Search NASA⌕ Search

SEARCH · Search NASA

Results for “Angle Measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Interfacial Chemistry Involved in Selective Separation of NMC/LMO and LCO/LMO Binary Cathode Materials by Froth Flotation Using Oleic Acid

The variability in cathode compositions within recycled lithium-ion battery (LIB) feedstocks poses a significant challenge to efficient downstream refining processes. This study demonstrates the feasibility of using froth flotation with oleic acid as a collector to selectively separate lithium nickel-manganese-cobalt oxide (NMC) and lithium cobalt oxide (LCO) from lithium manganese oxide (LMO) materials. Laboratory-scale flotation tests achieved an 80% separation efficiency in a single stage, producing a froth product with >90% purity of NMC/LCO at approximately 90% yield. Concurrently, the LMO materials were enriched in the sink product with ∼90% purity and ∼90% yield. This approach was further validated using recycled cathode materials, confirming its applicability to realistic feedstocks. The underlying mechanism governing the selective separation of NMC/LCO from LMO was investigated using ζ-potential measurements, contact angle measurements, bubble-particle attachment experiments, and X-ray photoelectron spectroscopy (XPS) analysis. Both contact angle and bubble-particle attachment results confirmed that oleic acid adsorption rendered NMC and LCO surfaces hydrophobic, thereby enhancing flotation recovery. At pH 5, oleic acid adsorbed preferentially onto NMC and LCO surfaces via electrostatic interactions, while exhibiting minimal adsorption on LMO surfaces. However, separation efficiency deteriorated at higher pH, which was attributed to the co-flotation of LMO materials caused by oleate chemisorption on MnOH + species. This work establishes froth flotation as a viable cathode/cathode separation strategy, providing a low-cost, scalable pathway to preconcentrate and enrich nickel-rich and cobalt-rich cathode active materials from incompatible cathode chemistries for direct recycling or hydrometallurgical processing. Furthermore, this study reveals, for the first time, the mechanism of oleate adsorption on the surface of different cathode materials.

PH↗

Interfraction patient motion and implant displacement in prostate high dose rate brachytherapy

Purpose: To quantify movement of prostate cancer patients undergoing treatment, using an in-house developed motion sensor in order to determine a relationship between patient movement and high dose rate (HDR) brachytherapy implant displacement. Methods: An electronic motion sensor was developed based on a three axis accelerometer. HDR brachytherapy treatment for prostate is delivered at this institution in two fractions 24 h apart and 22 patients were monitored for movement over the interval between fractions. The motion sensors functioned as inclinometers, monitoring inclination of both thighs, and the inclination and roll of the abdomen. The implanted HDR brachytherapy catheter set was assessed for displacement relative to fiducial markers in the prostate. Angle measurements and angle differences over a 2 s time base were binned, and the standard deviations of the resulting frequency distributions used as a metric for patient motion in each monitored axis. These parameters were correlated to measured catheter displacement using regression modeling. Results: The mean implant displacement was 12.6 mm in the caudal direction. A mean of 19.95 h data was recorded for the patient cohort. Patients generally moved through a limited range of angles with a mean of the exception of two patients who spent in excess of 2 h lying on their side. When tested for a relationship between movement in any of the four monitored axes and the implant displacement, none was significant. Conclusions: It is not likely that patient movement influences HDR prostate implant displacement. There may be benefits to patient comfort if nursing protocols were relaxed to allow patients greater freedom to move while the implant is in situ.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A digital pitch and roll monitor

A digital pitch and roll monitor was developed that will provide an easy measurement of angle in two axes simultaneously to an accuracy of approximately 0.005 degree. This system provides advantages over any other commercially available angle-measuring device in that an inexperienced operator can obtain quick reliable measurements. The system utilizes three mutually perpendicular accelerometers, mounted on an inclinometer base, and the intelligent signal conditioning equipment needed to convert the output of these sensors to pitch and roll. The two-axis inclinometer consists of three mutually perpendicular accelerometers mounted on an inclinometer base, three digital multimeters to provide power to the accelerometers and digitize their output, a computer to calculate the angles, and a printer to provide hardcopy output.

