Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAMS, RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Young Adult Populations Face Yet Another Barrier to Care With Insurers: Limited Access to Proton Therapy

Young patients, including pediatric, adolescent, and young adult (YA) patients, are most likely to benefit from the reduced integral dose of proton beam radiation therapy (PBT) resulting in fewer late toxicities and secondary malignancies. This study sought to examine insurance approval and appeal outcomes for PBT among YA patients compared with pediatric patients at a large-volume proton therapy center.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patch Antenna Fed via Unequal-Crossed-Arm Aperture

A proposed rectangular-patch antenna for transmitting or receiving microwave circularly polarized (CP) radiation would be fed via a cross-shaped aperture that would have unequal arms and would, in turn, be fed at a single point via a microstrip transmission line. As a consequence of the unequal-arm aperture design, the antenna could be made smaller in one dimension, relative to a typical prior CP antenna that comprises a nearly square patch fed via an equal-crossed-arm aperture. Hence, in designing a phased array of such antennas, the antennas could be packed together more closely along one dimension, making it possible to scan the beam radiated by the antenna over a wider angular range in a plane that includes that dimension. Alternatively or in addition, one could lay out transmission lines in the extra spaces created by the shortening in one dimension

Epp, Larry↗

Dual-Frequency Airborne Scanning Rain Radar Antenna System

A compact, dual-frequency, dual-polarization, wide-angle-scanning antenna system has been developed as part of an airborne instrument for measuring rainfall. This system is an upgraded version of a prior single-frequency airborne rain radar antenna system and was designed to satisfy stringent requirements. One particularly stringent combination of requirements is to generate two dual-polarization (horizontal and vertical polarizations) beams at both frequencies (13.405 and 35.605 GHz) in such a way that the beams radiated from the antenna point in the same direction, have 3-dB angular widths that match within 25 percent, and have low sidelobe levels over a wide scan angle at each polarization-and-frequency combination. In addition, the system is required to exhibit low voltage standing-wave ratios at both frequencies. The system (see figure) includes a flat elliptical scanning reflector and a stationary offset paraboloidal reflector illuminated by a common-aperture feed system that comprises a corrugated horn with four input ports one port for each of the four frequency-and-polarization combinations. The feed horn is designed to simultaneously (1) under-illuminate the reflectors 35.605 GHz and (2) illuminate the reflectors with a 15-dB edge taper at 13.405 GHz. The scanning mirror is rotated in azimuth to scan the antenna beam over an angular range of 20 in the cross-track direction for wide swath coverage, and in elevation to compensate for the motion of the aircraft. The design of common-aperture feed horn makes it possible to obtain the required absolute gain and low side-lobe levels in wide-angle beam scanning. The combination of the common-aperture feed horn with the small (0.3) focal-length-to-diameter ratio of the paraboloidal reflector makes it possible for the overall system to be compact enough that it can be mounted on a DC-8 airplane.

Hussein, Ziad A.↗

Characteristics and radiolysis behavior of polyvinylchloride under accelerated proton and γ-irradiation

Here the effect of high energy protons and γ-irradiation on the structural properties, surface-energies, and toxicological properties of polyvinyl chloride (PVC) were studied due to the role PVC products play in many technologies including the nuclear industry. Accelerated 1–4 MeV protons impacting on PVC in vacuum lead to the formation of polyenyl radicals as shown by EPR and to an increase in free surface energy due to functionalization of the surface of the irradiated polymer. γ-irradiation leads to the formation of unsaturated bonds, carbonyl and hydroxyl groups as shown by IR and to the release of HCl. Correlated molecular orbital theory calculations of reaction thermodynamics were used to aid in the development of a mechanism in the absence of oxygen. The formation and accumulation of chromophores and auxochromic groups during γ-radiolysis of PVC leads to a gradual change of the initial white color of the polymer to yellow and then to brown and black with high sensitivity. A mixture of powdered PVC and silicate glue was used to determine the profile of a 60 Co γ-radiation beam on targets with a complex relief. γ-irradiated polymer does not have a local irritating effect due to a single application to the skin of mice in an adhesive mixture at a concentration of up to 5000 mg/kg. γ-radiolysis of PVC powder in air with a dose of up to 1400 kGy does not affect its acute toxicity when administered intragastrically to BDF1 mice. PVC and its γ-irradiated analogs are non-toxic at doses ≤5000 mg/kg.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Correlative nano-imaging of metals and proteins in primary neurons by synchrotron X-ray fluorescence and STED super resolution microscopy: Experimental validation

