Search NASA⌕ Search

SEARCH · Search NASA

Results for “Augustine”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

MARS 2020 Backshell Radiative Heating Measurement and Shock Tube Verification

In February 2021, the Perseverance rover was brought to the surface of Mars by the Mars 2020 mission. A feature of the Mars 2020 capsule was instrumentation to measure its entry, descent and landing (EDL) with the so-called Mars EDL Instrumentation 2 (MEDLI2) [1]. The MEDLI2 introduced, among other things, backshell instrumentation, including a broadband radiometer. The radiometer was mounted on the leeside of the vehicle next to thermocouple plugs and a heat flux gauge. The data returned by the leeside MEDLI2 heat flux gauge is largely analogous to that measured by the COMARS gauge flown on the ExoMars Schiaparelli [2] entry in that it is measuring heat flux in an area that is entirely dominated by radiative heating. The COMARS measurement provided excellent validation of backshell radiative heating models for Mars entry, albeit at a limited number of points [3]. The MEDLI2 heat flux gauge measurement effectively confirmed the quality of the prediction, extended over the full trajectory, as will be presented in this paper. The MEDLI2 radiometer,however, was blocked by ablation products and suffered a loss of half of its signal. The second backshell heat flux gauge installed on the windside of the vehicle was also well predicted, although the heating had both radiative and convective contributions. It was desired to reproduce the conditions of the Mars 2020 entry via ground testing in the Electric Arc Shock Tube (EAST) at NASA Ames. Tests to verify stagnation line heating were previously reported in EAST, confirming the presence of shock layer radiation as the major discrepancy in heatshield temperature modelling [4]. Therefore, tests for stagnation line heating were not repeated. Instead, the shock tube informed bias method [5, 6] was used to identify test conditions that may produce similarity to streamlines that pass around the backside of the vehicle and are responsible for the radiation observed at the two heat flux gauge locations. This method was used to identify a range of velocities and densities in the shock tube that are relevant for confirming the radiative environment encountered. This paper reports the results obtained in the 10 cm diameter EAST shock tube, corresponding to later trajectory points at ambient pressures of 1.1-2.0 Torr and velocities from 1.2-3.5 km/s. The test series employed two primary diagnostics: emission spectroscopy and tunable diode laser absorption spectroscopy (TDLAS). The emission spectroscopy performed broadband measurements of the radiative emission of the 4.3 and 2.7 m bands of CO2 at flight similar conditions, obtaining both spectral and spatial data corresponding to the relaxation behind the shock front. The TDLAS measured the absorption of several lines of CO and CO2 and obtains species number densities and temperatures as a function of time behind the shock front. This paper will review highlights of this test series and analyses of the emission and absorption data. While the datasets generally show good agreement with predictions, a few discrepancies and items for additional investigation are identified and will be discussed

Brett A Cruden↗

Analysis of the Value Added When Deploying a Model-Based Approach for the Validation and Verification of the Medical Database Software

The Medical Database (MD) is a virtual repository consisting of two software components: Medical Item Database (MedID) and the Evidence Library (EL). MedID consists of engineering data and associated information for specific medical resource items (e.g., pharmaceutical, medical devices, and supporting components), while the EL is a tool which provides all of the medical evidence necessary. The MD will 1) serve as the single “source of truth” for the Informing Mission Planning via Analysis of Complex Tradespaces (IMPACT) tool suite for both medical evidence and medical resource engineering data and 2) will be used in conjunction with the IMPACT tool suite to inform research prioritizations and perform systematic trade study evaluations to aid stakeholders in making informed decisions regarding simulated human spaceflight missions. The MD project used a Model-Based Systems Engineering (MBSE) approach to support all life cycles of the software development, while in parallel the human factors engineering team used modeling to support Human Centered Design (HCD) strategies in an effort to improve software usability. HCD is a frequently used approach in design frameworks that develops resolutions to complexities and challenges by involving the human perspective in all steps of the problem-solving process. By integrating the model-based approaches used for systems engineering and human factors activities, the project is able to leverage the model-based artifacts originally created for HCD activities for system level and human factors validation. In this presentation, our team highlights the value added when leveraging these model-based artifacts to support the on-going verification and validation activities.

