Search NASA⌕ Search

SEARCH · Search NASA

Results for “Batch Correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Low-Activity Waste Glass Standards Preparation and Characterization for Calibration of Analytical Instruments

A matrix of seven low-activity waste (LAW) glasses was fabricated and characterized to be used by the Hanford Waste Treatment and Immobilization Plant (WTP) as analytical instrument calibration and matrix interference standards when measuring LAW glass compositions. The matrix of glasses was designed to represent the range of LAW glass compositions that will be generated by the WTP. Samples from each of the seven glasses were measured with electron probe microanalysis (EPMA), ion chromatography (IC), and bulk inductively coupled plasma mass spectroscopy (ICP-MS) to determine the variability and accuracy across batches and within individually poured glass bar samples. High relative percent differences and standard deviations were calculated for components with low concentrations due to instrument detection limits. IC and ICP-MS percent differences and standard deviations were higher at low component concentrations. Otherwise, variability in measured compositions from IC and ICP-MS was generally lower than measurements from EPMA, with the exclusion of Cl, F, Si, and B. Overall, the two methods proved comparable and complementary. From EPMA, IC, and ICP-MS data, volatile elements were underrepresented compared to batched compositions, which suggested loss of these elements during melting. EPMA data was statistically analyzed to evaluate homogeneity within single bars and whole compositions for each of the seven glasses. Most of the variability within glass compositions occurred at the bar-to-bar level; however, no clear systematic trends were observed. Based on these analyses, when using these glasses as reference material, it is recommended that the overall mean and variance of each composition be used for performing instrument calibrations and analytical corrections.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Time-resolved laser-induced desorption spectroscopy (LIDS) for quantified in-situ hydrogen isotope retention measurement and removal from plasma facing materials

A laboratory scale laser induced thermal desorption spectroscopy system is developed and tested on tungsten-deuterium and titanium-deuterium codeposits, and its feasibility as a hydrogenic inventory measurement diagnostic is demonstrated over a range of retention values from 5 × 10 19 m -2 to 7 × 10 23 m -2 for absorbed laser power densities as low as 8 MW m -2 . Codeposit layer samples are grown by magnetron sputtering and immersed in a weak argon rf plasma. A 1 kW fiber laser (λ = 1100 nm) heats the samples up to a peak surface temperature ranging from 900 to 1500 K using pulse widths of 0.5 and 1 s. Spectral line emission from Balmer series Dα and Hα from thermally desorbed deuterium and hydrogen, as well as line emission from argon, are monitored as a function of time using an optical spectrometer with maximum temporal resolution of 1 ms. To correct for wall recycling and pumping speed, and to accurately measure the time evolution of the laser-induced thermal desorption, the raw Dα signal is deconvolved with the system response function, which is obtained by injecting a short burst of D 2 to approximate an impulse. Calibration is done with a standard D 2 leak, and laser induced desorption spectroscopy deuterium retention values are found to be in good agreement with companion measurements made using conventional temperature programmed desorption on samples from the same codeposit batch.

36 MATERIALS SCIENCE↗

DynamicME: dynamic simulation and refinement of integrated models of metabolism and protein expression

Background Genome-scale models of metabolism and macromolecular expression (ME models) enable systems-level computation of proteome allocation coupled to metabolic phenotype. Results We develop DynamicME, an algorithm enabling time-course simulation of cell metabolism and protein expression. DynamicME correctly predicted the substrate utilization hierarchy on a mixed carbon substrate medium. We also found good agreement between predicted and measured time-course expression profiles. ME models involve considerably more parameters than metabolic models (M models). We thus generate an ensemble of models (each model having its rate constants perturbed), and then analyze the models by identifying archetypal time-course metabolite concentration profiles. Furthermore, we use a metaheuristic optimization method to calibrate ME model parameters using time-course measurements such as from a (fed-) batch culture. Finally, we show that constraints on protein concentration dynamics (“inertia”) alter the metabolic response to environmental fluctuations, including increased substrate-level phosphorylation and lowered oxidative phosphorylation. Conclusions Overall, DynamicME provides a novel method for understanding proteome allocation and metabolism under complex and transient environments, and to utilize time-course cell culture data for model-based interpretation or model refinement.