It is becoming increasingly clear that biological metals such as iron, copper or zinc are involved in synaptic functions, and in particular in the mechanisms of synaptogenesis and subsequent plasticity. Understanding the role of metals on synaptic functions is a difficult challenge due to the very low concentration of these elements in neurons and to the submicrometer size of synaptic compartments. To address this challenge we have developed a correlative nano-imaging approach combining metal and protein detection. First, stimulated emission depletion (STED) microscopy, a super resolution optical microscopy technique, is applied to locate fluorescently labeled proteins. Then, synchrotron radiation induced X-ray fluorescence (SXRF) is performed on the same regions of interest, e.g. synaptic compartments. Here, we present here the principle scheme that allows this correlative nano-imaging and its experimental validation. We applied this correlative nano-imaging to the study of the physiological distribution of metals in synaptic compartments of primary rat hippocampal neurons. We thus compared the nanometric distribution of metals with that of synaptic proteins, such as PSD95 or cytoskeleton proteins. Compared to correlative imaging approaches currently used to characterize synaptic structures, such as electron microscopy correlated with optical fluorescence, our approach allows for ultra-sensitive detection of trace metals using highly focused synchrotron radiation beams. We provide proof-of-principle for correlative imaging of metals and proteins at the synaptic scale and discuss the present limitations and future developments in this area.

59 BASIC BIOLOGICAL SCIENCES↗

Statistical Analysis of Trans‐Ionospheric Pulse Pairs and Inferences on Their Characteristics

Trans-ionospheric pulse pairs (TIPPs), first observed in 1993, are signatures of in-cloud lightning discharges observed by satellite-based broadband very high frequency (VHF) receivers. It has been definitively shown that TIPPs are the space-based signatures of compact intracloud discharges (CIDs), and that the associated pair of pulses that comprise a TIPP result from the direct VHF pulse from the discharge, followed by a pulse reflected from the Earth's surface. However, the ratio of the peak amplitudes of these two pulses can vary widely, with the second pulse often having considerably higher peak amplitude than the first. This observation has not been satisfactorily explained. Using data collected from geostationary orbit by the Radio Frequency Sensor (RFS) and matched to locations reported by the Global Lightning Dataset (GLD360), we assemble the largest database to date of 76,348 TIPPs with associated location, altitude, and amplitude ratio of the two pulses in the TIPP. We show that the amplitude ratio of TIPPs is strongly correlated to the altitude of the associated discharges and the geometry of the source location with respect to the Earth's surface and the receiver. These observations strongly suggest that the difference in amplitude of the two pulses is driven by a nondipole radiated beam pattern that is dependent on the polarity of the CID, velocity of the current wavefront, and viewing angle.

58 GEOSCIENCES↗

Performance demonstration of vacuum microwave components critical for the operation of the ITER low-field side reflectometer

Final design studies in preparation for manufacturing have been performed for functional components of the vacuum portion of the ITER Low-Field Side Reflectometer (LFSR). These components consist of an antenna array, electron cyclotron heating (ECH) protection mirrors, phase calibration mirrors, and vacuum windows. Evaluation of these components was conducted at the LFSR test facility and DIII-D. The antenna array consists of six corrugated-waveguide antennas for simultaneous profile, fluctuation, and Doppler measurements. A diffraction grating, incorporated into the plasma-facing miter bend, provides protection of sensitive components from stray ECH at 170 GHz. For in situ phase calibration of the LFSR profile reflectometer, an embossed mirror is incorporated into the adjacent miter bend. Measurements of the radiated beam profile indicate that these components have a small, acceptable effect on mode conversion and beam quality. Baseline transmission characteristics of the dual-disk vacuum window are obtained and are used to guide ongoing developments. Preliminary simulations indicate that a surface-relief structure on the window surfaces can greatly improve transmission. The workability of real-time phase measurements was demonstrated on the DIII-D profile reflectometer. The new automated real-time analysis agrees well with the standard post-processing routine.

