Search NASA⌕ Search

SEARCH · Search NASA

Results for “Air Pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Investigating the Performance of SF6 Replacement Gases to Enable the Next Generation of Pulsed Power

High voltage switches are essential components in pulsed power systems, where consistent and reliable performance is crucial—particularly as the field explores alternatives to SF 6 as an insulating gas. This project examines the self-break voltage distributions of various gases, with a focus on the low-voltage discharges observed in the lower tail of these distributions. Experimental results revealed that the specific housing design influenced the self-break behavior. Among the tested gases, air demonstrated a more favorable overall distribution compared to SF 6 , albeit requiring higher operating pressures. However, air also exhibited a greater likelihood of extremely low-voltage dropouts, raising concerns about its suitability as a direct replacement for SF 6 . Notably, all gases tested showed a higher-than-expected probability of low-voltage events when considering the tail of the distribution rather than the bulk behavior.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

GreenSight WxHive Unmanned Aerial System (UAS) Atmospheric Profiling at the SGP Central Facility

The GreenSight WxHive is capable of flying multiple nanodrones simultaneously to provide spatiotemporal atmospheric sampling. During the WH2yMSIE campaign, the WxHive would fly up to 5 nanodrones at once, performing profiling within the planetary boundary layer over the ARM SGP Central Facility site. The measurements provided by the WxHive include latitude, longitude, altitude, pressure, temperature, humidity, and wind speed and direction. See the attached WeatherHive User Guide for more details about the instrument and measurements.

Air pressure↗

Benchmark Simulation of the Natural Convection Shutdown Heat Removal Test Facility Using SAM

Natural convection systems are a promising method to passively remove heat from reactor cavities during loss of forced flow accident scenarios. In this work at Argonne National Laboratory (ANL), a highly instrumented Natural Convection Shutdown Heat Removal Test Facility (NSTF) was used to demonstrate the effectiveness of air-cooled natural convection systems. In previous work, RELAP5-3D simulations were performed on this facility with favorable comparisons to experiment for mass flow rate, pressure drop, air temperature increase, and air velocity. Both experimental and simulation efforts with this facility present a useful opportunity to perform a benchmark study with the System Analysis Module (SAM). SAM is an advanced thermal-hydraulic system code currently in development at ANL for advanced non-light water reactor safety analysis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experimental study and demonstration of pilot-scale, dry feed, oxy-coal combustion under pressure

In this paper, we discuss how pressurized oxy-combustion is a promising technology for low-carbon, fossil fuel utilization. It has the potential of improved efficiency and economics compared with conventional atmospheric pressure oxy-combustion. Washington University in St. Louis has proposed a new pressurized oxy-combustion process, namely Staged Pressurized Oxy-Combustion, which has the potential to improve further the plant efficiency, operational flexibility, and economics. This process burns pulverized coal in a pressurized, oxy-combustion environment, which has not been demonstrated in a pilot-scale system before. To address this gap, a 100 kWth pressurized oxy-combustion facility was designed and constructed. This facility has a unique burner and furnace design featuring a co-axial, low-mixing flow field, which is drastically different from conventional coal-fired boiler designs where strong mixing is sought by introducing swirl or recirculating flows. This work aims to present the first pilot-scale experimental results of a dry-feed, pressurized oxy-combustion system. The tests focused on exploring flame stability and shape, char burnout, and fine particulate matter formation. Testing results suggest that the burner has excellent flame stability. The flame shape is consistent with the design philosophy and agrees with large eddy simulations. Importantly, complete char combustion can be achieved with an oxygen mole fraction in the flue gas of only 0.8%, as opposed to a required value of ~3% for conventional atmospheric pressure air-fired or oxyfuel combustion, which reduces the costs of both oxygen generation upstream and oxygen removal downstream. The testing results show promise for dry-feed, pressurized oxy-combustion, and the new burner and furnace design.

