Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam sensitive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Freeze It or Leave It? Evaluating the Role of Cryo-Electron Microscopy in Battery Research

Cryogenic electron microscopy (cryo-EM) continues to gain prominence in materials science, particularly in battery research where it has enabled high-resolution, multimodal characterization of electrode materials and interfaces that otherwise degrade quickly under electron beam irradiation. But as anyone who has attempted cryo-EM techniques knows, freezing comes at a cost; cryo-EM experiments are time-consuming, highly sensitive, and carry an increased risk of artifacts due to issues such as frost contamination. Thus, when planning new characterization of battery materials or other beam-sensitive samples, it is critical to consider whether (and which) cryo-EM techniques are appropriate, based on study goals and an understanding of electron beam-sample interactions. Here we review such considerations for battery materials to elucidate the questions of when, why, and how to freeze to achieve high-quality characterization.

25 ENERGY STORAGE↗

Latchup in CMOS Integrated Circuits

Sensitivity to ion beams is studied. Latchup effect subject of paper presenting results of testing 19 types of complementary metal-oxide semiconductor (CMOS) chips from six manufacturers. Report gives details of sensitivity of chips to latchup caused by argon and krypton ion beams. Identifies parasitic npnp paths and proides latchup cross section and qualitative explanation of latchup sensitivity for each chip type.

Soliman, K. A.↗

BEAM COLLIMATION IN THE PIP-II LINAC TO BOOSTER TRANSFER LINE

The new PIP-II superconducting linac will deliver a 2 mA average H⁻ beam to the existing Booster synchrotron. The injected beam is accumulated by charge exchange over approximately 300 turns; phase space painting is used to mitigate space charge effects. To limit the power load on the internal waste beam absorber from the transverse tails of the H⁻ distribution missing the foil, the beam will be collimated in both planes in the linac to Booster transfer line using compact collimators of a novel design. Both the number of parasitic hits and the fraction of the beam missing the foil are sensitive functions of the H⁻ beam centroid position with respect to the edge of the foil. The positioning of the collimation is constrained by the availability of suitable space in the transfer line lattice, by specifics of the collimator design, by the phase space orientation at the collimator, and by the betatron phase advance to the foil needed to achieve proper orientation of the spatial distribution at the injection point. In this contribution, we describe the procedure by which collimator positions were optimized. We then discuss the expected performance of the overall system.

Johnson, David E.↗

Shot noise limits to sensitivity of optical interferometry

By arguing that the limiting noise is the photoelectron shot noise, we show that the sensitivity of image synthesis by an ideal optical interferometer is independent of the details of beam-splitting and recombination. The signal-to-noise ratio of the synthesized image is proportional to the square root of the total number of photoelectrons detected by the entire array. For non-ideal interferometers, which are forced to employ a closure-phase method of indirect inference of the visibility data, essentially the same result holds for strong sources, but at weak light levels beam-splitting degrades sensitivity.

Prasad, Sudhakar↗

Stability of beta-induced Alfvén eigenmodes (BAE) in DIII-D

Although the stability of ellipticity, toroidal and reversed-shear Alfvén eigenmodes (EAE, TAE, RSAE) are relatively well understood, less is known about the stability of lower-frequency modes such as the beta-induced Alfvén eigenmode (BAE) but, because they are often unstable in present devices and are implicated in fast-ion transport, understanding their stability is vital. BAE stability is studied in primarily weak or reversed shear DIII-D plasmas with sub-Alfvénic deuterium beams. Modes are classified based on electron cyclotron emission, beam emission spectroscopy, magnetics, and interferometer data. The study is limited to the initial two seconds of the discharge, where the evolving q profile provides an effective scan of the dependence of stability upon q. In a dedicated experiment, BAEs are unstable at times in the discharge when the minimum of the safety factor q min is close to a rational number. The observed mode frequencies are usually close to analytic estimates of the BAE accumulation point and the eigenfunction peaks in the vicinity of q min . Unstable BAEs usually occur in bursts that chirp rapidly in frequency. To isolate the importance of thermal and beam gradients in driving the modes, the beam and electron cyclotron heating power is altered for 50–100 ms durations in reproducible discharges. As expected from the resonance condition, BAEs depend sensitively on the beam power and injection geometry. Modes only persist for ~25 ms because the anisotropic beam population only interacts strongly with the modes over a relatively narrow range of q. Lastly, a database of over 1000 beam-heated discharges shows that BAEs are more likely to be unstable when the poloidal beta exceeds 0.5.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reflection type skin friction meter

