Search NASA⌕ Search

SEARCH · Search NASA

Results for “Analytical detection method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

An Automated Ultraclean Ion Exchange Separation Method for the Determinations of 232Th and 238U in Copper using Inductively Coupled Plasma Mass Spectrometry

This work presents a novel automated analytical method developed for high throughput ultrasensitive determinations of Th and U in copper using inductively coupled plasma mass spectrometry (ICP-MS). The method is based on the use of ultra clean sample preparation procedures including the use of a fully automated off-line chromatography system for the extraction and pre-concentration of the analytes prior to ICP-MS analysis. The separation system is equipped with a single reusable chromatographic column that, with the rigorously clean procedures developed herein, provided a low carryover, low background, and reproducible automated separation method. Isotope dilution methods were used for quantitation. Method Detection Limits (MDLs) of 3.7 and 9.4 fg·g-1 were obtained for the quantitation of 232Th and 238U in copper, respectively, corresponding to activities of 0.0148 and 0.116 microBq·kg-1 for 232Th and 238U, respectively. The analytical method provided high and reproducible tracer recoveries. The use of an automated system significantly reduced the extremely tedious active work time required for the chemist (by ca. 80%) relative to manually performing the separation. This method could be adapted to other critical sample matrices requiring the utmost in high throughput clean chemistry procedures for automated ultrasensitive analyses.

Arnquist, Isaac J.↗

Parsing Weather Variability and Wildfire Effects on the Post-Fire Changes in Daily Stream Flows: A Quantile-Based Statistical Approach and Its Application

Determining wildland fire impacts on streamflow can be problematic as the hydrology in burned watersheds is influenced by post-fire weather conditions. Here, this study presents a quantile-based analytical framework for assessing fire impacts on low and peak daily flow magnitudes, while accounting for post-fire weather influences. This framework entails (a) the bootstrap method to compute the relative change in the post-fire annual flow and weather statistics, (b) double mass analysis to detect if post-fire baseflow and quick-flow yield ratios are significantly altered, and (c) a quantile regression method to parse fire effects on flow at a specific quantile. We illustrate the applicability of this analytical framework using 44 western US streams with at least 5% of their watershed area burned. Results indicate that large, high-severity burns in upland watersheds can raise the streamflow magnitude at the 0. 05 th and 0. 95 th quantiles for at least the five post-fire years. Quantile regression results show that the median fire-related increase in flow for the five post-fire years can be up to 5,000% (Standard Error; S.E. < 2%) at the 0. 05 th E quantile and 161% (S.E. < 10%) at the 0. 95 th quantile. The fire-related increase in flow was often pronounced at the 0. 05 th quantile for streams in the Pacific Northwest and California regions. The difference in fire effects on flow (at both quantiles) across streams was related to post-fire weather, pyrology, physiography, and land cover. The proposed analytical framework can be useful for detecting and quantifying fire effects on the low and peak stream flows in burned watersheds without overlapping disturbances.

54 ENVIRONMENTAL SCIENCES↗

Real-Time Screening for Uranium Enrichment by Paper Spray Ionization Mass Spectrometry for Field Applications

A rapid isotope ratio screening technique for uranium enrichment is demonstrated by utilizing paper spray ionization (PSI) high-resolution mass spectrometry (HRMS). Measurements were conducted using an ambient ionization mass spectrometer coupled to a custom-made JEOL PSI attachment apparatus, with de minimus sample preparation requirements. The current method detection limit for individual isotopes (e.g., 235 U and 238 U) is approximately 50 pg, with subsequent optimization expected to further improve U isotopic sensitivity. The PSI analytical method described herein can support rapid analysis (both in-field and in-lab screening) of isotopes-of-interest, as demonstrated by empirical differentiation of depleted uranium (DU) and low enriched uranium (LEU) analytical aliquots. Furthermore, this analytical workflow holds promise for applications in nuclear forensics, international nuclear safeguards, and nonproliferation missions.