Finley, Tom↗

Methods to measure contact angles in scCO 2 -brine-sandstone systems

Numerous methods are used to measure contact angles ( θ ) in multiphase systems. The wettability and θ are primary controls on CO 2 residual trapping during Geologic Carbon Storage (GCS) and determining these values within rock pores is paramount to increasing storage efficiency. One traditional experimental approach is the sessile drop method which involves θ measurements on a single image of droplets. More recent developments utilize X-ray micro-computed tomography (CT) scans which provide the resolutions necessary to image in situ θ of fluids at representative conditions; however, experimental micro-CT data is limited and varied. To further examine θ distributions in supercritical-CO 2 -brine-sandstone systems, a combination of manual and automated θ measurement methods were utilized to measure θ using both sessile drop and micro-CT images of two sandstone cores. Here, the purpose of this work was threefold: (1) compare two current and two new θ measuring methods using micro-CT images of scCO 2 -brine-sandstone systems; (2) determine how traditional experimental method (sessile drop) θ results compare to in situ θ results (micro-CT); and (3) determine if the Matlab Contact Angle Algorithm (MCAA) from Klise et al. (2016) can be used to measure θ scCO 2 -brine-sandstone systems.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of electrolytic tilt sensors for measuring model angle of attack in wind tunnel tests

The results of a laboratory evaluation of electrolytic tilt sensors as potential candidates for measuring model attitude or angle of attack in wind tunnel tests are presented. The performance of eight electrolytic tilt sensors was compared with that of typical servo accelerometers used for angle-of-attack measurements. The areas evaluated included linearity, hysteresis, repeatability, temperature characteristics, roll-on-pitch interaction, sensitivity to lead-wire resistance, step response time, and rectification. Among the sensors being evaluated, the Spectron model RG-37 electrolytic tilt sensors have the highest overall accuracy in terms of linearity, hysteresis, repeatability, temperature sensitivity, and roll sensitivity. A comparison of the sensors with the servo accelerometers revealed that the accuracy of the RG-37 sensors was on the average about one order of magnitude worse. Even though a comparison indicates that the cost of each tilt sensor is about one-third the cost of each servo accelerometer, the sensors are considered unsuitable for angle-of-attack measurements. However, the potential exists for other applications such as wind tunnel wall-attitude measurements where the errors resulting from roll interaction, vibration, and response time are less and sensor temperature can be controlled.

Wong, Douglas T.↗

Abstract for CRADA between NETL and the University of Massachusetts Lowell (AGMT-1275)

The demand for printed electronics over conventional electronics is growing each year due to their low costs, low material waste during manufacturing, and compatibility with flexible substrates. The development of inks for printed electronics is a challenge because each printing technology requires different viscosities and curing behaviors to create devices with controlled structures at the micron scale, or smaller. Carbon is a great candidate for fabricating printed electronics devices because it is inexpensive and earth abundant, easily functionalized to impart miscibility with solvent systems, and has electrical properties that can be tuned from insulating to conducting. Despite these advantages, carbons are rarely used for printed electronics because there is a scarcity of inks available for non-contact printing technologies. To address these challenges, the National Energy Technology Laboratory (NETL) will collaborate with the University of Massachusetts Lowell (Participant) through its Printed Electronics Research Collaborative (PERC) to develop engineered carbons and ink formulations optimized specifically for printing radio- and microwave-frequency electronic devices using ink jet, aerosol jet, syringe dispensing, and other additive manufacturing techniques. NETL will process coal, petroleum, and other carbon feedstocks to make engineered carbons with the appropriate composition, microstructure, surface functionalization, and particle morphologies needed to stabilize ink suspensions and impart useful electronic properties to printed devices. The University of Massachusetts Lowell will utilize these engineered carbons to determine which solvent systems and ink additives are needed to achieve the appropriate viscosity, stability, and printability to make useful ink formulations. The University of Massachusetts Lowell will then utilize these inks to manufacture printed resistors and conductors using inkjet, aerosol jet, and syringe dispensing printing methods and will characterize device performance using four-point probe resistivity measurements, contact angle measurements to assess wettability, adhesion evaluation to various substrates, and focused ion beam and scanning electron microscopy for surface and density investigations of printed devices.

