Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerator Design Technology, and Operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Hot filament performance in a Freeman ion source

Here, we report on the simulation results of the hot tungsten filament behavior in a Freeman ions source installed in the LANL electro-magnetic isotope separator (EMIS). The Freeman source enables us to ionize and extract high intensity single-charge ion beams from different gases as well as from various solid materials in order to purify the content of a selected isotope. We have modified our LANSCE H– Ion Source Filament Model to calculate the ion source working parameters during a beam production cycle and estimate the ion source filament lifetime. Two main mass erosion processes of the hot cathode in a Freeman ion source are included: thermal evaporation and plasma sputtering. The initial working temperature of the ion source filament was estimated to be in range of 2400 to 2500 K. The filament model shows that the plasma sputtering rate is several magnitude of order higher than the thermal evaporation rate. The results of ion source modeling were compared with recorded data during the EMIS beam production runs using krypton noble gas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-plate interceptive electron beam energy diagnostic—Implementation and validation

A previous publication [P. D. McChesney, “Multi-plate interceptive electron beam energy diagnostic—Theoretical design,” AIP Adv. (submitted)] reported a new interceptive electron beam kinetic energy measurement technique based on the beam penetration depth within a stack of conductive plates and gave results on the theoretical design of such a device. This paper expands on this and gives further results on the actual implementation of the diagnostic. The device geometry and measurement electronics system are described in detail. A prototype version of the multi-plate diagnostic was fabricated and tested using an electron linear accelerator at the Idaho Accelerator Center (IAC). A high-precision magnetic spectrometer system was designed and built for the purpose of validating the multi-plate diagnostic’s energy measurement capabilities. It was found that the diagnostic provides electron beam energy estimates that are accurate to better than the 10% level.

43 PARTICLE ACCELERATORS↗

Theory of electron transport and emission from a semiconductor nanotip

An sufficient mass based model accounting for the conduction band quantization in a high aspect ratio semiconductor nanotip is developed to describe injected electron transport and subsequent electron emission from the nanotip. A transfer matrix formalism is used to treat electron scattering induced by the variation in the tip diameter and in the electron emission. Numerical assessment of the scattering and emission probabilities is performed for the diamond parametrized nanotip model. Our scattering and emission models are further combined with a Monte Carlo (MC) approach to simulate electron transport through the nanotip. The MC simulations, additionally accounting for the electron-phonon scattering and externally applied electric field, are performed for a minimal nanotip model and an equivalent width diamond slab. An effect of the level quantization, electron scattering due to the nanotip diameter variation, and electron-phonon scattering on the nanotip emission properties are identified and compared with the case of a bulk slab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Systematic evaluation of magnetic sensitivities of anisotropic magnetoresistive sensors at liquid helium temperature for superconducting cavities

Trapped magnetic flux in bulk superconductors reduces the quality factor Q in superconducting radio-frequency (SRF) cavities. However, the mechanisms underlying flux trapping and radio-frequency loss are not well understood. Detailed observation of the magnetic distributions is important for understanding such phenomena. Magnetic field mapping is useful for observing the magnetic field distribution around SRF cavities. Measuring the change in the magnetic field around the cavity elucidates the flux trapping behavior. Anisotropic magnetoresistive (AMR) sensors are inexpensive and small devices that can detect magnetic flux density. The magnetic sensitivities of AMR sensors need to be evaluated at liquid helium temperature for the magnetic field mapping of SRF cavities. In this study, a test stand was constructed to calibrate the magnetic sensitivities of AMR sensors in liquid helium, and 110 AMR sensors were tested using this stand. The magnetic sensitivities were evaluated systematically. A solenoid coil was used to control the uniform external magnetic field and to measure the magnetic sensitivity at low temperatures. All AMR sensors exhibited suitable sensitivities to the magnetic field around the SRF cavity. The variation in these sensitivities in all AMR sensors was ~1%. Further, the AMR sensors were found to have sufficient sensitivity for mapping the magnetic field around the exterior surface of the SRF cavity.

