Collection of Aerosol Particles in a Single-Stage, High Gradient Magnetic Collector

The collection of aerosol particles that have magnetic components such as actinides, Co/Ni/Fe, brass, and alloys are of interest in the nuclear industry and for regulatory applications. The collection of these particles is important for monitoring and a number of collection approaches have been developed based on separations mechanisms including size, mass, electrical or thermal properties. In this work, we present the performance of a single-stage, high gradient magnetic collector with a nickel foam matrix for removing airborne magnetic particles. The collection efficiencies for two different particle size regimes and compositions (NaCl and Fe 3 O 4 below 200 nm and SiO 2 and Fe 3 O 4 at 1-2 μm) were measured to assess the performance of the magnetic collector. The high gradient magnetic collector did not remove nanosized magnetic Fe 3 O 4 particles any more effectively than non-magnetic NaCl particles. However, in the larger size range, the collector more efficiently removed Fe 3 O 4 particles compared to SiO 2 with a collection efficiency of 99% compared to 84% for SiO 2 . The removal mechanism could be attributed to both filtration and the high gradient magnetic field.

54 ENVIRONMENTAL SCIENCES↗

High-Silicon Steel Strip by Single-Step Shear Deformation Processing

It is well known that Fe-Si alloys with Si content higher than in conventional electrical sheet steels (>3.2% Si) can make a significant impact in improving the efficiency of electrical motors if they are available in sheet/foil (strip) forms at suitable cost. While the magnetic and electrical attributes (e.g., resistivity, core loss) of these high-Si Fe alloys, of relevance to electrical motor core laminations, are known to be exceptional, the alloys have limited workability, making them difficult to produce consistently in sheet/foil (strip) forms. Current processing techniques such as rolling, while adequate for producing conventional electrical steel sheet, do have important disadvantages - large energy consumption and emissions, limitations in processing of low-workability alloys (e.g., high-Si content steels), large-scale plant infrastructure, and less than adequate capability to engineer sheet metals with specific microstructures (e.g., fine-grained) and crystallographic textures (e.g., shear textures). It is therefore of interest to have an alternative commercial process that can produce sheet/foil (strip) from high-Si Fe alloys and which can also overcome some of the deficiencies of current multistage strip processes. The goal of the present project was design and demonstration of a new energy-efficient pilot process for producing high-Si electrical steel strip of commercial widths and thickness, and with superior electrical and magnetic properties than current electrical steels (Fe-3.2% Si as benchmark). The applications domain for these steels is electrical motor core laminations. We have addressed this goal by accomplishment of the following specific objectives and tasks: a) Development of an Fe-4Si-4Cr alloy with electrical resistivity >80 μΩ-cm, induction flux density >1.48 T at 5000 A/m and core loss 35% lower than the benchmark 3.2% Si alloy. The alloy which meets DOE target specifications for motor core attributes was designed with the Si content controlled for the electrical properties and the Cr content tailored to meet material/process workability requirements. b) A unique machining-based deformation processing system was designed and scaled-up to produce strip of commercial width (25 mm to 150 mm) and thickness (up to 0.5 mm) from the Fe-4Si-4Cr alloy and other alloys of varied workability including copper, Al6061-T6 and naval brass. The key attributes of the machining-based strip production are deformation processing by concentrated simple-shear; single-step production of strip from ingot using compact machine infrastructure; strip surface finish of Ra 0.35 to 1 micrometer that is comparable/superior to that of rolled strip; discrete production of strip that can potentially be done at point of use; and controllability of strip mechanical/formability properties by deformation control. c) The electrical, magnetic, surface quality, mechanical, formability, and metallurgical properties/attributes of the machining-based strip were established by direct ASTM standard or equivalent measurement techniques. d) Punching characteristics of the strip in terms of load, edge quality and macro defects were similar to those of conventional 3.2% Si electrical steels. These punching characteristics are critical from a manufacturability perspective for motor/transformer core applications. e) A modeling framework for energy analysis of multistage rolling and the machining-based deformation processing has been established. Application of this modeling to the two strip-processes showed that the machining-based process requires significantly lower specific energy for processing, ~ 25% of that for rolling. The modeling framework can be adapted for a range of sheet-metal forming, bulk metal forming, and machining processes. It can be used to identify key parameters controlling process specific energy. f) A comparative analysis of advantages and disadvantages of machining-based processing against rolling for strip production. The single stage machining-based processing, with compact infrastructure, represents a new manufacturing paradigm for sheet and foil manufacturing that can potentially also be applied to advanced titanium, aluminum, copper and magnesium alloys. The goals and objectives were accomplished by a cross-disciplinary project team comprising of personnel from Purdue University; M4 Sciences LLC, a small-business focused on advanced manufacturing technology development; the Pacific Northwest National Labs; and tool manufacturers. The team is currently in advanced discussions with multiple entities for future process development for commercialization.