A housing block is provided having an upper surface conforming to the test surface of a model or aircraft. An oil film is supplied upstream of a transparent wedge window located in this upper surface by an oil pump system located external to the housing block. A light source located within the housing block supplies a light beam which passes through this transparent window and is reflected back through the transparent window by the upper surface of the oil film to a photo-sensitive position sensor located within the housing. This position sensor allows the slope history of the oil film caused by and aerodynamic flow to be determined. The skin friction is determined from this slope history. Internally located mirrors augment and sensitize the reflected beam as necessary before reaching the position sensor. In addition, a filter may be provided before this sensor to filter the beam.

Bandyopadhyay, Promode R.↗

Population Studies of Radio and Gamma-Ray Pulsars

Rotation-powered pulsars are one of the most promising candidates for at least some of the 40-50 EGRET unidentified gamma-ray sources that lie near the Galactic plane. Since the end of the EGRO mission, the more sensitive Parkes Multibeam radio survey has detected mere than two dozen new radio pulsars in or near unidentified EGRET sources, many of which are young and energetic. These results raise an important question about the nature of radio quiescence in gamma-ray pulsars: is the non-detection of radio emission a matter of beaming or of sensitivity? The answer is very dependent on the geometry of the radio and gamma-ray beams. We present results of a population synthesis of pulsars in the Galaxy, including for the first time the full geometry of the radio and gamma-ray beams. We use a recent empirically derived model of the radio emission and luminosity, and a gamma-ray emission geometry and luminosity derived theoretically from pair cascades in the polar slot gap. The simulation includes characteristics of eight radio surveys of the Princeton catalog plus the Parkes MB survey. Our results indicate that EGRET was capable of detecting several dozen pulsars as point sources, with the ratio of radio-loud to radio-quiet gamma-ray pulsars increasing significantly to about ten to one when the Parkes Survey is included. Polar cap models thus predict that many of the unidentified EGRET sources could be radio-loud gamma- ray pulsars, previously undetected as radio pulsars due to distance, large dispersion and lack of sensitivity. If true, this would make gamma-ray telescopes a potentially more sensitive tool for detecting distant young neutron stars in the Galactic plane.

Harding, Alice K↗

Status of Error Correction Studies in Support of FFA@CEBAF

In this work, we examine the beam correction requirements for the FFA@CEBAF energy upgrade. Both hardware and software diagnostic and corrector components are under investigation; in particular the relationship between hardware and software optimization will be developed. To generate a representative sample of errors---from the machine lattice and other beam properties---we construct a Markov Chain Monte Carlo (MCMC) sampler which considers different probability distributions for different types of errors. This sample is used to investigate the statistical sensitivity of the beam to various diagnostic and corrective schema. Once statistics are acquired, we plan to use a variety of optimization techniques to minimize correction time for the electron beam in the FFA arcs designed for the CEBAF upgrade.

Benesch, J.↗

An analysis of the phase dispersion in the symmetric beam combiner

An astronomical beam combiner combines the two beams of starlight to form white-light fringes. It is desirable that the dispersion of the beam combiner be minimized across the observation wavelength range. We present here an analysis of the phase dispersion from coatings for a symmetric beam combiner. The sensitivity of the dispersion to a slight mismatch in beamsplitter coatings is also studied.

coatings↗

Sensitivity study for a remotely piloted microwave-powered sailplane used as a high-altitude observation

The sensitivity of several performance characteristics of a proposed design for a microwave-powered, remotely piloted, high-altitude sailplane to changes in independently varied design parameters was investigated. Results were expressed as variations from baseline values of range, final climb altitude and onboard storage of radiated energy. Calculated range decreased with increases in either gross weight or parasite drag coefficient; it also decreased with decreases in lift coefficient, propeller efficiency, or microwave beam density. The sensitivity trends for range and final climb altitude were very similar. The sensitivity trends for stored energy were reversed from those for range, except for decreasing microwave beam density. Some study results for single parameter variations were combined to estimate the effect of the simultaneous variation of several parameters: for two parameters, this appeared to give reasonably accurate results.

