Search NASA⌕ Search

SEARCH · Search NASA

Results for “Assay”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Bead-Based Assays for Biodetection: From Flow-Cytometry to Microfluidics

ABSTRACT The potential for the use of biological agents by terrorists is a real threat. Two approaches for detection of biological species will be described: 1) The use of microbead arrays for multiplexed flow cytometry detection of cytokines and botulinum neurotoxin simulant, and 2) a microfluidic platform for capture and separation of different size superparamagnetic nanoparticles followed by on-chip fluorescence detection of the sandwich complex. The methods and automated fluidic systems used for trapping functionalized microbeads will be described. This approach allows sample, assay reagents, and wash solutions to be perfused over a micro-column of beads, resulting in faster and more sensitive assays. The automated fluidic approach resulted in up to five-fold improvements in assay sensitivity/speed as compared to identical assays performed in a typical manual batch mode. A second approach for implementing multiplexed bead-based assays without using flow cytometry detection is currently under development. The goal of the microfluidic-based approach is to achieve rapid (<20 minutes), multiplexed (> 3 bioagents) detection using a simple and low-cost, integrated microfluidic/optical detection platform. Using fiber-optic guided laser-induced fluorescence, assay detection limits were shown to be in the 100’s of picomolar range (10’s of micrograms per liter) for botulinum neurotoxin simulant without any optimization of the microfluidic device or optical detection approach. Video taping magnetic nanoparticle capture and release was used to improve understanding of the process and revealed interesting behavior.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Gamma-ray imaging assay of cells 3-5 of the east cell line in the 235-F plutonium fuel form facility

In August and September, 2016, scientists from the Savannah River National Laboratory (SRNL) took a series of gamma-ray imaging measurements through the cell windows in front of Cells 3-5 on the east line of the Plutonium Fuel Form (PuFF) Facility using an electrically cooled, high-purity germanium detector. A Germanium Gamma Ray Imager (GeGI) was utilized since it allowed for the location from which the radiation was being emitted to be identified by incoming gamma-ray energy. This measurement technique provided a tool which allowed for the relative concentration of Pu-238 to be mapped throughout each cell. The mapping and new assay data were then used to update the model used in an assay discussed in a 2014 report (SRNL-STI-2014-00629) and to calculate a more accurate value for the holdup in each of the cells [1]. Note that the mapping and new assay data did not replace the previous assay data in the model. Rather, the mapping and new assay data provided additional details on source distribution, which supplemented the previous assay data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Delayed Gamma-ray Assay for Nuclear Materials Safeguards. Comprehensive Technology Readiness Assessment

Spectroscopic analysis of beta-delayed gamma-rays emitted from fission products following active interrogation was investigated as a non-destructive assay technique for detection and characterization of nuclear materials in shielded and complex configurations. This measurement technique is expected to be applicable to a variety of applications within the nuclear material safeguards, arms control, and emergency response areas, where active neutron interrogation is acceptable. Potential applications of the delayed gamma-ray assay in the nuclear material safeguards area include characterization of U and Pu isotopic content in spent and unirradiated nuclear fuel, enrichment measurements, verification of bulk material in containers, and the characterization of nuclear wastes. In the arms control area, this method can be used as a part of warhead dismantlement measurements to confirm separation of components, and may be applicable in warhead confirmation. In the context of emergency response, it can be used for detailed diagnostics of an unknown item. At present, the delayed gamma-ray assay technology reliably qualifies for the Technical Readiness Level 3 (TRL 3). The R&D work completed under this project has successfully demonstrated the empirical proof-of-concept for this active interrogation technology for a variety of measurement configurations, neutron sources, and nuclear material samples. A robust first-principles analytical signature modeling methodology was developed, experimentally validated, and can be easily extrapolated to a range of realistic measurement scenarios. Several response analysis methodologies have been implemented and deemed reliable for a variety of active interrogation applications in the areas of nuclear material safeguards, arms control, and emergency response. The initial readiness level before the start of this project was assessed at TRL 0, since only fragmentary records of the signature observations and speculative statements of the relevant non-destructive assay applications existed at that time. The delayed gamma-ray technology readiness can be easily advanced to TRL 4 in a short period, if a certain measurement application is specified and set for a demonstration in a laboratory environment. The critical hardware components of the delayed gamma-ray measurement technology (neutron generators, gamma-ray spectrometers) are readily available as COTS and can be configured for a specific deployment configuration. The primary risk of the delayed gamma-ray assay methodology is defined by the applicationspecific uncertainties. Evaluation of the system performance can be effectively completed once the expected measurement purpose, nuclear material characteristics, dimensions, and radiation exposure constraints are specified. A minor risk can be associated with the delayed gamma-ray response analysis techniques. Several approaches were proposed and demonstrated primarily using the modeled signatures. The observed performance may not be easily transferrable to the conditions of a real measurement setup, and some additional R&D may be required. Overall, the delayed gamma-ray assay technology can be recommended for follow-up demonstrations addressing relevant measurement applications in the areas of nuclear material safeguards, arms control, and emergency response.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of high throughput and in vitro assays for analyzing RNA modifications

