Assessing Cost-Optimal Battery Energy and Solar-Plus-Storage Systems for Federal Customers: A Nationwide Assessment: Preprint

Prior research has identified that the financial viability of behind-the-meter battery energy storage systems is heavily dependent on technology cost, utility rate structure, energy consumption patterns, and co-deployment with synergistic technologies like solar photovoltaics (PV), among other factors. This study builds on existing research by comprehensively evaluating the economics of battery energy storage systems (BESS) and solar-plus-storage systems for a reference office building at 755 reference sites under 834 utility rates, and four storage capital cost scenarios. Results indicate that even with dramatic cost reductions, BESS is likely to be cost-effective only under utility rates that include demand charges, and possibly include time-of-use (TOU) pricing as well. Even under these utility rates, BESS systems provide marginal savings, and office building operators are unlikely to deploy the technology for cost savings alone. Solar-plus-storage systems provide more savings than BESS and allow for larger economic storage capacities. Solar-plus-storage provides compelling savings opportunities at baseline prices, and even at capital costs 25% higher than baseline. Solar-plus-storage is most effective where there are demand charges and energy pricing schemes include TOU pricing, or where electricity is expensive (at least $0.30/kWh). Our case studies illustrate that the presence of demand charges, even at similar energy costs, can be the deciding factor in BESS and solar-plus-storage viability. The findings and maps from this assessment may be of use to planners, building owners, and developers looking for potentially economic storage opportunities.

battery energy storage systems↗

Analysis of Ground Source Heat Pump ECMs: Implemented Under DOE ESPC IDIQ Contract

Several federal performance and decarbonization objectives are driving the U.S. government to transition to net-zero emissions across the federal building portfolio. The overarching purpose of this Federal Energy Management Program (FEMP)-Geothermal Technologies Office (GTO) work is to support federal facilities in accomplishing the administration’s federal building decarbonization goals. Creating awareness of existing geothermal (or ground-source) heat pump (GHP) systems deployed on federal property, implemented using performance contracts and evaluating the energy and environmental impacts of these systems, this work will assist federal facilities in considering inclusion of GHP technology energy conservation measures (ECMs) in future performance contracting project awards. This report summarizes analyses of data from GHP ECMs installed under the DOE ESPC IDIQ contract across various climate areas and geographic locations, agencies, and building use types. Through the analysis of proposed GHP ECMs and understanding key metrics on implemented GHP systems in a variety of applications, FEMP and GTO can further support federal agencies in meeting decarbonization and net-zero building goals by evaluating and incorporating GHP systems into performance contracts and communicate the benefits of this technology.

15 GEOTHERMAL ENERGY↗

Quantification of Load Flexibility in Residential Buildings Using Home Energy Management Systems

With increasing penetration of renewable energy resources, the flexibility of operating behind-the-meter (BTM) resources plays a key role in enhancing grid reliability and resilience. Residential buildings with home energy management systems (HEMS) can provide desired flexibility for the distribution system operator (DSO) while considering customer comfort and preferences. This paper discusses a methodology to quantify the flexibility of BTM resources of residential buildings using HEMS. First, we propose a model predictive control framework to formulate the flexibility band comprising nominal, upper, and lower demand profiles. Second, the paper proposes a dispatch method for HEMS to compute the control signals for each BTM resource (e.g., air conditioner, water heater, home battery system) upon receiving a flexibility service request from the DSO. The case study provides insight into the flexibility provided at the whole-home level with different user preferences and seasons. The results demonstrate that HEMS is capable of providing flexibility service at the request of the DSO while delivering primary services to the building occupants.

41 EE - Solar Energy Technologies Office (EE-4S)↗

The Cost of Comfort in Your Home: Peak-Time Energy and Cost Savings from Setpoint Adjustment of Space Heating and Cooling

This poster presents the tradeoff between energy costs and thermal comfort in homes. Residential heating and cooling systems use a thermostat control to maintain a comfortable temperature range, but tighter temperature control leads to higher annual energy costs. We estimate the impact of temperature setpoint adjustment on annual energy costs using a residential building model developed at NREL. We show that increasing the allowable temperature range reduces energy costs in all five of the climate zones in the U.S. Annual costs reduced by about $100, with larger savings in areas with more heating and/or cooling loads.

