Search NASA⌕ Search

SEARCH · Search NASA

Results for “Biomedical diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

SU-F-T-617: Remotely Pre-Planned Stereotactic Ablative Radiation Therapy: Validation of Treatment Plan Quality

Purpose: We propose a workflow to improve access to stereotactic ablative radiation therapy (SABR) for rural patients. When implemented, a separate trip to the central facility for simulation can be eliminated. Two elements are required: (1) Fabrication of custom immobilization devices to match positioning on prior diagnostic CT (dxCT). (2) Remote radiation pre-planning on dxCT, with transfer of contours/plan to simulation CT (simCT) and initiation of treatment same-day or next day. In this retrospective study, we validated part 2 of the workflow using patients already treated with SABR for upper lobe lung tumors. Methods: Target/normal structures were contoured on dxCT; a plan was created and approved by the physician. Structures were transferred to simCT using deformable image registration and the plan was re-optimized on simCT. Plan quality was evaluated through comparison to gold-standard structures contoured on simCT and a gold-standard plan based on these structures. Workflow-generated plan quality in this study represents a worst-case scenario as these patients were not treated using custom immobilization to match dxCT position as would be done when the workflow is implemented clinically. Results: 5/6 plans created through the pre-planning workflow were clinically acceptable. For all six plans, the gold-standard GTV received full prescription dose, along with median PTV V95%=95.2% and median PTV D95%=95.4%. Median GTV DSC=0.80, indicating high degree of similarity between the deformed and gold-standard GTV contours despite small GTV sizes (mean=3.0cc). One outlier (DSC=0.49) resulted in inadequate PTV coverage (V95%=62.9%) in the workflow plan; in clinical practice, this mismatch between deformed/gold-standard GTV would be revised by the physician after deformable registration. For all patients, normal tissue doses were comparable to the gold-standard plan and well within constraints. Conclusion: Pre-planning SABR cases on diagnostic imaging generated clinically acceptable plans. Coupled with rapid-prototyped custom immobilization, this workflow may improve treatment access for rural patients.

60 APPLIED LIFE SCIENCES↗

The Human Phenotype Ontology in 2017

Deep phenotyping has been defined as the precise and comprehensive analysis of phenotypic abnormalities in which the individual components of the phenotype are observed and described. The three components of the Human PhenotypeOntology (HPO; www.human-phenotype-ontology.org) project are the phenotype vocabulary, disease-phenotype annotations and the algorithms that operate on these. These components are being used for computational deep phenotyping and precision medicine as well as integration of clinical data into translational research. The HPO is being increasingly adopted as a standard for phenotypic abnormalities by diverse groups such as international rare disease organizations, registries, clinical labs, biomedical resources, and clinical software tools and will thereby contribute toward nascent efforts at global data exchange for identifying disease etiologies. This update article reviews the progress of the HPO project since the debut Nucleic Acids Research database article in 2014, including specific areas of expansion such as common (complex) disease, new algorithms for phenotype driven genomic discovery and diagnostics, integration of cross-species mapping efforts with the Mammalian Phenotype Ontology, an improved quality control pipeline, and the addition of patient-friendly terminology.

59 BASIC BIOLOGICAL SCIENCES↗

Gas Chromatic Mass Spectrometer

Gas chromatograph/mass spectrometer (GC/MS) used to measure and identify combustion species present in trace concentration. Advanced extractive diagnostic method measures to parts per billion (PPB), as well as differentiates between different types of hydrocarbons. Applicable for petrochemical, waste incinerator, diesel transporation, and electric utility companies in accurately monitoring types of hydrocarbon emissions generated by fuel combustion, in order to meet stricter environmental requirements. Other potential applications include manufacturing processes requiring precise detection of toxic gaseous chemicals, biomedical applications requiring precise identification of accumulative gaseous species, and gas utility operations requiring high-sensitivity leak detection.

