Search NASA⌕ Search

SEARCH · Search NASA

Results for “Bench Experiment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Some advances in experimentation supporting development of viscoplastic constitutive models

The development of a biaxial extensometer capable of measuring axial, torsion, and diametral strains to near-microstrain resolution at elevated temperatures is discussed. An instrument with this capability was needed to provide experimental support to the development of viscoplastic constitutive models. The advantages gained when torsional loading is used to investigate inelastic material response at elevated temperatures are highlighted. The development of the biaxial extensometer was conducted in two stages. The first involved a series of bench calibration experiments performed at room temperature. The second stage involved a series of in-place calibration experiments conducted at room and elevated temperature. A review of the calibration data indicated that all performance requirements regarding resolution, range, stability, and crosstalk had been met by the subject instrument over the temperature range of interest, 21 C to 651 C. The scope of the in-place calibration experiments was expanded to investigate the feasibility of generating stress relaxation data under torsional loading.

Ellis, J. R.↗

Some advances in experimentation supporting development of viscoplastic constitutive models

The development of a biaxial extensometer capable of measuring axial, torsion, and diametral strains to near-microstrain resolution at elevated temperatures is discussed. An instrument with this capability was needed to provide experimental support to the development of viscoplastic constitutive models. The advantages gained when torsional loading is used to investigate inelastic material response at elevated temperatures are highlighted. The development of the biaxial extensometer was conducted in two stages. The first involved a series of bench calibration experiments performed at room temperature. The second stage involved a series of in-place calibration experiments performed at room temperature. A review of the calibration data indicated that all performance requirements regarding resolution, range, stability, and crosstalk had been met by the subject instrument over the temperature range of interest, 21 C to 651 C. The scope of the in-placed calibration experiments was expanded to investigate the feasibility of generating stress relaxation data under torsional loading.

Ellis, J. R.↗

Novel extraterrestrial processing for space propulsion

In the present quantitative consideration of space processing concepts for chemicals, theoretical parametric calculations are supplemented by a bench scale experiment. Attention is given to the case of water splitting to generate hydrogen and oxygen for a simple rocket motor that can be used in periodic thrusting. This concept of in situ propellant production is treated in detail and compared with more recent energy and materials technologies.

Ramohalli, K.↗

Characterization of metal oxide absorbents for regenerative carbon dioxide and water vapor removal for advanced portable life support systems

Characterization of the performance of a silver-oxide-based absorbent in terms of its ability to remove both gaseous CO2 and water vapor in an astronaut portable life support systems (PLSS) is discussed. Attention is focused on regeneration of the absorbent from the carbonite state of the oxide state, preconditioning of the absorbent using a humidified gas stream, and absorption breakthrough testing. Based on the results of bench-scale experiments, a test plan is carried out to further characterize the silver-oxide-based absorbent on a larger scale; it calls for examination of the absorbent in both an adiabatic packed bed and a near-isothermal cooled bed configuration. It is demonstrated that the tested absorbent can be utilized in a way that removes substantial amounts of CO2 and water vapor during an 8-hour extravehicular activity mission, and that applying the absorbent to PLSS applications can simplify the ventilation loop.

Kast, Timothy P.↗

NASA. Langley Research Center dry powder towpreg system

Dry powder polymer impregnated carbon fiber tows were produced for preform weaving and composite materials molding applications. In the process, fluidized powder is deposited on spread tow bundles and melted on the fibers by radiant heating to adhere the polymer to the fiber. Unit design theory and operating correlations were developed to provide the basis for scale up of the process to commercial operation. Special features of the operation are the pneumatic tow spreader, fluidized bed, resin feeder, and quality control system. Bench scale experiments, at tow speeds up to 50 cm/sec, demonstrated that process variables can be controlled to produce weavable LARC-TPI carbon fiber towpreg. The towpreg made by the dry powder process was formed into unidirectional fiber moldings and was woven and molded into preform material of good quality.

Baucom, Robert M.↗

Aquatic biofilms and their responses to disinfection and invading species

The control of microbial contamination is a primary concern in the development of a water reclamation system for long-duration manned space flights. This paper describes bench-scale experiments, using both static and recycling water systems, investigating the interaction of bacterial species in the development of a biofilm and their response to the introduction of a disinfectant or of additional species. The results showed that iodine concentrations as high as 15 to 20 mg/l I2 are necessary to completely disinfect a stable biofilm. When S. aueus and E. coli were introduced into a system containing natural mixed culture biofilms, their colonization in the biofilms increased their survival time, from 3 to 5 days as unattached cells to over 60 days when protected in the biofilms. While iodine concentrations of 0.5 to 1 mg/l were enough to eliminate these organisms from the bulk water, concentrations higher than 4.0 mg/l were necessary to completely eliminate these organisms from the biofilm.