36 MATERIALS SCIENCE↗

Universal precision sine bar attachment

An improved sine bar apparatus for the precise measurement of angles for machining operation. The sine bar apparatus comprises a flat, rectangular base which has an upper and a lower surface with four sides. A collet adapter extended from one side of the base at right angles thereto in a plane which is parallel to the upper surface of the base and there is at least one slot extending transversely of one side of the base. A reference bar is attached to one of the other sides of the base and has a support surface which extends above the upper surface of the base. An elongated, generally rectangular sine bar, which has a reference surface extending along one side, is pivotally connected to the base and is supported on the upper surface of the base. The sine bar is pivotally connected at a point intermediate its ends, though the transverse slot adjacent the side of which the reference bar is attached, and has one of its ends in contact with the support surface of the reference bar. The other end of the sine bar is separated from the support surface of the reference bar means of a plurality of gauges or gauge blocks which are precisely machined to cause the reference surface of the sine bar to form a predetermined angle with the longitudinal axis of the collet adapter. The reference bar and the sine bar can be attached to either of the three sides of the base to provide a variation in the angle measured.

Franklin D Mann↗

Metrology of Large Parts

As discussed in the first chapter of this book, there are many different methods to measure a part using optical technology. Chapter 2 discussed the use of machine vision to measure macroscopic features such as length and position, which was extended to the use of interferometry as a linear measurement tool in chapter 3, and laser or other trackers to find the relation of key points on large parts in chapter 4. This chapter looks at measuring large parts to optical tolerances in the sub-micron range using interferometry, ranging, and optical tools discussed in the previous chapters. The purpose of this chapter is not to discuss specific metrology tools (such as interferometers or gauges), but to describe a systems engineering approach to testing large parts. Issues such as material warpage and temperature drifts that may be insignificant when measuring a part to micron levels under a microscope, as will be discussed in later chapters, can prove to be very important when making the same measurement over a larger part. In this chapter, we will define a set of guiding principles for successfully overcoming these challenges and illustrate the application of these principles with real world examples. While these examples are drawn from specific large optical testing applications, they inform the problems associated with testing any large part to optical tolerances. Manufacturing today relies on micrometer level part performance. Fields such as energy and transportation are demanding higher tolerances to provide increased efficiencies and fuel savings. By looking at how the optics industry approaches sub-micrometer metrology, one can gain a better understanding of the metrology challenges for any larger part specified to micrometer tolerances. Testing large parts, whether optical components or precision structures, to optical tolerances is just like testing small parts, only harder. Identical with what one does for small parts, a metrologist tests large parts and optics in particular to quantify their mechanical properties (such as dimensions, mass, etc); their optical prescription or design (i.e. radius of curvature, conic constant, vertex location, size); and their full part shape. And, just as with small parts, a metrologist accomplishes these tests using distance measuring instruments such as tape measures, inside micrometers, coordinate measuring machines, distance measuring interferometers; angle measuring instruments such as theodolites, autocollimators; and surface measuring instruments including interferometers, stylus profilers, interference microscopes, photogrammetric cameras, or other tools. However, while the methodology may be similar, it is more difficult to test a large object for the simple reason that most metrologists do not have the necessary intuition. The skills used to test small parts or optics in a laboratory do not extrapolate to testing large parts in an industrial setting any more than a backyard gardener might successfully operate a farm. But first, what is a large part? A simple definition might be the part's size or diameter. For optics and diffuse surface parts alike, the driving constraint is ability to illuminate the part's surface. For reflective convex mirrors, large is typically anything greater than 1 meter. But, for refractive optics, flats or convex mirrors, large is typically greater than 0.5 meter. While a size definition is simple, it may be less than universal. A more nuanced definition might be that a large part is any component which cannot be easily tested in a standard laboratory environment, on a standard vibration isolated table using standard laboratory infrastructure. A micro-switch or a precision lens might be easily measured to nanometer levels under a microscope in a lab, but a power turbine spline or a larger telescope mirror will not fit under that microscope and may not even fit on the table.