01 COAL, LIGNITE, AND PEAT↗

Modelling the development of capillary pressure in freshly 3D-printed concrete elements

3D concrete printing is a promising technology recently developed to automate construction. Since no formwork is used in this technology to support and protect fresh concrete, there are two aspects which considerably accelerate the development of capillary pressure in 3D-printed concrete in comparison to conventionally placed concrete: i) high stiffness of 3D-printed needed to provide sufficient buildability, and ii) very early and fast evaporation of pore water. Accelerated development of capillary pressure may lead to severe plastic shrinkage cracking in 3D-printed elements and, hence, need to be mitigated. This investigation aims at providing a poromechanical model for capillary pressure development in 3D-printed elements. To simulate the development of capillary pressure and plastic shrinkage, environmental factors, material properties, and element geometry need to be considered as a whole. The model inputs – coefficient of permeability, static bulk modulus, air entry pressure and chemical shrinkage rate – were determined experimentally. The model was validated for two fine-grained concretes. Both 3D-printed materials yielded faster capillary pressure increase in comparison to cast concrete, while partial substitution of cement with silica fume further accelerated the capillary pressure development. Furthermore, due to the lower permeability of the mixture containing silica fume, the gradient of capillary pressure between 3D-printed layers increased, as did the gradient of plastic shrinkage.

36 MATERIALS SCIENCE↗

LIQUID AIR COMBINED CYCLE

Hybrid integration of thermal energy storage with gas turbines can provide compact, cost-effective, long-duration energy storage while reducing the fuel consumption of dispatchable resources needed for the reliability of renewable dominant electric grids. The Liquid Air Combined Cycle™ (LACC) is a hybrid energy storage system using cryogenic liquid air as an energy storage medium and gas turbine exhaust heat to extract stored energy. The storage tank is charged using liquefaction processes employing electric motor-driven compressors to pressurize the air, heat exchangers to reject heat of compression, and expanders to reduce the temperature and liquefy the air. Proven cryogenic refrigeration processes can be selected based on capital cost (per kg/s of liquid air produced), efficiency (kJ per kg of air produced), and operating factors including startup speed and load following capability. This paper presents results of studies undertaken for the U.S. Department of Energy to evaluate cost and performance tradeoffs for charge and discharge cycle components, optimize charge and discharge cycles, and assess the techno-economic potential of LACC technology.

Conlon, William↗

Analysis of the Ion Conversion Mechanisms in the Effluent of Atmospheric Pressure Plasma Jets in Ar with Admixtures of O 2 , H 2 O and Air

Ionic species in atmospheric pressure plasma jets (APPJs) play an important role in plasmasurface and plasma-liquid interactions, nonetheless, they have not received the same attention as their neutral reactive species counterparts. In this work, a molecular beam mass spectrometer (MBMS) was used to characterize the ion compositions in the effluent of an APPJ operating in ambient air for different feed gases including Ar + O 2 , Ar + air and Ar + H 2 O mixtures inspired by gas compositions used for biomedical applications. Changes in compositions of positive and negative ions as a function of nozzle-to-substrate distance along the plasma plume were analyzed and compared with a pseudo-1D plug flow model. Positive and negative ions were detected up to distances of 12 mm from the visible plasma plume tip. The measurements enable to follow the ion conversion pathways in the effluent of the APPJs as a function of distance from the nozzle. The trends in ion yield obtained from a pseudo-1D plug flow model showed generally a good agreement with the experimentally observed trends after addition of ionic reactions to the previously reported reaction set but also some distinctive differences were observed. The dominant positive ions in the far effluent are water ion clusters, the most stable ion for all gas mixtures investigated, while a large variety of negative ions was found for different gas mixtures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Novel geometries for air-cooled condensation of ammonia-water mixtures

An analytical and experimental investigation of air-cooled condensers for small-scale ammonia-water absorption heat pumps is presented. Conventional round-tube corrugated fin design and a novel multi-pass tube array design are considered for a condenser operating at severe ambient conditions within a compact footprint. Segmental heat and mass transfer models are developed to gain a deeper understanding of the characteristics of each design. Predicted heat duties are within 5% of the measured values. The limitations of correlations to predict air-side pressure drop in corrugated fins are identified. The performance of the novel multi-pass tube array condenser was comparable to that of conventional condensers, but is determined to be air-side limited throughout length of the heat exchanger. An improved multi-pass condenser design with fins for increased air-side area is proposed using the insights gained from the modeling and experiments. In closing this design meets the heat duty requirements at severe ambient conditions, while decreasing the size of the heat exchanger by 33%.