36 MATERIALS SCIENCE↗

Demonstration of Microwave Cavity Transducer Performance in High Temperature Fluid Flow Sensing: Development of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment, which is similar to that of an advanced reactor. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. For this test, we have developed a cylindrical resonator, which was machined from stainless steel 316 and electroplated with silver on the interior surfaces. Outer diameter of the cylindrical cavity is approximately 3cm, and the thin wall is approximately 200µm thick. We have also developed and insertion probe consisting of a 50cm WR-42 brass waveguide enclosed in a protective SS316 tube. The cavity was excited through a WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. As a calibration experiment, we have assembled a water vessel with a center feed, and with dimensions similar to those of the liquid sodium setup. Frequency shift of the cavity spectral response was obtained at room temperature and ambient pressure by gradually increasing water flow rate from 0 to 25GPM (gallons per minute). Corresponding monotonic increase of resonant frequency by several hundred KHz was observed. Next, a sodium flow rate sensing study was performed in a liquid sodium vessel at 340° C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred KHz was observed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Probabilistic Analysis of Long-Term Degradation of Microwave Cavity Flow Sensor

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with the flat wall of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the resonant frequency, which can be detected with a spectrum analyzer. We have performed a proof-of-concept experiment of flow sensing with the transducer in liquid sodium at 340°C in impinging liquid jet geometry. The transducer remained in liquid sodium for 70 days. After removal, no structural damage was observed, and the expected transducer response was verified in a water test. Because long-term (multi-year) experimental tests of transducer resilience to harsh environment are not practical, we have developed a probabilistic model of creep to estimate transducer resilience to the harsh environment. The probabilistic model considers diffusion creep under the condition of high temperature and low stress, where the stress and temperature are allowed to be random variables with Gaussian distributions. Using the probabilistic model, we estimate inelastic membrane deflections due to creep for several temperature ranges. We conclude that for temperatures less than 650°C, creep has negligible long-term effect on the transducer performance. Since a yellowish residue was observed on the transducer surface after 70 days of immersion in liquid sodium, we have investigated possible evidence of corrosion. Chromium depletion is a typical indicator of the corrosion process in stainless steel. Scraping off a residue from the transducer and performing scanning electron microscopy (SEM) with energy dispersive analysis (EDS) did not find any chromium in the residue. Approximately 60% of the residue consisted of copper, which can be attributed to contamination of sodium due to powder residue from machining of copper and brass components of the transducer.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Nanostructured Black Nickel Coating as Replacement for Black Cr(VI) Finish

This work compares different electrodeposition procedures to produce nickel black coatings as greener and less toxic alternatives to Cr(VI)-based coatings used in different applications. Nickel and nickel-plated brass served as substrates in studies with a Hull cell and polarization curves. After a set of comparative experiments, the best electrodeposition procedure was further studied and optimized. Optimal conditions were found with a bath consisting of 75 g/L NiCl2·6H2O + 30 g/L NaCl and a current density of 0.143 A dm−2 applied for 5 min at room temperature. Furthermore, a pre-treatment with 18.5 vol.% of hydrochloric acid in water was found to be necessary to warrant good coating adhesion to the substrate. The black color is attributed to the development of a nanostructured surface that absorbs the incident light. Corrosion testing was performed in 0.5 M NaCl aqueous solution using electrochemical impedance spectroscopy (EIS) and polarization tests.

