Search NASA⌕ Search

SEARCH · Search NASA

Results for “Bagging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Portable Intravenous Fluid Production Device For Ground Use Project

Several medical conditions require the administration of intravenous (IV) fluids,but limitations of mass, volume, shelf-life, transportation, and local resources can restrict the availability of these important fluids. Such limitations are expected in long-duration space exploration missions and in remote or austere places on Earth. This design uses regular drinking water that is pumped through two filters to produce, in minutes, sterile, ultrapure water that meets the stringent quality standards of the United States Pharmacopeia for Water for Injection (Total Bacteria, Conductivity, Endo - toxins, Total Organic Carbon). The device weighs 2.2 lb (1 kg) and is 10 in. long, 5 in. wide, and 3 in. high (≈25, 13, and 7.5 cm, respectively) in its storage configuration. This handheld device produces one liter of medical-grade water in 21 minutes. Total production capacity for this innovation is expected to be in the hundreds of liters. The device contains one battery powered electric mini-pump. Alternatively, a manually powered pump can be attached and used. Drinking water enters the device from a source water bag, flows through two filters, and final sterile production water exits into a sealed, medical-grade collection bag. The collection bag contains pre-placed crystalline salts to mix with product water to form isotonic intravenous medical solutions. Alternatively, a hypertonic salt solution can be injected into a filled bag. The filled collection bag is detached from the device and is ready for use or storage. This device currently contains one collection bag, but a manifold of several pre-attached bags or replacement of single collection bags under sterile needle technique is possible for the production of multiple liters. The entire system will be flushed, sealed, and radiation-sterilized. Operation of the device is easy and requires minimal training. Drinking water is placed into the collection bag. Inline stopcock flow valves at the source and collection bags are opened, and the mini-pump is turned on by a switch to begin fluid flow. When the collection bag is completely filled with the medical- grade water, the pump can be turned off. The pump is designed so it cannot pump air, and overfilling of the collection bag with fluid is avoided by placing an equal amount of water in the source bag. Backflow is avoided by inline check valves. The filled collection bag is disconnected from its tubing and is ready for use. The source bag can be refilled for production of multiple liters, or the source bag can be replaced with an input tube that can be placed in a larger potable water source if the device is attended. The device functions in all orientations independent of any gravity fields. In addition to creating IV fluids, the device produces medical-grade water, which can be used for mixing with medications for injection, reconstituting freeze-dried blood products for injection, or for wound hydration or irrigation. Potential worldwide use is expected with medical activities in environments that have limited resources, storage, or resupply such as in military field operations, humanitarian relief efforts, submarines, commercial cruise ships, etc.

Technology Portfolio System↗

Design and development of pressure and repressurization purge system for reusable space shuttle multilayer insulation system

The experimental determination of purge bag materials properties, development of purge bag manufacturing techniques, experimental evaluation of a subscale purge bag under simulated operating conditions and the experimental evaluation of the purge pin concept for MLI purging are discussed. The basic purge bag material, epoxy fiberglass bounded by skins of FEP Teflon, showed no significant permeability to helium flow under normal operating conditions. Purge bag small scale manufacturing tests were conducted to develop tooling and fabrication techniques for use in full scale bag manufacture. A purge bag material layup technique was developed whereby the two plys of epoxy fiberglass enclosed between skins of FEP Teflon are vacuum bag cured in an oven in a single operation. The material is cured on a tool with the shape of a purge bag half. Plastic tooling was selected for use in bag fabrication. A model purge bag 0.6 m in diameter was fabricated and subjected to a series of structural and environmental tests simulating various flight type environments. Pressure cycling tests at high (450 K) and low (200 K) temperature as well as acoustic loading tests were performed. The purge bag concept proved to be structurally sound and was used for the full scale bag detailed design model.

Source record↗

Large thermal protection system panel

A protective panel for a reusable launch vehicle provides enhanced moisture protection, simplified maintenance, and increased temperature resistance. The protective panel includes an outer ceramic matrix composite (CMC) panel, and an insulative bag assembly coupled to the outer CMC panel for isolating the launch vehicle from elevated temperatures and moisture. A standoff attachment system attaches the outer CMC panel and the bag assembly to the primary structure of the launch vehicle. The insulative bag assembly includes a foil bag having a first opening shrink fitted to the outer CMC panel such that the first opening and the outer CMC panel form a water tight seal at temperatures below a desired temperature threshold. Fibrous insulation is contained within the foil bag for protecting the launch vehicle from elevated temperatures. The insulative bag assembly further includes a back panel coupled to a second opening of the foil bag such that the fibrous insulation is encapsulated by the back panel, the foil bag, and the outer CMC panel. The use of a CMC material for the outer panel in conjunction with the insulative bag assembly eliminates the need for waterproofing processes, and ultimately allows for more efficient reentry profiles.