42 ENGINEERING↗

Effect of Evaporation on Vapor Space Flammability in DWPF Process Vessels - 20278

The Savannah River Site (SRS) Defense Waste Processing Facility (DWPF) processes liquid high-level waste (HLW) and encapsulates it in glass within stainless-steel containers suitable for safe, long-term storage and disposal. Radiolytic and chemical decomposition of the liquid waste generates hydrogen and other flammable gases creating a hazard. The rate of flammable gas generation increases by an order of magnitude as temperature increases from sub-boiling to boiling. DWPF controls this hazard in process tanks by ensuring a minimum purge flow through each tank's head space. The minimum purge flow rate is established assuming dry air and neglecting evaporation. However, this study determined that steam from boiling in a representative process tank is sufficient to dilute flammable gases and, thereby, preclude flammability. For sub-boiling, water vapor is an insufficient diluent considering hydrogen's lower flammable limit (LFL) in air. However, the upper and lower flammable limits approach each other in a hydrogen-air-water-vapor environment as the water vapor concentration increases. This effect may preclude flammable conditions if water vapor concentration is about 60 volume percent or higher. A saturated, constant-pressure air-water system would achieve 60 volume percent water vapor at 86 deg. C. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A low power flexible dielectric barrier discharge disinfects surfaces and improves the action of hydrogen peroxide

There is an urgent need for disinfection and sterilization devices accessible to the public that can be fulfilled by innovative strategies for using cold atmospheric pressure plasmas. Here, we demonstrate a successful novel combination of a flexible printed circuit design of a dielectric barrier discharge (flex-DBD) with an environmentally safe chemical reagent for surface decontamination from bacterial contaminants. Flex-DBD operates in ambient air, atmospheric pressure, and room temperature without any additional gas flow at a power density not exceeding 0.5 W/cm 2 . The flex-DBD activation of a 3% hydrogen peroxide solution results in the reduction in the bacterial load of a surface contaminant of > 6log 10 in 90 s, about 3log 10 and 2log 10 better than hydrogen peroxide alone or the flex-DBD alone, respectively, for the same treatment time. We propose that the synergy between plasma and hydrogen peroxide is based on the combined action of plasma-generated OH · radicals in the hydrogen peroxide solution and the reactive nitrogen species supplied by the plasma effluent. A scavenger method verified a significant increase in OH · concentration due to plasma treatment. Novel in-situ FTIR absorption spectra show the presence of O 3 , NO 2 , N 2 O, and other nitrogen species. Ozone dissolving in the H 2 O 2 solution can effectively generate OH · through a peroxone process. The addition of the reactive nitrogen species increases the disinfection efficiency of the hydroxyl radicals and other oxygen species. Hence, plasma activation of a low concentration hydrogen peroxide solution, using a hand-held flexible DBD device results in a dramatic improvement in disinfection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Drizzle, Turbulence, and Density Currents Below Post Cold Frontal Open Cellular Marine Stratocumulus Clouds

Nine cases of postcold frontal marine stratocumulus clouds exhibiting open cellular mesoscale organization are analyzed to characterize the drizzle, turbulence, and density currents below them. Data collected by the vertically pointing Doppler cloud radar and multiple lidars part of the Atmospheric Radiation Measurement (ARM) Eastern North Atlantic (ENA) site are used in these analyses. A total of 251 drizzle shafts passed over the site with 76 shafts sampled for more than 15 min by the vertically pointing instruments. On average the drizzle shafts were ~18 km wide with below-cloud drizzle water path of ~40 g m −2 , cloud base rain rate of 7.78 mm day −1 , and cloud base drizzle modal diameter of 393 μm. The widths of the drizzle shafts did not exhibit any relationship with the cloud base rain rate, below-cloud drizzle water path, and the total water removed from the cloud. The downdrafts in the lowest 500 m within the drizzle cells strengthened with increasing cloud base rain rates, while the updrafts within drizzle cells did not exhibit this behavior. On average, the surface air density, pressure, water vapor mixing ratio, and wind speed along the background wind during the drizzle shaft were higher by 1.88 g m −3 , 8.60 Pa, 0.24 g kg −1 , and 1.22 m s −1 , respectively, from their background values. On the other hand, the surface air temperature was lower by 0.43 K during the drizzle shaft than its background value. The coincident measurements highlight the drizzle-turbulence-surface coupling in these cloud systems.