Mathematical & Computational Biology↗

A Data Exploration Tool for Large Sets of Spectra

We present an exploration tool for very large spectrum data sets such as the SDSS (Sloan Digital Sky Survey), LAMOST (Large Sky Area Multi-Object Fiber Spectroscopic Telescope), and 4MOST (4-meter Multi-Object Spectroscopic Telescope) data sets. The tool works in two stages: the first uses batch processing and the second runs interactively. The latter employs the NASA hyperwall, a configuration of 128 workstation displays (8 by 16 array) controlled by a parallelized software suite running on NASA's Pleiades supercomputer. The stellar subset of the Sloan Digital Sky Survey, DR10, was chosen to show how the our tool may be used. In stage one, SDSS files for 569,740 stars are processed through our data pipeline. The pipeline fits each spectrum using an iterative continuum algorithm, distinguishing emission from absorption and handling molecular absorption bands correctly. It then measures 1659 discrete atomic and molecular spectral features that were carefully preselected based on their likelihood of being visible at some spectral type. The depths relative to the local continuum at each feature wavelength are determined for each spectrum: these depths, the local S/N (signal to noise ratio) level, and DR10-supplied variables such as magnitudes, colors, positions, and radial velocities are the basic measured quantities used on the hyperwall. In stage two, each hyperwall panel is used to display a 2-D scatter plot showing the depth of feature A vs the depth of feature B for all of the stars. A and B change from panel to panel. The relationships between the various (A,B) strengths and any distinctive clustering are immediately apparent when examining and inter-comparing the different panels on the hyperwall. The interactive software allows the user to select the stars in any interesting region of any 2-D plot on the hyperwall, immediately rendering the same stars on all the other 2-D plots in a unique color. The process may be repeated multiple times, each selection displaying a distinctive color on all the plots. At any time, the spectra of the selected stars may be examined in detail on a connected workstation display. We illustrate how our approach allows us to quickly isolate and examine such interesting stellar subsets as EMP (Extremely Metal‐Poor) stars, CV (Cataclymic Variable) stars and C (Carbon)-rich stars.

Data Exploration↗

Part 2: Forensic attribution profiling of Russian VX in food using liquid chromatography-mass spectrometry

This work is part two of a three-part series in this issue of a Sweden-United States collaborative effort towards the understanding of the chemical attribution signatures of Russian VX (VR) in synthesized samples and complex food matrices. We describe the sourcing of VR present in food based on chemical analysis of attribution signatures by liquid chromatography-tandem mass spectrometry (LC-MS/MS) combined with multivariate data analysis. Analytical data was acquired from seven different foods spiked with VR batches that were synthesized via six different routes in two separate laboratories. The synthesis products were spiked at a lethal dose into seven food matrices: water, orange juice, apple purée, baby food, pea purée, liquid eggs and hot dog. After acetonitrile sample extraction, the samples were analyzed by LC-MS/MS operated in MRM mode. A multivariate statistical calibration model was built on the chemical attribution profiles from 118 VR spiked food samples. Using the model, an external test-set of the six synthesis routes employed for VR production was correctly identified with no observable major impact of the food matrices to the classification. The overall performance of the statistical models was found to be exceptional (94%) for the test set samples retrospectively classified to their synthesis routes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Real-Time Parameter Estimation Using Output Error

Output-error parameter estimation, normally a post- ight batch technique, was applied to real-time dynamic modeling problems. Variations on the traditional algorithm were investigated with the goal of making the method suitable for operation in real time. Im- plementation recommendations are given that are dependent on the modeling problem of interest. Application to ight test data showed that accurate parameter estimates and un- certainties for the short-period dynamics model were available every 2 s using time domain data, or every 3 s using frequency domain data. The data compatibility problem was also solved in real time, providing corrected sensor measurements every 4 s. If uncertainty corrections for colored residuals are omitted, this rate can be increased to every 0.5 s.