Mennucci, Marina M. (ORCID:0000000171886804)↗

Electrode Erosion and Prefire Studies Towards Fusion Scale Pulsed Power

This study presents a comprehensive investigation of electrode erosion and discharge behavior in spark gap switches over long switching cycle lifetimes. Brass, copper–tungsten (CuW), and stainless steel electrodes are tested under controlled conditions to quantify material degradation, debris accumulation, and changes in breakdown voltage. High-resolution imaging and statistical analysis of spark channel locations and gap breakdown voltages reveal how surface evolution influences long-term performance and reliability. These results provide essential data for lifetime modeling and inform design strategies for pulsed power systems in emerging applications such as private sector fusion energy and large-scale facilities like Sandia’s Z Machine and proposed ZX upgrades, where high repetition reliability and predictable behavior are critical.

electrical breakdown↗

An Experimental and Numerical Analysis of the Compression of Bimetallic Cylinders

This paper investigates the upsetting of bimetallic cylinders with an aluminum alloy center and a brass ring. The influence of the center-ring shape factor and type of assembly fit (interference and clearance), and the effect of friction on the compression force and ductile damage are comprehensively analyzed by means of a combined numerical-experimental approach. Results showed that the higher the shape factor, the lower the forces required, whereas the effect of friction is especially important for cylinders with the lowest shape factors. The type of assembly fit does not influence the compression force. The accumulated ductile damage in the compression of bimetallic cylinders is higher than in single-material cylinders, and the higher the shape factor, the lower the damage for the same amount of stroke. The highest values of damaged were found to occur at the middle plane, and typically in the ring. Results also showed that an interference fit was more favorable for preventing fracture of the ring than a clearance fit. Microstructural analysis by scanning electron microscopy revealed a good agreement with the finite element predicted distribution of ductile damage.

36 MATERIALS SCIENCE↗

Technoeconomic Benefits of Film-Forming Amine Products Applied to Steam Surface Condensers

In a conventional Rankine cycle, the majority of power plants employ surface condensers that use pumped cooling water to reject heat from the cycle. In such cases, heat rejection occurs in a shell and tube heat exchanger by film-wise condensation of low-pressure steam on stainless steel, titanium, brass, or copper-nickel tubing. To improve the thermal performance of steam surface condensers, a replenishable film-forming substance (FFS) can be ap-plied to the condenser tubing to promote efficient dropwise condensation. Conventionally, film-forming amine prod-uct (FFAP) coatings protect boiler surfaces from oxidative corrosion, which substantially reduces the operation and maintenance costs. To quantify the technical and economic benefits of FFAP coatings applied to condenser tubing due to the promotion of dropwise condensation, a thermal resistance network model was established. Using a rep-resentative steam surface condenser, the improvements in thermal performance (overall heat transfer coefficient) and process parameters (net plant efficiency, cooling water flowrate, and turbine backpressure) were determined due to the enhancement in the condensation heat transfer coefficient. Experimentally measured condensation heat transfer coefficients for common condenser materials were compared with the modeling results and were found to be within attainable bounds. Lastly, the trend in total heat exchanger cost reduction is generalized to understand the trade-off between reduced surface area for heat rejection and increase in coating application costs for a re-plenishable coating system.

20 FOSSIL-FUELED POWER PLANTS↗

Testing of the 2.6 GHz SRF Cavity Tuner for the Dark Photon Experiment at 2 K

At FNAL two single cell 2.6 GHz SRF cavities are being used to search for dark photons, the experiment can be conducted at 2 K or in a dilution refrigerator. Precise frequency tuning is required for these two cavities so they can be matched in frequency. A cooling capacity constraint on the dilution refrigerator only allows piezo actuators to be part of the design of the 2.6 GHz cavity tuner. The tuner is equipped with three encapsulated piezos that deliver long and short-range frequency tuning. Modifications were implemented on the first tuner design due to the low forces on the piezos caused by the cavity. Three brass rods with Belleville washers were added to the design to increase the overall force on the piezos. The testing results at 2 K are presented with the original design tuner and with the modification.