47 OTHER INSTRUMENTATION↗

Local measurements of the pedestal magnetic field profile throughout the ELM cycle on DIII-D

We report new high speed localized measurements of the pedestal magnetic field during the edge localized mode (ELM) cycle of a DIII-D High confinement mode (H-mode) discharge indicate a temporally and spatial complex redistribution of the edge current density profile, $j_{edge}$. The measurement technique extracts the magnetic field magnitude, $\textit{B}$, via the spectral separation of Stark-split neutral beam radiation in the pedestal. Single spatial channel measurements from a novel spatial heterodyne spectrometer are validated in discharges with core current profile changes. The technique measures Stark-splitting changes that imply $\textit{B}$ changes as small as 1 mT with high time resolution (50 μs). At normalized poloidal flux $ψ_n$ = 1.0, $\textit{B}$ appears saturated in the inter-ELM period and then rapidly decreases in <200 μs by ~1%, before edge recycling emission begins to increase. Radially inboard of $j_{edge}$, $\textit{B}$ increases at the ELM crash. The behavior is consistent with a rapid collapse of $j_{edge}$ at the ELM crash and subsequent pedestal recovery. In some discharges, at $ψ_n$ < 0.96, changes in $\textit{B}$ are observed throughout the ELM cycle. In others, $\textit{B}$ recovers and is relatively stable until a few ms leading up to the next crash. Measurements of $\textit{B}$ during the H-mode transition show a large increase at $ψ_n$ = 1 with little change at $ψ_n$ = 0.9, consistent with the formation of the edge bootstrap current density peak. The $ψ_n$ = 0.9 spectrum is complicated by predicted changes to the Stark component intensities with density at the L–H transition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatial heterodyne spectroscopy for fast local magnetic field measurements of magnetized fusion plasmas

A novel spectroscopy diagnostic for measuring internal magnetic fields in high temperature magnetized plasmas has been developed. It involves spectrally resolving the Balmer- α (656 nm) neutral beam radiation split by the motional Stark effect with a spatial heterodyne spectrometer (SHS). The unique combination of high optical throughput (3.7 mm 2 sr) and spectral resolution (δλ ~ 0.1 nm) allows these measurements to be made with time resolution $\ll$1 ms. The high throughput is effectively utilized by incorporating a novel geometric Doppler broadening compensation technique in the spectrometer. The technique significantly reduces the spectral resolution penalty inherent to using large area, high-throughput optics while still collecting the large photon flux provided by such optics. In this work, fluxes of order 10 10 s –1 support the measurement of deviations of <5 mT (Δ λ Stark ~ 10 –4 nm) in the local magnetic field with 50 µs time resolution. Example high time resolution measurements of the pedestal magnetic field throughout the ELM cycle of a DIII-D tokamak plasma are presented. Local magnetic field measurements give access to the dynamics of the edge current density, which is essential to understanding stability limits, edge localized mode generation and suppression, and predicting performance of H-mode tokamaks.

47 OTHER INSTRUMENTATION↗

Power loss analysis for the optical cavity of an x-ray laser oscillator

We investigate properties of optical elements in the optical cavity of an x-ray laser oscillator with emphasis on the power loss of a monochromatic Gaussian radiation beam upon passing through them using analytical and numerical approaches. Here we assume the optical cavity comprises of refractive lenses and Bragg crystals exploiting symmetric Bragg scattering. For the lens, we include focusing and curvature effects while we include angular filtering due to finite Darwin width of the Bragg crystal. Our results indicate the feasibility of x-ray power out-coupling in the range of 0.5%–28% with intracavity reflectivity of 67%–95% at 10.321 keV for nominal (≥ 65% reflectivity) cases. We also show the possibility of achieving high out-coupling of 35%–80% while restricting the intracavity reflectivity in the 19%–62% by adopting lossy cavities with 10–20 μ⁢m thin crystals.

