The diluter-demand oxygen system used during the international Himalayan expedition to Mount Everest.

The diluter-demand regulators are designed in such a way that as the individual inspires he simultaneously draws ambient air and pure oxygen from a tank into his mask. The size of the ambient air orifice is made directly proportional to the barometric pressure by use of a passive aneroid valve. As altitude increases the ambient air orifice is automatically made smaller and the individual inspires a greater proportion of oxygen.

Blume, F. D.↗

Effects of oxygen-augmented atmosphere on the immune response.

Antibovine serum albumin antibody and nonspecific protein production was evaluated in female rabbits (11-14.5 kg) housed in special cages ventilated with 20% or 40% oxygen at normal barometric pressure. Animals exposed to 40% oxygen do not show normal steady increase of serum antibody. Instead, their titers show a pattern of undershoot, overshoot, undershoot, and finally equilibration at a subnormal level; they have a depressed popliteal node polysome level and have an abnormally low proportion of membrane-bound polysomes. They also show reduced capability of popliteal nodes to synthesize protein (as expected from the reduced number of polysomes). However, the ratio of newly-synthesized specific antibody: nonspecific protein remains normal.

Guttman, H. N.↗

Data set for background investigation of atmospheric constituents for Cape Henry site: August 5-22, 1974

The laboratory was located within the Fort Story Military Reservation at Cape Henry between 5 August and 21 August 1974. Total sulfur, total hydrocarbons, NO, NO2, Nox, and O3 were monitored and reported as hourly averages. Visibility was measured using an integrating nephelometer and reported as hourly averages. Twenty-four hour averaged mass loading was determined using two high volume air samplers located on different levels (25' and 50') at the site. Temperature, wind speed, relative humidity, barometric pressure and solar radiation intensity were measured at the site or supplemented by readings taken by the U. S. Coast Guard at the Cape Henry Light House.

Source record↗

Evaluation testing of solid encapsulated microcircuits for space applications

Epoxy encapsulated microcircuits were subjected to various thermal, vibration, thermal cycling, and reduced barometric pressure stress tests to obtain electrical, environmental, and failure data. Analyses of the data were employed to derive information on environmental and operating design limits to determine the capability of encapsulated microcircuits to perform in space applications and environments. Seven different part types (four TTL, two CMOS, one linear) from five different manufacturers were subjected to single, multiple, and combinational environmental stress levels to determine: (1) what failure mechanisms are unique to encapsulated microcircuits; (2) how believable are suppliers claims of improved reliability, (3) what stress tests and screens can be used to identify potential early failure, and (4) what stress tests and screens should be avoided to prevent unwanted life degradation.

Robinson, D. D.↗

Paul Bert

This biographical article on Paul Bert highlights his studies on the physiology of respiration and barometric pressure and, in particular his contributions to the understanding of hypoxia, hyperoxia and anesthesia.

Colin, J.↗

Performance evaluation of the SAO VLG-11 atomic hydrogen masers

A new generation of frequency standards, the VLG-11 hydrogen maser, has been designed and built at the Smithsonian Astrophysical Observatory (SAO). A comprehensive series of environmental and short-term stability tests on three VLG-11 masers has been completed and evaluated. The test results reported here show substantial improvements over previous hydrogen masers in measured sensitivity to variations in ambient temperature, barometric pressure, and magnetic fields. The maser frequency stability, as represented by the two-sample (Allan) variance, has been measured for averaging times ranging from 1 to 100,00 seconds. The variance is lower than 1 x 10 to the -15th for averaging intervals between 1400 and 20,000 seconds. For times shorter than 4000 seconds, the measured stability data agree remarkably well with theoretical values calculated from thermal noise mechanisms and the 'noise within the linewidth' regime is clearly discernable in the data.

Levine, M. W.↗

Evaluation of modern hydrogen masers

The masers were tested for environmental sensitivities (magnetic field, temperature, barometric pressure) and long-term aging. Allan variance runs of 72 days were made in order to attain averaging times from several seconds to 1 million seconds. Auto- and cross-correlation techniques were used to determine the effects of uncontrolled parameters such as humidity. Three-cornered-hat and other data reduction techniques were used to determine the characteristics of the individual masers.