Smithers, G. A.↗

Snapshot of Active Flow Control Research at NASA Langley

NASA Langley is aggressively investigating the potential advantages of active flow control as opposed to more traditional aerodynamic techniques. Many of these techniques will be blended with advanced materials and structures to further enhance payoff. Therefore a multi-disciplinary approach to technology development is being attempted that includes researchers from the more historical disciplines of fluid mechanics. acoustics, material science, structural mechanics, and control theory. The overall goals of the topics presented are focused on advancing the state of knowledge and understanding of controllable fundamental mechanisms in fluids rather than on specific engineering problems. An organizational view of current research activities at NASA Langley in active flow control as supported by several programs such as the Morphing Project under Breakthrough Vehicle Technologies Program (BVT). the Ultra-Efficient Engine Technology Program (UEET), and the 21st Century Aircraft Technology Program (TCAT) is presented. On-center research as well as NASA Langley funded contracts and grants are discussed at a relatively high level. The products of this research, as part of the fundamental NASA R and D (research and development) program. will be demonstrated as either bench-top experiments, wind-tunnel investigations, or in flight tests. Later they will be transferred to more applied research programs within NASA, DOD (Department of Defense), and U.S. industry.

Washburn, A. E.↗

Active Flow Control Activities at NASA Langley

NASA Langley continues to aggressively investigate the potential advantages of active flow control over more traditional aerodynamic techniques. This paper provides an update to a previous paper and describes both the progress in the various research areas and the significant changes in the NASA research programs. The goals of the topics presented are focused on advancing the state of knowledge and understanding of controllable fundamental mechanisms in fluids as well as to address engineering challenges. An organizational view of current research activities at NASA Langley in active flow control as supported by several projects is presented. On-center research as well as NASA Langley funded contracts and grants are discussed at a relatively high level. The products of this research are to be demonstrated either in bench-top experiments, wind-tunnel investigations, or in flight as part of the fundamental NASA R&D program and then transferred to more applied research programs within NASA, DOD, and U.S. industry.

Anders, Scott G.↗

Overview of Active Flow Control at NASA Langley Research Center

The paper summarizes Active Flow Control projects currently underway at the NASA Langley Research Center. Technology development is being pursued within a multidisciplinary, cooperative approach, involving the classical disciplines of fluid mechanics, structural mechanics, material science, acoustics, and stability and control theory. Complementing the companion papers in this session, the present paper will focus on projects that have the goal of extending the state-of-the-art in the measurement, prediction, and control of unsteady, nonlinear aerodynamics. Toward this goal, innovative actuators, micro and macro sensors, and control strategies are considered for high payoff flow control applications. The target payoffs are outlined within each section below. Validation of the approaches range from bench-top experiments to wind-tunnel experiments to flight tests. Obtaining correlations for future actuator and sensor designs are implicit in the discussion. The products of the demonstration projects and design tool development from the fundamental NASA R&D level technology will then be transferred to the Applied Research components within NASA, DOD, and US Industry. Keywords: active flow control, separation control, MEMS, review

Pack, L. G.↗

Engagement of Metal Debris into a Gear Mesh

A series of bench top experiments was conducted to determine the effects of metallic debris being dragged through meshing gear teeth. A test rig that is typically used to conduct contact fatigue experiments was used for these tests. Several sizes of drill material, shim stock, and pieces of gear teeth were introduced and then driven through the meshing region. The level of torque required to drive the "chip" through the gear mesh was measured. From the data gathered, chip size sufficient to jam the mechanism can be determined.

Handschuh, Robert F.↗

Carbon Dioxide Control System for a Mars Space Suit Life Support System

Carbon dioxide (CO2) control during Extravehicular Activities (EVAs) on Mars will be challenging. Lithium hydroxide (LiOH) canisters have impractical logistics penalties, and regenerable metal oxide (MetOx) canisters weigh too much. Cycling bed systems and permeable membranes that are regenerable in space vacuum cannot vent on Mars due to the high partial pressure of CO2 in the atmosphere. Although sweep gas regeneration is under investigation, the feasibility, logistics penalties, and failure modes associated with this technique have not been fully determined. TDA Research, Inc. is developing a durable, high-capacity regenerable adsorbent that can remove CO2 from the space suit ventilation loop. The system design allows sorbent regeneration at or above 6 torr, eliminating the potential for Martian atmosphere to leak into the regeneration bed and into the ventilation loop. Regeneration during EVA eliminates the consumable requirement related to the use of LiOH canisters and the mission duration limitations imposed by MetOx system. The concept minimizes the amount of consumable to be brought from Earth and makes the mission more affordable, while providing great operational flexibility during EVA. The feasibility of the concept has been demonstrated in a series of bench-scale experiments and a preliminary system analysis. Results indicate that sorbent regeneration can be accomplished by applying a 14 C temperature swing, while regenerating at 13 torr (well above the Martian atmospheric pressure), withstanding over 1,000 adsorption/regeneration cycles. This paper presents the latest results from these sorbent and system development efforts.