Myers, Franklin K.↗

Multiple-Instance Regression with Structured Data

We present a multiple-instance regression algorithm that models internal bag structure to identify the items most relevant to the bag labels. Multiple-instance regression (MIR) operates on a set of bags with real-valued labels, each containing a set of unlabeled items, in which the relevance of each item to its bag label is unknown. The goal is to predict the labels of new bags from their contents. Unlike previous MIR methods, MI-ClusterRegress can operate on bags that are structured in that they contain items drawn from a number of distinct (but unknown) distributions. MI-ClusterRegress simultaneously learns a model of the bag's internal structure, the relevance of each item, and a regression model that accurately predicts labels for new bags. We evaluated this approach on the challenging MIR problem of crop yield prediction from remote sensing data. MI-ClusterRegress provided predictions that were more accurate than those obtained with non-multiple-instance approaches or MIR methods that do not model the bag structure.

learning↗

Improvements to On-Orbit Sleeping Accommodations

United States On-Orbit Segment (USOS) crew members aboard the International Space Station (ISS) are each furnished with a Crew Quarters that serves as their personal private space for the duration of their expedition. Within these quarters, crew members use sleeping bags to provide a comfortable environment that is conducive to sleeping in microgravity. Microgravity presents unique challenges to obtaining good sleep. Sleep position preferences which are influenced by gravity are disturbed when the feeling is absent while other environmental factors prevent the familiar feeling of lying in bed. NASA developed a new US Sleeping Bag for USOS crew members launching aboard United States Crewed Vehicles (USCVs), using this opportunity to improve upon the current sleeping bag design based on lessons learned from years of living and working in space. The US Sleeping Bag design was based on the current sleeping bag's design with enhancements to key features based on feedback from crew members and sleep study experts at the Johnson Space Center and the Ames Research Center. Key areas of improvement include facilitating thermal comfort in the warm Crew Quarters environment, ease of maintenance when replacing the inner lining, allowing for maximum versatility for adjustment to crew preference, and adding features for additional functionality such as accommodations for a pillow. Two US Sleeping Bags have flown aboard the ISS to date, utilized by veteran crew members who have experience with the existing sleeping bags and have provided feedback and comparisons for assessment. Enabling good sleep is essential for crew member health and productivity, especially in longer duration expeditions. This paper will detail the challenges with sleeping in microgravity and the enhancements made in development of the US Sleeping Bag to provide a better on-orbit sleep environment.

US Sleeping Bag↗

Harvesting Microgreens in Microgravity: Analysis of Six Different Methods

In long duration space missions, crops will be used to supplement the astronaut diet. One such proposed crop type is microgreens, the young seedlings of edible plants that are known for their high nutritional levels, intense flavors, colorful appearance, and variety of textures. While these characteristics make microgreens a great candidate for space crop production, their small size presents a unique challenge within the microgravity environment. To ensure that astronauts will be able to harvest microgreens in microgravity with ease while avoiding the introduction of debris to the spacecraft cabin, multiple harvesting methods were developed by the Space Crop Production Team at NASA’s Kennedy Space Center. Three parabolic flights were conducted in November and December of 2021 and during those flights three different microgreen cutting methods (guillotine, pepper grinder, scissors) as well as two different bagging methods (attached and manual) were tested. In each flight, the microgreens were contained inside of a glovebox and footage of all the microgreen harvests was recorded. The cutting and bagging method combination that introduced the lowest average number of particulates into the glovebox was the scissors with attached bagging, closely followed by the pepper grinder with attached bagging. However, the scissors with attached bagging may had introduced fewer particulates into the glovebox because on average, 27% of the microgreens were never cut using the scissors method, so there were fewer free-floating particulates generated. The cutting and bagging method combination that left the lowest average percentage of microgreens remaining on the hardware post-harvest was the pepper grinder with an attached bag. Future directions include involving microgreen harvests in analog environments and further development of the different microgreen cutting and bagging methods. This research was funded by multiple NASA grants at the Kennedy Space Center.