Grauer, Jared A.↗

MAUS: the MICE analysis user software

The Muon Ionization Cooling Experiment (MICE) collaboration has developed the MICE Analysis User Software (MAUS) to simulate and analyze experimental data. It serves as the primary codebase for the experiment, providing for offline batch simulation and reconstruction as well as online data quality checks. The software provides both traditional particle-physics functionalities such as track reconstruction and particle identification, and accelerator physics functions, such as calculating transfer matrices and emittances. The code design is object orientated, but has a top-level structure based on the Map-Reduce model. This allows for parallelization to support live data reconstruction during data-taking operations. MAUS allows users to develop in either Python or C++ and provides APIs for both. Various software engineering practices from industry are also used to ensure correct and maintainable code, including style, unit and integration tests, continuous integration and load testing, code reviews, and distributed version control. The software framework and the simulation and reconstruction capabilities are described.

47 OTHER INSTRUMENTATION↗

Assessment of Core Physics Characteristics of Extended Enrichment and Higher Burnup LWR Fuels using the Polaris/PARCS Two-Step Approach. Vol. I: PWR Fuel

Nuclear fuel with extended enrichment (235U enrichment within 5-8 wt%) is one of the evolutionary changes that have been pursued in recent years by commercial light water reactor operators and fuel vendors to improve the fuel cycle economy and operation performance of a nuclear plant. This work assesses the performance of the Polaris/PARCS two-step approach in core physics modeling of the pressurized water reactor cores with extended enrichment fuel, referred to as “LEU+” in this report. A representative LEU+ core with a 24-month fuel cycle developed by Southern Nuclear Company (SNC) was modeled using this two-step approach. A representative LEU core with an 18-month fuel cycle was also modeled to provide a reference for the LEU+ core. As expected, significantly more burnable poison absorbers were used in the LEU+ core to accomodate its higher fuel enrichment. Nine different fuel assembly types were modeled using Polaris for each core to generate the assembly cross sections, which were then processed by GenPMAX to prepare the cross-section data for PARCS. The average specific powers of each fuel batch in each core were derived from VERA results and higher specific powers in fresh assemblies were found in the LEU core due to its less total uranium loading included in the VERA LEU model, given that the total core power was assumed to be the same for both cores. PARCS models were developed to simulate the steady-state operations of both cores. PARCS results on the LEU+ core were first compared with the VERA results for verification purpose; good agreements were seen in soluble boron and burnup distribution results, indicating that the Polaris/PARCS modeling and simulation were correctly implemented. Core physics parameters calculated by PARCS, at zero power physics tests, beginning of cycle (BOC), and end of cycle conditions (EOC), were compared between the LEU+ core and the LEU core, including soluble boron concentration, burnup distributions, assembly and pin power peaking factors, fuel temperature reactivity coefficients, moderator temperature and density reactivity coefficients, control rod worth, and shut down margin. The main differences in PARCS results between the LEU+ and the LEU cores are summarized below: 1)The critical boron concentrations were found to be much higher in the LEU+ core than in the LEU core (1582 vs. 1335 ppm for peak values). 2)Higher assembly radial power peaking factors (1.4 vs. 1.3 for peak values), 2D pin peaking factors (1.53 vs. 1.42 for peak values), and 3D pin peaking factors (1.89 vs. 1.81 for peak values) were found in the LEU+ core than in the LEU core. 3)Significantly higher reactivity coefficients of moderator temperature (and density) were found in LEU+ than in LEU.4)Significantly lower control rod worth at EOC were found in LEU+ than LEU for all but one control banks.5)Significantly lower shut down margins were found in the LEU+ core than in the LEU core. The Polaris/GenPMAX/PARCS code suite was found to be capable of modeling the LEU+ PWR core for steady-state operations and no unexpected results in core physics parameters were observed, in spite of that a) several bugs in PARCS were identified and workarounds were used; b) several features were found lacking in the current version of PARCS that would be useful for core modeling. A list of requests for bug fixes and feature upgrades for PARCS originated from this work were transmitted to the code developers. The assessments on the performance of the Polaris/PARCS two-step approach in core modeling for boiling water reactor with LEU+ fuel is ongoing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An Empirical State Error Covariance Matrix Orbit Determination Example

