Search NASA⌕ Search

SEARCH · Search NASA

Results for “Adaptive coding and modulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

106 records · Page 6

Adaptive Discovery and Mixed-Variable Optimization of Next Generation Synthesizable Microelectronic Materials

Design of new microelectronic materials is characterized by several challenges such as high-dimensionality of the atomic structure-composition variable space, formidable cost of directly using high-fidelity simulations for design optimization, dispersity in literature-reported similar materials and synthesis methods, complex physical mechanisms, and mixed qualitative and quantitative design variables that lead to a disjointed design space. Even though machine learning (ML) techniques have been employed to expedite materials innovation, existing methods treat ML and design optimization as two separate processes, failing to resolve the fundamental challenges associated with high dimensionality and mixed-variable complexity. We have developed a ML enhanced mixed-variable material design optimization framework to efficiently extract useful information from existing data in literature and physics-based simulations to guide the autonomous search for optimal materials. Our proposed framework is composed of four computational modules: (1) a natural language processing (NLP) based virtual screening module, (2) classification based concept exploration module, (3) a density functional theory (DFT)-based high-fidelity evaluation model, and (4) a novel latent-variable Gaussian process (LVGP) ML model for mixed-variable problems with uncertainty quantification, which seamlessly integrates with Bayesian Optimization (BO) and achieves superb efficiency through embedded physics-based dimension reduction. Our approach is demonstrated and validated using the testbed of functional materials exhibiting metal-insulation transitions (MITs), with the targeted reversible resistivity changes (∼10^5) near room temperature. At the end of the 30-month project, we have developed a series of new ML techniques using NLP, conditional variational autoencoders, active learning, latent-variable Gaussian processes, integrated with Bayesian optimization. Our project has resulted in new predicted MITs compounds and improved understanding of MITs microscopic mechanisms, which in turn will revolutionize microelectronics science to provide energy-saving solutions. Our research has improved both creativity and efficiency in transforming rare-event discoveries of new functional materials to persistent innovations. In addition to open-sourcing the online MIT database and the classification model, the LVGP open source code has been downloaded more than 15,000 times within two years. More than 40 MIT compounds have been identified and many have been pursued experimentally via collaborators. The research results are published in close to 20 collaborative papers in high-impact journals, such as Chem. Mater., Appl. Phys. Rev., Sci. Rep., among others of design space.

36 MATERIALS SCIENCE↗

Toward the development of intrafraction tumor deformation tracking using a dynamic multi-leaf collimator

Purpose: Intrafraction deformation limits targeting accuracy in radiotherapy. Studies show tumor deformation of over 10 mm for both single tumor deformation and system deformation (due to differential motion between primary tumors and involved lymph nodes). Such deformation cannot be adapted to with current radiotherapy methods. The objective of this study was to develop and experimentally investigate the ability of a dynamic multi-leaf collimator (DMLC) tracking system to account for tumor deformation. Methods: To compensate for tumor deformation, the DMLC tracking strategy is to warp the planned beam aperture directly to conform to the new tumor shape based on real time tumor deformation input. Two deformable phantoms that correspond to a single tumor and a tumor system were developed. The planar deformations derived from the phantom images in beam's eye view were used to guide the aperture warping. An in-house deformable image registration software was developed to automatically trigger the registration once new target image was acquired and send the computed deformation to the DMLC tracking software. Because the registration speed is not fast enough to implement the experiment in real-time manner, the phantom deformation only proceeded to the next position until registration of the current deformation position was completed. The deformation tracking accuracy was evaluated by a geometric target coverage metric defined as the sum of the area incorrectly outside and inside the ideal aperture. The individual contributions from the deformable registration algorithm and the finite leaf width to the tracking uncertainty were analyzed. Clinical proof-of-principle experiment of deformation tracking using previously acquired MR images of a lung cancer patient was implemented to represent the MRI-Linac environment. Intensity-modulated radiation therapy (IMRT) treatment delivered with enabled deformation tracking was simulated and demonstrated. Results: The first experimental investigation of adapting to tumor deformation has been performed using simple deformable phantoms. For the single tumor deformation, the A{sub u}+A{sub o} was reduced over 56% when deformation was larger than 2 mm. Overall, the total improvement was 82%. For the tumor system deformation, the A{sub u}+A{sub o} reductions were all above 75% and the total A{sub u}+A{sub o} improvement was 86%. Similar coverage improvement was also found in simulating deformation tracking during IMRT delivery. The deformable image registration algorithm was identified as the dominant contributor to the tracking error rather than the finite leaf width. The discrepancy between the warped beam shape and the ideal beam shape due to the deformable registration was observed to be partially compensated during leaf fitting due to the finite leaf width. The clinical proof-of-principle experiment demonstrated the feasibility of intrafraction deformable tracking for clinical scenarios. Conclusions: For the first time, we developed and demonstrated an experimental system that is capable of adapting the MLC aperture to account for tumor deformation. This work provides a potentially widely available management method to effectively account for intrafractional tumor deformation. This proof-of-principle study is the first experimental step toward the development of an image-guided radiotherapy system to treat deforming tumors in real-time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Technical Note: A fast online adaptive replanning method for VMAT using flattening filter free beams