Haley O Boles↗

Gray matter volume drives the brain age gap in schizophrenia: a SHAP study

Neuroimaging-based brain age is a biomarker that is generated by machine learning (ML) predictions. The brain age gap (BAG) is typically defined as the difference between the predicted brain age and chronological age. Studies have consistently reported a positive BAG in individuals with schizophrenia (SCZ). However, there is little understanding of which specific factors drive the ML-based brain age predictions, leading to limited biological interpretations of the BAG. We gathered data from three publicly available databases - COBRE, MCIC, and UCLA - and an additional dataset (TOPSY) of early-stage schizophrenia (82.5% untreated first-episode sample) and calculated brain age with pre-trained gradient-boosted trees. Then, we applied SHapley Additive Explanations (SHAP) to identify which brain features influence brain age predictions. We investigated the interaction between the SHAP score for each feature and group as a function of the BAG. These analyses identified total gray matter volume (group × SHAP interaction term β = 1.71 [0.53; 3.23]; p corr < 0.03) as the feature that influences the BAG observed in SCZ among the brain features that are most predictive of brain age. Other brain features also presented differences in SHAP values between SCZ and HC, but they were not significantly associated with the BAG. We compared the findings with a non-psychotic depression dataset (CAN-BIND), where the interaction was not significant. This study has important implications for the understanding of brain age prediction models and the BAG in SCZ and, potentially, in other psychiatric disorders.

60 APPLIED LIFE SCIENCES↗

Effects of Microbial-Mineral Interactions on Organic Carbon Stabilization in a Ponderosa Pine Root Zone: A Micro-Scale Approach

Soil microbial communities affect the formation of micro-scale mineral-associated organic matter (MAOM) where complex processes, including adhesion, aggregate formation, microbial mineral weathering and soil organic matter stabilization occur in a narrow zone of large biogeochemical gradients. Here we designed a field study to examine carbon stabilization mechanisms by using in-growth mesh bags containing biotite that were placed in a ponderosa pine root zone for 6 months and compared to the surrounding bulk soil. We sought to determine the composition of the microbial community in the mesh bags compared to the surrounding soils, analyze the direct interactions between microbes and biotite, and finally identify the nature of the newly formed MAOM within the mesh-bags. Our results revealed that minerals in the mesh bags were colonized by a microbial community that produced organic matter in situ. The 16S rRNA gene sequencing and ITS2 region characterization showed phylogenetic similarity between the mesh bag and bulk soil archaea/bacteria and fungi microbiomes, with significant differences in alpha- and beta-diversity and species abundances. Organic matter pools in the mesh bags, analyzed by Fourier transform ion cyclotron resonance mass spectrometry, contained protein- (peptides) and lipid-like compounds while the bulk soil OM was comprised of lignin-like and carboxyl-rich alicyclic molecules. These results support that the newly formed biotite associated organic compounds have a microbial signature in the mesh bags. High-resolution electron microscopy documented strongly adhered organic compounds to biotite surfaces, formation of microaggregates, elemental uptake at the microbe (organic matter)-mineral interface, and distortion of biotite layers. Overall, this study shows the direct and indirect involvement of soil microbial communities from the root zone of ponderosa pine in the formation of MAOM, soil organic carbon stabilization, microaggregation, and mineral weathering at micro- and nano-scales.

58 GEOSCIENCES↗

Engine protection system for recoverable rocket booster

A rocket engine protection system for a recoverable rocket booster which is arranged to land in a salt water body in substantially a nose down attitude. The system includes an inflatable bag which is stowed on a portion of a flat annular rim of the aft skirt of the booster. The bag is hinged at opposing sides and is provided with springs that urge the bag open. The bag is latched in a stowed position during launch and prior to landing for recovery is unlatched to permit the bag to be urged open and into sealing engagement with the rim. A source of pressurized gas further inflates the bag and urges it into sealing engagement with the rim of the skirt where it is locked into position. The gas provides a positive pressure upon the interior of the bag to preclude entry of salt water into the skirt and into contact with the engine. A flotation arrangement may assist in precluding the skirt of the booster from becoming submerged.