36 MATERIALS SCIENCE↗

Nonlinear self-focusing in strongly magnetized pair plasma

An intense radiation field can modify plasma properties and the corresponding refractive index and lead to nonlinear propagation effects such as self-focusing. In this work, we estimate the corresponding effects in pair plasmas for circularly polarized waves, in both unmagnetized and strongly magnetically dominated cases. First, in the unmagnetized pair plasma the ponderomotive force does not lead to charge separation but to density depletion. Second, for astrophysically relevant plasmas of pulsar magnetospheres [and possible loci of fast radio bursts (FRBs)], where the cyclotron frequency $ω_B$ dominates over the plasma frequency $ω_p$ and the frequency of the electromagnetic wave $ω_B \gg ω_p, ω$, we show that (i) there is virtually no nonlinearity due to changing effective mass in the field of the wave; (ii) the ponderomotive force is $F^{(B)}_p = –m_ec^2/4B^2_0∇E^2$, which is reduced by a factor $(ω/ω_B)^2$ if compared to the unmagnetized case ($B_0$ is the external magnetic field and $\textit{E}$ is the electric field of the wave); and (iii) for a radiation beam propagating along a constant magnetic field in the pair plasma with density $n_±$, the ponderomotive force leads to the appearance of circular currents that lead to a decrease of the field within the beam by a factor $ΔB/B_0 = 2πn_±m_ec^2E^2 /B^4_0$. Applications to the physics of FRBs are discussed; we conclude that for the parameters of FRBs, the dominant magnetic field completely suppresses nonlinear self-focusing or filamentation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Beamline for E-beam processing at UITF

Electron beam irradiation is a method that has shown a good potential to reduce several pollutants in wastewater. One of the main challenges towards wider adoption of this method is the need for compact, reliable, cost-effective, high-power accelerators. Jefferson Lab is working on the design and prototyping of accelerator components, based on superconducting radio-frequency (SRF) technology, aiming at accelerators for industrial applications. The LDRD project aimed at designing, procuring, installing, and commissioning a beamline at the Upgraded Injector Test Facility (UITF) accelerator to allow electron-beam irradiation studies of different materials, beginning with wastewater. The availability of such beamline allows exploring the ability of electron-beam radiation to reduce or eliminate so-called “forever chemicals” that can be found in wastewater or industrial sites. After successful commissioning, the beamline was used to irradiate wastewater samples with different concentrations of 1,4-dioxane, in collaboration with Hampton Roads Sanitation District (HRSD).

42 ENGINEERING↗

Electron Beam Treatment of Ballast Water

Members from the Great Waters Research Collaborative (GWRC), a project of the University of Wisconsin-Superior (UWS) Lake Superior Research Institute (LSRI), will be bringing two water types to simulate the electron beam removal process for ballast waters. These two types are named low challenge and high challenge. The Low Challenge water is highly transparent water with very low concentration of total suspended solids and dissolved organic carbon. The High Challenge water is like Duluth-Superior Harbor water with low transparency and higher concentration of total suspended solids and dissolved organic carbon. Both water types will undergo a series of applied electron beam radiations and analysis to meet ballast water discharge standards. For the analysis there are standard test organisms that will be evaluated for mortality. Heterotrophic bacteria (E. coli) along with Selenastrum capricornutum will be used and then Eucyclops spp. (or Hyalella azteca) and Daphnia magna will also be evaluated.

43 PARTICLE ACCELERATORS↗

Power loss analysis for optical cavity of X-ray free-electron laser oscillator at 10 KeV

We investigate properties of optical elements in the optical cavity of an X-ray free electron laser oscillator with emphasis on power loss of a monochromatic Gaussian radiation beam upon passing through them using analytical and numerical approaches. Here we assume the optical cavity comprises of refractive lenses and Bragg crystals exploiting symmetric Bragg scattering. For lens, we include the focusing and curvature effects while we include the angular filtering due to finite Darwin width of Bragg crystals. Our results indicate feasibility of Xray power outcoupling in the range of 0.5-28 % with intra-cavity reflectivity of 67-95 % at 10.321 KeV.

43 PARTICLE ACCELERATORS↗

Absorption cell - A modified multiple-traversal device

A modified White-type multiple-transversal absorption cell used with a 5-m Littrow spectrometer is described. It can be introduced at a focus of the radiation beam without altering the beam configuration. The conventional White cell consists of three mirrors of equal focal length, with a distance of two focal lengths separating one of the mirrors from a mirror pair. The modification in the design consists of the addition of two mirrors at a slant placed behind the solitary mirror of the conventional configuration. The mirror arrangement reproduces the configuration of the exit beam for any number of transversals of the cell.

Jennings, D. E.↗