43 PARTICLE ACCELERATORS↗

Application of Nuclear Technology to Art Identification Problems: First Annual Report

Throughout the centuries, as man has become increasingly affluent, his interest in antiquities and objects of art, and the price he has been willing to pay for them, has increased. Inevitably, one result has been to attract the unscrupulous to the production and sale of counterfeit paintings, sculptures, and other works of art. The skill of forgers varies but often is highly sophisticated. However, dealers, museum curators, and other experts have also become more skillful in the detection of forgeries. Scientific tools of increasing sensitivity and sophistication have gradually been applied to the examination of the materials of art and archaeology. Such tools frequently support and render more reliable the judgment of the experts. The quality of forgeries may improve further as their makers become acquainted with the new methods of detection and in turn learn to circumvent or confound the methods. Therefore, the development of still more advanced methods of examination has great utility in the art world. This is particularly true if the ultimate effect is to make circumvention of the methods of examination so costly that the economic incentives for producing forgeries may be substantially reduced, if not eliminated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Effect of Melt Ultrasound Treatment on the Microstructure and Age Hardenability of Al-4 Wt Pct Cu/TiC Composite

In the present work, Al-4 wt pct Cu/TiC composite was synthesized by the molten salt route that contains submicron-sized TiC particles in the Al-4 wt pct Cu matrix. The concentration of the TiC particle in the base alloy is 7.5 wt pct. Melt ultrasound treatment was done by remelting the as-cast composite at 1023 K (750 °C) in a view to refine the size of TiC particles to nanoscale and distribute them evenly in the matrix. The microstructure and age hardenability of the untreated and ultrasound-treated composites were investigated. The TiC particles accelerate the precipitation kinetics of CuAl{sub 2} phase in Al-4 wt pct Cu alloy. In the present study, the hardness obtained for untreated Al-4 wt pct Cu/TiC composite is 120 VHN within 5 hours of peak aging time, which is higher than the hardness of the monolithic Al-4 wt pct Cu, which is 104 VHN at 35 hours of peak aging time. Melt ultrasound treatment of Al-4 wt pct Cu/TiC composite shows no significant effect on the distribution and refinement of TiC particles in the matrix. However, it partially disintegrates the TiC into Al{sub 3}Ti and Al{sub 4}C{sub 3} particles. The ultrasound-treated composite showed an improved hardness of about 132 VHN at 5 hours of peak aging, in comparison to that of the untreated composite, by forming denser and homogeneous CuAl{sub 2} precipitates.

36 MATERIALS SCIENCE↗

Probing Oxidation-Driven Amorphized Surfaces in a Ta(110) Film for Superconducting Qubit

Recent advances in superconducting qubit technology have led to significant progress in quantum computing, but the challenge of achieving a long coherence time remains. Despite the excellent lifetime performance that tantalum (Ta) based qubits have demonstrated to date, the majority of superconducting qubit systems, including Ta-based qubits, are generally believed to have uncontrolled surface oxidation as the primary source of the two-level system loss in two-dimensional transmon qubits. Therefore, atomic-scale insight into the surface oxidation process is needed to make progress toward a practical quantum processor. Here, in this study, the surface oxidation mechanism of native Ta films and its potential impact on the lifetime of superconducting qubits were investigated using advanced scanning transmission electron microscopy (STEM) techniques combined with density functional theory calculations. The results suggest an atomistic model of the oxidized Ta(110) surface, showing that oxygen atoms tend to penetrate the Ta surface and accumulate between the two outermost Ta atomic planes; oxygen accumulation at the level exceeding a 1:1 O/Ta ratio drives disordering and, eventually, the formation of an amorphous Ta 2 O 5 phase. In addition, we discuss how the formation of a noninsulating ordered TaO 1–δ (δ < 0.1) suboxide layer could further contribute to the losses of superconducting qubits. Subsurface oxidation leads to charge redistribution and electric polarization, potentially causing quasiparticle loss and decreased current-carrying capacity, thus affecting superconducting qubit coherence. The findings enhance the comprehension of the realistic factors that might influence the performance of superconducting qubits, thus providing valuable guidance for the development of future quantum computing hardware.