Shelby, Jr., Jerry A.↗

Nearly Seamless Vacuum-Insulated Boxes

A design concept, and a fabrication process that would implement the design concept, have been proposed for nearly seamless vacuum-insulated boxes that could be the main structural components of a variety of controlled-temperature containers, including common household refrigerators and insulating containers for shipping foods. In a typical case, a vacuum-insulated box would be shaped like a rectangular parallelepiped conventional refrigerator box having five fully closed sides and a hinged door on the sixth side. Although it is possible to construct the five-closed-side portion of the box as an assembly of five unitary vacuum-insulated panels, it is not desirable to do so because the relatively high thermal conductances of the seams between the panels would contribute significant amounts of heat leakage, relative to the leakage through the panels themselves. In contrast, the proposal would make it possible to reduce heat leakage by constructing the five-closed-side portion of the box plus the stationary portion (if any) of the sixth side as a single, seamless unit; the only remaining seam would be the edge seal around the door. The basic cross-sectional configuration of each side of a vacuum-insulated box according to the proposal would be that of a conventional vacuum-insulated panel: a low-density, porous core material filling a partially evacuated space between face sheets. However, neither the face sheets nor the core would be conventional. The face sheets would be opposite sides of a vacuum bag. The core material would be a flexible polymer-modified silica aerogel of the type described in Silica/Polymer and Silica/Polymer/Fiber Composite Aero - gels (MSC-23736) in this issue of NASA Tech Briefs. As noted in that article, the stiffness of this core material against compression is greater than that of prior aerogels. This is an important advantage because it translates to greater retention of thickness and, hence, of insulation performance when pressure is applied across the thickness, in particular, when the space between the face sheets is evacuated, causing the core material to be squeezed between the face sheets by atmospheric pressure. Fabrication of a typical vacuum-insulated box according to the proposal would begin with fabrication of a cross-shaped polymer-modified aerogel blanket. The dimensions of the cross would be chosen so that (1) the central rectangular portion of the cross would form the core for the back of the box and (2) the arms of the cross could be folded 90 from the back plane to form the cores of the adjacent four sides of the box. Optionally, the blanket could include tabs for joining the folded sides of the blanket along mating edges and tabs that could serve as hinges for the door. Vacuum bags in the form of similar five-sided boxes would be made of a suitable polymeric film, one bag to fit the outer core surface, the other to fit the inner core surface. By use of commercially available film-sealing equipment, these box-shaped bags would be seamed together to form a single vacuum bag encasing the box-shaped core. Also, a one-way valve would be sealed to the bag. Through this valve, the interior of the bag would be evacuated to a pressure between 1 and 10 torr (approximately between 0.13 and 1.3 kPa). The polymer-modified aerogel core material is known to perform well as a thermal insulator in such a partial vacuum.

Stepanian, Christopher J.↗

Final Report for Intravenous Fluid Generation (IVGEN) Spaceflight Experiment

NASA designed and operated the Intravenous Fluid Generation (IVGEN) experiment onboard the International Space Station (ISS), Increment 23/24, during May 2010. This hardware was a demonstration experiment to generate intravenous (IV) fluid from ISS Water Processing Assembly (WPA) potable water using a water purification technique and pharmaceutical mixing system. The IVGEN experiment utilizes a deionizing resin bed to remove contaminants from feedstock water to a purity level that meets the standards of the United States Pharmacopeia (USP), the governing body for pharmaceuticals in the United States. The water was then introduced into an IV bag where the fluid was mixed with USP-grade crystalline salt to produce USP normal saline (NS). Inline conductivity sensors quantified the feedstock water quality, output water purity, and NS mixing uniformity. Six 1.5-L bags of purified water were produced. Two of these bags were mixed with sodium chloride to make 0.9 percent NS solution. These two bags were returned to Earth to test for compliance with USP requirements. On-orbit results indicated that all of the experimental success criteria were met with the exception of the salt concentration. Problems with a large air bubble in the first bag of purified water resulted in a slightly concentrated saline solution of 117 percent of the target value of 0.9 g/L. The second bag had an inadequate amount of salt premeasured into the mixing bag resulting in a slightly deficient salt concentration of 93.8 percent of the target value. The USP permits a range from 95 to 105 percent of the target value. The testing plans for improvements for an operational system are also presented.