Turriziani, R. V.↗

Optimization and active stabilization of a far-infrared laser for NSTX-U high poloidal wavenumber scattering diagnostics

The far-infrared (FIR) laser output beam power and profile are important parameters in the laser-aided diagnostics, directly influencing the spatial resolution and signal-to-noise ratio of measurements. Here, this work focuses on developing a systematic control method to enhance FIR laser beam quality through optimized mirror alignment and real-time feedback-based precision cavity length tuning. A 150 W CO 2 laser, aligned with the waveguide axis using a HeNe reference laser, serves as the pump source. The sensitivity of FIR beam intensity to pump gas pressure and thermal expansion is investigated, revealing that even a 1 µm cavity expansion can significantly degrade output power stability to about two-thirds of its original value. To address this, a feedback control module has been designed and implemented for active cavity length adjustment, stabilizing the output power at ∼30 mW. In addition, maintaining a high formic acid gas pressure ($>$190 mTorr) within the cavity ensures reliable operation. The optimized FIR laser will be deployed on the National Spherical Torus eXperiment-U high poloidal wavenumber scattering system for studying electron-scale turbulence in tokamak plasmas.

Xu, Xinhang [Univ. of California, Davis, CA (Unite↗

Model study of the energy dependence of the correlation between anisotropic flow and the mean transverse momentum in Au + Au collisions

A hybrid model that employs the hadron-string transport model UrQMD and the (3+1)-dimensional relativistic viscous hydrodynamic code vHLLE, is used to investigate the beam energy dependence of the correlation coefficient ρ(v$^{2}_{2}$,[p T ]) between the average transverse momentum [p T ] of hadrons emitted in an event and the square of the anisotropic flow coefficient v$^{2}_{2}$. For Au+Au collisions, the model predicts characteristic patterns for the energy and event-shape dependence of the variances for [p T ] and v$^{2}_{n}$ [Var([p T ] and Var(v$^{2}_{2}$)], and the covariance of v$^{2}_{n}$ and [p T ][cov(v$^{2}_{2}$,[p T ])], consistent with the attenuation effects of the specific shear viscosity η/s. Here in contrast, ρ(v$^{2}_{2}$,[p T ]) is predicted to be insensitive to the beam energy but sensitive to the initial-state geometry of the collisions. These observations suggest that a precise set of measurements for Var([p T ]), Var(v$^{2}_{2}$), cov(v$^{2}_{2}$,[p T ]) and ρ(v$^{2}_{2}$,[p T ]) as a function of beam energy and event shape, could serve to constrain better the eccentricities and their fluctuations over the entire span of beam energies, and consequently aid precision extraction of the temperature and baryon chemical-potential dependence of η/s from the wealth of Au+Au data obtained in the RHIC beam energy scan.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Enhanced Isomer Population via Direct Irradiation of Solid-Density Targets Using a Compact Laser-Plasma Accelerator

Excitation of long-lived states in bromine nuclei using a tabletop laser-plasma accelerator providing pulsed (<100 fs) electron beams provided a sensitive probe of γ strength and level densities in the nuclear quasicontinuum and may indicate angular momentum coupling through electron-nuclear interactions. Solid-density active $LaBr_{3}$ targets absorb real and virtual photons up to 35 ± 2.5 MeV and deexcite through γ cascade into different states. Here, a factor of 4.354 ± 0.932 enhancement of the $^{80}Br^{m}/^{80}Br^{g}$ isomeric ratio was observed following electron irradiation, as compared to bremsstrahlung. Additional angular momentum transfer could possibly occur through nuclear-plasma or electron-nuclear interactions enabled by the ultrashort electron beam. Further investigation of these mechanisms could have far-reaching impact including decreased storage of long-term nuclear waste and an improved understanding of heavy element formation in astrophysical settings.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Abrasion-fission reactions at intermediate energies