Modifications on RNAs play major roles in their stability, translation, and enzymatic activity. Despite its importance, the current techniques are insufficient to study the structure and function of RNA modifications. Indeed, the National Academies of Science, Engineering and Medicine indicate that developing new tools and further study the function of RNA modifications is strategically a high priority for advancing science in the coming years (https://www.nationalacademies.org/our-work/toward-sequencing-and-mapping-of-rna-modifications). RNA modifications occur in all domains of life controlling processes such as RNA turnover, translation regulation, cellular defenses and bioproduction. Our preliminary data indicated that the insulin mRNA might get ADP-ribosylated by the ADP-ribosyltransferase PARP12. RNA ADP-ribosylation has been described in Escherichia coli. Combined to the fact that ADP-ribosyltransferase (PARP) genes are conserved throughout evolution we hypothesize that this modification might play essential roles in cells. Therefore, we proposed to develop sequencing techniques and in vitro enzymatic assays to identify and validate ADP-ribosylation motifs and sites. Here we report the development of RNA-seq and qPCR assays to identify ADP-ribosylated RNAs, in addition to a nicotinamide adenosine dinucleotide (NAD – ADP-ribosylation donor) consumption assay and an enzyme-linked immunosorbent assay (ELISA) to measure ADP-ribosyltransferase activity. Testing these assays with the insulin mRNA confirmed that this transcript is ADP-ribosylated. These assays will not only enable studying the function of ADP-ribosylation but can be easily adapted for studying other RNA modifications. This will open opportunities to study RNA modifications in different model systems from bacteria to viruses to plants, bringing insights into their cellular functions and the possibility of targeting them for biotechnological applications.

59 BASIC BIOLOGICAL SCIENCES↗

Analysis of Hexanitrostilbene (HNS) and Dipicryethane (DPE) for Mutagenicity by the Ames/Salmonella Assay

The Ames/Salmonella assay, developed by Professor Bruce Ames at the University of California, Berkeley, is a rapid and sensitive assay for detecting mutagenicity of various chemical compounds (Maron and Ames, 1983). It is a widely accepted short-term assay for detecting chemicals that induce mutations in the histidine (his) gene of Salmonella typhimurium. This is a reverse mutation assay that detects the mutational reversion of his-dependent Salmonella to the his-independent counterpart. Thereby, mutagenic compounds will increase the frequency of occurrence of his-independent bacterial colonies. The assay utilizes the specific genetically constructed strains of bacteria either with or without mammalian metabolic activation enzymes (S9), Aroclor induced rat liver homogenate to assess the mutagenicity of different compounds. In this study, we will use the Ames/Salmonella assay to investigate the mutagenicity of Hexanitrostilbene (HNS) from both Bofors and Pantex, and Dipicryethane (DPE).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

N α -acetyl-L-ornithine deacetylase from Escherichia coli and a ninhydrin-based assay to enable inhibitor identification