McQuillen, John B.↗

Outgassing Characterization of Common Trash Items for Disposal By Nanoracks Airlock on the International Space Station

The arrival of the Nanoracks Airlock to the International Space Station (ISS) has provided the ISS program the capability to dispose of common trash items. The concept of operations involved the crew bagging up those items into a trash bag and then utilizing the robotic arm and the airlock to jettison the trash bag. Because of the unknown thermal vacuum stability of some of the items, a molecular contamination concern was raised by the ISS program as the trash is exposed to vacuum upon the evacuation of air from the airlock and the robotic arm moving the airlock to its jettison location. In order to characterize the representative outgassing rates for ISS trash, thermal vacuum testing was performed at White Sands Test Facility. Trash was sorted into a “lower” outgassing bag and a “mixed” bag. The “mixed” trash bag contained more items that were suspected to be not vacuum stable. Load cells were chosen as the primary means for measuring mass loss. A sharp decay in the outgassing rate was observed in the first 30 minutes followed by a slower decay. As expected, the “mixed” bag lost more mass. While Quartz Crystal Microbalances (QCMs) are often utilized to measure long term outgassing rates and the sticking coefficients of contaminants at different operating temperatures for vacuum stable materials, these measurements proved difficult due to the amount and the inclusion of materials with suspect thermal vacuum stability. Because of high rates of material outgassing, the facility was unable to maintain the CQCM temperature setpoint of 80 K QCMs.. The QCMs operating at the warmer temperatures also saturated on occasion due to high levels of condensed matter. Though testing was able to confirm high risk of outgassing contamination for the program, true sticking coefficients could not be determined, available measurements are provided herein.

Alvin Y Huang↗

Developing an Active Learning algorithm for learning Bayesian classifiers under the Multiple Instance Learning scenario

In the Multiple Instance Learning scenario, the training data consists of instances grouped into bags, and each bag is labelled with whether it is positive, i.e. contains at least one positive instance. First, Active Learning, in which additional labels can be iteratively requested, has the potential to allow more accurate classifiers to be learned with less labels. Active Learning has been applied to the Multiple Instance Learning under two settings: when bag labels of unlabelled bags can be requested, and when instance labels within bags known to be positive can be requested. Second, Bayesian Active learning methods have the potential to learn accurate classifiers with few labels, because they explicitly track the classifier uncertainty and can thus address its knowledge gaps. Yet, there does not exist any Bayesian Active Learning method for the Multiple Instance Learning Scenario. In this work, we develop the first such method. We develop a Bayesian classifier for the Multiple Instance Learning scenario, show how it can be efficiently used for Bayesian Active Learning, and perform experiments assessing its performance. While its performance exceeds that when no Active Learning is used, it is sometimes better, sometimes worse than the naive baseline of uncertainty sampling, depending on the situation. This suggests future work: building more customizable Bayesian Active Learning methods for the Multiple Instance Scenario, customizable to whether bag or instance label accuracy is targeted, and the labeling budget.

97 MATHEMATICS AND COMPUTING↗

Flow rate logging seepage meter

An apparatus for remotely measuring and logging the flow rate of groundwater seepage into surface water bodies. As groundwater seeps into a cavity created by a bottomless housing, it displaces water through an inlet and into a waterproof sealed upper compartment, at which point, the water is collected by a collection bag, which is contained in a bag chamber. A magnet on the collection bag approaches a proximity switch as the collection bag fills, and eventually enables the proximity switch to activate a control circuit. The control circuit then rotates a three-way valve from the collection path to a discharge path, enables a data logger to record the time, and enables a pump, which discharges the water from the collection bag, through the three-way valve and pump, and into the sea. As the collection bag empties, the magnet leaves the proximity of the proximity switch, and the control circuit turns off the pump, resets the valve to provide a collection path, and restarts the collection cycle.

Reay, William G.↗

Recommendations For Developing Space Suit Integrated Food Systems and Delivering Nutrition Before, During, and After Lunar Eva