The availability of high-intensity, heavy-ion beams coupled to sensitive, large solid-angle acceptance spectrometers has enabled a detailed examination of the fission fragments produced in induced-fission reactions. The abrasion fission process involves the formation of projectile-like prefragments in violent nuclear collisions at relative energies in excess of 100 MeV/u. At intermediate energies below this threshold, experiments suggest a change in the prefragment kinematic qualities. Information regarding the influence of this transitional phase upon the evolution of nuclei approaching the point of scission is scarce. In this article, data are presented for over 200 nuclei from nickel to palladium produced in abrasion-fission reactions of a 80 MeV/u 238 U beam. Cross sections were obtained following yield measurements performed for the principal charge states of the identified fission fragments and a detailed analysis of the ion transmission. A full kinematic analysis of the fission fragments has been performed using the LISE ++ software package, where the trajectory of an ion passing through a spectrometer can be reconstructed based upon measurements at the focal plane. Furthermore, the results obtained at the S800 spectrograph are compared with predictions obtained with a three-fission progenitor (3EER) model. Systematic studies of fission-fragment properties continue to provide a valuable experimental benchmark for theoretical efforts directed toward describing this complex decay channel, that is important in the context of planning experiments to explore the neutron-rich region of the nuclear chart at rare-isotope beam facilities.

59 ≤ A ≤ 8990 ≤ A ≤ 149↗

Testing the Gamma-Ray Burst Energy Relationships

Building on Nakar & Piran's analysis of the Amati relation relating gamma-ray burst peak energies E(sub p) and isotropic energies E(sub iso ) we test the consistency of a large sample of BATSE bursts with the Amati and Ghirlanda (which relates peak energies and actual gamma-ray energies E(sub gamma)) relations. Each of these relations can be exp ressed as a ratio of the different energies that is a function of red shift (for both the Amati and Ghirlanda relations) and beaming fraction f(sub B) (for the Ghirlanda relation). The most rigorous test, whic h allows bursts to be at any redshift, corroborates Nakar & Piran's r esult - 88% of the BATSE bursts are inconsistent with the Amati relat ion - while only l.6% of the bursts are inconsistent with the Ghirlan da relation if f(sub B) = 1. Modelling the redshift distribution resu lts in an energy ratio distribution for the Amati relation that is sh ifted by an order of magnitude relative to the observed distributions; any sub-population satisfying the Amati relation can comprise at mos t approx. 18% of our burst sample. A similar analysis of the Ghirland a relation depends sensitively on the beaming fraction distribution f or small values of f(sub B); for reasonable estimates of this distrib ution about a third of the burst sample is inconsistent with the Ghir landa relation. Our results indicate that these relations are an artifact of the selection effects of the burst sample in which they were f ound; these selection effects may favor sub-populations for which the se relations are valid.

Band, David L.↗

A Small Mission Featuring an Imaging X-ray Polarimeter with High Sensitivity

We present a detailed description of a small mission capable of obtaining high precision and meaningful measurement of the X‐ray polarization of a variety of different classes of cosmic X‐ray sources. Compared to other ideas that have been suggested this experiment has demonstrated in the laboratory a number of extremely important features relevant to the ultimate selection of such a mission by a funding agency. The most important of these questions are: 1) Have you demonstrated the sensitivity to a polarized beam at the energies of interest (i.e. the energies which represent the majority (not the minority) of detected photons from the X‐ray source of interest? 2) Have you demonstrated that the device's sensitivity to an unpolarized beam is really negligible and/or quantified the impact of any systematic effects upon actual measurements? We present our answers to these questions backed up by laboratory measurements and give an overview of the mission.

Weisskopf, Martin C.↗

Nanoparticles for targeted cancer radiotherapy

Radiotherapy, where ionizing radiation is locally delivered either through an external beam or by surgically implanting radionuclide-based seeds in the tumor, is one of the gold standard treatments for cancer. Due to the non-selective nature of radiation, healthy tissue surrounding the cancerous region is usually affected by the treatment. Hence, new strategies, including targeted alpha therapy, are being studied to improve the selectivity of the treatment and minimize side effects. Several challenges, however, limit the current development of targeted radiotherapy, such as the functionalization of the therapeutic agent with targeting vectors and controlling the release of recoiling daughters. Nanoparticles offer unique opportunities as drug delivery vehicles, since they are biocompatible, enhance the cellular uptake of drugs, and are easily functionalized with targeting molecules. In this review, we examine how nanoparticles can be used for targeted radiotherapy, either as sensitizers of external beams or as delivery vehicles for therapeutic radionuclides. Further, we describe the clinical relevance of different types of nanoparticles, followed by an analysis of how these nanoconstructs can solve some of the main limitations of conventional radiotherapy. Finally, we critically discuss the current situation of nanoparticle-based radiotherapy in clinical settings and challenges that need to be overcome in the future for further development of the field.

62 RADIOLOGY AND NUCLEAR MEDICINE↗