36 MATERIALS SCIENCE↗

Dissolution of a Can Carrier Pin in Concentrated Nitric Acid

H=Canyon will be dissolving Fast Critical Assembly (FCA) fuel from the Japan Atomic Energy Agency (JAEA). The FCA fuel will be dissolved in the electrolytic dissolver in a solution that is a 50 wt.% nitric acid (HNO 3 ), 0.5 g/l gadolinium (Gd), and 0.05 M potassium fluoride (KF). The nitric acid concentration is expected to decrease during the batch process from 10.3 to 7 M. The temperature of the nitric acid solution may be as low as 15 °C. The fuel can will be placed in the dissolver basket insert utilizing a reusable charging device. The charging device is a coated stainless-steel rod with a clevis design. The charging device employs a linchpin to secure the FCA fuel can as it is being charged into the H-canyon dissolver. Prior to beginning the electrolytic dissolution process, the pin will be dissolved, the fuel can will remain in the dissolver basket insert and the charging device will be removed. Currently the time necessary for complete dissolution of the pin is unknown and thus the timing of the removal of the charging device cannot be planned. This process is to be performed remotely and therefore complete dissolution of the pin will not be able to be visually determined. The pin will be made of a material that dissolves in the concentrated nitric acid solution in the dissolver. The facility desired to know the time that the pin would be dissolved so that the charging device for the FCA can could be removed from the dissolver. In particular, the pin dissolution time as a function of the nitric acid concentration and the temperature was desired. The facility would like to ensure that the solution environment was such that the charging device could be removed within an operational shift (8-12 hours).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Challenges and Solutions in Operation and Lay-Up of the Modular Caustic- Side Solvent Extraction Unit - 20078

The Modular Caustic-Side Solvent Extraction (CSSX) Unit (MCU) was designed and constructed to provide interim salt waste processing so that the Liquid Waste Disposition Program (LWDP) could continue waste removal and tank closure until start-up of the Salt Waste Processing Facility (SWPF). MCU processes Clarified Salt Solution (CSS), or salt solution (SS) that has undergone actinide removal/filtration, to produce two waste streams: the cesium laden Strip Effluent (SE), which is incorporated into glass at the Defense Waste Processing Facility (DWPF), and the cesium depleted Decontaminated SS (DSS), which is incorporated into grout at the Saltstone Production Facility (SPF). MCU completed start-up in 2008 with an initial operating life of 3 years and design life of 5 years. Prior to reaching the end of the design life, multiple critical components were upgraded and/or replaced to mitigate risks associated with any delays in SWPF start-up. During the remainder of operation (until June 2019), MCU was challenged to maximize processing with minimal additional modifications to repair/improve aging infrastructure, while maintaining low levels of risk to workers and the environment. Notable challenges during the extended operating life of the facility involved both mechanical and operational issues. Two of the most significant issues were the increased frequency of Process Vessel Ventilation (PVV) High Efficiency Particulate Air (HEPA) filter change-outs and the biofouling of the SE coalescer (SEC). The major impacts of both issues were that replacement of these components 1) resulted in high exposure to workers, and 2) required substantial downtime, thus hindering achievement of processing goals. PVV HEPA filter replacements are required based on dose rate and differential pressure (dP) limits. After introducing a higher-curie feed to MCU, the operating time between change outs was reduced by approximately half. SEC replacements are required based on dP limits. After restarting from an extended outage, the operating life of the SEC was significantly reduced by more than half due to biofouling. As a result of extensive troubleshooting and process improvements, the facility was able to recover performance and extend the operating life of the PVV HEPA filters and the SEC media. Through troubleshooting both of these issues, the facility was also able to learn from prior experience and adapt in order to minimize down time and maintain throughput. Although the facility took advantage of short periods of downtime to perform nonintrusive troubleshooting and minor corrective/preventative maintenance activities, longer outages were periodically required for corrective maintenance involving process cell entry. During these outages, remote tools and specialized shield plates were employed to minimize dose to workers. Mock-ups of non-routine maintenance activities were critical to early identification of potential issues and improvements, which shortened outage duration. Consistent with the facility's operational strategy, evolutions needed for MCU layup were identified and sequenced to ensure safe conditions within the facility, meet pre-defined criteria for lay-up configuration, and protect workers, while minimizing the impact to SWPF integration. De-inventory and flushing of process areas was prioritized so that the total residual inventory was reduced as efficiently as possible. This paper discusses lessons learned and best practices from troubleshooting unique issues, performing complex maintenance activities, and implementing a layup strategy that best supports the overall system mission. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