Kirk, A.↗

Ice depolarization on low-angle 2 GHz satellite downlinks

The impact of ice depolarization on the statistical performance of satellite downlinks were investigated. Propagation data recorded during 1979 and 1980 to see what impact of ice depolarization on link performance were analyzed. The effects on the cross polarization discrimination (XPD) statistics amounted to at most a 2 to 4 dB reduction in the XPD values which rain would have produced for a given percentage of time. Ice depolarization had no effect on the statistics of XPD values below the 0.01% level. Most of the severe ice depolarization events were associated with drops in barometric pressure and the passage of intense cold fronts through our area. Ice contents as the product of three individually undetermined quantities were defined: ice particle density, ice cloud thickness, and the average volume of the ice crystals. It is indicated that populations of ice particle with ice contents on the order of 0.002 m4/m3 are probably responsible for the lower values of measured XPD.

Stutzman, W. L.↗

Frequency standards for VLBI, present and future

During the last several years, J.P.L. has evaluated a number of different types of frequency standards. These evaluations include measurement of environmetal susceptibilities (barometric pressure, humidity, temperature and magnetic field) and evaluation of stability. Data from these tests are presented for quartz oscillators, rubidium vapor standards, cesium beam standards, hydrogen masers (active and passive) and a superconducting cavity stabilized oscillator. Data on reliability and mechanical ruggedness based on actual field use is also presented. A survey of new frequency standards, their likely performance and environmental characteristics is presented.

Sydnor, R. L.↗

Atmospheric effects on the underground muon intensity

It has previously been reported that the barometric pressure coefficient observed for muons at Poatina (vertical absorber depth 357 hg/sq cm) appears to be appreciably higher than would be expected from atmospheric absorption alone. There is a possibility that the effect is due to an upper atmospheric temperature effect arising from an inverse correlation of surface pressure with stratospheric temperature. A new proportional telescope is discussed which has been operating at Poatina since about the beginning of 83 and which has a long term stability suitable for studying variations of atmospheric origin.

Fenton, A. G.↗

Displacements of the earth's surface due to atmospheric loading - Effects of gravity and baseline measurements

Atmospheric mass loads and deforms the earth's crust. By performing a convolution sum between daily, global barometric pressure data and mass loading Green's functions, the time dependent effects of atmospheric loading, including those associated with short-term synoptic storms, on surface point positioning measurements and surface gravity observations are estimated. The response for both an oceanless earth and an earth with an inverted barometer ocean is calculated. Load responses for near-coastal stations are significantly affected by the inclusion of an inverted barometer ocean. Peak-to-peak vertical displacements are frequently 15-20 mm with accompanying gravity perturbations of 3-6 micro Gal. Baseline changes can be as large as 20 mm or more. The perturbations are largest at higher latitudes and during winter months. These amplitudes are consistent with the results of Rabbel and Zschau (1985), who modeled synoptic pressure disturbances as Gaussian functions of radius around a central point. Deformation can be adequately computed using real pressure data from points within about 1000 km of the station. Knowledge of local pressure, alone, is not sufficient. Rabbel and Zschau's hypothesized corrections for these displacements, which use local pressure and the regionally averaged pressure, prove accurate at points well inland but are, in general, inadequate within a few hundred kilometers of the coast.

Van Dam, T. M.↗

Fire-related medical science

Spacecraft fire safety may be improved by the use of a fire-retardant atmosphere in occupied spaces. Low concentrations of oxygen can protect humans from fire damage by reducing the rate and spread of combustion, but care must be taken to avoid the hypoxic effects of oxygen-lean atmospheres. Crews can live and work in 11 percent oxygen if barometric pressure were adjusted to maintain the partial pressure of oxygen above 16 kPa. Eleven percent oxygen should prevent most types of fires, since 15 percent oxygen retards the combustion of paper and 13 percent oxygen extinguishes pentane flames. Test results indicate that seated humans can perform mental tasks in atmospheres containing 11.5 percent oxygen. Although this strategy of fire safety is under consideration for submarines, it could be adapted to spacecraft once operational procedures define a maximum hyperbaric pressure and fire research defines the effects of reduced oxygen concentrations on combustion in low gravity environments.