Wey, Chowen↗

WE-AB-206-03: Workshop

The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. The goal of this ultrasound hands-on workshop is to demonstrate quality control (QC) testing in diagnostic ultrasound and to provide updates in ACR ultrasound accreditation requirements. The first half of this workshop will include two presentations reviewing diagnostic ultrasound QA/QC and ACR ultrasound accreditation requirements. The second half of the workshop will include live demonstrations of basic QC tests. An array of ultrasound testing phantoms and ultrasound scanners will be available for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations and on-site instructors. The targeted attendees are medical physicists in diagnostic imaging. Learning Objectives: Gain familiarity with common elements of a QA/QC program for diagnostic ultrasound imaging dentify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools Learn ACR ultrasound accreditation requirements Jennifer Walter is an employee of American College of Radiology on Ultrasound Accreditation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Biological toxicity and environmental hazards associated with PLGA nanoparticles

There have been tremendous advances in nanotechnology. More recently, the use of nanoparticles has expanded to applications including materials, packaging, energy, and medical uses such as drug delivery, diagnostics, and therapeutics. The American Society for Testing and Materials (ASTM) and the International Organization for Standardization (ISO) define nanoparticles as particles with at least one dimension measuring between 1 and 100 nm (2), but this view is generally too limited, and recommendations have been made to consider all materials with a dimension measuring under 1,000 nm as nanoparticles. The biomedical uses of nanoparticles are particularly promising because of their ability to reach and target various sites and organs. However, some nanoparticles can be composed of toxic materials or are limited by issues of biodistribution and bioaccumulation, which have hampered their use in biomedicine. The copolymer poly lactic-co-glycolic acid (PLGA) has gained use in biomedical applications as a delivery system because it is considered biocompatible and can be formulated with controlled degradation in physiological environments. PLGA has a history in biomedicine that dates to the 1970s when biodegradable sutures were developed using PLGA. In addition, the United States (US) Food and Drug Administration (FDA) and the European Medicine Agency (EMA) have approved various PLGA particle formulations as therapeutic delivery vehicles. Interest in biocompatible materials to deliver a range of therapeutic drugs, proteins, nucleic acids, and other molecules has risen recently. In addition to drug delivery, sustained drug release can be achieved by tuning the physical properties of PLGA, such as the molecular weight, ratio of lactic to glycolic acid, drug concentration, stabilizing molecules, and particle size. Given the rise of nanoparticles, human and environmental exposure to them is inevitable as more applications use free, unbound, and highly mobile particles. Although PLGA is generally considered safe, a detailed understanding of how PLGA and the other components used to help formulate this copolymer into a nanoparticle delivery vehicle is useful for assessing potential harmful effects. Despite recent advances in PLGA nanoparticle formulations, residual stabilizing molecules, inconsistent preparations, and batch-to-batch variations can lead to toxicity. Poor preparations of PLGA can lead to common mechanisms of toxicity observed with nanoparticles, such as inflammation and oxidative stress. Consistency in PLGA formulations and accurate methods to evaluate nanoparticle toxicity are needed to ensure safety. In order to better assess PLGA nanoparticles as non-toxic delivery systems, it is critical to understand their physical and chemical properties and the formulation protocols that may introduce toxic components into particles.

Biology, nanoparticle, toxicity↗

Bimodal imaging of functional changes in blood flow using optoacoustic and optical coherent angiography

The results of a complementary study of functional changes of the blood flow in human superficial tissues using optoacoustic (OA) microscopy and angiographic optical coherent tomography (OCT-A) during an occlusive test are demonstrated for the first time. OA microscopy data allow one to estimate the increase in blood content during the occlusive test, while OCT-A data demonstrate a decrease in the number of vessels with a functioning blood flow in the area of interest. The combined approach reported in the paper can be employed in experimental and clinical medicine to study the functional changes of microcirculation in diagnostics of vascular pathologies of superficial tissues and to evaluate the microcirculation response to treatment. (paper)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interventional Management of Subcapsular Hepatic Hematoma with Hepatic Compartment Syndrome After Laparoscopic Adrenalectomy