Anions↗

Use of Boundary Layer Transition Detection to Validate Full-Scale Flight Performance Predictions

Full-scale flight performance predictions can be made using CFD or a combination of CFD and analytical skin-friction predictions. However, no matter what method is used to obtain full-scale flight performance predictions knowledge of the boundary layer state is critical. The implementation of CFD codes solving the Navier-Stokes equations to obtain these predictions is still a time consuming, expensive process. In addition, to ultimately obtain accurate performance predictions the transition location must be fixed in the CFD model. An example, using the M2.4-7A geometry, of the change in Navier-Stokes solution with changes in transition and in turbulence model will be shown. Oil flow visualization using the M2.4-7A 4.0% scale model in the 14'x22' wind tunnel shows that fixing transition at 10% x/c in the CFD model best captures the flow physics of the wing flow field. A less costly method of obtaining full-scale performance predictions is the use of non-linear Euler codes or linear CFD codes, such as panel methods, combined with analytical skin-friction predictions. Again, knowledge of the boundary layer state is critical to the accurate determination of full-scale flight performance. Boundary layer transition detection has been performed at 0.3 and 0.9 Mach numbers over an extensive Reynolds number range using the 2.2% scale Reference H model in the NTF. A temperature sensitive paint system was used to determine the boundary layer state for these conditions. Data was obtained for three configurations: the baseline, undeflected flaps configuration; the transonic cruise configuration; and, the high-lift configuration. It was determined that at low Reynolds number conditions, in the 8 to 10 million Reynolds number range, the baseline configuration has extensive regions of laminar flow, in fact significantly more than analytical skin-friction methods predict. This configuration is fully turbulent at about 30 million Reynolds number for both 0.3 and 0.9, Mach numbers. Both the transonic cruise and the high-lift configurations were fully turbulent aft of the leading-edge flap hingeline at all Reynolds numbers.

Hamner, Marvine↗

Extreme Molecular Complexity Resulting in a Continuum of Carbonaceous Species in Biomass Burning Tar Balls from Wildfire Smoke

Biomass burning emits a wide range of carbonaceous particles into the atmosphere and has negative impacts on human health and the Earth’s radiative balance. Nonvolatile spherical organic aerosol particles, commonly known as tar balls, represent one of the most abundant particles in aged biomass burning smoke. However, the detailed molecular-level composition of ambient tar balls is largely unknown but critical to access their environmental impacts. Ambient aerosol samples collected during a wildfire event, which were ~90% tar balls by number fraction, were analyzed using ultrahigh resolution Orbitrap Elite mass spectrometry with four complementary ionization modes. Our results show the molecular composition of tar balls to be complex, composed of over 10,000 molecular formulas. Model estimated saturation mass concentrations and relative humidity dependent glass transition temperatures were consistent with low volatility and solid morphology as expected for tar balls. Room-temperature evaporation kinetics showed that these particles were composed of ~90% non-volatile species. The molecular complexity detected here signifies a continuum of carbonaceous species, ranging from C3 to C45 with continuous ranges of oxygenation and hydrogen saturation for each Cn. Approximately 24% of molecular formulas were estimated the be highly aromatic, which could indicate chemical compounds with negative health effects, and which may contribute to visible light absorption. The carbon continuum observed here has significant implications for the molecular characterization of atmospheric organic matter. The level of complexity detected here should not be ignored in future studies and we demonstrate that multiple analytical methods may be required to suitably interpret this complexity on a molecular level.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Application of advanced control techniques to aircraft propulsion systems

Two programs are described which involve the application of advanced control techniques to the design of engine control algorithms. Multivariable control theory is used in the F100 MVCS (multivariable control synthesis) program to design controls which coordinate the control inputs for improved engine performance. A systematic method for handling a complex control design task is given. Methods of analytical redundancy are aimed at increasing the control system reliability. The F100 DIA (detection, isolation, and accommodation) program, which investigates the uses of software to replace or augment hardware redundancy for certain critical engine sensor, is described.