Knight, Douglas R.↗

Operating and environmental characteristics of Sigma Tau hydrogen masers used in the Very Long Baseline Array (VLBA)

Presented here are the results obtained from performance evaluation of a pair of Sigma Tau Standards Corporation Model VLBA-112 active hydrogen maser frequency standards. These masers were manufactured for the National Radio Astronomy Observatory (NRAO) for use on the Very Long Baseline Array (VLBA) project and were furnished to the Jet Propulsion Laboratory (JPL) for the purpose of these tests. Tests on the two masers were performed in the JPL Frequency Standards Laboratory (FSL) and included the characterization of output frequency stability versus environmental factors such as temperature, humidity, magnetic field, and barometric pressure. The performance tests also included the determination of phase noise and Allan variance using both FSL and Sigma Tau masers as references. All tests were conducted under controlled laboratory conditions, with only the desired environmental and operational parameters varied to determine sensitivity to external environment.

Tucker, T. K.↗

The physics of the environmental sensitivity of rubidium gas cell atomic frequency standards

Environmental sensitivity is often the most significant limitation to the practical stability of rubidium frequency standards (RFS). For example, temperature sensitivity can cause a rapid frequency change of several parts in 10(exp 10) for a tactical RFS that has an aging of only 1 times 10(exp -11)/month. Other important environmental factors are barometric pressure, vibration, magnetic field, and nuclear radiation. The physical mechanisms that lie behind these environmental sensitivities are considered. These physical mechanisms are related to the performance of actual rubidium frequency standards. For the user of these devices, a better knowledge of the causes for Rb clock instability will aid in their testing and proper application. For the time frequency specialist, a review of these factors may prove useful toward improving RFS design. Some of the RFS environmental sensitivities are due to simple physical mechanisms like the effect of dc magnetic field on the Rb hyperfine resonance frequency. For these, an analysis can be based on physical principles and straightforward design factors. Other environment factors, like temperature sensitivity, are more complex combinations of many effects, both physical and practical, and the analysis often takes the form of an error budget with large unit-to-unit variations. Today's rubidium frequency standards span a wide performance range from small, inexpensive units with pp 10(exp 10) error budgets to larger, higher performance versions offering pp 10(exp 10) stabilities. For both extremes, however, environmental sensitivity can be the most significant performance limitation. Why this is the case and how to make improvements are discussed.

Riley, William J.↗

Tracking performance with two breathing oxygen concentrations after high altitude rapid decompression

Current military aircraft Liquid Oxygen (LOX) systems supply 99.5 pct. gaseous Aviator's Breathing Oxygen (ABO) to aircrew. Newer Molecular Sieve Oxygen Generation Systems (MSOGS) supply breathing gas concentration of 93 to 95 pct. O2. The margin is compared of hypoxia protection afforded by ABO and MSOGS breathing gas after a 5 psi differential rapid decompression (RD) in a hypobaric research chamber. The barometric pressures equivalent to the altitudes of 46000, 52000, 56000, and 60000 ft were achieved from respective base altitudes in 1 to 1.5 s decompressions. During each exposure, subjects remained at the simulated peak altitude breathing either 100 or 94 pct. O2 with positive pressure for 60 s, followed by a rapid descent to 40000 ft. Subjects used the Tactical Life Support System (TLSS) for high altitude protection. Subcritical tracking task performance on the Performance Evaluation Device (PED) provided psychomotor test measures. Overall tracking task performance results showed no differences between the MSOGS breathing O2 concentration of 94 pct. and ABO. Significance RMS error differences were found between the ground level and base altitude trials compared to peak altitude trials. The high positive breathing pressures occurring at the peak altitudes explained the differences.

Nesthus, Thomas E.↗

Full scale determination of the lift and drag of a seaplane

The speed, barometric pressure, and number of revolutions of the engine of a seaplane were measured, including tests with stopped engine. The mean data obtained are given in the following note; the results of the gliding tests are used for the computation of the lift and drag coefficients, and by making use of them the results of the engine flights are used for the computation of the propeller efficiency.

Munk, Max M↗