Alptekin, Gokhan↗

Carbon Dioxide Control System for a Mars Space Suit Life Support System

Carbon dioxide (CO2) control during Extravehicular Activities (EVAs) on Mars will be challenging. Lithium hydroxide (LiOH) canisters have impractical logistics penalties, and regenerable metal oxide (MetOx) canisters weigh too much. Cycling bed systems and permeable membranes that are regenerable in space vacuum cannot vent on Mars due to the high partial pressure of CO2 in the atmosphere. Although sweep gas regeneration is under investigation, the feasibility, logistics penalties, and failure modes associated with this technique have not been fully determined. TDA Research, Inc. is developing a durable, high-capacity regenerable adsorbent that can remove CO2 from the space suit ventilation loop. The system design allows sorbent regeneration at or above 6 torr, eliminating the potential for Martian atmosphere to leak into the regeneration bed and into the ventilation loop. Regeneration during EVA minimizes the amount of consumables to be brought from Earth and makes the mission more affordable, while providing great operational flexibility during EVA. The feasibility of the concept has been demonstrated in a series of bench-scale experiments and a preliminary system analysis. This paper presents the latest results from these sorbent and system development efforts.

Alptekin, Gokhan↗

Engagement of Metal Debris into Gear Mesh

A series of bench-top experiments was conducted to determine the effects of metallic debris being dragged through meshing gear teeth. A test rig that is typically used to conduct contact fatigue experiments was used for these tests. Several sizes of drill material, shim stock and pieces of gear teeth were introduced and then driven through the meshing region. The level of torque required to drive the "chip" through the gear mesh was measured. From the data gathered, chip size sufficient to jam the mechanism can be determined.

handschuh, Robert F.↗

Progress of a Cross-Correlation Based Optical Strain Measurement Technique for Detecting Radial Growth on a Rotating Disk

The Aeronautical Sciences Project under NASA's Fundamental Aeronautics Program is interested in the development of novel measurement technologies, such as optical surface measurements for the in situ health monitoring of critical constituents of the internal flow path. In situ health monitoring has the potential to detect flaws, i.e. cracks in key components, such as engine turbine disks, before the flaws lead to catastrophic failure. The present study, aims to further validate and develop an optical strain measurement technique to measure the radial growth and strain field of an already cracked disk, mimicking the geometry of a sub-scale turbine engine disk, under loaded conditions in the NASA Glenn Research Center's High Precision Rotordynamics Laboratory. The technique offers potential fault detection by imaging an applied high-contrast random speckle pattern under unloaded and loaded conditions with a CCD camera. Spinning the cracked disk at high speeds (loaded conditions) induces an external load, resulting in a radial growth of the disk of approximately 50.0-μm in the flawed region and hence, a localized strain field. When imaging the cracked disk under static conditions, the disk will be undistorted; however, during rotation the cracked region will grow radially, thus causing the applied particle pattern to be 'shifted'. The resulting particle displacements between the two images is measured using the two-dimensional cross-correlation algorithms implemented in standard Particle Image Velocimetry (PIV) software to track the disk growth, which facilitates calculation of the localized strain field. A random particle distribution is adhered onto the surface of the cracked disk and two bench top experiments are carried out to evaluate the technique's ability to measure the induced particle displacements. The disk is shifted manually using a translation stage equipped with a fine micrometer and a hotplate is used to induce thermal growth of the disk, causing the particles to become shifted. For both experiments, reference and test images are acquired before and after the induced shifts, respectively, and then processed using PIV software. The controlled manual translation of the disk resulted in detection of the particle displacements accurate to ~1.75% of full scale and the thermal expansion experiment resulted in successful detection of the disk's thermal growth as compared to the calculated thermal expansion results. After validation of the technique through the induced shift experiments, the technique is implemented in the Rotordynamics Lab for preliminary assessment in a simulated engine environment. The discussion of the findings and plans for future work to improve upon the results are addressed in the paper.