Stahl, H. Philip↗

Broadband wide-angle dispersion measurements: Instrumental setup, alignment, and pitfalls

The construction, alignment, and performance of a setup for broadband wide-angle dispersion measurements, with emphasis on surface plasmon resonance (SPR) measurements, are presented in comprehensive detail. In contrast with most SPR instruments working with a monochromatic source, this setup takes advantage of a broadband/white light source and has full capability for automated angle vs. wavelength dispersion measurements for any arbitrary nanostructure array. A cylindrical prism is used rather than a triangular one in order to mitigate refraction induced effects and allow for such measurements. Although seemingly simple, this instrument requires use of many non-trivial methods in order to achieve proper alignment over all angles of incidence. Here we describe the alignment procedure for such a setup, the pitfalls introduced from the finite beam width incident onto the cylindrical prism, and deviations in the reflected/transmitted beam resulting from the finite thickness of the sample substrate. We address every one of these issues and provide experimental evidences on the success of this instrument and the alignment procedure used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precise time dissemination and applications development on the Bonneville Power Administration system

The Bonneville Power Administration (BPA) uses IRIG-B transmitted over microwave as its primary system time dissemination. Problems with accuracy and reliability have led to ongoing research into better methods. BPA has also developed and deployed a unique fault locator which uses precise clocks synchronized by a pulse over microwaves. It automatically transmits the data to a central computer for analysis. A proposed system could combine fault location timing and time dissemination into a Global Position System (GPS) timing receiver and close the verification loop through a master station at the Dittmer Control Center. Such a system would have many advantages, including lower cost, higher reliability, and wider industry support. Test results indicate the GPS has sufficient accuracy and reliability for this and other current timing requirements including synchronous phase angle measurements. A phasor measurement system which provides phase angle has recently been tested with excellent results. Phase angle is a key parameter in power system control applications including dynamic braking, DC modulation, remedial action schemes, and system state estimation. Further research is required to determine the applications which can most effectively use real-time phase angle measurements and the best method to apply them.

K. E. Martin↗

Electro-optical spin measurement system

An electro-optical spin measurement system for a spin model in a spin tunnel includes a radio controlled receiver/transmitter, targets located on the spin model, optical receivers mounted around the perimeter of the spin tunnel and the base of the spin tunnel for receiving data from the targets, and a control system for accumulating data from the radio controlled receiver and receivers. Six targets are employed. The spin model includes a fuselage, wings, nose, and tail. Two targets are located under the fuselage of the spin model at the nose tip and tail. Two targets are located on the side of the fuselage at the nose tip and tail, and a target is located under each wing tip. The targets under the fuselage at the nose tip and tail measure spin rate of the spin model, targets on the side of the fuselage at the nose tip and tail measure angle of attack of the spin model, and the targets under the wing tips measure roll angle of the spin model. Optical receivers are mounted at 90 degree increments around the periphery of the spin tunnel to determine angle of attack and roll angle measurements of the spin model. Optical receivers are also mounted at the base of the spin tunnel to define quadrant and position of the spin model and to determine the spin rate of the spin model.

Fodale, Robert↗

An evaluation of complementary approaches to elucidate fundamental interfacial phenomena driving adhesion of energetic materials

In this study, cohesive Hamaker constants of solid materials are measured via optical and dielectric properties (i.e., Lifshitz theory), inverse gas chromatography (IGC), and contact angle measurements. To date, however, a comparison across these measurement techniques for common energetic materials has not been reported. This has been due to the inability of the community to produce samples of energetic materials that are readily compatible with contact angle measurements. Here we overcome this limitation by using physical vapor deposition to produce thin films of five common energetic materials, and the contact angle measurement approach is applied to estimate the cohesive Hamaker constants and surface energy components of the materials. The cohesive Hamaker constants range from 85 zJ to 135 zJ across the different films. When these Hamaker constants are compared to prior work using Lifshitz theory and nonpolar probe IGC, the relative magnitudes can be ordered as follows: contact angle > Lifshitz > IGC. Furthermore, the dispersive surface energy components estimated here are in good agreement with those estimated by IGC. Due to these results, researchers and technologists will now have access to a comprehensive database of adhesion constants which describe the behavior of these energetic materials over a range of settings.