Hepatic compartment syndrome is an increase in intrahepatic pressure sufficient to cause compromised hepatic perfusion. Early recognition and prompt management are essential for preventing catastrophic consequences including ischemic liver failure and hypovolemic shock. This is the rare case of laparoscopic adrenalectomy resulting in subcapsular hepatic hematoma with hepatic compartment syndrome. Contrast-enhanced computed tomography demonstrated extensive subcapsular hepatic hematoma with collapse of portal vein and inferior vena cava suggesting impending compartment syndrome. Diagnostical catheter angiography of the liver revealed innumerable foci of petechial extravasation from disrupted isolated arteries. Emergent percutaneous catheter decompression and transarterial embolization were successful.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

P-Mart: Interactive Analysis of Ion Abundance Global Proteomics Data

The use of mass-spectrometry-based techniques for global protein profiling of biomedical or environmental experiments has become a major focus in research centered on biomarker discovery; however, one of the most important issues recently highlighted in the new era of omics data generation is the ability to perform analyses in a robust and reproducible manner. This has been hypothesized to be one of the issues hindering the ability of clinical proteomics to successfully identify clinical diagnostic and prognostic biomarkers of disease. P-Mart (https://pmart.labworks.org) is an interactive web-based software environment that enables domain scientists to perform quality-control processing, statistics, and exploration of large-complex proteomics data sets without requiring statistical programming. P-Mart is developed in a manner that allows researchers to perform analyses via a series of modules, explore the results using interactive visualization, and finalize the analyses with a collection of output files documenting all stages of the analysis and a report to allow reproduction of the analysis.

59 BASIC BIOLOGICAL SCIENCES↗

Corrected coronary opacification decrease from coronary computed tomography angiography: Validation with quantitative 13N-ammonia positron emission tomography

Background: To assess the functional relevance of a coronary artery stenosis, corrected coronary opacification (CCO) decrease derived from coronary computed tomography angiography (CCTA) has been proposed. The present study aims at validating CCO decrease with quantitative 13N-ammonia positron emission tomography (PET) myocardial perfusion imaging (MPI). Methods and Results: This retrospective study consists of 39 patients who underwent hybrid CCTA/PET-MPI. From CCTA, attenuation in the coronary lumen was measured before and after a stenosis and corrected to the aorta to calculate CCO and its decrease. Relative flow reserve (RFR) was calculated by dividing the stress myocardial blood flow (MBF) of a vessel territory subtended by a stenotic coronary by the stress MBF of the reference territories without stenoses. RFR was abnormal in 11 vessel territories (27%). CCO decrease yielded a sensitivity, specificity, negative predictive value, positive predictive value, and accuracy for prediction of an abnormal RFR of 73%, 70%, 88%, 47%, and 70%, respectively. Conclusions: CCTA-derived CCO decrease has moderate diagnostic accuracy to predict an abnormal RFR in PET-MPI. However, its high negative predictive value to rule out functional relevance of a given lesion may confer clinical implications in the diagnostic work-up of patients with a coronary stenosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-J-163: In Vivo Quantification of Sequence Parameter Effect On Geometric Distortion Caused by Implanted Titanium Brachytherapy Applicator