30 DIRECT ENERGY CONVERSION↗

Indoor Occupant Counting by RF Backscattering

Building HVAC (heating, ventilation and air conditioning) consumes approximately 13% of all energy consumption in USA. Motion detectors, cameras and user programmable thermostats have been shown to be ineffective for HVAC controls to save energy, mostly due to the user concerns of comfort, reliability and privacy. A new HVAC control system based on real-time occupant counting that is fully automated, highly accurate, economically sensible and preserving privacy and aesthetics can thus bring forth a disruptive impact to this large energy sector. Our indoor occupant monitoring technology is based on the radio-frequency identification system (RFID), deployed in the room, not on the occupants. One reader with four antennas can be deployed on the ceiling or behind the ceiling panels for every thousand square feet in home, office and assisted living, with or without room partitions. The sticker-like passive tag, 10 cents each and maintenance-free, are profusely hidden on the wall or inside the furniture at arbitrary position, preserving privacy and aesthetics. The large number of tags can realize diverse observation points to accommodate arbitrary room layouts, which is impractical by other active units of camera, infrared, radar or lidar. With 20 tags, the system can reliably detect the number of occupants. For 100 tags, occupant posture and location can be known. The technology has been verified in the research labs and test buildings with very high accuracy. When the real-time occupant number can be accurately known without assuming devices on occupants or occupant motion, the building HVAC system can be automated to achieve building energy saving without sacrificing occupant comfort. According to our limited testing in a few types of building models and the simplified cost calculation, the RFID system has low overall cost in production, deployment, operation and maintenance. The signal processing algorithm based on machine learning requires very small number of training cases as most learning is transferrable for various layouts, and very low computational needs during operation, according to our testing in four different room sizes and layouts. In our preliminary estimate from HVAC saving alone, the RFID system can potentially pay for itself within 1.5 years, in addition to the other enhancement in building automation systems (BAS). Our commercialization strategy and business pitch deck focus on venturing this Cornell occupant monitoring technology into BAS and energy management markets. We have identified three broad BAS market segments of senior living, residential buildings, and office buildings. We have put together the minimum viable product characteristics for these identified segments, including analyses on total cost and competing technologies, as well as the fit and technical gaps for these market segments. We intend to bring the technology to market by licensing or partnering with existing BAS vendors. A list of potential collaborators and licensing partner candidates was assembled for different aspects of integrating our technology into a potential product that can be used with BAS.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Distribution System Research Roadmap; Energy Efficiency and Renewable Energy

The scope of the U.S. Department of Energy's Energy Efficiency and Renewable Energy (EERE) office covers a number of distributed energy resource (DER) technologies, including distributed photovoltaics, smart buildings, wind, water, behind-the-meter-storage, and electric vehicles. The impact of these technologies on the distribution system is often assessed with an individual technology focus. Similarly, different technology offices often leverage different sets of tools, leading to analyses that are not comparable. EERE sought the ability to assess the impact of integrating multiple DER technologies, and to comprehensively address DER integration challenges across the portfolio of EERE technologies. This project built on existing work understanding technical challenges, mapped out the key research questions, assessed relevant capabilities across the national laboratory network, identified key gaps, and produced a research roadmap to inform EERE investment decisions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy, Exergy, and Emission Analysis on Industrial Air Compressors

Abstract Air compressors, a key fluid power technology, play an essential role in industrial plants and office buildings, hospitals, and other types of facilities. The efficient use of the air compressor is crucial. By controlling unnecessary inefficiencies, high energy consumption can be reduced. This study aims to provide energy and exergy analysis on air compressors for different industries. Detailed case studies were also analyzed. The case study focuses on the energy and exergy analyses of the compressed air system of foundry industries. The results indicate that applying the six improvement recommendations yields significant amounts of energy and cost savings and significant improvements in the system's overall performance. The payback periods for different recommendations are economically feasible and worthwhile to use. The suggested improvement methods can provide cost savings with a low payback period.