Lehtinen, B.↗

TPSAS-NF1676L-18905-DND

Aircraft loss of control is a leading cause of fatal accidents across all transport airplane and operational classes. Aircraft loss-of-control (LOC) accidents are highly complex in that they can result from numerous causal and contributing factors acting alone or (more often) in combination. Hence, there is no single intervention strategy to prevent these accidents. This presentation will define LOC as a dynamics and control problem, summarize LOC accident analysis results, and discuss current NASA research that supports a holistic approach for significantly reducing aircraft LOC accidents for current and future aircraft. The approach includes onboard systems technologies for LOC prevention and recovery, as well as a parallel effort for their validation. The onboard systems technologies provide improved situational awareness, guidance, and control under realistic LOC hazards, and include: hazards effects detection and mitigation; upset detection, prevention and recovery; and multiple hazards mitigation. Validation technologies include analytical, simulation, and experimental methods, tools and testbeds as well as the development of a comprehensive set of realistic LOC test scenarios. Future research directions will also be discussed.

Christine Belcastro↗

Deep eutectic solvents as green and sustainable diluents in headspace gas chromatography for the determination of trace level genotoxic impurities in pharmaceuticals

Genotoxic impurities (GTIs) are potential carcinogens that need to be controlled down to ppm or lower concentration levels in pharmaceuticals under strict regulations. The static headspace gas chromatography (HS-GC) coupled with electron capture detection (ECD) is an effective approach to monitor halogenated and nitroaromatic genotoxins. Deep eutectic solvents (DESs) possess tunable physico-chemical properties and low vapor pressure for HS-GC methods. In this study, zwitterionic and non-ionic DESs have been used for the first time to develop and validate a sensitive analytical method for the analysis of 24 genotoxins at sub-ppm concentrations. Compared to non-ionic diluents, zwitterionic DESs produced exceptional analytical performance and the betaine: 7 (1,4- butane diol) DES outperformed the betaine: 5 (1,4-butane diol) DES. Limits of detection (LOD) down to the 5-ppb concentration level were achieved in DESs. Wide linear ranges spanning over 5 orders of magnitude (0.005–100 µg g –1 ) were obtained for most analytes with exceptional sensitivities and high precision. The method accuracy and precision were validated using 3 commercially available drug substances and excellent recoveries were obtained. Finally, this study broadens the applicability of HS-GC in the determination of less volatile GTIs by establishing DESs as viable diluent substitutes for organic solvents in routine pharmaceutical analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultra-high SERS detection of consumable coloring agents using plasmonic gold nanostars with high aspect-ratio spikes

Solution-based SERS detection by using a portable Raman instrument has emerged as an important tool due to its simplicity, and flexibility for rapid and on-site screening of analyte molecules. However, this method has several shortcomings, including poor sensitivity especially for weak-affinity analyte molecules, where there is no close contact between the plasmonic metal surface and analyte molecule. Examples of weak-affinity molecules include pigment molecules that are commonly used as a consumable coloring agent, such as allura red (AR), and sunset yellow (SY). As high consumption of colorant agents has been shown to cause adverse effects on human health, there is a strong need to develop a simple and practical sensing system with high sensitivity for these agents. Here we present a novel, highly sensitive solution-based SERS detection method for AR, and SY by using CTAC capped gold nanostars (GNS) having different aspect ratios (GNS-2, GNS-4, and GNS-5) without utilizing any aggregating agents which can enhance SERS signal however it reduces batch to batch reproducibility. The influence of the aspect ratio of GNS on SERS properties was investigated. We have achieved a limit of detection (LOD) of AR and SY as low as 0.5 and 1 ppb, respectively by using GNS-5 with the advantages of minimal sample preparation by just mixing the analyte solution into a well plate containing GNS solution. In addition, excellent colloidal stability and reproducibility have further enhanced the applicability in real-world samples. Altogether, our results evidence that the solution-based SERS detection platform using high aspect-ratio GNS can be applied for practical application to detect pigment molecules in real samples with satisfactory results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis, identification and confirmation of synthetic opioids using chloroformate chemistry: Retrospective detection of fentanyl and acetylfentanyl in urine and plasma samples by EI-GC-MS and HR-LC-MS