C. Laing↗

Examination of Mars2020 Shock-Layer Conditions via Infrared Laser Absorption Spectroscopy of CO2 and CO

Amid-infrared laser absorption diagnostic was deployed to study a simulated Mars2020 shock layer in the Electric Arc Shock Tube (EAST) facility at NASA’s Ames Research Center. Rapid RF-diplexing techniques enabled quantitative temperature and number density measurements of CO2 and CO with μs-resolution over an incident shock velocity range of 1.39 – 3.75 km/s. Two interband cascade lasers were utilized at 4.17 and 4.19 μm to resolve eight CO2 asymmetric stretch fundamental band (𝜈3) transitions from two different vibrational levels: 0000 (ground state) and 0110 (first excited bending mode). The probed rotational levels span across J” = 58 to J” = 140. Results are compared to DPLR simulations of the shock layer using kinetic mechanisms of Johnston et al. and Cruden et al. At shock velocities below 3.1 km/s, the agreement between the measurements and the Johnston mechanism is typically within 5% for temperature and within 10% for number density. At shock velocities above 3.1 km/s, the CO2 measurement becomes sensitive to a thin boundary layer and corrections of this effect are presented. On test cases with enough energy to dissociate CO2, a quantum cascade laser scanned the P(2, 20), P(0, 31), and P(3, 14) transitions of the CO fundamental band at 4.98 μm. CO formation rate is measured to be close to the Johnston kinetic mechanism at low velocities, and then trending towards the Cruden kinetic mechanism at high velocities. On a few low velocity test cases, rovibrational relaxation of the Martian atmosphere is probed with μs resolution.

Laser Absorption↗

Examination of Mars2020 Shock-Layer Conditions Via Infrared Emission Spectroscopy of CO2

A new test series was performed in the Electric Arc Shock Tube (EAST) facility, with the aim of reproducing flight conditions encountered during the Mars2020 mission entry into Mars atmosphere. For this test series, the EAST facility was instrumented with two spectrometers for Optical Emission Spectroscopy (OES) measurements and three mid-infrared lasers for Tunable Diode Laser Absorption Spectroscopy (TDLAS). This study focuses on the spectrally and spatially resolved radiance measured with OES. Comparison with CEA/NEQAIR and DPLR/NEQAIR simulations were made. For velocity above 2.7 km/s, measurements are found to lie between the different tested kinetic models, within ± 10%. Below 2.7 km/s, the chemistry appears to be frozen and measured radiance profiles are typically 10% above CEA predictions. This difference is explained by shock deceleration effects. Finally, comparison between OES and TDLAS data are made and show a good agreement on the measured temperature and CO2 number density profiles using the two diagnostics, typically within 10 and 5%, respectively.

Augustin C Tibere-Inglesse↗

Laser Absorption Spectroscopy Measurements of Post-Shock Non-Equilibrium Species in the NASA Ames Electric Arc Shock Tube

The NASA Ames Electric Arc Shock Tube (EAST) is a unique facility capable of generating high enthalpy, shock-heated impulse gas flows representative of the kinetic and radiative conditions encountered by atmospheric entry vehicles. The facility maintains a successful history with emission spectroscopy, providing measurements of absolute radiance upon which various validation studies are anchored. The central objective of this work is to develop a comprehensive tunable diode laser absorption spectroscopy (TDLAS) sensing capability to provide complementary experimental insights to existing emission techniques. More specifically, a fast-scanning TDLAS-based diagnostic targeting the cyano radical (CN) in the near-infrared(near-IR) near 926.6 nm is employed in mixtures of 2.2% CH4in N2by mole for a sweep of incident shock velocities ranging 3.0-5.5 km/s and fill pressures 0.3-1.15 Torr. Laser scan rates up to 500 kHz probe multiple absorption features to provide quantitative measurements of temperature and species number density profiles behind the incident shock. In all instances, the temperature trend is consistent between emission-inferred and TDLAS-inferred measurements. However, at the lower-velocity conditions, there is an appreciable offset between the Data Parallel Line Relaxation Code (DPLR) simulation and experimental measurements. A similar behavior is observed in number density profiles, with emission measurements providing inferences of the CN(B) and CN(A) state, while TDLAS measurements provide an additional inference of the CN(X) state. In the fast-scanned experiments, measurement inferred number densities suggest a much faster production of CN at early times than captured by the model. This discrepancy motivates ongoing, additional spectroscopic and kinetics CN experiments to resolve the accuracy of modeling assumptions.

Efaine Chang↗

Examination of Mars2020 Shock-Layer Conditions Via Infrared Emission Spectroscopy of CO2

A new test series was performed in the Electric Arc Shock Tube (EAST) facility, with the aim of reproducing flight conditions encountered during the Mars2020 mission entry into Mars atmosphere. For this test series, the EAST facility was instrumented with two spectrometers for Optical Emission Spectroscopy (OES) measurements and three mid-infrared lasers for Tunable Diode Laser Absorption Spectroscopy (TDLAS). This study focuses on the spectrally and spatially resolved radiance measured with OES. Comparison with CEA/NEQAIR and DPLR/NEQAIR simulations were made. For velocity above 2.7 km/s, measurements are found to lie between the different tested kinetic models, within ± 10%. Below 2.7 km/s, the chemistry appears to be frozen and measured radiance profiles are typically 10% above CEA predictions. This difference is explained by shock deceleration effects. Finally, comparison between OES and TDLAS data are made and show a good agreement on the measured temperature and CO2 number density profiles using the two diagnostics, typically within 10 and 5%, respectively.