State estimation techniques serve effectively to provide mean state estimates. However, the state error covariance matrices provided as part of these techniques suffer from some degree of lack of confidence in their ability to adequately describe the uncertainty in the estimated states. A specific problem with the traditional form of state error covariance matrices is that they represent only a mapping of the assumed observation error characteristics into the state space. Any errors that arise from other sources (environment modeling, precision, etc.) are not directly represented in a traditional, theoretical state error covariance matrix. First, consider that an actual observation contains only measurement error and that an estimated observation contains all other errors, known and unknown. Then it follows that a measurement residual (the difference between expected and observed measurements) contains all errors for that measurement. Therefore, a direct and appropriate inclusion of the actual measurement residuals in the state error covariance matrix of the estimate will result in an empirical state error covariance matrix. This empirical state error covariance matrix will fully include all of the errors in the state estimate. The empirical error covariance matrix is determined from a literal reinterpretation of the equations involved in the weighted least squares estimation algorithm. It is a formally correct, empirical state error covariance matrix obtained through use of the average form of the weighted measurement residual variance performance index rather than the usual total weighted residual form. Based on its formulation, this matrix will contain the total uncertainty in the state estimate, regardless as to the source of the uncertainty and whether the source is anticipated or not. It is expected that the empirical error covariance matrix will give a better, statistical representation of the state error in poorly modeled systems or when sensor performance is suspect. In its most straight forward form, the technique only requires supplemental calculations to be added to existing batch estimation algorithms. In the current problem being studied a truth model making use of gravity with spherical, J2 and J4 terms plus a standard exponential type atmosphere with simple diurnal and random walk components is used. The ability of the empirical state error covariance matrix to account for errors is investigated under four scenarios during orbit estimation. These scenarios are: exact modeling under known measurement errors, exact modeling under corrupted measurement errors, inexact modeling under known measurement errors, and inexact modeling under corrupted measurement errors. For this problem a simple analog of a distributed space surveillance network is used. The sensors in this network make only range measurements and with simple normally distributed measurement errors. The sensors are assumed to have full horizon to horizon viewing at any azimuth. For definiteness, an orbit at the approximate altitude and inclination of the International Space Station is used for the study. The comparison analyses of the data involve only total vectors. No investigation of specific orbital elements is undertaken. The total vector analyses will look at the chisquare values of the error in the difference between the estimated state and the true modeled state using both the empirical and theoretical error covariance matrices for each of scenario.

Frisbee, Joseph H., Jr.↗

SU-E-J-84: Quantitative Dosimetry Assessment of the Impact of Image Artifacts of Metal Implants in Spinal SABR Treatment