59 BASIC BIOLOGICAL SCIENCES↗

Temporal Study 2021-2022: Sensor-Based Time Series of Surface Water Temperature, Specific Conductance, Total Dissolved Solids, Turbidity, pH, and Dissolved Oxygen from across Multiple Watersheds in the Yakima River Basin in Washington, USA (v2)

This dataset supports a broader study examining the drivers of temporal variability in sediment respiration rates in the Yakima River Basin. The dataset provides periodic (weekly or biweekly) in situ hydrological and water chemistry sensor data, handheld sensor water chemistry data, general environmental context photos, and field metadata collected at six sites within multiple rivers in the Yakima River Basin in Washington, USA. In addition to the sensor data, there are plots of continuous in situ sensor data and R scripts used to generate the plots. Related sample-based water chemistry data are published separately at https://data.ess-dive.lbl.gov/datasets/doi:10.15485/1898912.The data package was originally published in September 2022. It was updated in June 2025 (v2; modified files). See the change history section in the readme for more details. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. This dataset is comprised of one main data folder containing two sensor-specific subfolders, and one photographs folder. The main data folder includes file-level metadata (flmd), data dictionary (dd), installation methods, field metadata, handheld sensor data, field data collection protocols, international generic sample number (IGSN) mapping file, and a readme file. Each sensor subfolder (BarotrollAtm and MantaRiverData) contains a subfolder containing sensor timeseries data and plots. The BarotrollAtm Data subfolder contains In Situ Rugged BaroTROLL sensor pressure and air temperature data. The MantaRiverData subfolder contains Eureka Manta+ 35B multisonde temperature, specific conductance, and turbidity. The FieldPhotos folder contains environmental context photographs and videos. All files are .csv, .pdf, .R, .jpg, .jpeg, .heic, .mov, or .mp4.

54 ENVIRONMENTAL SCIENCES↗

Temporal Study 2022-2024: Sensor-Based Time Series of Surface Water Temperature, Specific Conductance, Total Dissolved Solids, Turbidity, Chlorophyll A, and Dissolved Oxygen from across Multiple Watersheds in the Yakima River Basin in Washington, USA

This dataset supports a broader study examining the drivers of temporal variability in sediment respiration rates in the Yakima River Basin. The dataset provides periodic (bi-weekly or monthly) in situ hydrological and water chemistry sensor data, handheld sensor water chemistry data, general environmental context photos, and field metadata collected at six sites across the Yakima River Basin in Washington, USA. Sample and sensor data from previous years (2021-2022) can be found at https://data.ess-dive.lbl.gov/datasets/doi:10.15485/1898912 and https://data.ess-dive.lbl.gov/datasets/doi:10.15485/1892054, respectively. Related sample data from 2022-2024 are available at https://data.ess-dive.lbl.gov/datasets/doi:10.15485/2562910. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. In addition to a readme, this data package also includes a file-level metadata (FLMD) file that describes each file and a data dictionary (DD) that describes all column/row headers and variable definitions This dataset contains a folder of environmental context photographs and videos and (1) file-level metadata; (2) data dictionary; (3) readme; (4) field metadata; (5) field protocols; (6) international generic sample number (IGSN) mapping file; (7) handheld sensor data; and (8) two sensor subfolders. Each sensor subfolder (BarotrollAtm and MantaRiverData) contains a subfolder containing sensor time series data and plots. The BarotrollAtm Data subfolder contains In Situ Rugged BaroTROLL sensor pressure and air temperature data. The MantaRiverData subfolder contains Eureka Manta+ 35B multisonde temperature, specific conductance, and chlorophyll A. All files are .csv, .pdf, .jpg, .jpeg, .mp4, .png, or .mov.