Energy & Fuels↗

Marine Energy Environmental Toolkit for Permitting and Licensing

The permitting and licensing process for marine energy in the U.S. could take up to 7 years for even small demonstrations or pilot studies despite existing resources like Tethys, MarineCadstre, and the FERC E-Library. The goal of the Marine Energy Environmental Toolkit Project was to increase regulators, developers, and marine energy innovators’ understanding of potential environmental effects of marine energy conversion devices deployments and provide information to make efficient and effective determinations during permitting and licensing; develop a one-stop shop for existing environmental, spatial, regulatory, and scientific data that allows users to access disparate sources of data through a series of tags and spatial queries. The Toolkit (marineenergy.app) builds upon prior U.S. Department of Energy (DOE) Water Power Technologies Office (WPTO) investments by pulling from WPTO-funded and outside resources to facilitate the permitting and licensing process, inform technology developers of required permits, and disseminate the latest knowledge of the environmental effects of these devices to regulators, developers, and marine energy innovators and stakeholders.

16 TIDAL AND WAVE POWER↗

Lessons Learned: Summary of Insights From the HERO WEC and Waves to Water Deployments Between 2022 and 2024

In 2020, a team from the National Renewable Energy Laboratory (NREL) partnered with the East Carolina University Coastal Studies Institute to develop a small, modular, wave-powered point absorber desalination prototype. That prototype, known as the hydraulic and electric reverse osmosis wave energy converter (HERO WEC), was intended to de-risk the installation activities planned for the Waves to Water Prize sponsored by the Water Power Technologies Office. The NREL team was given approximately 18 months to design, build, bench test, and deploy the HERO WEC prototype. Since the initial HERO WEC development, it has been used for two in-lab test programs and three ocean deployments. The first in-lab test program focused on ensuring that the overall operation of the device occurred as expected and on validating the operation of safety systems such as pressure relief valves or electrical breakers for load mitigation. The second in-lab test program was the first time the NREL team leveraged NREL’s large-amplitude motion platform to characterize the performance of the HERO WEC. Of the three in-water deployments, the first deployment was effectively an installation and recovery practice with no meaningful wave activity during the time that it was installed. The second deployment was a 2-week effort that enabled both the electric and hydraulic configurations of the device to be in the water for approximately 5 days each. This deployment was also the first time that the team had the opportunity to perform a drivetrain swap on the Coastal Studies Institute research vessel. The third deployment had to be split into two separate installations due to minor damage incurred from the WEC spinning during the initial installation. This report summarizes the deployments, the challenges encountered with each deployment, and the lessons learned for future work.

16 TIDAL AND WAVE POWER↗

Metrics and Analytical Frameworks for Valuing Energy Efficiency and Distributed Energy Resources in the Built Environment: Preprint

This paper summarizes efforts to develop new—and enhance existing—analytical frameworks and metrics to quantify the value that grid-interactive efficient homes with solar (GEB-solar homes) can provide. Industry is working to characterize and understand these capabilities and benefits, but existing analytical frameworks for evaluating energy efficiency (EE) are often siloed from those that evaluate distributed energy resources (DERs). Five metrics were adapted from an extensive literature review and applied to case studies of a modeled home in Riverside, California: ramp up/down, cover factor demand/supply, and curtailable load. Eight different technology scenarios were analyzed using a more tightly connected suite of building-to-grid models (BEopt, REopt, ReEDS, and PLEXOS). Additionally, an initial version of the Cambium tool was developed, characterizing the marginal prices and emissions from NREL’s 2018 Standard Scenarios. These grid costs were extended to a time-varying proxy retail rate and applied as part of a new grid alignment metric. In the results, a more integrated combination of GEB-solar technologies led to a higher cover factor demand—the percentage of gross home load covered by on-site solar—however, a benchmark was required to determine what range of cover factor was “best” for given grid conditions. To that end, a grid alignment cost metric was applied to the case study scenarios. The average cost to serve the net load of the home decreased from a median of ~$0.24/kWh to ~$0.10/kWh when the most integrated technology scenario was optimized towards the grid pricing proxy versus the time-of-use (TOU) rate.

41 EE - Solar Energy Technologies Office (EE-4S)↗

National and Regional Initiatives to Promote Energy Efficiency and Renewable Energy Through State Energy Offices