INTRODUCTION Artemis missions will include a higher tempo and frequency of extravehicular activities (EVAs) than any previous space program. Because of the physical demands expected from the crew, future space suit designs are required to incorporate nutritional support to the astronauts during lunar surface EVAs lasting longer than 4 hours. The purpose of this project was to provide recommendations to aid the development of an in-suit system that can adequately, safely, and acceptably deliver nutrition to a crewmember while confined to a space suit during EVA. METHODS Physiological, logistical, and engineering aspects of potential in-suit nutrition approaches were assessed through literature reviews, assessments of commercial off the shelf (COTS) foods, suit volumetric modeling, and feedback from subject matter experts and crewmembers. Key driving factors in the development of in-suit nutrition requirements included how much and what type of nutrition should be included, what food formulations are appropriate and safe, what are inherent limitations of space suits, what are the potential risks to the crewmember in the suit, and what practices and preferences from astronauts should be considered. Design references were conceptualized and assessed for strengths and limitations as potential in-suit nutrition systems for surface EVA. RESULTS Acute exogenous energy demands vary greatly depending on activity intensity and duration, and partial energy replenishment (i.e., 60–80 kcal∙hr-1 of EVA, or 460–680 kcal for EVAs lasting up to 8 hours) during activities could improve performance, safety, and recovery. COTS foods capable of providing these energy requirements exist; however, no COTS foods have been identified that pass NASA flight standards for microbiological safety and stability. In-suit nutrition delivery design references that were considered included in-suit concepts for a prefilled drink bag, a hydratable drink bag, and a solid food stick. In addition, a helmet feed port concept was considered for use with drink bags external to the suit. Volumetric models of the in-suit drink bag concepts, based on xEMU dimensions, indicate challenges of fitting formulations > 200 ml (equating to approximately 200 kcal). Astronaut feedback on the four concepts indicated that despite some individual preferences for inclusion of solid foods and helmet port designs, the prefilled drink bag concept was the most preferred. A prefilled drink bag can only be used if food safety and stability can be ensured, possibly requiring advancements in food delivery hardware. CONCLUSION The ability to meet the increased need for nutrition during surface EVAs through provision of nutrients in the suited configuration would benefit overall crew health, performance, and morale, and thus increase the likelihood of mission success. It is recommended that in-suit nutrition capabilities provide at least 400–600 kcal within the suit during EVAs lasting > 4 hours and that suit designs include a dedicated volume for food grade nutrition systems. The developed food system should either allow for 1) installation of prefilled (sealed sterile) liquid nutrition in the suit and provide a mechanism to break the seal at the time that consumption is desired or 2) demonstrate that the unsealed food product shelf life allows for safe consumption after at least 12 hours of EVA.

E L Dillon↗

Recommendations for Developing Space Suit Integrated Food Systems and Delivering Nutrition Before, During, and After Lunar EVA

INTRODUCTION Artemis missions will include a higher tempo and frequency of extravehicular activities (EVAs) than any previous space program. Because of the physical demands expected from the crew, future space suit designs are required to incorporate nutritional support to the astronauts during lunar surface EVAs lasting longer than 4 hours. The purpose of this project was to provide recommendations to aid the development of an in-suit system that can adequately, safely, and acceptably deliver nutrition to a crewmember while confined to a space suit during EVA. METHODS Physiological, logistical, and engineering aspects of potential in-suit nutrition approaches were assessed through literature reviews, assessments of commercial off the shelf (COTS) foods, suit volumetric modeling, and feedback from subject matter experts and crewmembers. Key driving factors in the development of in-suit nutrition requirements included how much and what type of nutrition should be included, what food formulations are appropriate and safe, what are inherent limitations of space suits, what are the potential risks to the crewmember in the suit, and what practices and preferences from astronauts should be considered. Design references were conceptualized and assessed for strengths and limitations as potential in-suit nutrition systems for surface EVA. RESULTS Acute exogenous energy demands vary greatly depending on activity intensity and duration, and partial energy replenishment (i.e., 60–80 kcal∙hr-1 of EVA, or 460–680 kcal for EVAs lasting up to 8 hours) during activities could improve performance, safety, and recovery. COTS foods capable of providing these energy requirements exist; however, no COTS foods have been identified that pass NASA flight standards for microbiological safety and stability. In-suit nutrition delivery design references that were considered included in-suit concepts for a prefilled drink bag, a hydratable drink bag, and a solid food stick. In addition, a helmet feed port concept was considered for use with drink bags external to the suit. Volumetric models of the in-suit drink bag concepts, based on xEMU dimensions, indicate challenges of fitting formulations > 200 ml (equating to approximately 200 kcal). Astronaut feedback on the four concepts indicated that despite some individual preferences for inclusion of solid foods and helmet port designs, the prefilled drink bag concept was the most preferred. A prefilled drink bag can only be used if food safety and stability can be ensured, possibly requiring advancements in food delivery hardware. CONCLUSION The ability to meet the increased need for nutrition during surface EVAs through provision of nutrients in the suited configuration would benefit overall crew health, performance, and morale, and thus increase the likelihood of mission success. It is recommended that in-suit nutrition capabilities provide at least 400–600 kcal within the suit during EVAs lasting > 4 hours and that suit designs include a dedicated volume for food grade nutrition systems. The developed food system should either allow for 1) installation of prefilled (sealed sterile) liquid nutrition in the suit and provide a mechanism to break the seal at the time that consumption is desired or 2) demonstrate that the unsealed food product shelf life allows for safe consumption after at least 12 hours of EVA.