54 ENVIRONMENTAL SCIENCES↗

Defining a compact dry cooler design to reduce LCOE contribution in a CSP facility

Concentrating solar power (CSP), when coupled with a supercritical carbon dioxide (sCO 2 ) power cycle and sensible heat storage, presents a renewable and clean alternative for utility-scale power generation. However, in order to be competitive in the current and future markets, CSP facilities must limit their levelized cost of electricity (LCOE) by minimizing capital costs and reducing operating costs over the lifetime of the plant. Targeting this goal, this study investigates the LCOE impact of the power cycle pre-cooler. This study considers a compact dry cooler with micro-channel technology on the CO 2 side and formed fin geometry on the air side, using directly-coupled centrifugal fans and a transition duct to improve air distribution across the fins as well as protect the fins from contaminants which may cause blockage, soiling, fouling, and damage. In an effort to better understand the dry cooler impact on LCOE, a sensitivity study was conducted using various combinations of end-to-end approach temperatures, air-side pressure drop values, CO 2 -side pressure drop values, fan types, cooler turndown control schemes, cooler module sizes, and design-point ambient temperatures. Furthemore, off-design cycle performance data was calculated for each dry cooler design using NPSS simulation software; cycle performance data were then input to System Advisor Model (SAM) along with the associated capital costs for LCOE prediction of a 100 MW system over a 30 year plant lifetime. Results of this study show the LCOE is most sensitive to air-side performance, followed by heat transfer effectiveness and capital cost. It was found that a power cycle with a mid- to high-performance dry cooler will produce the most competitive power-production costs. Designing at the extreme ends for approach temperature (or effectiveness), design-point ambient temperature, and compactness (footprint) produce higher LCOE values; mid-range values for these parameters balance performance, operating costs, and associated capital cost to optimize LCOE.

14 SOLAR ENERGY↗

Using non-invasive MEMS pressure sensors for measuring building envelope air leakage

Micro-electromechanical systems (MEMS)-based sensors have seen significant improvements in accuracy and cost over the past several years, and due to the need for altitude sensing in unmanned aerial vehicles and wearable technologies, absolute pressure sensors have shown the most dramatic improvements. This paper investigates applications of MEMS sensors in commercial buildings, including pairing two absolute pressure sensors to determine differential pressures between different locations in and around buildings. Differential pressure measurements are commonly made in commercial buildings for a number of applications, including static pressure measurements for variable-speed supply fan control, air balancing in hospitals, and for envelope and duct air leakage testing. This paper focuses specifically on envelope air-leakage testing applications of these sensors. The use of continuous pressure measurements in addition to one-time non-intrusive outdoor airflow measurements of rooftop packaged units is investigated. A comparison with standardized leakage testing indicated that continuous measurements with MEMS pressure-sensors were able to estimate envelope leakage to within 3–16% of the standardized test result. In addition, the magnitude and stability of differential pressure differences that can be resolved with absolute pressure sensors are also investigated in the laboratory and the field. Results show that the sensors can be effectively used for pressures seen in low rise buildings with rooftop units.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of thermal radiation of a gas-particulate-cloud in a pressurized oxy-coal combustor

Pressurized oxy-combustion (POC) aims to reduce carbon emissions from coal-fired power plants. In the POC process, pulverized coal is burned at elevated pressure in an O2-CO2 environment. The elevated pressure and high CO2 and H2O concentrations strongly impact thermal radiation, thereby significantly distinguishing POC system from conventional atmospheric-pressure air-fired and oxy-fuel combustion. Consequently, a thorough understanding of thermal radiation in POC is required to promote the development of novel combustors. The present computational work analyzes thermal radiation of the gaseous and particle phases in the pilot-scale POC combustor in Washington University in St. Louis. Particularly, the radiation characteristics of the gaseous and particulate cloud were estimated by employing the statistical narrow band model and the large-particle model. It is found that thermal radiation of a particulate cloud dominates in the combustor under the conditions of a furnace temperature of 1500 K and no substantial particle loss. Another important result is that the gas-and-particulate cloud can be approximately treated as a graybody under the same conditions. To be more specific, the results of spectral radiation intensity of a gas comprised of 40% (vol) H2O and 60% CO2 show that when the pressure is increased to 15 bar, and the radiation pathlength to 100 cm, the spectral radiation profile of the gas phase approaches that of a blackbody at the respective temperature. In addition, the emissivity of the particulate cloud has been evaluated as a function of the particle concentration and diameter by means of the large particle model. It is shown that the emissivity grows with the particle concentration but decreases with the particle size for the same mass of a particulate cloud. The emissivity of a particulate cloud in oxy- combustion exceeds that in air-fired combustion. This work could be used to validate the assumption of the gray gas model adopted in numerical simulations.