Electron Impact Gas Chromatography-Mass Spectrometry (EI-GC-MS) and High Resolution Liquid Chromatography-Mass Spectrometry (HR-LC-MS) have been used in the analysis of products arising from the trichloroethoxycarbonylation of fentanyl and acetylfentanyl in urine and plasma matrices. The method involves the initial extraction of both synthetic opioids separately from the matrices followed by detection of the unique products that arise from their reaction with 2,2,2-trichloroethoxycarbonyl chloride (Troc-Cl), namely Troc-norfentanyl and Troc-noracetylfentanyl. The optimized protocol was successfully evaluated for its efficacy at detecting these species formed from fentanyl and acetylfentanyl when present at low and high levels in urine (fentanyl: 5 and 10 ng/mL and acetylfentanyl: 20 and 100 ng/mL) and plasma (fentanyl: 10 and 20 ng/mL and acetylfentanyl: 50 and 200 ng/mL), values that reflect levels reported in overdose victims. The HR-LC-MS method’s LOQ (limit of quantitation) for the Troc-norfentanyl and Troc-noracetylfentanyl products was determined to be ~10 ng/mL for both species. Even though the superiority in the detection of these species by HR-LC-MS over EI-GC-MS, the latter method proved to be important in the detection of the second product from the reaction, namely 2-phenylethyl chloride that is crucial in the determination of the original opioid. This observation highlights the importance of using complimentary analytical techniques in the analysis of a sample, whether biological or environmental in nature. The method herein serves as a complementary, qualitative confirmation for the presence of a fentanyl in collected urine, plasma and by extension other biological samples amenable to the common extraction procedures described for opioid analysis. More importantly, the method’s main strength comes from its ability to react with unknown fentanyls to yield products that can be not only detected by EI-GC-MS and HR-LC-MS but can then be used to retrospectively identify an unknown fentanyl.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Reservoir Temperature Estimator (RTEst): A multicomponent geothermometry tool

The Reservoir Temperature Estimator (RTEst) is a multicomponent geothermometry tool for estimating reservoir geochemical parameters including reservoir temperature, CO 2 fugacity, mass of water lost or gained, and a reaction factor. It estimates these parameters and their associated uncertainties by minimizing an objective function that is the weighted sum of squares of the saturation indices of a user-selected set of minerals believed to be equilibrated with the reservoir fluid. RTEst accomplishes these estimates by combining the geochemical modeling capabilities of The Geochemist’s Workbench® with the optimization/parameter estimation resources of PEST®. An included interface aids the user in selecting plausible mineral phases to comprise the objective function and calculates their weighting factors. The working principles of RTEst are described and its efficacy is illustrated by presenting results of its application to various geothermal fields with known conditions. These examples show RTEst can account for the alteration of ascending reservoir fluid by mineral (calcite) re-equilibration with changes in temperature, reconstruct waters with CO 2 loss, correct for the deficit of water and other volatiles (CO 2,gas , H 2 S gas ) from boiling, and determine the amount of mixing of thermal and non-thermal waters. RTEst can use data with basis species below detection limit, missing, or unreliable either by assuming equilibrium with a controlling mineral (fixed-analyte method) or by treating the analyte concentration as an optimization parameter. The inverse of variance weighting method included in RTEst provides more representative results than either the normalization or unit weighting methods. Finally, the ability of RTEst to calculate reservoir temperatures, gas fugacity, and mixing fractions demonstrates its usefulness as a tool for evaluating geothermal systems.

15 GEOTHERMAL ENERGY↗

Lidar Tracking of Multiple Fluorescent Tracers: Method and Field Test

Past research and applications have demonstrated the advantages and usefulness of lidar detection of a single fluorescent tracer to track air motions. Earlier researchers performed an analytical study that showed good potential for lidar discrimination and tracking of two or three different fluorescent tracers at the same time. The present paper summarizes the multiple fluorescent tracer method, discusses its expected advantages and problems, and describes our field test of this new technique.