The National Association of State Energy Officials (NASEO) worked with the U.S. Department of Energy’s (DOE) Office of Energy Efficiency and Renewable Energy (EERE), Weatherization and Intergovernmental Programs Office (WIP) over a ten year period to provide technical assistance, research and analyses, and enhanced coordination between DOE and the State and Territory Energy Offices. Over the life of the agreement, NASEO worked with WIP and the states to provide statewide strategic energy plan analyses and recommendations, including customized technical assistance to the states; peer to peer financing assistance via NASEO’s Financing Committee and supporting activities; training on core energy policies and programs, including dialogues and resources to support energy-air coordination, a training for new State Energy Office Directors, peer to peer exchange via a rural energy taskforce, and support to states to enhance buildings efficiency, home energy labeling, and technology deployment opportunities; support for State Energy Program metrics; and regional coordination via regional coordinators and peer exchange opportunities both in-person and online. Over the life of the project, the position and role of State Energy Offices within state government has changed, with now 80 percent of State Energy Office Directors serving as their Governor’s energy advisor, or reporting directly to their Governor’s energy advisor. This shift in stature has made it ever more crucial for State Energy Offices to receive timely and relevant technical assistance across a range of energy issue areas. NASEO, in collaboration with WIP, was able to deliver this technical assistance, and energy efficiency and renewable energy deployment has accelerated across the country. The State Energy Office Directors and their staff continue to engage in NASEO’s Committees – many of which were supported through this agreement – and have provided formal and informal feedback on the value of the programs supported through this award (e.g., reporting via survey increased understanding of their roles and technical assistance offerings provided by WIP and NASEO following the New Director Trainings). Moreover, resources developed through this award (e.g., Comprehensive State Energy Planning Guidelines, State Energy Loan Fund Database, Rural Data Resources for State Energy Planning and Programs, The Value of Adding home Energy Score to Low-Income Energy Efficiency Programs, etc.) have been cited by states as instrumental to their understanding of specific energy issue areas and in many cases led directly to enhanced program design within a state (e.g. Iowa citing their review of NASEO’s Comprehensive State Energy Planning Guidelines as a necessary first step in their planning process, later following may of the steps outlined in the guidelines). The priorities of the states and federal government have evolved over the last decade, with an increasing focus on climate mitigation and adaptation, equity impacts and considerations, energy security and resilience, and enhanced energy efficiency and renewable energy technology deployment, but the roots of these new priorities are based in the state and federal policies and programs, and research and analyses, that were supported in part through this award and other complementary initiatives. NASEO looks forward to continuing to support the states, and collaborate and coordinate with DOE, as we build on this important foundation in the years ahead.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Comparison of effectiveness and energy use of airborne pathogen mitigation measures to meet clean air targets in a prototypical office building

Organizations such as ASHRAE and the Centers for Disease Control and Prevention (CDC) have proposed guidelines for controlling infectious aerosols in buildings, which can be met through measures such as modified operation of the heating, ventilation, and air-conditioning (HVAC) system or incorporating air-cleaning technologies. However, more research is needed to understand the trade-offs between health, energy, and comfort aspects when designing measures for these guidelines. To address this gap, this paper presents an analysis using new models for air-cleaning technologies, including in-duct and in-room germicidal ultraviolet (GUV) systems and portable air cleaners (PACs). These models are incorporated into an existing prototypical office building model and six measures are designed to meet ASHRAE Standard 241 and CDC clean air targets: MERV 13 HVAC filtration, maximum outdoor air supplied to the building, PACs, and in-duct, upper-room, and whole-room GUV. The measures are simulated for an office building in a cool and humid climate compared against a baseline simulation using MERV 8 filtration. The results show that all measures, except for the maximum outdoor air case, can meet the ASHRAE 241 standard without significant impacts on energy or comfort. The HVAC system measures were not able to meet the CDC target with the default system sizing and lead to significant energy increases, while the in-room measures were able to meet the CDC target with small impacts on energy consumption. Finally, this paper consolidates the simulation findings and provides practical guidance for building operators to meet clean air targets while limiting energy and comfort impacts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Microstructure-Based Understanding of High-Temperature Deformation Behaviors in Laser Powder Bed Fusion (LPBF) 316H Stainless Steel