Purpose: To develop a fast replanning algorithm based on segment aperture morphing (SAM) for online replanning of volumetric modulated arc therapy (VMAT) with flattening filter free (FFF) beams. Methods: A software tool was developed to interface with a VMAT research planning system, which enables the input and output of beam and machine parameters of VMAT plans. The SAM algorithm was used to modify multileaf collimator positions for each segment aperture based on the changes of the target from the planning (CT/MR) to daily image [CT/CBCT/magnetic resonance imaging (MRI)]. The leaf travel distance was controlled for large shifts to prevent the increase of VMAT delivery time. The SAM algorithm was tested for 11 patient cases including prostate, pancreatic, and lung cancers. For each daily image set, three types of VMAT plans, image-guided radiation therapy (IGRT) repositioning, SAM adaptive, and full-scope reoptimization plans, were generated and compared. Results: The SAM adaptive plans were found to have improved the plan quality in target and/or critical organs when compared to the IGRT repositioning plans and were comparable to the reoptimization plans based on the data of planning target volume (PTV)-V100 (volume covered by 100% of prescription dose). For the cases studied, the average PTV-V100 was 98.85% ± 1.13%, 97.61% ± 1.45%, and 92.84% ± 1.61% with FFF beams for the reoptimization, SAM adaptive, and repositioning plans, respectively. The execution of the SAM algorithm takes less than 10 s using 16-CPU (2.6 GHz dual core) hardware. Conclusions: The SAM algorithm can generate adaptive VMAT plans using FFF beams with comparable plan qualities as those from the full-scope reoptimization plans based on daily CT/CBCT/MRI and can be used for online replanning to address interfractional variations.

60 APPLIED LIFE SCIENCES↗

Dynamic PRA-Based Estimation of PWR Coping Time Using a Surrogate Model for Accident Tolerant Fuel

In this study, we propose an interpolation-based response surface surrogate methodology to manage a large number of scenarios in dynamic probabilistic risk assessment. It adopts the shape Dynamic Time Warping algorithm to cluster the interpolation neighborhood from time series sample data. The interpolation method was adapted from Taylor Kriging to allow a reduced-order model of the Taylor series. In order to demonstrate its applicability to complex issues in risk assessment for nuclear engineering, an example risk response surface to estimate emergency core cooling system (ECCS) criteria for triplex silicon carbide (SiC) accident-tolerant fuel was constructed. The response surface was exploited to estimate the cumulative failure probability of the fuel cladding structure due to the uncertainties in operator actions and safety systems. The functional failures were assessed based on a combination of individual layer failures computed by coupling Risk Analysis Virtual Environment software with a pressurized water reactor 1000-MW(electric) RELAP5 model and the in-house fuel performance assessment module. Results showed that SiC cladding failure probability spiked less than 1 min after a large-break loss-of- coolant accident whenever the current ECCS criteria for Zircaloy-4 (Zr-4) cladding was used. However, it still provides an increased safety margin of three orders of magnitude compared to Zr-4. This positive margin could be utilized to relax active ECCS requirements by allowing deviations of up to 450 s in its actuation time. The proposed surrogate methodology generated a response surface of SiC cladding failure probability reasonably well, with a significant savings of computation time. This methodology is expected to be useful in the analysis of system response with complex uncertainty sources.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Practical Method of Adaptive Radiotherapy for Prostate Cancer Using Real-Time Electromagnetic Tracking

Purpose: We have created an automated process using real-time tracking data to evaluate the adequacy of planning target volume (PTV) margins in prostate cancer, allowing a process of adaptive radiotherapy with minimal physician workload. We present an analysis of PTV adequacy and a proposed adaptive process. Methods and Materials: Tracking data were analyzed for 15 patients who underwent step-and-shoot multi-leaf collimation (SMLC) intensity-modulated radiation therapy (IMRT) with uniform 5-mm PTV margins for prostate cancer using the Calypso Registered-Sign Localization System. Additional plans were generated with 0- and 3-mm margins. A custom software application using the planned dose distribution and structure location from computed tomography (CT) simulation was developed to evaluate the dosimetric impact to the target due to motion. The dose delivered to the prostate was calculated for the initial three, five, and 10 fractions, and for the entire treatment. Treatment was accepted as adequate if the minimum delivered prostate dose (D{sub min}) was at least 98% of the planned D{sub min}. Results: For 0-, 3-, and 5-mm PTV margins, adequate treatment was obtained in 3 of 15, 12 of 15, and 15 of 15 patients, and the delivered D{sub min} ranged from 78% to 99%, 96% to 100%, and 99% to 100% of the planned D{sub min}. Changes in D{sub min} did not correlate with magnitude of prostate motion. Treatment adequacy during the first 10 fractions predicted sufficient dose delivery for the entire treatment for all patients and margins. Conclusions: Our adaptive process successfully used real-time tracking data to predict the need for PTV modifications, without the added burden of physician contouring and image analysis. Our methods are applicable to other uses of real-time tracking, including hypofractionated treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-E-BRE-04: An Online Replanning Algorithm for VMAT