space suit↗

A Simple, Revolutionary Approach to Waste Packaging Utilizing Proven Technology - 20201

Historically, removing hazardous waste from gloveboxes involves the use of bags as the primary containment method. This method can prove tedious, repetitive, and time consuming to ensure the process follows all safeguards required to contain the waste and mitigate any breach of containment. Layers of bags, yards of tape, and multiple filters are added to the waste stream in order to transfer the hazardous waste from the glovebox safely into the drum package. Then, finally, it can be shipped and disposed of. The process to cut, tie, and tape each bag for disposal involves manual effort by multiple operators. Following Administrative Safety Controls, good operators are able to safely perform those tasks; but, since the bag is the only confinement layer, incidents can occur. Operators, in some cases, are also at close proximity to this waste which may increase the risk of radiation exposure. Once the waste is transferred out through these bags, it is nearly impossible to remove packaged waste that may contain higher dosage levels, thus increasing drum disposal costs incurred by the facility. Exceeding the allowable radiation levels, and drums not fully filled, both contribute significantly to excess disposal costs. Central Research Laboratories (CRL), based in Red Wing Minnesota, has developed the Waste Drum Transfer System (WDTS) building upon the proven technology and containment of the Rapid Transfer Port (RTP) as an alternate, more efficient method of waste transfer. This solution consists of an RTP Alpha port mounted inside a glovebox and Beta assembly unit composed of a drum liner fitted inside a standard 55 gallon drum. The use of the Beta drum liner bypasses the typical use of bags, sleeves or tape to provide leak tight containment. The process to connect and disconnect a drum from the glovebox is achieved by the self-docking and rotating system controls of the RTP Alpha, all done with only one operator standing in an upright ergonomic position. This system also allows for greater flexibility in available Beta connection options, expanding the overall functionality of the system. This system can be disconnected and reconnected multiple times to maximize volume containment. This will minimize drum disposal costs and reduce the overall volume of waste output by more efficiently filling the drums. Radiation levels inside each drum can be monitored and adjusted more efficiently by operators utilizing the reconnect option. Minimal As Low As Reasonably Achievable (ALARA) levels are also achievable with this system. This paper will show how highly efficient packaging and disposal of hazardous waste can be accomplished in a cost-effective manner utilizing the proven RTP technology. Maximized operator productivity and safety, as well as minimized radiation dose exposure, are all attainable through the system's engineered controls. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of laminae count and manufacturing methods on mechanical properties of thin‐ply woven composites

Abstract Thin‐ply woven composites exhibit exceptional mechanical performance by delaying the onset of damage, making them suitable for high‐performance structural applications. This study outlines the impact of manufacturing techniques (vacuum bagging and hot pressing), ply count, and fiber waviness on the mechanical properties of aromatic thermosetting copolyester/carbon‐fiber (ATSP/CF) composites. The analysis encompasses several different ply counts, evaluating their effects on the in‐plane elastic modulus (0°–90°) and tensile strength. Results demonstrate that reducing the waviness (or crimp) ratio significantly enhances the in‐plane elastic modulus, with improvements up to 188%, highlighting the importance of fiber alignment. Vacuum bagging produced ply thicknesses from 128 to 58 μm for 1–36 plies, with in‐plane elastic moduli from 30.3 to 87.2 GPa, and 4‐ and 8‐ply samples showed approximately 40% higher stiffness than those made by hot pressing. ATSP resin with high thermal stability (up to 400°C) and recyclability was used. Furthermore, this study highlights the microstructural enhancements achieved through vacuum bagging, as revealed by scanning electron and optical microscopy, and micro‐computed tomography imaging. This paper provides insights into damage mitigation and achieving enhanced mechanical properties by controlling fiber waviness using vacuum bagging and higher ply count in thin‐ply ATSP/CF composites. Highlights Crimp ratio reduction enhances elastic in‐plane elastic modulus up to 188%. Vacuum bagging increases modulus over the hot pressing manufacturing method by 40%. Lowering thickness‐per‐ply increases failure strain from 0.8% to 1.2%. Explored the performance of a novel ATSP matrix with high recyclability and thermal stability.

Kushwaha, Shashank [The Grainger College of Engine↗