Purpose: The use of MR to plan and evaluate brachytherapy treatment for cervical cancer is increasing given the availability of MR conditional or safe applicators and MRI’s proven superiority to CT for characterizing soft tissue lesions. The titanium applicators, however, cause geometric distortions or imaging artifacts, which reduce the utility of MRI for dosimetry. We sought to quantify the observed volume of the same applicator on a previously optimized T2 sequence in comparison to the conventional T2 sequence and CT obtained for brachytherapy planning. Methods: Prior work with testing in phantoms showed that increases in readout bandwidth yielded reductions in artifact area and distortion measurements even with voxel increases. Following IRB approval, nine patients with titanium tandem & ovoid applicator (Varian Medical Systems) in place were scanned with a standard periprocedural protocol which included sagittal T2 fast spin echo (FSE) acquisition (res 0.98×0.78×4.0 mm{sup 3}; BW 200Hz). An additional T2-weighted FSE sequence (res 0.98×0.98×3–4 mm{sup 3}; BW500Hz) with increased readout bandwidth, readout voxel size, and echo train length was added to the protocol. Volume measurements of the applicator (from tip to cervical stop) were hand-segmented in Velocity AI 3.1 (Velocity Medical Solutions) for the two T2 FSE sequences and a planning CT obtained shortly after MRI. Differences were analyzed using a paired t-test. Results: Average apparent volumes of the applicator on standard T2 sequence, decreased bandwidth T2 sequence and CT were 5.922±1.283 cm{sup 3}, 4.544±1.524 cm3, and 2.304±0.509 cm{sup 3} respectively. Conclusion: Apparent volumes of a brachytherapy applicator can be compared in vivo. The modified sequence results in decreased apparent size of the cervical applicator. Both MR sequence volumes were larger than the planning CT, which was expected. Future work will focus on the diagnostic quality of the new sequence and quantifying any geometric shifts after CT to MRI registration based on anatomical landmarks.

60 APPLIED LIFE SCIENCES↗

ACC/AATS/AHA/ASE/ASNC/HRS/SCAI/SCCT/SCMR/STS 2019 Appropriate Use Criteria for Multimodality Imaging in the Assessment of Cardiac Structure and Function in Nonvalvular Heart Disease

This document is the second of 2 companion appropriate use criteria (AUC) documents developed by the American College of Cardiology, American Association for Thoracic Surgery, American Heart Association, American Society of Echocardiography, American Society of Nuclear Cardiology, Heart Rhythm Society, Society for Cardiovascular Angiography and Interventions, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, and Society of Thoracic Surgeons. The first document (J Am Coll Cardiol 2017;70:1647-1672) addresses the evaluation and use of multimodality imaging in the diagnosis and management of valvular heart disease, whereas this document addresses this topic with regard to structural (nonvalvular) heart disease. While dealing with different subjects, the 2 documents do share a common structure and feature some clinical overlap. The goal of the companion AUC documents is to provide a comprehensive resource for multimodality imaging in the context of structural and valvular heart disease, encompassing multiple imaging modalities. Using standardized methodology, the clinical scenarios (indications) were developed by a diverse writing group to represent patient presentations encountered in everyday practice and included common applications and anticipated uses. Where appropriate, the scenarios were developed on the basis of the most current American College of Cardiology/American Heart Association Clinical Practice Guidelines. A separate, independent rating panel scored the 102 clinical scenarios in this document on a scale of 1 to 9. Scores of 7 to 9 indicate that a modality is considered appropriate for the clinical scenario presented. Midrange scores of 4 to 6 indicate that a modality may be appropriate for the clinical scenario, and scores of 1 to 3 indicate that a modality is considered rarely appropriate for the clinical scenario. The primary objective of the AUC is to provide a framework for the assessment of these scenarios by practices that will improve and standardize physician decision making. AUC publications reflect an ongoing effort by the American College of Cardiology to critically and systematically create, review, and categorize clinical situations in which diagnostic tests and procedures are utilized by physicians caring for patients with cardiovascular diseases. The process is based on the current understanding of the technical capabilities of the imaging modalities examined.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous ureteral biopsy: safety and diagnostic yield