Purpose: To develop a fast replanning algorithm based on segment aperture morphing (SAM) for online replanning of volumetric modulated arc therapy (VMAT) with flattening filtered (FF) and flattening filter free (FFF) beams. Methods: A software tool was developed to interface with a VMAT planning system ((Monaco, Elekta), enabling the output of detailed beam/machine parameters of original VMAT plans generated based on planning CTs for FF or FFF beams. A SAM algorithm, previously developed for fixed-beam IMRT, was modified to allow the algorithm to correct for interfractional variations (e.g., setup error, organ motion and deformation) by morphing apertures based on the geometric relationship between the beam's eye view of the anatomy from the planning CT and that from the daily CT for each control point. The algorithm was tested using daily CTs acquired using an in-room CT during daily IGRT for representative prostate cancer cases along with their planning CTs. The algorithm allows for restricted MLC leaf travel distance between control points of the VMAT delivery to prevent SAM from increasing leaf travel, and therefore treatment delivery time. Results: The VMAT plans adapted to the daily CT by SAM were found to improve the dosimetry relative to the IGRT repositioning plans for both FF and FFF beams. For the adaptive plans, the changes in leaf travel distance between control points were < 1cm for 80% of the control points with no restriction. When restricted to the original plans' maximum travel distance, the dosimetric effect was minimal. The adaptive plans were delivered successfully with similar delivery times as the original plans. The execution of the SAM algorithm was < 10 seconds. Conclusion: The SAM algorithm can quickly generate deliverable online-adaptive VMAT plans based on the anatomy of the day for both FF and FFF beams.

60 APPLIED LIFE SCIENCES↗

Fast intensity-modulated arc therapy based on 2-step beam segmentation

Purpose: Single or few arc intensity-modulated arc therapy (IMAT) is intended to be a time saving irradiation method, potentially replacing classical intensity-modulated radiotherapy (IMRT). The aim of this work was to evaluate the quality of different IMAT methods with the potential of fast delivery, which also has the possibility of adapting to the daily shape of the target volume. Methods: A planning study was performed. Novel double and triple IMAT techniques based on the geometrical analysis of the target organ at risk geometry (2-step IMAT) were evaluated. They were compared to step and shoot IMRT reference plans generated using direct machine parameter optimization (DMPO). Volumetric arc (VMAT) plans from commercial preclinical software (SMARTARC) were used as an additional benchmark to classify the quality of the novel techniques. Four cases with concave planning target volumes (PTV) with one dominating organ at risk (OAR), viz., the PTV/OAR combination of the ESTRO Quasimodo phantom, breast/lung, spine metastasis/spinal cord, and prostate/rectum, were used for the study. The composite objective value (COV) and other parameters representing the plan quality were studied. Results: The novel 2-step IMAT techniques with geometry based segment definition were as good as or better than DMPO and were superior to the SMARTARC VMAT techniques. For the spine metastasis, the quality measured by the COV differed only by 3%, whereas the COV of the 2-step IMAT for the other three cases decreased by a factor of 1.4-2.4 with respect to the reference plans. Conclusions: Rotational techniques based on geometrical analysis of the optimization problem (2-step IMAT) provide similar or better plan quality than DMPO or the research version of SMARTARC VMAT variants. The results justify pursuing the goal of fast IMAT adaptation based on 2-step IMAT techniques.

60 APPLIED LIFE SCIENCES↗

SU-E-T-334: Dosimetric Impacts of Organ at Risk (OAR) Contour Errors in Prostate Volumetric Modulated Arc Therapy (VMAT) Planning: A Sensitivity Study

Purpose: To investigate the dosimetric impacts of OAR contour errors in prostate VMAT planning with a sensitivity analysis method. Methods: Ten randomly selected prostate VMAT patients were used to simulate OAR contour error in rectum and bladder. For each OAR 12 even spaced contour control points were selected in every three slices. For each simulation, only one of the control points was simulated to move inwards or outwards by up to 6 voxels and coordinates of adjacent voxels to that moving control point were moved accordingly with a 3D-spline smooth function. An in-house software was used to predict OARs dosimetric endpoints based on geometric relationship between PTV and OAR. In this study, the V75, V70, V65, V60 of rectum and V80, V75, V70, V65 of bladder with and without perturbed contours were calculated and compared. Results: The percentage of OAR dose volume difference around the reference OAR contours were plotted as iso-error lines overlaid on CT images. The significant difference was shown in OAR contours adjacent to the PTV where high dose gradient exists. When one of the 12 points adjacent to the PTV moved up to 6 voxels, maximum errors of 1.99%, 2.46%, 2.89%, and 3.19% were found in V75, V70, V65, and V60 of the rectum, and 1.59%, 1.67%, 1.87%, and 1.90% were found in V80, V75, V70, and V65 of the bladder, respectively. Conclusion: We can quantify the dosimetric impact of OAR contouring error by evaluating the percentage of OAR dose volume changes in prostate VMAT planning. For the adaptive radiation therapy, the iso-error lines can provide the planner a guideline that which portion of contour needed to be checked carefully because dosimetric sensitivity of contour errors are different for different part of contours.