Eberhard, Wynn L.↗

Development of Nontargeted Workflow of Occupational Exposure by Infrared Ion Spectroscopy and Silicone Wristbands’ Passive Sampling

Monitoring chemical exposure has well-established protocols and procedures for occupational health and industrial hygiene across various career fields and in a variety of occupational and environmental conditions. Iterative analytical development has led to validated methods to provide employers and employees with safe working conditions in terms of industrial hygiene. These validated methods are commonly supported by commercial laboratories. Here, this workflow is explicitly a targeted approach in which sampling media, sample preparation, chemical separation, quantitative target detection, and post processing are well established. This workflow also relies on commercially available chemical surrogates, isotopically labeled internal standards, and certified/standard reference materials from reputable vendors. An untargeted workflow lacks many key ingredients of validated analytical methods to include the known chemical target.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spectroscopic Chemical Analysis Methods and Apparatus

Spectroscopic chemical analysis methods and apparatus are disclosed which employ deep ultraviolet (e.g. in the 200 nm to 300 nm spectral range) electron beam pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor light emitting devices, and hollow cathode metal ion lasers to perform non-contact, non-invasive detection of unknown chemical analytes. These deep ultraviolet sources enable dramatic size, weight and power consumption reductions of chemical analysis instruments. In some embodiments, Raman spectroscopic detection methods and apparatus use ultra-narrow-band angle tuning filters, acousto-optic tuning filters, and temperature tuned filters to enable ultra-miniature analyzers for chemical identification. In some embodiments Raman analysis is conducted along with photoluminescence spectroscopy (i.e. fluorescence and/or phosphorescence spectroscopy) to provide high levels of sensitivity and specificity in the same instrument.

Hug, William F.↗

Spectroscopic Chemical Analysis Methods and Apparatus

Spectroscopic chemical analysis methods and apparatus are disclosed which employ deep ultraviolet (e.g. in the 200 nm to 300 nm spectral range) electron beam pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor light emitting devices, and hollow cathode metal ion lasers to perform non-contact, non-invasive detection of unknown chemical analytes. These deep ultraviolet sources enable dramatic size, weight and power consumption reductions of chemical analysis instruments. In some embodiments, Raman spectroscopic detection methods and apparatus use ultra-narrow-band angle tuning filters, acousto-optic tuning filters, and temperature tuned filters to enable ultra-miniature analyzers for chemical identification. In some embodiments Raman analysis is conducted along with photoluminescence spectroscopy (i.e. fluorescence and/or phosphorescence spectroscopy) to provide high levels of sensitivity and specificity in the same instrument.

Hug, William F.↗

Total metals & anion concentration data; Slate River floodplain, Crested Butte, CO; May 2020-September 2020

This data package includes processed and undiluted measurements for metal and anion concentrations from pore water (groundwater) samples from the Slate River floodplain of Crested Butte, CO, a focus field site for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? Samples were collected between May and September of 2020. These measurements were all recorded at the Arizona Laboratory for Emerging Contaminants (ALEC) at the University of Arizona located in Tucson, AZ. Groundwater samples were extracted from a network of installed rhizon (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the river floodplain. All water samples were shaded from sun exposure during extraction from the subsurface and preserved at 4C until measured at ALEC.Analysis by ICP-MS:Measurements for total metals were made on the Agilent 7700x ICP-MS (for total metals) – Agilent Technologies, Santa Clara, CA.The analytical QA/QC protocol was adapted from US EPA Method 200.8 for analysis by ICP-MS. Calibration standards were prepared from multi-element stock solution (Sigma-Aldrich Multielement standard solution for ICP, St. Louis, MO) using matrix matched to sample solutions (either 2% HCl or HNO3 from AriStar Plus,grade acids from VWR Scientific). Calibration curves include at least 7 points with correlation coefficients > 0.995. The QC protocol includes a continuing calibration blank (CCB), a continuing calibration verification (CCV) solution and at least one quality control sample (QCS) to be analyzed just after calibration and again after every 12 samples and at the completion of the run. The QCS solutions are from an independent source, such as NIST SRM 1643e - Trace Elements in Water, or QCS solutions from High Purity Standards (Charleston, SC). Acceptable QC responses must be between 90 and 110% of the certified value. An internal standard (Rh) is added via on-line addition into the sample line using a mixing tee.Analysis by Ion Chromatography (Anions):The protocol follows Method 4110 in Standard Methods for Examination of Water and Wastewater.The instrument used is the Thermo Scientific Dionex ICS-6000 using AS+AG22 column set for anion analysis with isocratic method using sodium carbonate eluent. Detection is by chemical suppression of eluent conductivity. Quality control solutions and mixed analyte standards purchased from Inorganic Ventures, Christiansburg, VA.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗

Exploring the Landscape of Distributed Graph Clustering on Leadership Supercomputers

The rapid growth of large-scale datasets in fields like biology and social networks has driven the need for advanced graph analytics techniques. Community detection, a fundamental task in graph analytics, identifies closely connected groups of nodes within a network, providing valuable insights across various disciplines. This study focuses on two classic community detection methods, the Louvain algorithm and Markov Clustering (MCL), and evaluates the performance of two prominent distributed community detection algorithms: HiPDPL-GPU, our prior implementation, and HipMCL. We conduct experiments on GPU-accelerated heterogeneous HPC systems, Summit and Frontier, to assess their performance under varying conditions. Our objective is to identify the strengths and weaknesses of these algorithms in terms of scalability, and quality of solutions. We evaluate these algorithms on a diverse set of 70+ networks spanning 13 domains, with sizes ranging up to 4.2 billion edges. Our results demonstrate that HiPDPL-GPU consistently outperforms HipMCL, especially for large-scale networks. HiPDPL-GPU achieves significantly faster runtimes (47x to 1439x), higher modularity scores, and improved scalability. These findings highlight HiPDPL-GPU as a promising solution for efficient and effective large-scale graph analytics in diverse application domains, and provide insights into the feasibility of using MCL-based approaches for certain application domains.

Community detection, graph algorithms↗

Two-color, intracavity pump–probe, cavity ringdown spectroscopy

Here, we report a proof-of-principle demonstration of intracavity pump–probe, cavity ringdown (CRD) detection in a three-mirror, traveling-wave cavity. With cavity-enhanced pump power and probe absorption path length, the technique is a generally applicable, high-sensitivity, high-selectivity detection method. In our experiments, the pump radiation is switched off during every other probe ringdown, which allows uncorrelated measurements of analyte and background cavity decay rates. The net, two-color signal from the difference between the pump-on and pump-off decay rates is immune to empty-CRD drifts and spectral overlaps from non-target molecular transitions. The immunity to the ringdown drifts allows longer signal-averaging and, thus, higher detection sensitivity. The ability to compensate for the background absorption enhances the detection selectivity in spectrally congested regions. Our technique is well-suited for trace-detection in the mid-IR region, where pump–probe schemes based on strong rovibrational transitions can be applied. In this work, two-color CRD detection is implemented on a ladder-type, three-level system based on the N 2 O, ν 3 = 1 ← 0, P(19) (pump) and ν 3 = 2 ← 1, R(18) (probe), rovibrational transitions. By frequency-locking two-quantum cascade lasers to the p-polarization (pump, Finesse = 5280) and s-polarization (probe, Finesse = 67 700) cavity modes, we achieve high intracavity pump power (36 W) and high probe ringdown rates (>2 kHz). The observed two-color spectra are simulated by a density-matrix, three-level system model that is solved under the constraints of the cavity resonance conditions. In addition to its background compensation capability, experimental flexibility in the selection of pump–probe schemes and signal insensitivity to intracavity laser power are further features that enhance the utility of our technique for mid-IR trace-detection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