Augustin Tibère-Inglesse↗

Overview of NASA Research Activities in Shock Layer Kinetics and Radiation

Shock layer radiation is an important heating mechanism for entry probes to most planetary destinations and re-entry to Earth from beyond low Earth orbit. Our understanding of shock layer radiation phenomena has improved tremendously over the last decade thanks to NASA investment in fundamental radiation research through Entry Systems Modeling’s (ESM) Shock Layer Kinetics and Radiation (SLKR) task. This talk will overview the recent activities within SLKR, including validation of models through ground testing, flight instrumentation and remote observations; development of first principles ab initio calculations for reaction mechanisms and spectroscopic databases and advancing numerical and computational methods for prediction of radiation in reacting hypersonic flows. 1 Sr. Research Scientist, Aerothermodynamics Branch, and AIAA Associate Fellow.

Brett A. Cruden↗

Ni-Silicide Schottky Barrier Micropyramidal Photodetector Array

In attempt to increase the quantum yield of metal/silicide Schottky barrier photodetectors, in this work we fabricated and tested Si micropyramidal arrays which are capable to resonantly trap photons in the photodetector areas. To simplify testing, Ni/silicide Schottky barrier photodetectors were formed on the entire 1.5  1.5 mm areas occupied by the micropyramidal arrays. Preliminary testing results revealed potentially stronger photoresponse of micropiramids with narrow tops, but further studies are required to compare the performance of such novel photodetector arrays with different geometrical parameters of micropyramids.

Astratov, Vasily N.↗

Anisotropic Wet Etching of Si as a Fabrication Tool Enabling 3-D Microphotonics Structures and Devices

It is shown that due to high speed and large volume of production, anisotropic wet etching of Si is a unique method of manufacturing high quality micropyramidal arrays for silicon photonics. Four types of arrays were fabricated: (i) square pyramids with the 54.7 slope of the sidewall surface, (ii) microcones with the 45 slope of sidewall surface, (iii) inverted square pyramids with 54.7 slope, and (iv) inverted triangular pyramids with different angles of the sidewalls. It is shown that the first type of arrays has a capability to produce tightly focused mid-wave infrared (MWIR) beams at the tips of the pyramids. Other arrays can be also used as light concentrators and various multifunctional microphotonic components.

Astratov, Vasily N.↗

Light-concentrating microcone array for improving performance of infrared imaging devices

Light-harvesting low-index (n=1.6) microconical arrays are proposed for increasing the sensitivity and the signal-to-noise ratio (SNR) of mid-wave infrared (MWIR) focal plane arrays (FPAs) used in thermal cameras. Numerical modeling showed a 3-D Power enhancement factor ~ 50 in MWIR for 10° tapered microcones with Dt/Db = 60 μm/8μm and h=150μm, where Dt and Db are the top and bottom diameters of microcones, respectively. Such microconical arrays were fabricated in photoresist by using a nanoscribe tool directly on top of the front-illuminated Ni/Si Schottky-barrier, and three-fold enhancement in the photocurrent response was observed. The proposed approach permits increase of the SNR and the operation temperature of the MWIR imaging devices.

Astratov, Vasily N.↗

Backshell Radiation Measurements in the EAST Facility for Titan Entry

A new test series was performed in the Electric Arc Shock Tube (EAST) facility, with the aim of reproducing conditions which will be encountered in the backshell of the Dragonfly spacecraft. Measurements of shock-layer radiation from CN Violet, CN Red and C 2 Swan bands are made in mixtures of 2.2% CH 4 in N 2 (by mole) heated by incident shock waves spanning from 3 to 7 km/s. This study focuses on the spectrally and spatially resolved measurement of absolute radiance made with four optical emission spectrometers spanning 220-1400 nm. Comparison with CFD simulations and equilibrium conditions were made. The predicted radiation was found to be between -40% to 100% from the measurements for the nonequilibrium peak radiance, increasing with velocity. At 7 cm/150 μs from the shock front, the discrepancies appear to be larger, ranging from -50 to 200%. Comparison between measured and predicted temperatures and number densities of CN indicate shortcomings in the non-Boltzmann model of CN.