Purpose: To evaluate safety and diagnostic yield of percutaneous CT-guided biopsy of extrarenal upper urinary tract lesions. Materials and methods: Retrospective review of our institutional database of image-guided biopsies yielded 44 CT-guided percutaneous biopsies in 44 unique patients that targeted ureteral (30, 68%) or other non-renal upper urinary tract lesions (14, 32%) between January 1, 2000 and May 1, 2017. Indications, pre-biopsy imaging, biopsy technique, peri-procedural antithrombotic use, complications including bleeding defined by Society of Interventional Radiology criteria, pathology results, and subsequent imaging were reviewed up to 3 months after the procedure to evaluate safety and diagnostic yield. Results: Mean patient age was 66 (range 27–88) and 23/44 patients were male. The majority (34/44) of lesions were sampled with an 18-gauge biopsy device via a 17-gauge introducer needle, and the remaining 10/44 lesions were sampled with a 19/20 gauge system. The mean number of core samples obtained was 4 (range 2–10). No major complications occurred. Specifically, no patient developed a urine leak or urinary obstruction. Minor complications occurred in 3/44 (7%) biopsies, all retroperitoneal hemorrhages that did not require transfusion or other intervention. Biopsy was adequate for pathologic examination in 41 of 44 (93%) cases. Among patients undergoing surgical resection, biopsy diagnosis was concordant with surgical pathology in 9/10 (90%) cases and discordant in 1/10 (10%). Conclusion: CT-guided percutaneous biopsy of upper urinary tract lesions can be performed safely, with high diagnostic yield, and with a high rate of concordance on subsequent surgical pathology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-DE-BRA-05: EUTEMPE-RX: Combining E-Learning and Face-To-Face Training to Build Expert Knowledge, Skills and Competences for Medical Physicists in Diagnostic and Interventional Radiology

Purpose: In 2013, the EURATOM authorities of the European Commission decided to support the Horizon2020 project submission ‘EUTEMPE-RX’ that aimed for a new set of course modules to train medical physicists in diagnostic and interventional radiology to expert level with small group deep learning. Each module would consist of 2 phases: an e-learning and a face-to-face phase, each phase requiring typically 40h of participant time. Methods: The European Federation (EFOMP) and 13 European partners, all of them selected for their excellent scientific and/or educational skills, led the 12 course modules. A quality manual ensured the quality of course content and organization. Educational workshops familiarized the teachers with e-learning techniques and methods for assessment. Content was set in accordance with the EC document RP174 that lists learning outcomes in terms of knowledge, skills and competences (KSCs) for different specialties and levels of medical physics. Surveys for stake holder satisfaction were prepared. Results: Today the course modules are being realized. The modules cover most of the KSCs in RP174 document. Teachers have challenged the participants with unique tasks: case studies in medical physics leadership, Monte Carlo simulation of a complete x-ray imaging chain, development of a task specific QA protocol, compilation of optimization plans, simulation tasks with anthropomorphic breast models, etc. Participants undertook practical sessions in modern hospitals and visited a synchrotron facility, a calibration lab, screening organizations, etc. Feedback form quality surveys was very positive and constructive. A sustainability plan has been worked out. Conclusion: The modules have enabled the participants to develop their KSCs and cope with challenges in medical physics. The sustainability plan will be implemented to continue the unique combined e-learning and face to face training at high level training in diagnostic and interventional radiology also beyond Europe. The EUTEMPE-RX project is funded by the Horizon2020 - EURATOM program of the European Commission.

60 APPLIED LIFE SCIENCES↗

Technical Note: Confirming the prescribed angle of CT localizer radiographs and c-arm projection acquisitions

Purpose: Accurate CT radiograph angle is not usually important in diagnostic CT. However, there are applications in radiation oncology and interventional radiology in which the orientation of the x-ray source and detector with respect to the patient is clinically important. The authors present a method for measuring the accuracy of the tube/detector assembly with respect to the prescribed tube/detector position for CT localizer, fluoroscopic, and general radiograph imaging using diagnostic, mobile, and c-arm based CT systems. Methods: A mathematical expression relating the x-ray projection of two metal BBs is related to gantry angle. Measurement of the BBs at a prescribed gantry (i.e., c-arm) angle can be obtained and using this relation the prescribed versus actual gantry angle compared. No special service mode or proprietary information is required, only access to projection images is required. Projection images are available in CT via CT localizer radiographs and in the interventional setting via fluorography. Results: The technique was demonstrated on two systems, a mobile CT scanner and a diagnostic CT scanner. The results confirmed a known issue with the mobile scanner and accurately described the CT localizer angle of the diagnostic system tested. Conclusions: This method can be used to quantify gantry angle, which is important when projection images are used for procedure guidance, such as in brachytherapy and interventional radiology applications.