This report presents the results of high-temperature mechanical property testing and microstructural analysis of laser powder bed fusion (LPBF) 316H stainless steel (SS) conducted during Fiscal Year 2025 (FY25) under the U.S. Department of Energy, Office of Nuclear Energy’s Advanced Materials and Manufacturing Technologies (AMMT) program. The study builds upon prior work by expanding the mechanical property test matrix and advancing a microstructure-based mechanistic understanding of LPBF 316H SS performance, with a focus on the solution annealed (SA, 1100°C for 1 hour) materials. High-temperature tension, creep, fatigue, and creep-fatigue tests were performed. Thermal aging studies were conducted. Advanced characterization techniques, including scanning electron microscopy (SEM), scanning transmission electron microscopy (STEM), and high-energy synchrotron X-ray diffraction, were employed to investigate the microstructural evolution during thermal aging and mechanical testing. It was discovered that the as-built (AB) LPBF 316H SS exhibited precipitation kinetics during thermal aging that are 10–100 times faster than its wrought counterpart due to the presence of high densities of preferred nucleation sites, while the precipitation kinetics in SA LPBF 316H was under investigation. The accelerated precipitation of embrittling phases such as sigma phase in LPBF 316H SS compared to its wrought counterpart led to significant impacts on creep ductility. The influence of laser printing parameters and build orientations on fatigue and creep-fatigue performance was observed. In assessing the creep-fatigue performance, it was discovered that the SA LPBF 316H samples failed in less than 200 cycles under 595°C, 0.5% (strain amplitude) with a 60-minute hold time. This work establishes a mechanistic framework for predicting the long-term behavior of LPBF 316H SS, supporting its rapid qualification under the ASME BPVC. The findings contribute to the broader goal of enabling the deployment of advanced materials in next-generation nuclear energy systems. An outlook for FY26 work, including continued aging studies, mechanical testing, and microstructural characterization, is provided.

36 MATERIALS SCIENCE↗

Community College Energy Code Training Program

The U.S. Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy (EERE) funded a series of research and training programs under the Advanced Building Construction with Energy Efficient Technologies and Practices (ABC) initiative. The aim is to develop new training programs to support the development of a skilled workforce in the building energy efficiency industry. In response, the University of Illinois Smart Energy Design Assistance Center (SEDAC), in collaboration with State Energy Offices in Illinois, Hawaii, and Nevada, developed the Community College Energy Code Training Program. The program is designed to prepare a new generation of energy-literate professionals that understand energy efficiency and its relation to energy codes for new construction and existing buildings through: a) the development of a curriculum and innovative pedagogical materials, b) dissemination through a national network of state energy offices: c) outreach targeting Community College students and instructors.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

TCF - Sustainable Well Cement for Geothermal, Thermal Recovery, and Carbon Storage wells

Primary cementing is the most important operation performed on a subterranean well. Cement, placed in the annulus between the casing and the formations, serves as a hydraulic seal preventing fluids and gas migrations, protecting steel casing from corrosion, and supporting the well structure. Poor cementing jobs can be directly responsible for wells not reaching their full capacity, casing corrosion, compromised well integrity and, in the worst-case scenarios, well collapse. Geothermal, thermal recovery, and carbon storage wells offer environments that are especially difficult for cements to survive while the required lifespan of these wells can be years. In these wells currently used cements cannot provide durable well integrity, and new solutions are necessary. The necessity of stabilizing the electric grid, increasing its flexibility, and providing energy on demand will further expand the market of durable cement solutions for applications in high-temperature underground reservoir thermal energy storage wells (HT RTES). The design challenges of special cement systems for such wells originate from chemistry limitations of currently used well cements, aggressive environments, temperature and repeated shock conditions associated with them, and very weak formations that are not uncommon in these wells. During the last 70 years the most common systems for thermal-well construction have been Ordinary Portland Cement (OPC) (absolute majority of the wells), silica-lime system, and high aluminum cement-containing formulations. The major issues of calcium-silicate hydrates, that form during the hydration of OPC resulting in hardened material, are their poor chemical resistance to acids due to the calcium interactions with acid anions followed by its eventual dissolution, even in mild acids, such as carbonic acid from CO 2 dissolution, and inadequate bonding to the steel causing serious casing corrosion problems (Sugama & Pyatina, 2019). Performance of OPC-based cement may be significantly improved with organic additives; however, those are limited by their temperature stability. An alternative to calcium-silicate cement was developed by BNL and commercialized by Halliburton as ThermaLock TM cement. Calcium-aluminate-phosphate-based chemistry of the material allowed overcoming acid-resistance problems of OPC, especially in CO 2 -rich geothermal environments. In 2012-2015, building upon this experience, BNL developed Thermal Shock Resistant Cement (TSRC) with the support of Geothermal Technology Office (GTO) of DOE. TSRC has high-temperature stable chemistry, superior properties of cement-metal casing bond and corrosion protection (4-times better than currently used OPC-based formulation), significantly outperforms common well-cements in thermal-shock tests, has self-healing properties, and like ThermaLock TM is CO 2 resistant incorporating carbonate ions into stable hydrates (Gill et al., 2012).