rotordynamics↗

Optical Measurement System for Strain Field Ahead of a Crack Tip for Lattice Structures

The aim of the ARAMADAS project is to automate the construction of cuboctahedral lattice structures. Lattice materials are appealing for aerospace applications due to their strength and stiffness at ultra-light densities. However, in order for any material to be realistically considered for such environments, it must also be damage tolerant. The ability of a material to absorb damage is characterized by its fracture toughness, which remains poorly characterized for lattice materials. Consequently, the objective of this research is to develop an optical measurement system to experimentally validate the strain field ahead of a crack tip in architecture lattice materials. Although the ability to predict the strain field ahead of a crack tip has been investigated for continuum materials, such behaviour of three-dimensional architectures is under-investigated. As such, we will use a custom optical measurement system to track deformation of the voxels in a side-cracked plate fracture specimen. The system shall use 3D pose estimation, stereo imaging, and possibly color tracking, in combination with optical flow algorithms, to compute information regarding the three-dimensional movement movement of the lattice nodes during mechanical testing. Bench top experiments will validate the optical measurement system and characterize precision. Additionally, the effect of multiple cameras on precision, as well as system scalability will be investigated. Final results will compare measured lattice deformation with finite element predictions.

Lennig, Miriam↗

RF-THERMAL COMBINED SIMULATIONS OF A SUPERCONDUCTING HOM COAXIAL COUPLER

To benchmark a multi-physics code VORPAL developed by Tech-X, the High Order Mode (HOM) coaxial coupler design implemented in Jefferson Lab?s 12GeV upgrade cryomodules is analyzed by use of commercial codes, such as ANSYS, HFSS and Microwave Studio. Testing data from a Horizontal Test Bench (HTB) experiment on a dual-cavity prototype are also utilized in the verification of simulation results. The work includes two stages: first, the HOM feedthrough that has a high RRR niobium probe and sapphire insulator is analyzed for the RF-thermal response when there is travelling wave passing through; second, the HTB testing condition is simulated and results from simulation are compared to thermal measurements from HTB tests. The analyses are of coupled-field nature and involve highly nonlinear temperature dependent thermal conductivities and electric resistivities for the eight types of materials used in the design. Accuracy and efficiency are the main factors in evaluation of the performance of the codes.

43 PARTICLE ACCELERATORS↗

Effect of Surface Flow on Topography in Niobium Electropolishing

Electropolishing (EP) is reliably delivering improved performance of multi-celled niobium SRF accelerator cavities, attributed to the smoother surface obtained. This superior leveling is a consequence of an etchant concentration gradient layer that arises in the HF-H2SO4 electrolyte adjacent to the niobium surface during polishing. Electrolyte circulation raises the prospect that fluid flow adjacent to the surface might affect the diffusion layer and impair EP performance. In this study, preliminary bench-top experiments with a moving electrode apparatus were conducted. We find that flow conditions approximating cavity EP show no effects attributable to depletion layer disruption.

43 PARTICLE ACCELERATORS↗

An Injectable Apatite Permeable Reactive Barrier for In Situ 90Sr Immobilization

An injectable permeable reactive barrier (PRB) technology was developed to sequester 90Sr in groundwater through the in situ formation of calcium-phosphate mineral phases, specifically apatite that incorporates 90Sr into the chemical structure. An integrated, multi-scale development and testing approach was used that included laboratory bench-scale experiments, an initial pilot-scale field test, and the emplacement and evaluation of a 300-ft-long treatability-test-scale PRB. Standard groundwater wells were used for emplacement of the treatment zone, allowing treatment of contaminants too deep below ground surface for trench-and-fill type PRB technologies. The apatite amendment formulation uses two separate precursor solutions, one containing a Ca-citrate complex and the other a Na-phosphate solution, to form apatite precipitate in situ. Citrate is needed to keep calcium in solution long enough to achieve a more uniform and areally extensive distribution of precipitate formation. In the summer of 2008, the apatite PRB technology was applied as a 91-m (300-ft) -long permeable reactive barrier on the downgradient edge of a 90Sr plume beneath the Hanford Site in Washington State. The technology was deployed to reduce 90Sr flux discharging to the Columbia River. Performance assessment monitoring data collected to date indicate the barrier is meeting performance objectives. The average reduction in 90Sr concentrations at four downgradient compliance monitoring locations was 95% relative to the high end of the baseline range approximately 1 year after treatment, and continues to meet remedial objectives more than 4 years after treatment.

in situ 90Sr immobilization↗