61 RADIATION PROTECTION AND DOSIMETRY↗

Automatic anatomy recognition in whole-body PET/CT images

Purpose: Whole-body positron emission tomography/computed tomography (PET/CT) has become a standard method of imaging patients with various disease conditions, especially cancer. Body-wide accurate quantification of disease burden in PET/CT images is important for characterizing lesions, staging disease, prognosticating patient outcome, planning treatment, and evaluating disease response to therapeutic interventions. However, body-wide anatomy recognition in PET/CT is a critical first step for accurately and automatically quantifying disease body-wide, body-region-wise, and organwise. This latter process, however, has remained a challenge due to the lower quality of the anatomic information portrayed in the CT component of this imaging modality and the paucity of anatomic details in the PET component. In this paper, the authors demonstrate the adaptation of a recently developed automatic anatomy recognition (AAR) methodology [Udupa et al., “Body-wide hierarchical fuzzy modeling, recognition, and delineation of anatomy in medical images,” Med. Image Anal. 18, 752–771 (2014)] to PET/CT images. Their goal was to test what level of object localization accuracy can be achieved on PET/CT compared to that achieved on diagnostic CT images. Methods: The authors advance the AAR approach in this work in three fronts: (i) from body-region-wise treatment in the work of Udupa et al. to whole body; (ii) from the use of image intensity in optimal object recognition in the work of Udupa et al. to intensity plus object-specific texture properties, and (iii) from the intramodality model-building-recognition strategy to the intermodality approach. The whole-body approach allows consideration of relationships among objects in different body regions, which was previously not possible. Consideration of object texture allows generalizing the previous optimal threshold-based fuzzy model recognition method from intensity images to any derived fuzzy membership image, and in the process, to bring performance to the level achieved on diagnostic CT and MR images in body-region-wise approaches. The intermodality approach fosters the use of already existing fuzzy models, previously created from diagnostic CT images, on PET/CT and other derived images, thus truly separating the modality-independent object assembly anatomy from modality-specific tissue property portrayal in the image. Results: Key ways of combining the above three basic ideas lead them to 15 different strategies for recognizing objects in PET/CT images. Utilizing 50 diagnostic CT image data sets from the thoracic and abdominal body regions and 16 whole-body PET/CT image data sets, the authors compare the recognition performance among these 15 strategies on 18 objects from the thorax, abdomen, and pelvis in object localization error and size estimation error. Particularly on texture membership images, object localization is within three voxels on whole-body low-dose CT images and 2 voxels on body-region-wise low-dose images of known true locations. Surprisingly, even on direct body-region-wise PET images, localization error within 3 voxels seems possible. Conclusions: The previous body-region-wise approach can be extended to whole-body torso with similar object localization performance. Combined use of image texture and intensity property yields the best object localization accuracy. In both body-region-wise and whole-body approaches, recognition performance on low-dose CT images reaches levels previously achieved on diagnostic CT images. The best object recognition strategy varies among objects; the proposed framework however allows employing a strategy that is optimal for each object.

61 RADIATION PROTECTION AND DOSIMETRY↗

TH-AB-209-09: Quantitative Imaging of Electrical Conductivity by VHF-Induced Thermoacoustics

