.↗

Long-term ultrasonic monitoring of concrete affected by alkali-silica reaction

This article presents continuous monitoring results of alkali-silica reaction (ASR) development in concrete specimens for over 400 days using ultrasonic testing and expansion measurements. Eight concrete specimens with nonreactive aggregate (Control), reactive coarse aggregate, and reactive fine aggregates were cast with two reinforced confinement conditions. The specimens were conditioned in an environmental chamber with high temperature and humidity (38°C and 90% relative humidity) to accelerate the ASR development. A multichannel ultrasonic monitoring system was developed to collect ultrasonic signals automatically, and the expansions in three directions were measured periodically. Results showed that the relative velocity change could detect the ASR initiation in all reactive specimens and show a correlation with expansion in the early stage. However, these correlations are inconsistent for different ASR specimens, and the velocity change becomes less sensitive to ASR damage in the late stage (after 300 days). Irrecoverable velocity drop was observed during every chamber shutdown period, especially in specimens with higher levels of ASR damage. This phenomenon suggests that the nonlinear ultrasonic response caused by the ambient temperature variation may indicate the ASR damage.

Engineering↗

Definition of parameters for quality assurance of flattening filter free (FFF) photon beams in radiation therapy

Purpose: Flattening filter free (FFF) beams generated by medical linear accelerators have recently started to be used in radiotherapy clinical practice. Such beams present fundamental differences with respect to the standard filter flattened (FF) beams, making the generally used dosimetric parameters and definitions not always viable. The present study will propose possible definitions and suggestions for some dosimetric parameters for use in quality assurance of FFF beams generated by medical linacs in radiotherapy. Methods: The main characteristics of the photon beams have been analyzed using specific data generated by a Varian TrueBeam linac having both FFF and FF beams of 6 and 10 MV energy, respectively. Results: Definitions for dose profile parameters are suggested starting from the renormalization of the FFF with respect to the corresponding FF beam. From this point the flatness concept has been translated into one of 'unflatness' and other definitions have been proposed, maintaining a strict parallelism between FFF and FF parameter concepts. Conclusions: Ideas for quality controls used in establishing a quality assurance program when introducing FFF beams into the clinical environment are given here, keeping them similar to those used for standard FF beams. By following the suggestions in this report, the authors foresee that the introduction of FFF beams into a clinical radiotherapy environment will be as safe and well controlled as standard beam modalities using the existing guidelines.

07 ISOTOPE AND RADIATION SOURCES↗