60 APPLIED LIFE SCIENCES↗

Monte Carlo simulation and patient dosimetry for a kilovoltage cone-beam CT unit

Purpose: The purpose of this work is to characterize the x-ray volume imager (XVI), the cone-beam computed tomography (CBCT) unit mounted on the Elekta Synergy linac, with F1 bowtie filter and to calculate the three-dimensional dose delivered to patients using volumetric acquisition. Methods: The XVI is modeled in detail using a new Monte Carlo (MC) code, BEAMPP, under development at the National Research Council Canada. In this investigation, a new component module is developed to accurately model the unit's bowtie filter used in conjunction with the available beam collimators at the clinical energy of 120 kV. The modeling is compared against percentage depth dose (PDD) and profile measurements. Kilovoltage radiation beams' phase space files are also analyzed. The authors also describe a method for the absolute dose calibration of the MC model of the CBCT unit when used in a clinical volumetric acquisition mode. Finally, they calculate three-dimensional patient dose from CBCT image acquisition in three clinical cases of interest: Pelvis, lung, and head and neck. Results: The agreement between measurement and MC is shown to be very good: Within {+-}2% for the PDD and within {+-}3.5% inside the radiation field for all the collimators with the F1 bowtie filter. A full account of the absolute calibration method is given and dose calculation is validated against ion chamber measurements in different locations of a plastic phantom. Calculations and experiments agree within {+-}2% or better in both at the center and the periphery of the phantom, with worst agreement of 4.5% at the surface of the phantom and for one specific combination of collimator and filter. Patient dose from CBCT scan reveals that dose to tissue is between 2 and 2.5 cGy for a pelvis or a lung full acquisition. For H and N dose to tissue is 5 cGy, with the unit presets used in this work. Dose to bony structures can be two to three times higher than dose to tissue. Conclusions: The XVI CBCT unit has been fully modeled including the F1 bowtie filter. Absolute dose distribution from the unit has been successfully validated. Full MC patient dose calculation has shown that the three-dimensional dose distribution from CBCT is complex. Patient dose from CBCT exposure cannot be completely accounted for by using a numerical factor as an estimate of the dose at the center of the body. Furthermore, additional dose to bone should be taken into account when adopting any IGRT strategy and weighed vs the unquestionable benefits of the technique in order to optimize treatment. Full three-dimensional dose calculation is recommended if patient dose from CBCT is to be integrated in any adaptive planning strategy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Development and validation of a measurement-based source model for kilovoltage cone-beam CT Monte Carlo dosimetry simulations

Purpose: The purpose of this study is to adapt an equivalent source model originally developed for conventional CT Monte Carlo dose quantification to the radiation oncology context and validate its application for evaluating concomitant dose incurred by a kilovoltage (kV) cone-beam CT (CBCT) system integrated into a linear accelerator.Methods: In order to properly characterize beams from the integrated kV CBCT system, the authors have adapted a previously developed equivalent source model consisting of an equivalent spectrum module that takes into account intrinsic filtration and an equivalent filter module characterizing the added bowtie filtration. An equivalent spectrum was generated for an 80, 100, and 125 kVp beam with beam energy characterized by half-value layer measurements. An equivalent filter description was generated from bowtie profile measurements for both the full- and half-bowtie. Equivalent source models for each combination of equivalent spectrum and filter were incorporated into the Monte Carlo software package MCNPX. Monte Carlo simulations were then validated against in-phantom measurements for both the radiographic and CBCT mode of operation of the kV CBCT system. Radiographic and CBCT imaging dose was measured for a variety of protocols at various locations within a body (32 cm in diameter) and head (16 cm in diameter) CTDI phantom. The in-phantom radiographic and CBCT dose was simulated at all measurement locations and converted to absolute dose using normalization factors calculated from air scan measurements and corresponding simulations. The simulated results were compared with the physical measurements and their discrepancies were assessed quantitatively.Results: Strong agreement was observed between in-phantom simulations and measurements. For the radiographic protocols, simulations uniformly underestimated measurements by 0.54%–5.14% (mean difference =−3.07%, SD = 1.60%). For the CBCT protocols, simulations uniformly underestimated measurements by 1.35%–5.31% (mean difference =−3.42%, SD = 1.09%).Conclusions: This work demonstrates the feasibility of using a measurement-based kV CBCT source model to facilitate dose calculations with Monte Carlo methods for both the radiographic and CBCT mode of operation. While this initial work validates simulations against measurements for simple geometries, future work will involve utilizing the source model to investigate kV CBCT dosimetry with more complex anthropomorphic phantoms and patient specific models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tolerance levels of EPID-based quality control for volumetric modulated arc therapy