36 MATERIALS SCIENCE↗

Measurement of CP observables in B{sup {+-}{yields}D}{sub CP}K{sup {+-}}decays and constraints on the CKM angle {gamma}

Using the entire sample of 467x10{sup 6} {Upsilon}(4S){yields}BB decays collected with the BABAR detector at the PEP-II asymmetric-energy B factory at the SLAC National Accelerator Laboratory, we perform an analysis of B{sup {+-}}{yields}DK{sup {+-}}decays, using decay modes in which the neutral D meson decays to either CP-eigenstates or non-CP-eigenstates. We measure the partial decay rate charge asymmetries for CP-even and CP-odd D final states to be A{sub CP+}=0.25{+-}0.06{+-}0.02 and A{sub CP-}=-0.09{+-}0.07{+-}0.02, respectively, where the first error is the statistical and the second is the systematic uncertainty. The parameter A{sub CP+} is different from zero with a significance of 3.6 standard deviations, constituting evidence for direct CP violation. We also measure the ratios of the charged-averaged B partial decay rates in CP and non-CP decays, R{sub CP+}=1.18{+-}0.09{+-}0.05 and R{sub CP-}=1.07{+-}0.08{+-}0.04. We infer frequentist confidence intervals for the angle {gamma} of the unitarity triangle, for the strong phase difference {delta}{sub B}, and for the amplitude ratio r{sub B}, which are related to the B{sup -}{yields}DK{sup -} decay amplitude by r{sub B}e{sup i({delta}{sub B}-{gamma})}=A(B{sup -}{yields}D{sup 0}K{sup -})/A(B{sup -}{yields}D{sup 0}K{sup -}). Including statistical and systematic uncertainties, we obtain 0.24<r{sub B}<0.45 (0.06<r{sub B}<0.51) and, modulo 180 deg., 11.3 deg. <{gamma}<22.7 deg. or 80.8 deg. <{gamma}<99.2 deg. or 157.3 deg. <{gamma}<168.7 deg. (7.0 deg. <{gamma}<173.0 deg.) at the 68% (95%) confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Technique to measure contact angle of micro/nanodroplets using atomic force microscopy

Contact angle is the primary parameter that characterizes wetting; however, the measurement techniques have been limited to droplets with a diameter as low as about 50 {mu}m. The authors developed an atomic force microscopy-based technique to measure the contact angle of micro- and nanodroplets deposited using a modified nanoscale dispensing tip. The obtained contact angle results were compared with those of a macrodroplet (2.1 mm diameter). It was found that the contact angle on various surfaces decreases with decreasing the droplet size.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A fiber-optic technique for the measurement of contact angle in a clearance-fit pin-loaded hole

A fiber-optic technique for measuring contact angle during pin loading of a specimen is proposed. The experimental design and procedures for loading a 49.8-mm-diameter instrumented pin into an quasi-isotropic graphite-epoxy specimen are described. The optical fiber was located just above the surface of the pin outer diameter in order to obtain accurate pin-hole contact-angle measurements at increasing load levels. The movement of the optical fiber through the no-contact, contact, and no-contact regions is discussed; the photodiode output decreased monotonically as the fiber moved from the no-contact to the contact region and then decreased monotonically as the fiber moved from the contact region to the no-contact region. Variations in the contact angle measurements are examined as function of applied load level. The measurements are compared to contact angle values obtained using a finite element analysis and an electrical technique; it is determined that the data correlate well.

Prabhakaran, R.↗

Measurement method for roll angular displacement with a high resolution by using diffraction gratings and a heterodyne interferometer

The roll angle measurement is difficult to be achieved directly using a typical commercial interferometer due to its low sensitivity in axial direction, where the axial direction is orthogonal to the plane of the roll angular displacement. A roll angle measurement method combined diffraction gratings with a laser heterodyne interferometer is discussed in this paper. The diffraction grating placed in the plane of a roll angular displacement and the interferometer arranged in the plane's orthogonal direction, constitute the measurement pattern for the roll angle with high resolution. The roll angular displacement, considered as the linear, can be tested precisely when the corresponding angle is very small. Using the proposed method, the angle roll measurement obtains the high resolution of 0.002{sup ″}. Experiment has proved its feasibility and practicability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