Bacteria are becoming increasingly resistant to antibiotics, therefore there is an urgent need for new classes of antibiotics to fight antibiotic resistance. Mammals do not express N α -acetyl-L-ornithine deacetylase (ArgE), an enzyme that is critical for bacterial survival and growth, thus ArgE represents a promising new antibiotic drug target, as inhibitors would not suffer from mechanism-based toxicity. A new ninhydrin-based assay was designed and validated that included the synthesis of the substrate analog N 5 , N 5 -di-methyl N α -acetyl-L-ornithine (k cat /K m = 7.32 ± 0.94 × 10 4 M -1 s -1 ). This new assay enabled the screening of potential inhibitors that absorb in the UV region, and thus is superior to the established 214 nm assay. Using this new ninhydrin-based assay, captopril was confirmed as an ArgE inhibitor (IC 50 = 58.7 μM; K i = 37.1 ± 0.85 μM), and a number of phenylboronic acid derivatives were identified as inhibitors, including 4-(diethylamino)phenylboronic acid (IC 50 = 50.1 μM). Selected inhibitors were also tested in a thermal shift assay with ArgE using SYPRO Orange dye against Escherichia coli ArgE to observe the stability of the enzyme in the presence of inhibitors (captopril K i = 35.9 ± 5.1 μM). The active site structure of di-Zn Ec ArgE was confirmed using X-ray absorption spectroscopy, and we reported two X-ray crystal structures of E. coli ArgE. In summary, we describe the development of a new ninhydrin-based assay for ArgE, the identification of captopril and phenylboronic acids as ArgE inhibitors, thermal shift studies with ArgE + captopril, and the first two published crystal structures of ArgE (mono-Zn and di-Zn).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chronic Cardiotoxicity Assays Using Human Induced Pluripotent Stem Cell-Derived Cardiomyocytes (hiPSC-CMs)

Cardiomyocytes (CMs) differentiated from human induced pluripotent stem cells (hiPSCs) are increasingly used in cardiac safety assessment, disease modeling and regenerative medicine. A vast majority of cardiotoxicity studies in the past have tested acute effects of compounds and drugs; however, these studies lack information on the morphological or physiological responses that may occur after prolonged exposure to a cardiotoxic compound. In this review, we focus on recent advances in chronic cardiotoxicity assays using hiPSC-CMs. We summarize recently published literature on hiPSC-CMs assays applied to chronic cardiotoxicity induced by anticancer agents, as well as non-cancer classes of drugs, including antibiotics, anti-hepatitis C virus (HCV) and antidiabetic drugs. We then review publications on the implementation of hiPSC-CMs-based assays to investigate the effects of non-pharmaceutical cardiotoxicants, such as environmental chemicals or chronic alcohol consumption. We also highlight studies demonstrating the chronic effects of smoking and implementation of hiPSC-CMs to perform genomic screens and metabolomics-based biomarker assay development. The acceptance and wide implementation of hiPSC-CMs-based assays for chronic cardiotoxicity assessment will require multi-site standardization of assay protocols, chronic cardiac maturity marker reproducibility, time points optimization, minimal cellular variation (commercial vs. lab reprogrammed), stringent and matched controls and close clinical setting resemblance. A comprehensive investigation of long-term repeated exposure-induced effects on both the structure and function of cardiomyocytes can provide mechanistic insights and recapitulate drug and environmental cardiotoxicity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Biochemical assays on plasminogen activators and hormones from kidney sources

Investigations were established for the purpose of analyzing the conditioned media from human embryonic kidney cell subpopulations separated in space by electrophoresis. This data is based on the experiments performed on STS-8 on the continuous flow electrophoresis system. The primary biological activity that was analyzed was plasminogen activator activity, but some assays for erythropoeitin and human granulocyte colony stimulating activity were also performed. It is concluded that a battery of assays are required to completely define the plasminogen activator profile of a conditioned media from cell culture. Each type of assay measures different parts of the mixture and are influenced by different parameters. The functional role of each assay is given along with an indication of which combination of assays are required to answer specific questions. With this type of information it is possible by combinations of assays with mathematical analysis to pinpoint a specific component of the system.

Barlow, Grant H.↗

Solid-state integrated real-time optical monitoring of biochemical assays

The disclosed technology includes a planar device for performing multiple biochemical assays at the same time, or nearly the same time. Each assay may include a biosample including a biochemical, enzyme, DNA, and/or any other biochemical or biological sample. Each assay may include one or more tags including dyes and/or other chemicals/reagents whose optical characteristics change based on chemical characteristics of the biological sample being tested. Each assay may be optically pumped to cause one or more of luminescence, phosphorescence, or fluorescence of the assay that may be detected by one or more optical detectors. For example, an assay may include two tags and a biosample. Each tag may be pumped by different wavelengths of light and may produce different wavelengths of light that is filtered and detected by one or more detectors. The pump wavelengths may be different from one another and different from the produced wavelengths.