Purpose: Metal rods are frequently used to stabilize the spine in patients with metastatic disease. The high Z material causes imaging artifacts in the surrounding tissue in CT scans, which introduces dosimetric uncertainty when inhomogeneity correction is enabled for radiation treatment planning. The purpose of this study is to quantify the dosimetric deviations caused by the imaging artifacts and to evaluate the effectiveness of using Hounsfield units (HU) overwriting to reduce dosimetric uncertainties. Methods: We retrospectively reviewed treatment plans for 4 patients with metal implants who received stereotactic ablative radiation therapy (SABR) for metastatic disease to the spine on Tomotherapy HiArt. For all four patients, the region of imaging artifact surrounding the metal implants was contoured and the pixel HU’s were overwritten to be water equivalent. We then generated adaptive treatment plans for these patients using the MVCT pretreatment set up images and batched beamlets in the original treatment plans. The dosimetry deviation between the adaptive and original plans were compared and quantitatively analyzed. Results: For three out of four patient, the major OAR (spinal cord) dose (0.35cc or 10% according to protocols and fractionation) increased (2.7%, 5.5%, 0%, 3.9%, mean=3.0±2.3%, p=0.04), and the PTV dose (D90 or D95 as per prescription) increased for all four patients ( 2%, 5%, 0.7%, 3.6%, mean=2.8±1.9%, p=0.03) in the adaptive plan with HU overwriting. The average point dose deviation of the Tomotherapy DQA for the same patients was −1.0±1.0%. For plans without HU overwriting, the dose deviation from the treatment plan will increase. Conclusion: The metal implant and the imaging artifacts may cause a significant dosimetric impact on radiation treatment plans for spinal disease. The dose to the PTV and the spinal cord was under-calculated in treatment plans without considering the imaging artifacts. HU overwriting can reduce the dosimetry un-certainty.

60 APPLIED LIFE SCIENCES↗

Analysis of filter tuning techniques for sequential orbit determination

This paper examines filter tuning techniques for a sequential orbit determination (OD) covariance analysis. Recently, there has been a renewed interest in sequential OD, primarily due to the successful flight qualification of the Tracking and Data Relay Satellite System (TDRSS) Onboard Navigation System (TONS) using Doppler data extracted onboard the Extreme Ultraviolet Explorer (EUVE) spacecraft. TONS computes highly accurate orbit solutions onboard the spacecraft in realtime using a sequential filter. As the result of the successful TONS-EUVE flight qualification experiment, the Earth Observing System (EOS) AM-1 Project has selected TONS as the prime navigation system. In addition, sequential OD methods can be used successfully for ground OD. Whether data are processed onboard or on the ground, a sequential OD procedure is generally favored over a batch technique when a realtime automated OD system is desired. Recently, OD covariance analyses were performed for the TONS-EUVE and TONS-EOS missions using the sequential processing options of the Orbit Determination Error Analysis System (ODEAS). ODEAS is the primary covariance analysis system used by the Goddard Space Flight Center (GSFC) Flight Dynamics Division (FDD). The results of these analyses revealed a high sensitivity of the OD solutions to the state process noise filter tuning parameters. The covariance analysis results show that the state estimate error contributions from measurement-related error sources, especially those due to the random noise and satellite-to-satellite ionospheric refraction correction errors, increase rapidly as the state process noise increases. These results prompted an in-depth investigation of the role of the filter tuning parameters in sequential OD covariance analysis. This paper analyzes how the spacecraft state estimate errors due to dynamic and measurement-related error sources are affected by the process noise level used. This information is then used to establish guidelines for determining optimal filter tuning parameters in a given sequential OD scenario for both covariance analysis and actual OD. Comparisons are also made with corresponding definitive OD results available from the TONS-EUVE analysis.

Lee, T.↗

Optimization of Beidellite/Polyaniline Production Conditions by Central Composite Design for Removal of Acid Yellow 194