43 PARTICLE ACCELERATORS↗

FEbeam: Cavity and electron emission data conversion, processing, and analysis. A freeware toolkit for rf injectors

FEbeam is an all-in-one field emission data processing interface with the capability to analyze the field emission cathode performance in an rf injector by extracting the field enhancement factor, local field, and effective emission area from the Fowler–Nordheim equations. It also has the capability of processing beam imaging micrographs using its sister software, FEpic. Furthermore, the current version of FEbeam was designed for the Argonne Cathode Test-stand of the Argonne Wakefield Accelerator facility switch yard. With slight modifications, FEbeam could work for many rf field emission injectors. This software is open-source and can be found at GitHub.

43 PARTICLE ACCELERATORS↗

Robust method for broadband efficiency enhancement of electron photocathodes using optical interferences

In this work, we demonstrate the key features of an interference cathode using both simulations and experiments. We deposit Cs 3 Sb photocathodes on Ag to produce an interference enhanced photocathode with 2–5× quantum efficiency (QE) enhancement using a robust procedure that requires only a smooth metal substrate and QE monitoring during growth. We grow both an interference cathode (Ag substrate) and a typical photocathode (Si reference substrate) simultaneously to confirm that the effects are due to optical interactions with the substrate rather than photocathode composition or surface electron affinity differences. Growing the cathodes until the QE converges shows both the characteristic interference peaks during growth and the identical limiting case where the cathode is “infinitely thick,” in agreement with simulations. We also grow a cathode until the QE on Ag peaks and then stop the growth, demonstrating broadband QE enhancement.

36 MATERIALS SCIENCE↗

Quantum theory for 1D X-ray free electron laser

Classical 1D X-ray Free Electron Laser (X-ray FEL) theory has stood the test of time by guiding FEL design and development prior to any full-scale analysis. Future X-ray FELs and inverse-Compton sources, where photon recoil approaches an electron energy spread value, push the classical theory to its limits of applicability. After substantial efforts by the community to find what those limits are, there is no universally agreed upon quantum approach to design and development of future X-ray sources. We offer a new approach to formulate the quantum theory for 1D X-ray FELs that has an obvious connection to the classical theory, which allows for immediate transfer of knowledge between the two regimes. In conclusion, we exploit this connection in order to draw quantum mechanical conclusions about the quantum nature of electrons and generated radiation in terms of FEL variables.

42 ENGINEERING↗

Observation of quenching-induced magnetic flux trapping using a magnetic field and temperature mapping system

Highly efficient superconducting radio-frequency cavities exhibit low heat loss and are used as components in accelerators and superconducting devices due to their high Q-values. The precise location of magnetic flux trapping in cavities is necessary to identify its effects on the performance of superconducting cavities. In this study, we report a new combined mapping system to measure the temperature and magnetic field on the equator. The proposed system comprehensively maps local magnetic field changes as magnetic flux trapping due to quenching. Our experimental results show that magnetic flux trapping due to quenching increases the local surface resistance of superconducting cavities at 2 K. Thus, the proposed system elucidates the relationship between local flux trapping due to quenching and surface resistance in superconducting cavities and highlights the effect of quenching on the surface resistance. This system can aid in the development of superconducting cavities with higher Q values.

43 PARTICLE ACCELERATORS↗

29 mm Diameter Target Test Report

After numerous delays, the test of the 29 mm diameter target was conducted on 8/18/2017. The complete target design report, dated 8/15/2016, is reproduced below for completeness. This describes in detail the 10 disk target with varying thickness disks. The report presents and discusses the test results. In brief summary, there appears to have been multiple instrumentation errors. Measured temperatures, pressures and IR camera window temperature measurement are all suspect. All tests were done at 35 MeV, with 171 μA current, or 6 kW of beam power.

43 PARTICLE ACCELERATORS↗

Material replacement in quadrupoles of LANSCE DTL tank 1

The fields of short quadrupole magnets in the DTL tank 1 (T1) are calculated with CST EM Studio to evaluate effects of replacing their pole-tip and yoke material: high-purity iron by low-carbon steel. These quadrupoles, the strongest ones in the linac, are embedded into drift tubes, and their replacements may be required to have spare T1 drift tubes available.

43 PARTICLE ACCELERATORS↗