Beer, N. Reginald↗

Design and testing of a combined neutron and gamma assay system for measuring fissile material in fuel and waste items - 15340

A combined neutron and gamma ray assay system for the measurement of fissile material in both fuel and waste items has been designed, modelled, developed and tested. The purpose of the system is to measure and characterize a wide range of fissile materials including uranium, plutonium, americium and mixed oxide fuel arising from a variety of processes and facilities across the United Kingdom. Dounreay Site Restoration Limited at Dounreay currently stores these items form the United Kingdom Nuclear Decommissioning Authority's un-irradiated fuel inventory. This inventory comprises historic materials from ex-United Kingdom Atomic Energy Authority nuclear fuel projects and experiments together with fast reactor fuel materials and some commercial fuel items as delivered to Dounreay for recovery. The combined assay system has been designed and constructed to support the operation of a fuel processing facility, which will be operated at Dounreay to treat these historic legacy fuel materials, making them suitable for long term storage. Appropriate characterization of the fissile material is required for safety, criticality control and nuclear materials safeguards purposes prior to final disposition. The system consists of both gamma ray and neutron measurement components. The results of a neutron measurement are combined with the gamma ray isotopic ratio measurement results to generate the assay result for the fissile material being characterized. The gamma ray component of the system employs a safeguards quality high purity Germanium detector with electro-mechanical cooling and the measurements of fissile material containers are made in a shielded chamber with a tin and copper graded lining. Containers of fissile material are rotated during the gamma ray measurement and a variable automatic steel collimator aperture mechanism is employed to adjust the measured count rate to control detector dead time. Gamma ray spectra are analysed using the plutonium and uranium isotopic ratio code PC/FRAM. The gamma ray system can also be configured to perform a direct assay of small quantities of uranium bearing material. For this assay measurement a series of cadmium filters can be positioned in front of the detector to reduce the contribution from 59 keV gamma rays from Am-241. In addition to gamma ray isotopic measurements, both active and passive neutron assay is performed by the system. The neutron-measuring component consists of a thick walled cylindrical polyethylene chamber, which provides neutron moderation for 30 one-inch diameter He-3 detector tubes located in re-entrant channels in the polyethylene moderator. Two removable polyethylene-inserts incorporating lower plug assemblies are provided, one with and one without a cadmium lining. Also two top plug units are provided, again one with cadmium and one without a cadmium liner. The Neutron Subsystem can be operated both as a passive and as an active neutron coincidence counter. In both fast and thermal active neutron mode, the neutron component employs two americium-beryllium (Am-Be) alpha-n neutron sources, one positioned in the top and the other in the bottom plug unit. The neutron sources are removed when the counter is operated in passive mode. Passive neutron detection efficiency and active neutron performance has been modelled using the MCNP Monte Carlo computer simulation code as part of the design process. In the absence of fissile samples, operation of the gamma ray component of the system has been tested initially using calibrated Eu-152 and Ba-133 gamma ray sources and the use of archived spectra from fissile material measurements. Initial testing of the neutron system has employed a calibrated Cf-252 spontaneous fission neutron source. Neutron testing has been confirmed using further MCNP simulations. The results of test measurements with the system are presented and compared with the results of MCNP measurement simulations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

WIPP Certification of the Retrieval Box Assay System at the Advanced Mixed Waste Treatment Plant, Idaho - 16241