Augustin Tibere-Inglesse↗

Backshell Radiation Measurements in the EAST Facility for Titan Entry

A new test series was performed in the Electric Arc Shock Tube (EAST) facility, with the aim of reproducing conditions which will be encountered in the backshell of the Dragonfly spacecraft. Measurements of shock-layer radiation from CN Violet, CN Red and C 2 Swan bands are made in mixtures of 2.2% CH 4 in N 2 (by mole) heated by incident shock waves spanning from 3 to 7 km/s. This study focuses on the spectrally and spatially resolved measurement of absolute radiance made with four optical emission spectrometers spanning 220-1400 nm. Comparison with CFD simulations and equilibrium conditions were made. The predicted radiation was found to be between -40% to 100% from the measurements for the nonequilibrium peak radiance, increasing with velocity. At 7 cm/150 μs from the shock front, the discrepancies appear to be larger, ranging from -50 to 200%. Comparison between measured and predicted temperatures and number densities of CN indicate shortcomings in the non-Boltzmann model of CN.

Augustin Tibere-Inglesse↗

Backshell Radiative Heating and Shock Layer Kinetic Measurement in NASA’s Electric Arc Shock Tube Facility

A methodology for creating incident shocks with similarity to the backshell radiative heating environment on planetary probes is presented. Two test series were carried out in the Electric Arc Shock Tube (EAST) at NASA Ames to quantify the backshell environment for planned and executed missions entering the atmospheres of Mars and Titan. The comparison of measured radiance in the shock tube to predicted post shock radiation levels is used to quantify the uncertainty in the model. This model uncertainty may then be related back to the flight condition to assess the error in the flight heating prediction. Tests for Mars entry show the shock tube measurements to be bracketed between two kinetic models by 2-7%. This suggests an 8% error in predicting the measured heating cannot be attributed to radiation. Comparisons to planned Titan entry suggest a substantial overprediction of the backshell radiation, which suggests opportunity for future refinement of radiative heating models.

radiation↗

Crew Health and Performance Integrated Data Architecture Project Updates

Future Human Exploration missions will face new constraints as crews move further from terrestrial communication, resupply, and the real-time support enjoyed by Low Earth Orbit missions today. Exploration crews will need to be more self-reliant and able to respond to emergencies without immediate support from ground-based personnel. A new generation of technologies, employing advanced analytical and predictive modeling techniques, is needed to assist the crew’s work, help maintain their health, and inform the decisions they make on these future Exploration missions. The Crew Health and Performance Integrated Data Architecture (CHP-IDA) project is laying a foundation for these future technologies by integrating sources of data generated by and around the crew and then providing them though common data models and Application Programming Interfaces to external systems. The combined data model makes comprehensive Crew Health and Performance data accessible and more meaningful to the decision-making process. This presentation will describe the currently ongoing effort to develop and evaluate a path-to-flight concept of the CHP-IDA software, current integrations, updates to the architecture, and examples of exploration scenarios in which CHP-IDA would be used.

B Schmitt↗

Impact of Trace CH 4 on Shock Layer Radiation in Outer Planet Entry

This paper reports experimental characterization of shock layer radiation from H 2 /He mixtures with a small amount of methane (CH 4 ) addition in the Electric Arc Shock Tube at NASA Ames Research Center. The work follows on a previous test series for entry probes to Saturn and Uranus, which quantified the expected radiance in the absence of methane. However, the Saturn stratosphere is estimated to have approximately 0.4% of CH 4 . The current test series utilized mixtures of 0.886/0.110/0.004 H 2 /He/CH 4 (by mole.) Freestream pressures included 0.1 and 0.5 Torr and velocities from 15-26 km/s. Data compares favorably to similar conditions collected in the Oxford T6 facility. Additional radiation features attributable to CH and C 2 Swan bands are observed, albeit at low intensities. Comparisons to data collected in previous EAST tests suggest that the CH 4 does not significantly alter reaction kinetics below 26 km/s.

Radiation↗

Crew Health and Performance Integrated Data Architecture Project Update

Future Human Exploration missions will face new constraints as crews move further from terrestrial communication, resupply, and the real-time support enjoyed by Low Earth Orbit missions today. Exploration crews will need to be more self-reliant and able to respond to emergencies without immediate support from ground-based personnel. A new generation of technologies, employing advanced analytical and predictive modeling techniques, is needed to assist the crew’s work, help maintain their health, and inform the decisions they make on these future Exploration missions. The Crew Health and Performance Integrated Data Architecture (CHP-IDA) project is laying a foundation for these future technologies by integrating sources of data generated by and around the crew then providing them though common data models and Application Programming Interfaces to external systems. The combined data model makes comprehensive Crew Health and Performance data accessible and more meaningful to the decision-making process. This presentation will describe the currently ongoing effort to develop a path-to-flight concept of the CHP-IDA software, current integrations that have been developed, updates to the architecture, and examples of the corresponding exploration scenarios in which CHP-IDA would be used.

Exploration↗