15 GEOTHERMAL ENERGY↗

Acoustic-based monitoring and machine learning of component status for microreactor applications

This report provides a description and assessment of recent efforts to couple acoustic-based experimental measurements and characterization with machine learning models in order to enhance structural health monitoring capabilities for nuclear microreactors. With resilient embedded sensors in development by others supported by programs funded by the US Department of Energy’s Office of Nuclear Energy, the work described herein builds upon ongoing efforts to improve non-destructive testing technology that relates measured acoustic signatures to component stresses and/or structural defects, using a combination of new experimental measurements and machine learning architectures. The experimental procedure remained similar to that developed for the previous year’s demonstration of damage detection by the authors, with the same damaged sample tested under similar applied stress conditions. Notably, a new mounting fixture was designed and implemented to improve measurement consistency and a more sophisticated laser Doppler vibrometer was employed to make high-fidelity vibration measurements. Two nominally identical sets of training data were collected for each experimental setup to better understand the repeatability of the experiment and to better test the generality of trained neural network models. Additionally, we obtained new high-quality 3D mode shapes of the damaged test article at various stress and excitation levels, providing greater insights into the physical response of the sample during testing. Previously, we demonstrated that a machine learning model based on a convolutional neural network can predict structural details of an artificially introduced interface (intact, rough cut, smooth cut), and the applied torque level. In this study, we have transitioned to graph-based neural network architectures to better develop and test a flexible framework that is more suitable to being transferred away from controlled benchtop experiments and into more applied settings where less-structured data inputs may be expected. In general, performance testing of a graph neural network on frequency-domain representations of the data indicates strong and consistent identification of test conditions for datasets recorded on damaged components. With goals of predicting damage location and other changing experimental conditions using limited datasets, predictive models using a graph neural network architecture correctly predicted the applied torque level with an accuracy of 85% using only a single measurement point and predicted within one torque level in 95% of test windows. Predictions of damage location had limited success due to the symmetry and minimal number of the damage scenarios presented during model training. Results were ambiguous as to whether the model could detect the location of the artificial damage, or if it was instead learning the location of a given measurement point on the part and subsequently detecting which points were closest to the location of the damage. This finding will be factored into upcoming planned work on damaged graphite components, where new experimental tests with a larger number and variety of damage scenarios are expected to provide improved validation of recent developments in monitoring methodology.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Deployment Readiness Framework for Marine Energy

As electricity prices continue to rise and extreme weather events related to climate change become more frequent, many island and remote coastal communities are prioritizing their energy future. Isolated locations and coastal environments pose challenges for energy costs and grid resilience, but the ocean can be a key solution. Marine energy could provide these communities with clean, affordable, and reliable power. The U.S. Department of Energy's (DOE) National Renewable Energy Laboratory and Pacific Northwest National Laboratory are developing the Deployment Readiness Framework (DRF) to support remote, coastal, and island community-driven energy transitions. This framework can be used to better understand the readiness of communities for marine energy technology demonstration projects and their operation. The DRF builds on the Energy Transitions Initiative Partnership Project (ETIPP) supported in part by DOE's Water Power Technologies Office.

community readiness↗

Photovoltaic windows cut energy use and CO 2 emissions by 40% in highly glazed buildings

Buildings account for 30% of global energy use. The architectural trend across building sectors is toward more glass despite higher energy use and carbon emissions than opaque cladding alternatives. Numerous window technologies - low-emissivity coatings, triple glazing, dynamic tinting, and the more recently developed photovoltaic glass - have emerged in the last two decades as approaches to reduce building energy. However, a comprehensive understanding of where and how these window technologies can be installed to enable optimal energy savings under different climate conditions remains limited. Here we test window technologies using thousands of macroscale building-energy simulations for different climate zones and building designs to evaluate the associated net energy use and carbon-emissions reduction potential. Novel window technologies, especially photovoltaic windows with high thermal performance, offer energy savings in all climates, ranging from 10,000-40,000 GJ per year over substandard windows for a typical office building, resulting in up to 2,000 tons of annual CO 2 emissions reduction. Highly glazed, net-zero buildings are achievable via photovoltaic windows when combined with careful geometric considerations.

14 SOLAR ENERGY↗