Purpose: Volumetric modulated arc therapy (VMAT) includes features such as a variable dose rate and gantry speed in addition to the beam modulation achieved with multileaf collimator (MLC) motion patterns employed in intensity modulated radiotherapy. Three tests have previously been proposed for the evaluation of the performance of VMAT delivery. In order to enable a convenient and accurate routine machine quality control (QC) program, the present study proposes tolerance levels for these tests based on a department-wide implementation of an electronic portal imaging device (EPID)-based QC. Methods: Three different VMAT tests--a picket fence (PF) test, a dose rate versus gantry speed (DRGS) test, and a dose rate versus MLC leaf speed (DRMLC) test--were performed on nine accelerators using two different EPIDs (aS1000 and aS500, Varian Medical Systems). All tests were repeated six times for each accelerator. The images were analyzed using an in-house-developed software. For the PF test, the positions and widths of individual MLC leaf gaps were compared to the mean value. In the DRGS and DRMLC tests, different combinations of dose rate, gantry speed, and MLC leaf speed were used to deliver identical doses to separate parts of the EPID. The tests were evaluated by looking for deviations in the constancy of the measured dose for the preset combinations of dose rate, gantry speed, and MLC leaf speed. Results: For the PF test, a 0.3 mm tolerance level was suggested for the positioning of the MLC leaves. The tolerance level for the gap width was 0.5 mm. For the DRGS and DRMLC tests, a 3% tolerance level was proposed. Conclusions: With the adapted levels of tolerance for an EPID-based approach, the PF, the DRGS, and the DRMLC tests offer a convenient and accurate machine QC program for linear accelerators used for VMAT.

07 ISOTOPE AND RADIATION SOURCES↗

Technical Note: SCUDA: A software platform for cumulative dose assessment

Purpose: Accurate tracking of anatomical changes and computation of actually delivered dose to the patient are critical for successful adaptive radiation therapy (ART). Additionally, efficient data management and fast processing are practically important for the adoption in clinic as ART involves a large amount of image and treatment data. The purpose of this study was to develop an accurate and efficient Software platform for CUmulative Dose Assessment (SCUDA) that can be seamlessly integrated into the clinical workflow. Methods: SCUDA consists of deformable image registration (DIR), segmentation, dose computation modules, and a graphical user interface. It is connected to our image PACS and radiotherapy informatics databases from which it automatically queries/retrieves patient images, radiotherapy plan, beam data, and daily treatment information, thus providing an efficient and unified workflow. For accurate registration of the planning CT and daily CBCTs, the authors iteratively correct CBCT intensities by matching local intensity histograms during the DIR process. Contours of the target tumor and critical structures are then propagated from the planning CT to daily CBCTs using the computed deformations. The actual delivered daily dose is computed using the registered CT and patient setup information by a superposition/convolution algorithm, and accumulated using the computed deformation fields. Both DIR and dose computation modules are accelerated by a graphics processing unit. Results: The cumulative dose computation process has been validated on 30 head and neck (HN) cancer cases, showing 3.5 ± 5.0 Gy (mean±STD) absolute mean dose differences between the planned and the actually delivered doses in the parotid glands. On average, DIR, dose computation, and segmentation take 20 s/fraction and 17 min for a 35-fraction treatment including additional computation for dose accumulation. Conclusions: The authors developed a unified software platform that provides accurate and efficient monitoring of anatomical changes and computation of actually delivered dose to the patient, thus realizing an efficient cumulative dose computation workflow. Evaluation on HN cases demonstrated the utility of our platform for monitoring the treatment quality and detecting significant dosimetric variations that are keys to successful ART.