In the adsorption process, the adsorbent structure and its interaction with wastewater are the main determinant of the process efficiency. For this reason, the correct selection of the production conditions for the produced adsorbents is critical. In this study, the reaction time and the concentration of acid, oxidant, substrate, and monomer were selected as independent variables which effect the structure of the polyaniline based composite material. These production variables of polyaniline/beidellite (PANI/BEI) composites were designed by response surface methodology (RSM). According to RSM, 46 different PANI/BEI composites were synthesized and were used as an adsorbent in the removal of acid yellow 194. Thus, the optimum PANI/BEI production conditions were determined. After the identification of the optimum PANI/BEI production conditions, the effect of adsorption conditions such as pH, mixing time, and dye concentration were studied by batch experiments. The maximum adsorption capacity was obtained as 123 (mg g{sup −1}) at the T = 25 °C, t = 24 h, pH 3, m{sub s} = 0.15 g adsorbent, V{sub s} = 50 ml dye solution, and ω = 200 rpm. The results presented in this study revealed that the central composite design is a suitable method to optimize the production conditions of PANI/BEI and the prepared PANI/BEI composites has an important potential as an adsorbent for the removal of metal-complex dyes such as AY194. In addition, the polymerization of aniline and the removal of dye were confirmed by different analytical techniques such as BET, XRD, SEM, and EDAX.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Development and Implementation of Non-Newtonian Rheology Into the Generalized Fluid System Simulation Program (GFSSP)

One of the goals of this program was to develop the experimental and analytical/computational tools required to predict the flow of non-Newtonian fluids through the various system components of a propulsion system: pipes, valves, pumps etc. To achieve this goal we selected to augment the capabilities of NASA's Generalized Fluid System Simulation Program (GFSSP) software. GFSSP is a general-purpose computer program designed to calculate steady state and transient pressure and flow distributions in a complex fluid network. While the current version of the GFSSP code is able to handle various systems components the implicit assumption in the code is that the fluids in the system are Newtonian. To extend the capability of the code to non-Newtonian fluids, such as silica gelled fuels and oxidizers, modifications to the momentum equations of the code have been performed. We have successfully implemented in GFSSP flow equations for fluids with power law behavior. The implementation of the power law fluid behavior into the GFSSP code depends on knowledge of the two fluid coefficients, n and K. The determination of these parameters for the silica gels used in this program was performed experimentally. The n and K parameters for silica water gels were determined experimentally at CFDRC's Special Projects Laboratory, with a constant shear rate capillary viscometer. Batches of 8:1 (by weight) water-silica gel were mixed using CFDRC s 10-gallon gelled propellant mixer. Prior to testing the gel was allowed to rest in the rheometer tank for at least twelve hours to ensure that the delicate structure of the gel had sufficient time to reform. During the tests silica gel was pressure fed and discharged through stainless steel pipes ranging from 1", to 36", in length and three diameters; 0.0237", 0.032", and 0.047". The data collected in these tests included pressure at tube entrance and volumetric flowrate. From these data the uncorrected shear rate, shear stress, residence time, and viscosity were evaluated using formulae for non-Newtonian, power law fluids. The maximum shear rates (corrected for entrance effects) obtained in the rheometer with the current setup were in the 150,000 to 170,000sec- range. GFSSP simulations were performed with a flow circuit simulating the capillary rheometer and using Power Law gel viscosity coefficients from the experimental data. The agreement between the experimental data and the simulated flow curves was within +/-4% given quality entrance effect data.