The Retrieval Box Assay System (RBAS) at the Advanced Mixed Waste Treatment Plant (AMWTP) is an Imaging Passive Active Neutron system supplemented with a High Purity Germanium (HPGe) gamma system for the quantification of Pu-239 Fissile Gram Equivalent (FGE) and transuranic (TRU) alpha activity of waste containers of various sizes up to 249 cm x 149 cm x 198 cm (Length x Width x Height). The system was originally calibrated in 2002 (with a range of surrogate matrices and radioactive sources in a 213 cm x 122 cm x 122 cm FRP box) and has been operational for over a decade. As of August 2015, the RBAS has measured approximately 18,000 boxes (50,000 m3 of waste) which has subsequently been fed into the facility's treatment process. Its success, and the wide envelope of waste that it can characterize, has led AMWTP to extend the RBAS mission to include WIPP certification. As part of this new project, the instrument must be capable of meeting WIPP's Waste Acceptance Criteria (WAC) which include reporting activities and masses of the 10 WIPP-tracked radionuclides. The system will be required to assay sludge and debris waste streams, shredded waste and large metal items. The container size includes Standard Waste Box (SWBs), Fiberglass Reinforced Plywood (FRPs) and large Shredder Boxes. Sludge matrices will be loaded into 210-liter (55-gallon) drums and placed inside an SWB. After assay, boxes will be over-packed into SLB-II's for shipment to WIPP. The target waste streams will contain mixtures of Weapons Grade plutonium, Heat Source plutonium (high in Pu-238 content) and Mixed Oxide (MOX). The activity of the waste is expected to encompass a wide dynamic range of activity from low-level waste (LLW) to TRU with up to several hundred grams of plutonium. Some packages will have high gamma activity associated with fission and activation products such as Cs-137 and Co-60. The existing RBAS hardware (detectors, electronics, assay chamber etc.) was retained for this project. Two lead filters were provided and installed on the existing filter wheels to attenuate the gamma ray flux from the highest activity boxes to avoid overload of the HPGe detectors. The new software suite includes PC-FRAM (Version 5), which is used for the isotopic analysis of the gamma spectra. Integration of FRAM and neutron results is performed using a software package known as RBAS WIPP Analysis Reporting Software (RWARS). This package also performs matrix dependent background adjustments. Other upgrades provided include automated tests that identify when assay parameters fall outside a predetermined range and a new Quality Checking (QC) application. Minimum Detectable Activity (MDA) values were determined for the active and passive neutron modes as a function of measured matrix correction indices. The resulting Minimum Detectable Concentration (MDC) has been demonstrated to be less than 3700 Bq/g alpha activity (100 nCi/g). Modifications were performed to update the system TMU parameters to accommodate assay of non-standard size boxes and a wider range of matrix materials. A series of calibration confirmation, measurements were performed on site in 2014 using a representative range of surrogate boxes and radioactive sources including Pu. The WIPP WAC performance criteria were successfully demonstrated up to 157 g Pu and the system passed its first Performance Demonstration Program (PDP) cycle in the Spring of 2015. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solid-state integrated real-time optical monitoring of biochemical assays

The disclosed technology includes a planar device for performing multiple biochemical assays at the same time, or nearly the same time. Each assay may include a biosample including a biochemical, enzyme, DNA, and/or any other biochemical or biological sample. Each assay may include one or more tags including dyes and/or other chemicals/reagents whose optical characteristics change based on chemical characteristics of the biological sample being tested. Each assay may be optically pumped to cause one or more of luminescence, phosphorescence, or fluorescence of the assay that may be detected by one or more optical detectors. For example, an assay may include two tags and a biosample. Each tag may be pumped by different wavelengths of light and may produce different wavelengths of light that is filtered and detected by one or more detectors. The pump wavelengths may be different from one another and different from the produced wavelengths.

Beer, N. Reginald↗

Robotic NDA of Holdup Deposits in Gaseous Diffusion Piping by Gamma Assay of Uranium-235 - 18331

This research exploits in-pipe access to develop robotically deployed, high-cadence, accurate, certain, paperless assay of U-235 in holdup deposits within process piping. Prior radiometric assay from outside the pipes suffered from manual deployment challenges, attenuation of detection through pipe walls, long counting times, approximate modeling, and shortfalls associated with transcription and human interpretation. These downsides limited the speed, quality, and economy of assay resulting in vast cost and budget consequences to D and D. D and D of outdated facilities cuts into these pipes as part of the demolition process, creating the unique, previously unexploited possibility of robotic in-pipe assay. The assay collimates radiation emanating from all but a short segment of pipe wall from reaching a gamma detector. Hence, the detector only views and measures source from a short segment of pipe at a given time. This is achieved by an innovative pair of collimating discs that are coaxial with the pipe and positioned fore and aft of the detector. The detector assembly is translated through pipes by an autonomous mobile robot. Beyond radiometric assay of U-235, the robot images and geometrically models the pipe interior and deposit appearance. The robot is recovered from the same pipe opening from which it is launched, hence it drives the same distance out and back, measuring the same deposits twice. This achieves redundant radiometric and odometric measurements which adds further to statistical significance of the method. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Use of an ISOCS-based Waste Assay System for Decommissioning Waste at Trawsfynydd - 19526