60 APPLIED LIFE SCIENCES↗

HarDWR - Harmonized Water Rights Records

A dataset within the Harmonized Database of Western U.S. Water Rights (HarDWR). For a detailed description of the database, please see the meta-record v2.0. Changelog v2.0 - Recalculated based on data sourced from WestDAAT - Changed using a Site ID column to identify unique records to using aa combination of Site ID and Allocation ID - Removed the Water Management Area (WMA) column from the harmonized records. The replacement is a separate file which stores the relationship between allocations and WMAs. This allows for allocations to contribute to water right amounts to multiple WMAs during the subsequent cumulative process. - Added a column describing a water rights legal status - Added "Unspecified" was a water source category - Added an acre-foot (AF) column - Added a column for the classification of the right's owner v1.02 - Added a .RData file to the dataset as a convenience for anyone exploring our code. This is an internal file, and the one referenced in analysis scripts as the data objects are already in R data objects. v1.01 - Updated the names of each file with an ID number less than 3 digits to include leading 0s v1.0 - Initial public release Description Here we present an updated database of Western U.S. water right records. This database provides consistent unique identifiers for each water right record, and a consistent categorization scheme that puts each water right record into one of seven broad use categories. These data were instrumental in conducting a study of the multi-sector dynamics of inter-sectoral water allocation changes though water markets (Grogan et al., *in review*). Specifically, the data were formatted for use as input to a process-based hydrologic model, Water Balance Model (WBM), with a water rights module (Grogan et al., *in review*). While this specific study motivated the development of the database presented here, water management in the U.S. West is a rich area of study (e.g., Anderson and Woosly, 2005; Tidwell, 2014; Null and Prudencio, 2016; Carney et al., 2021) so releasing this database publicly with documentation and usage notes will enable other researchers to do further work on water management in the U.S. West. We produced the water rights database presented here in four main steps: (1) data collection, (2) data quality control, (3) data harmonization, and (4) generation of cumulative water rights curves. Each of steps (1)-(3) had to be completed in order to produce (4), the final product that was used in the modeling exercise in Grogan et al. (*in review*). All data in each step is associated with a spatial unit called a Water Management Area (WMA), which is the unit of water right administration utilized by the state in which the right came from. Steps (2) and (3) required use to make assumptions and interpretation, and to remove records from the raw data collection. We describe each of these assumptions and interpretations below so that other researchers can choose to implement alternative assumptions an interpretation as fits their research aims. Motivation for Changing Data Sources The most significant change has been a switch from collecting the raw water rights directly from each state to using the water rights records presented in WestDAAT, a product of the Water Data Exchange (WaDE) Program under the Western States Water Council (WSWC). One of the main reasons for this is that each state of interest is a member of the WSWC, meaning that WaDE is partially funded by these states, as well as many universities. As WestDAAT is also a database with consistent categorization, it has allowed us to spend less time on data collection and quality control and more time on answering research questions. This has included records from water right sources we had previously not known about when creating v1.0 of this database. The only major downside to utilizing the WestDAAT records as our raw data is that further updates are tied to when WestDAAT is updated, as some states update their public water right records daily. However, as our focus is on cumulative water amounts at the regional scale, it is unlikely most records updates would have a significant effect on our results. The structure of WestDAAT led to several important changes to how HarWR is formatted. The most significant change is that WaDE has calculated a field known as `SiteUUID`, which is a unique identifier for the Point of Diversion (POD), or where the water is drawn from. This separate from `AllocationNativeID`, which is the identifier for the allocation of water, or the amount of water associated with the water right. It should be noted that it is possible for a single site to have multiple allocations associated with it and for an allocation to be able to be extracted from multiple sites. The site-allocation structure has allowed us to adapt a more consistent, and hopefully more realistic, approach in organizing the water right records than we had with HarDWR v1.0. This was incredibly helpful as the raw data from many states had multiple water uses within a single field within a single row of their raw data, and it was not always clear if the first water use was the most important, or simply first alphabetically. WestDAAT has already addressed this data quality issue. Furthermore, with v1.0, when there were multiple records with the same water right ID, we selected the largest volume or flow amount and disregarded the rest. As WestDAAT was already a common structure for disparate data formats, we were better able to identify sites with multiple allocations and, perhaps more importantly, allocations with multiple sites. This is particularly helpful when an allocation has sites which cross WMA boundaries, instead of just assigning the full water amount to a single WMA we are now able to divide the amount of water between the number of relevant WMAs. As it is now possible to identify allocations with water used in multiple WMAs, it is no longer practical to store this information within a single column. Instead the stAllocationToWMATab.csv file was created, which is an allocation by WMA matrix containing the percent Place of Use area overlap with each WMA. We then use this percentage to divide the allocation's flow amount between the given WMAs during the cumulation process to hopefully provide more realistic totals of water use in each area. However, not every state provides areas of water use, so like HarDWR v1.0, a hierarchical decision tree was used to assign each allocation to a WMA. First, if a WMA could be identified based on the allocation ID, then that WMA was used; typically, when available, this applied to the entire state and no further steps were needed. Second was the spatial analysis of Place of Use to WMAs. Third was a spatial analysis of the POD locations to WMAs, with the assumption that allocation's POD is within the WMA it should belong to; if an allocation still had multiple WMAs based on its POD locations, then the allocation's flow amount would be divided equally between all WMAs. The fourth, and final, process was to include water allocations which spatially fell outside of the state WMA boundaries. This could be due to several reasons, such as coordinate errors / imprecision in the POD location, imprecision in the WMA boundaries, or rights attached with features, such as a reservoir, which crosses state boundaries. To include these records, we decided for any POD which was within one kilometer of the state's edge would be assigned to the nearest WMA. Other Changes WestDAAT has Allowed In addition to a more nuanced and consistent method of assigning water right's data to WMAs, there are other benefits gained from using the WestDAAT dataset. Among those is a consistent categorization of a water right's legal status. In HarDWR v1.0, legal status was effectively ignored, which led to many valid concerns about the quality of the database related to the amounts of water the rights allowed to be claimed. The main issue was that rights with legal status' such as "application withdrawn", "non-active", or "cancelled" were included within HarDWR v1.0. These, and other water rights status' which were deemed to not be in use have been removed from this version of the database. Another major change has been the addition of the "unspecified water source category. This is water that can come from either surface water or groundwater, or the source of which is unknown. The addition of this source category brings the total number of categories to three. Due to reviewer feedback, we decided to add the acre-foot (AF) column so that the data may be more applicable to a wider audience. We added the ownerClassification column so that the data may be more applicable to a wider audience. File Descriptions The dataset is a series of various files organized by state sub-directories. In addition, each file begins with the state's name, in case the file is separate from its sub-directory for some reason. After the state name is the text which describes the contents of the file. Here is each file described in detail. Note that st is a placeholder for the state's name. stFullRecords_HarmonizedRights.csv: A file of the complete water records for each state. The column headers for each of this type of file are: state - The name of the state to which the allocations belong to. FIPS - The two digit numeric state ID code. siteID - The site location ID for POD locations. A site may have multiple allocations, which are the actual amount of water which can be drawn. In a simplified hypothetical, a farm stead may have an allocation for "irrigation" and an allocation for "domestic" water use, but the water is drawn from the same pumping equipment. It should be noted that many of the site ID appear to have been added by WaDE, and therefore may not be recognized by a given state's water rights database. allocationID - The allocation ID for the water right. For most states this is the water right ID, and what is recommended to use should a right be looked up on a given state's water rights database. The water amounts associated with these IDs tend to be finer scaled than those associated with siteID. It should be noted that some allocations may be extracted from multiple sites, particularly for larger Places of Use. ownerClassification - A classification of the types of owners for water rights. The most common is `Private` which incorporates a wide range of entities. Several classifications would be grouped into a government category, most of which are for the U.S. Federal Government. These allocations could be listed as "Federal", "United States of America", or as the names of any number of federal agencies. The last major grouping of entities is for "Native American"s. priorityDate - The date we use as the water right priority date for our modeling analysis. This is the legal priority date when it is available. However, for some rights, specifically from California and New Mexico, we used a pseudo priority date (e.g. well completion date or start of well drilling date) when a legal priority date was not available. The most questionable dates come from New Mexico, where the only date associated with certain water right records was the date the allocation was recorded in the database. As the allocation record creation tended to be within a few months of the filing of the application of the water right, from manually double checking the water rights, and our analysis focuses on aggregating water rights on the timescale of years, we determined it was acceptable to use such dates to include as many records as possible. primaryBeneficialUse - From the numerous state water use categories, WaDE categorized them into 21 categories WestDAAT. This column is the original WaDE category for the primary water use at the PoD site. allocationBeneficialUse - From the numerous state water use categories, WaDE categorized them into 21 categories for WestDAAT. This column is the original WaDE category