DiSalvo, Roberto↗

Purification of Zirconium Tetrachloride from UNF Cladding

The overarching objective of this project was to design and demonstrate (laboratory scale) a sublimation-based purification protocol to obtain pure zirconium chloride (ZrCl 4 ) from impure feeds derived from the direct chlorination of Zircaloy cladding materials. To achieve this objective the following goals were identified. (1) Design, construct and test an apparatus capable of subliming and purifying ZrCl 4 at room pressure and temperatures between 600 and 700K (sublimation point of ZrCl 4 606 K). (2) Investigate reactions that may be used to chemically alter the makeup of the impure ZrCl 4 feed materials to enhance their removal from ZrCl 4 in the sublimation-purification process. (3) Computationally model the reactions of metal chlorides in the gas phase under sublimation conditions (1 atm, 600 K) to determine if oligomers are formed and, if formed, how they would influence sublimation-based purification strategies. All experimental investigations performed as part of this project used stable (non-radioactive) compounds and materials as surrogates for the impure ZrCl 4 feedstocks that would be derived from the direct chlorination of Zircaloy claddings from spent nuclear fuel rods. No radiologically active materials were used at any time in this project. The impure ZrCl 4 feedstocks used in this study were derived from the direct chlorination of virgin Zircaloy claddings (Zirc-2, -4 and high Nb). The main goals of the project have been achieved during the three year period of this NEUP sponsored project. The impurities of greatest concern in the feedstocks were identified as the chloride salts of the alloying metals originally found in Zircaloy (Fe, Nb) and radiological contaminants (Cs, Sr, and Sb). A series of prototype sublimation apparatuses and heating arrangements were designed, constructed and tested. A general batch-sublimator design was identified and a 1.0 kg batch sublimator/oven system was fabricated from glass. Purification protocols developed on small scale runs were found to scale to 1.0 kg batches without problem. Purification factor ranges (PFs: wt% final / wt% initial ) for the impurity chlorides identified above have been measured: Fe (40 – 500); Nb (10 – 70); Cs (520 – 5000); Sr (250 – 1900); Sb (220 – 2300). Removal of iron is sensitive to the partial pressure of hydrogen (in nitrogen) flowing through the system. Lower PFs are obtained when the hydrogen partial pressure is lower. Lower flows are required to raise the iron PF. Removal of niobium is very sensitive to the endpoint determination of the forerun. When judged properly (color change yellow to white in sublimate) reasonable PFs (500) can be achieved. However, as discussed in the conclusions section, endpoint determination can be difficult and significantly lower PFs may be obtained when the endpoint is not correctly identified. Several methods of obtaining quantitative cesium, strontium and antimony PFs were investigated, the best being ICP-MS. The results reported here reflect very limited access to and ICP-MS instrument during the course of this project. It should be noted that, while significantly reduced amounts of antimony are observed in the product, antimony is also found in the exhaust trap after the condenser. Quantum chemical computational modeling studies of the reactions of metal chlorides in the gas phase provided important information about a chemical transport mechanism that could defeat sublimation-based purification strategies. Many metal chlorides are known to oligomerize in the gas phase to reduce their coordinative unsaturation. Dimerization of ZrCl 4 with iron or niobium chlorides would provide a mechanism by which both metal impurities could be carried over with the product during sublimation of the bulk material. Computational modeling conclusively showed that under sublimation conditions in the gas phase, dimerization reactions are not favored thermodynamically due to a significant entropic penalty for the reaction. Therefore, consistent with experimental observations, sublimation-based purification strategies remain viable. The experimental part of the report concludes with a short discussion of the issues that still remain in developing a technologically relevant Zircaloy recycling strategy. The final section of the report is a summary of the quantum chemical investigation of the reactions of metal chlorides in the gas phase under sublimation conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Results Of Hg Speciation Testing On DWPF SMECT-1, SMECT-3, And SMECT-5 Samples

The Savannah River National Laboratory (SRNL) was tasked with preparing and shipping samples for Hg speciation by Eurofins Frontier Global Sciences, Inc. in Seattle, WA on behalf of the Savannah River Remediation (SRR) Mercury Task Team. The thirteenth shipment of samples was designated to include Defense Waste Processing Facility (DWPF) Slurry Mix Evaporator Condensate Tank (SMECT) from Sludge Receipt and Adjustment Tank (SRAT) Batch 736 and 738 samples. Triplicate samples of each material were prepared for this shipment. Each replicate was analyzed for seven Hg species: total Hg, total soluble (dissolved) Hg, elemental Hg [Hg(0)], ionic (inorganic) Hg [Hg(I) and Hg(II)], methyl Hg [CH 3 Hg-X, where X is a counter anion], ethyl Hg [CH 3 CH 2 -Hg-X, where X is a counter anion], and dimethyl Hg [(CH 3 ) 2 Hg]. The difference between the total Hg and total soluble Hg measurements gives the particulate Hg concentration, i.e. Hg adsorbed to the surface of particulate matter in the sample but without resolution of the specific adsorbed species. The average concentrations of Hg species in the aqueous samples derived from Eurofins reported data corrected for dilutions performed by SRNL are tabulated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Direct Feed Low Activity Waste Test Platform - Pretreatment Unit Operations - 18613