Magnox UK Ltd. are decommissioning the former Magnox nuclear power stations in the UK, a process that generates a significant amount of radioactive waste, much of it in the Low Level or Very Low Level categories. It is therefore necessary to perform radiometric assay of the decommissioning waste in order to determine the disposal route and to identify items of waste that are Out of Scope of regulatory control and can therefore be free-released. They have recently commissioned a Canberra On Site Assay System (OSAS) for this purpose. OSAS is a high-resolution gamma-ray spectrometry based waste assay system, which makes use of the ISOCS methodology in order to perform the necessary efficiency calibration of the system for use when assaying the various different containers for the decommissioning waste employed at Trawsfynydd: 210 litre drums, Dolav boxes, wheeled bins and Pac-Tec bulk bags of heavier waste. This publication describes the approach used by Magnox in the processing of the decommissioning waste at Trawsfynydd. It also presents details of the OSAS system and how it was calibrated along with the results from the proof testing of the new system, involving comparison with the results from the assay of waste previously assayed using other monitors. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improvements to In-Canal Assay of High Specific Activity 60Co at the ATR

Improvements to the quality of measurements in the assaying of High Specific Activity (HSA) cobalt 60 produced at the Advanced Test Reactor at the Idaho National Laboratory are presented. Such assays are conducted regularly between cycles at the ATR, and due to the radiological safety concerns, they are performed within the ATR canal. A standard ion chamber detector was placed in a collimated assay tube within the canal. Another tube, parallel to the detector, was used to position various cobalt 60 standards and targets. The collimated port between these tubes allows for the targets to be pulled across via a winch system. Previous measurements were performed at discrete 1.5-inch steps using a hand-cranked winch system. Charge was collected and integrated for 10 seconds at each discrete step during a scan. Two substantial improvements to the assay include an electronically controlled, motor-driven winch system and a software controlled continuous charge collection. Combined, these changes improved the quality of measurements as well as streamline the assay process. Further examination of these charge profiles indicated a reasonable amount of photon scattering, or shine, before a line-of-sight is established. This created inaccuracies in the reported activity of the cobalt targets. A series of MCNP-6.3 calculations were performed in an effort to quantify and correct for this shine effect. The results of the calculations and how they were employed to a create shine correction factor for the in-canal cobalt assay at the ATR are presented. The overall bias showed an overestimation of the HSA cobalt 60 activity by around 7-8%.

07 - ISOTOPES AND RADIATION SOURCES↗

Lead Slowing-Down Spectrometry Time Spectral Analysis for Spent Fuel Assay: FY11 Status Report

Developing a method for the accurate, direct, and independent assay of the fissile isotopes in bulk materials (such as used fuel) from next-generation domestic nuclear fuel cycles is a goal of the Office of Nuclear Energy, Fuel Cycle R&D, Material Protection and Control Technology (MPACT) Campaign. To meet this goal, MPACT supports a multi-institutional collaboration, of which PNNL is a part, to study the feasibility of Lead Slowing Down Spectroscopy (LSDS). This technique is an active nondestructive assay method that has the potential to provide independent, direct measurement of Pu and U isotopic masses in used fuel with an uncertainty considerably lower than the approximately 10% typical of today's confirmatory assay methods. This document is a progress report for FY2011 PNNL analysis and algorithm development. Progress made by PNNL in FY2011 continues to indicate the promise of LSDS analysis and algorithms applied to used fuel. PNNL developed an empirical model based on calibration of the LSDS to responses generated from well-characterized used fuel. The empirical model, which accounts for self-shielding effects using empirical basis vectors calculated from the singular value decomposition (SVD) of a matrix containing the true self-shielding functions of the used fuel assembly models. The potential for the direct and independent assay of the sum of the masses of 239Pu and 241Pu to within approximately 3% over a wide used fuel parameter space was demonstrated. Also, in FY2011, PNNL continued to develop an analytical model. Such efforts included the addition of six more non-fissile absorbers in the analytical shielding function and the non-uniformity of the neutron flux across the LSDS assay chamber. A hybrid analytical-empirical approach was developed to determine the mass of total Pu (sum of the masses of 239Pu, 240Pu, and 241Pu), which is an important quantity in safeguards. Results using this hybrid method were of approximately the same accuracy as the pure empirical approach. In addition, total Pu with much better accuracy with the hybrid approach than the pure analytical approach. In FY2012, PNNL will continue efforts to optimize its empirical model and minimize its reliance on calibration data. In addition, PNNL will continue to develop an analytical model, considering effects such as neutron-scattering in the fuel and cladding, as well as neutrons streaming through gaps between fuel pins in the fuel assembly.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SCALE Validation Experience Using an Expanded Isotopic Assay Database for Spent Nuclear Fuel