Economics↗

TU-AB-303-08: GPU-Based Software Platform for Efficient Image-Guided Adaptive Radiation Therapy

Purpose: In this study, we develop an integrated software platform for adaptive radiation therapy (ART) that combines fast and accurate image registration, segmentation, and dose computation/accumulation methods. Methods: The proposed system consists of three key components; 1) deformable image registration (DIR), 2) automatic segmentation, and 3) dose computation/accumulation. The computationally intensive modules including DIR and dose computation have been implemented on a graphics processing unit (GPU). All required patient-specific data including the planning CT (pCT) with contours, daily cone-beam CTs, and treatment plan are automatically queried and retrieved from their own databases. To improve the accuracy of DIR between pCT and CBCTs, we use the double force demons DIR algorithm in combination with iterative CBCT intensity correction by local intensity histogram matching. Segmentation of daily CBCT is then obtained by propagating contours from the pCT. Daily dose delivered to the patient is computed on the registered pCT by a GPU-accelerated superposition/convolution algorithm. Finally, computed daily doses are accumulated to show the total delivered dose to date. Results: Since the accuracy of DIR critically affects the quality of the other processes, we first evaluated our DIR method on eight head-and-neck cancer cases and compared its performance. Normalized mutual-information (NMI) and normalized cross-correlation (NCC) computed as similarity measures, and our method produced overall NMI of 0.663 and NCC of 0.987, outperforming conventional methods by 3.8% and 1.9%, respectively. Experimental results show that our registration method is more consistent and roust than existing algorithms, and also computationally efficient. Computation time at each fraction took around one minute (30–50 seconds for registration and 15–25 seconds for dose computation). Conclusion: We developed an integrated GPU-accelerated software platform that enables accurate and efficient DIR, auto-segmentation, and dose computation, thus supporting an efficient ART workflow. This work was supported by NIH/NCI under grant R42CA137886.