Li, Lei↗

Data and scripts associated with the manuscript evaluating the hydrologic responses of the Pacific Northwest watersheds to wildfires (v2)

This data package is associated with the publication “Evaluating Post-fire Watershed Response to Varying Burn Severity and Precipitation Regimes Using Fully-distributed and Integrated Hydrologic Models” submitted to Journal of Hydrology (Li et al. 2025). In this study, we employed the Advanced Terrestrial Simulator (ATS), an integrated watershed model that couples surface flow, subsurface flow, and canopy biophysical processes, to investigate post-fire hydrologic responses in a few selected watersheds with varying burn severity.The data package contains the required input data (meteorological forcing, Leaf Area Index, wildfire burn severities, etc.) to run the model, configuration files, the Jupyter notebooks in Python to pre-process and post-process data, the figures in the manuscript, and the modeling output files. The variables include watershed-averaged evapotranspiration, watershed-averaged surface/subsurface/canopy water content, and river discharge at watershed outlet.The data package contains a file-level metadata that lists and describes all the files contained in the data package (ATS_flmd.csv), a data dictionary file that defines columns headers across all csv files contained in the data package (ATS_dd.csv), a data package level readme file (the current file), and four zipped folders.The ‘data’ folder provides data needed to run the model in .h5, .i2s, .xyz, .shp, and .exo formats. The sub-folders are for each data types. The ‘model’ folder provides input files (.xml format) and essential model outputs. Each sub-folder provides the files from each simulated watershed. The ‘notebooks’ folder provides the Jupyter notebooks (.ipynb format) for pre- and post- processing model files, and for producing the figures in the manuscript. The ‘figures’ folder provides the figures associated with manuscript in .pdf and .png formats.The ‘model’ folder and the ‘data’ folder have been split into 5GB-large pieces using the Linux command ‘split -b 5120m model.zip model.zip.’ and ‘split -b 5120m data.zip data.zip.’, respectively. They can be merged back using the Linux command ‘cat model.zip.* > model.zip’ and ‘cat data.zip.* > data.zip’, respectively.

54 ENVIRONMENTAL SCIENCES↗

A Review of Modeling Approaches for Predicting Frost Growth and Defrosting on Tube-Fin Heat Exchangers: Preprint

Frost formation and growth on the evaporator surface is a common process that deteriorates the air-refrigerant heat transfer and restricts airflow. This degrades the performance of the vapor compression system by increasing temperature lift and air-side pressure drop. To accurately predict these effects during coil frosting, as well as the energy use and duration of the defrost process, there is a need to estimate the heat and mass transfer, momentum transport, and solid-liquid and liquid-vapor phase change. Therefore, in the past few decades, continuous effort has been made to model frosting and defrosting processes using approaches ranging from empirical correlations to computational fluid dynamic models. To provide a clearer overview for researchers, engineers, and manufacturers in this field, this paper provides a comprehensive literature review for frosting and defrosting models. The paper begins with theoretical background of frost formation and defrost processes, and then reviews the common modeling approaches in literature and their underlying assumptions when trying to account for various physical phenomenon. Based on the literature review, the most critical modeling effort for frost formation is the determination of frost densification rate and frost growth rate. Various methods to predict these two parameters are reviewed. Empirical correlations commonly used for frost density and thermal conductivity are presented and compared. For the defrost process, various multi-stage models have been proposed with different assumptions. Some assume the presence of air gap between the tube wall and the frost, while others consider the melted frost flow due to gravity. We also review physics-based and empirical approaches to integrate defrost models into heat pump models. We conclude by identifying research gaps and providing recommendations.

defrost↗