The Low-Activity Waste Pretreatment System (LAWPS) facility is planned to pretreat Hanford tank waste supernate by filtering solids and processing through ion exchange columns to remove cesium. Note that cesium ion exchange is not discussed in this paper. The filtration process is achieved through cross flow filtration using a stainless steel Mott filter with a 0.1-micron grade. The goal of this effort was to assess whether a batch, or dead end, filtration (DEF) device replicating the LAWPS cross flow filter could be employed to qualify each feed campaign prior to delivery to LAWPS. The objective for filtration feed qualification is to determine whether the cross flow filters deployed in LAWPS will remove solids while maintaining a de minimis flow rate of permeate. To that end, the DEF was tested with simulants and the results compared with those obtained from cross flow filtration tests. In addition, actual waste samples were retrieved from Hanford Site Tank AP-105 and were composited for testing. These composited samples were first tested with cross flow filtration to determine the filter flux under typical LAWPS conditions. The same material was subsequently tested with DEF to determine a filter flux. While the DEF correctly predicted the cross flow filter's ability to filter solids from the feed, there was limited correlation between DEF and cross flow filtration flux results. This lack of correlation suggests a fundamental difference between cross flow filtration and DEF as used in these tests. Taken in total, these results indicate that DEF is not a good candidate to provide qualification of feed for LAWPS cross flow filtration. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Direct Feed High-Level Waste APPS Model Glass Testing (DFHLW APPS) Matrix

This report summarizes the data collected during the batching and melting of the Direct Feed High-Level Waste APPS Model Glass Matrix (DFHLW APPS) to serve as a quality-assured validation of the Aspen Process Performance Simulation (APPS) formulation method. Of 15 glasses tested, 12 satisfied all target property constraints. Two glasses, APPS-05 and -06, formed nepheline on canister centerline cooling heat-treatment and failed the Product Consistency Test response limits. Glass APPS-07-2 formed unacceptably high concentrations of crystals (primarily Na3Nd(PO4)2) when heat treated at 950 °C. All other glasses were found to be satisfactory. The measured property values were compared to predicted values from a set of current models. In many cases the current models were found to be inadequate for design of DFHLW glasses. These models are being adjusted to correct for mispredictions. Other models, e.g., density, toxicity characteristic leaching procedure, and sulfur solubility, are adequate for formulation of DFHLW glasses.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Colored noise effects on batch attitude accuracy estimates

The effects of colored noise on the accuracy of batch least squares parameter estimates with applications to attitude determination cases are investigated. The standard approaches used for estimating the accuracy of a computed attitude commonly assume uncorrelated (white) measurement noise, while in actual flight experience measurement noise often contains significant time correlations and thus is colored. For example, horizon scanner measurements from low Earth orbit were observed to show correlations over many minutes in response to large scale atmospheric phenomena. A general approach to the analysis of the effects of colored noise is investigated, and interpretation of the resulting equations provides insight into the effects of any particular noise color and the worst case noise coloring for any particular parameter estimate. It is shown that for certain cases, the effects of relatively short term correlations can be accommodated by a simple correction factor. The errors in the predicted accuracy assuming white noise and the reduced accuracy due to the suboptimal nature of estimators that do not take into account the noise color characteristics are discussed. The appearance of a variety of sample noise color characteristics are demonstrated through simulation, and their effects are discussed for sample estimation cases. Based on the analysis, options for dealing with the effects of colored noise are discussed.

Bilanow, Stephen↗