60 APPLIED LIFE SCIENCES↗

Offline multiple adaptive planning strategy for concurrent irradiation of the prostate and pelvic lymph nodes

Purpose: Concurrent irradiation of the prostate and pelvic lymph nodes (PLNs) can be challenging due to the independent motion of the two target volumes. To address this challenge, the authors have proposed a strategy referred to as Multiple Adaptive Planning (MAP). To minimize the number of MAP plans, the authors’ previous work only considered the prostate motion in one major direction. After analyzing the pattern of the prostate motion, the authors investigated a practical number of intensity-modulated radiotherapy (IMRT) plans needed to accommodate the prostate motion in two major directions simultaneously. Methods: Six patients, who received concurrent irradiation of the prostate and PLNs, were selected for this study. Nine MAP-IMRT plans were created for each patient with nine prostate contours that represented the prostate at nine locations with respect to the PLNs, including the original prostate contour and eight contours shifted either 5 mm in a single anterior-posterior (A-P), or superior-inferior (S-I) direction, or 5 mm in both A-P and S-I directions simultaneously. From archived megavoltage cone beam CT (MV-CBCT) and a dual imaging registration, 17 MV-CBCTs from 33 available MV-CBCT from these patients showed large prostate displacements (>3 mm in any direction) with respect to the pelvic bones. For each of these 17 fractions, one of nine MAP-IMRT plans was retrospectively selected and applied to the MV-CBCT for dose calculation. For comparison, a simulated isocenter-shifting plan and a reoptimized plan were also created for each of these 17 fractions. The doses to 95% (D95) of the prostate and PLNs, and the doses to 5% (D5) of the rectum and bladder were calculated and analyzed. Results: For the prostate, D95 > 97% of the prescription dose was observed in 16, 16, and 17 of 17 fractions for the MAP, isocenter-shifted, and reoptimized plans, respectively. For PLNs, D95 > 97% of the prescription doses was observed in 10, 3, and 17 of 17 fractions for the three types of verification plans, respectively. The D5 (mean ± SD) of the rectum was 45.78 ± 5.75, 45.44 ± 4.64, and 44.64 ± 2.71 Gy, and the D5 (mean ± SD) of the bladder was 45.18 ± 2.70, 46.91 ± 3.04, and 45.67 ± 3.61 Gy for three types of verification plans, respectively. Conclusions: The MAP strategy with nine IMRT plans to accommodate the prostate motions in two major directions achieved good dose coverage to the prostate and PLNs. The MAP approach can be immediately used in clinical practice without requiring extra hardware and software.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-time verification of multileaf collimator-driven radiotherapy using a novel optical attenuation-based fluence monitor

Purpose: Multileaf collimator (MLC)-driven conformal radiotherapy modalities [e.g., such as intensity-modulated radiotherapy (IMRT), intensity-modulated arc therapy, and stereotactic body radiotherapy] are more subject to delivery errors and dose calculation inaccuracies than standard modalities. Fluence monitoring during treatment delivery could reduce such errors by allowing an independent interface to quantify and assess measured difference between the delivered and planned treatment administration. We developed an optical attenuation-based detector to monitor fluence for the on-line quality control of radiotherapy delivery. The purpose of the current study was to develop the theoretical background of the invention and to evaluate the detector's performance both statistically and in clinical situations. Methods: We aligned 60 27-cm scintillating fibers coupled to a photodetector via clear optical fibers in the direction of motion of each of the 60 leaf pairs of a 120 leaves Millenium MLC on a Varian Clinac iX. We developed a theoretical model to predict the intensity of light collected on each side of the scintillating fibers when placed under radiation fields of varying sizes, intensities, and positions. The model showed that both the central position of the radiation field on the fiber (x{sub c}) and the integral fluence passing through the fiber ({Phi}{sub int}) could be assessed independently in a single measurement. We evaluated the performance of the prototype by (1) measuring the intrinsic variation of the measured values of x{sub c} and {Phi}{sub int}, (2) measuring the impact on the measured values of x{sub c} and {Phi}{sub int} of random leaf positioning errors introduced into IMRT fields, and (3) comparing the predicted values of x{sub c} and {Phi}{sub int} calculated with the treatment planning software to the measured values of x{sub c} and {Phi}{sub int} in order to assess the predictive effectiveness of the developed theoretical model. Results: We observed a very low intrinsic dispersion, dominated by Poisson statistics, for both x{sub c} (standard deviations of less than 1 mm) and {Phi}{sub int} (standard deviations of less than 0.20%). When confronted with random leaf positioning errors from IMRT segments, {Phi}{sub int} was highly sensitive to single leaf positioning errors as small as 1 mm at isocenter, while x{sub c} was sensitive to leaf pair translation errors of at least 2 mm at isocenter. Owing to the uncertainties in the doses calculated in regions of high perpendicular dose gradients, the measured values of x{sub c} and {Phi}{sub int} deviated from the predicted values of x{sub c} and {Phi}{sub int} by a mean of 1.3 mm and 2.6%, respectively. Conclusion: Our study showed that an optical attenuation-based detector can be used to effectively monitor integral fluence during radiotherapy delivery. The performance of such a system would enable real-time quality control of the incident fluence in current MLC-driven treatments such as IMRT and future adaptive radiotherapy procedures where new treatment plans will have to be delivered without passing thru the current standard quality control chain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