The availability of measured isotopic assay data to validate computer code predictions of spent fuel compositions applied in burnup-credit criticality calculations is an essential component for bias and uncertainty determination in safety and licensing analyses. In recent years, as many countries move closer to implementing or expanding the use of burnup credit in criticality safety for licensing, there has been growing interest in acquiring additional high-quality assay data. The well-known open sources of assay data are viewed as potentially limiting for validating depletion calculations for burnup credit due to the relatively small number of isotopes measured (primarily actinides with relatively few fission products), sometimes large measurement uncertainties, incomplete documentation, and the limited burnup and enrichment range of the fuel samples. Oak Ridge National Laboratory (ORNL) recently initiated an extensive isotopic validation study that includes most of the public data archived in the Organization for Economic Cooperation and Development/Nuclear Energy Agency (OECD/NEA) electronic database, SFCOMPO, and new datasets obtained through participation in commercial experimental programs. To date, ORNL has analyzed approximately 120 different spent fuel samples from pressurized-water reactors that span a wide enrichment and burnup range and represent a broad class of assembly designs. The validation studies, completed using SCALE 5.1, are being used to support a technical basis for expanded implementation of burnup credit for spent fuel storage facilities, and other spent fuel analyses including radiation source term, dose assessment, decay heat, and waste repository safety analyses. This paper summarizes the isotopic assay data selected for this study, presents validation results obtained with SCALE 5.1, and discusses some of the challenges and experience associated with evaluating the results. Preliminary results obtained using SCALE 6 and ENDF/B-VII cross sections libraries are also briefly summarized. Oak Ridge National Laboratory (ORNL) has been performing spent-fuel isotopic validation studies using the depletion analysis methods in the SCALE [1] code system for the past 20 years. These studies involve comparisons of calculated inventories against measured isotopic composition data obtained from destructive radiochemical analysis of commercial spent nuclear fuel samples. The results of these benchmark studies are used to quantify the bias and uncertainties associated with isotopic calculations and ultimately determine appropriate margins for uncertainty that can be applied in safety-related analyses such as burnup credit in criticality calculations, decay heat analysis, and source terms. Previous studies using several versions of SCALE and nuclear data libraries have been published in multiple validation reports [2-6] that evaluate selected experimental data obtained largely from public sources. A study was recently initiated at ORNL with the objectives of updating and expanding the validation calculations using a comprehensive database of experimental isotopic assay data that includes isotopic composition data obtained from both publicly available sources and international commercial programs. As part of the study, an extensive isotopic database of nearly 120 measured spent fuel samples with an expanded range of initial enrichments and burnup values compared to previously analyzed data was reviewed and analyzed. The calculations were performed using two-dimensional (2-D) assembly models and a consistent set of modeling assumptions using the SCALE 5.1 code system and ENDF/B-V 44-group cross section library. As part of the current study, detailed benchmark modeling information and measurement data are being documented in a format that is readily usable for validating depletion and decay codes. The work is being extended to include analysis results using SCALE 6 and the ENDF/B-VII 238-group cross section library. This paper describes the isotopic composition data evaluated in this study and highlights the preliminary findings to date.

07 ISOTOPE AND RADIATION SOURCES↗

Automated Nondestructive Assay of UF6 Cylinders: Detector Characterization and Initial Measurements

International Atomic Energy Agency (IAEA) inspectors currently perform periodic inspections at uranium enrichment plants to verify UF6 cylinder enrichment declarations. Measurements are typically performed with handheld high-resolution sensors on a sampling of cylinders assumed to be representative of the facility's entire cylinder inventory. These measurements are time-consuming and assay only a small fraction of the total cylinder volume. An automated nondestructive assay system capable of providing enrichment measurements over the full volume of the cylinder could improve upon current verification practices in terms of manpower and assay accuracy. Pacific Northwest National Laboratory is developing an Integrated Cylinder Verification System (ICVS) intended for this purpose and has developed a field prototype of the nondestructive assay (NDA) components of an ICVS. The nondestructive assay methods would combine the 'traditional' enrichment-meter signature (i.e. 186-keV emission from 235U) as well as 'non-traditional' high-energy photon signatures derived from neutrons produced primarily by 19F({alpha},n) reactions. This paper describes the design, calibration and characterization of the NaI(Tl) and LaBr3(Ce) spectrometers utilized in the field prototype. An overview of a recent field measurement campaign is then provided, supported by example gamma-ray pulse-height spectra collected on cylinders of known enrichment.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