Purpose: To demonstrate that very high frequency (VHF) induced thermoacoustics has the potential to provide quantitative images of electrical conductivity in Siemens/meter, much as shear wave elastography provides tissue stiffness in kPa. Quantitatively imaging a large organ requires exciting thermoacoustic pulses throughout the volume and broadband detection of those pulses because tomographic image reconstruction preserves frequency content. Applying the half-wavelength limit to a 200-micron inclusion inside a 7.5 cm diameter organ requires measurement sensitivity to frequencies ranging from 4 MHz down to 10 kHz, respectively. VHF irradiation provides superior depth penetration over near infrared used in photoacoustics. Additionally, VHF signal production is proportional to electrical conductivity, and prostate cancer is known to suppress electrical conductivity of prostatic fluid. Methods: A dual-transducer system utilizing a P4-1 array connected to a Verasonics V1 system augmented by a lower frequency focused single element transducer was developed. Simultaneous acquisition of VHF-induced thermoacoustic pulses by both transducers enabled comparison of transducer performance. Data from the clinical array generated a stack of 96-images with separation of 0.3 mm, whereas the single element transducer imaged only in a single plane. In-plane resolution and quantitative accuracy were measured at isocenter. Results: The array provided volumetric imaging capability with superior resolution whereas the single element transducer provided superior quantitative accuracy. Combining axial images from both transducers preserved resolution of the P4-1 array and improved image contrast. Neither transducer was sensitive to frequencies below 50 kHz, resulting in a DC offset and low-frequency shading over fields of view exceeding 15 mm. Fresh human prostates were imaged ex vivo and volumetric reconstructions reveal structures rarely seen in diagnostic images. Conclusion: Quantitative whole-organ thermoacoustic tomography will be feasible by sparsely interspersing transducer elements sensitive to the low end of the ultrasonic range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compartment syndromes

The compartment syndrome is defined as a condition in which high pressure within a closed fascial space (muscle compartment) reduces capillary blood perfusion below the level necessary for tissue viability'. This condition occurs in acute and chronic (exertional) forms, and may be secondary to a variety of causes. The end-result of an extended period of elevated intramuscular pressure may be the development of irreversible tissue injury and Volkmann's contracture. The goal of treatment of the compartment syndrome is the reduction of intracompartmental pressure thus facilitating reperfusion of ischaemic tissue and this goal may be achieved by decompressive fasciotomy. Controversy exists regarding the critical pressure-time thresholds for surgical decompression and the optimal diagnostic methods of measuring intracompartmental pressures. This paper will update and review some current knowledge regarding the pathophysiology, aetiology, diagnosis, and treatment of the acute compartment syndrome.

NASA Discipline Cardiopulmonary↗

Diagnostic imaging of hepatocellular carcinoma at community hospitals and their tertiary referral center in the era of LI-RADS: a quality assessment study

Purpose: To assess guideline compliance and quality of hepatocellular carcinoma, (HCC) diagnostic imaging within community hospitals (CH) and their Tertiary referral center (TRC) in a moderately high incidence region. Methods: Initial diagnostic workup CT/MRI scans of 251 patients (122 CH, 112 TRC, 17 Non-TRC academic) with HCC over a 15-month period were assessed for Liver reporting and Data System (LI-RADS) guideline compliance. 269 scans (182 CT, 87 MRI) were qualitatively evaluated by 2 independent blinded radiologists for arterial timing, overall image quality, noise and sharpness, with quantification of interobserver variability. The contrast enhancement ratio (CER) for the largest HCC on each scan was calculated using pre- and post-contrast images. Results: 103/104 (99%) of TRC and 44/78 (56%) of CH CTs adhered to LI–RADS imaging guidelines (P < 0.0001). Lack of delayed phase accounted for 32/34 (94%) of noncompliant CH CTs. Regarding MRI, 19/19 (100%) of TRC and 60/68 (88%) of CH scans were adherent (P = 0.12). For both modalities, overall image quality, noise and sharpness were rated significantly higher for TRC than CH. There was moderate interobserver agreement with intraclass correlation coefficient of 0.73, 0.70 and 0.63, respectively. Arterial-phase timing was rated adequate for CT in 75/104 TRC (72%) and 10/68 (14%) CH scans (P < 0.0001) and for MRI in 8/19 (42%) TRC and 23/68 (33%) CH scans (P = 0.17). The CER was significantly higher for TRC versus CH (2.9 vs. 1.9, P < 0.001) and MRI (0.9 vs. 0.7, P = 0.03). Conclusions: Community hospital HCC diagnostic scans significantly lag in critical quality parameters of tumor enhancement, arterial phase timing, perceived image quality, and LI-RADS CT technique compliance compared to a TRC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