Search NASA⌕ Search

SEARCH · Search NASA

Results for “CADMIUM TELLURIDE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Advances in CdZnTeSe for Radiation Detector Applications

Detection of X- and gamma-rays is essential to a wide range of applications from medical imaging to high energy physics, astronomy, and homeland security. Cadmium zinc telluride (CZT) is the most widely used material for room-temperature detector applications and has been fulfilling the requirements for growing detection demands over the last three decades. However, CZT still suffers from the presence of a high density of performance-limiting defects, such as sub-grain boundary networks and Te inclusions. Cadmium zinc telluride selenide (CZTS) is an emerging material with compelling properties that mitigate some of the long-standing issues seen in CZT. This new quaternary is free from sub-grain boundary networks and possesses very few Te inclusions. In addition, the material offers a high degree of compositional homogeneity. The advancement of CZTS has accelerated through investigations of the material properties and virtual Frisch-grid (VFG) detector performance. The excellent material quality with highly reduced performance-limiting defects elevates the importance of CZTS as a potential replacement to CZT at a substantially lower cost.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Four–Terminal Perovskite–CdSeTe Tandem Solar Cells: From 25% toward 30% Power Conversion Efficiency and Beyond

Thin-film tandem photovoltaic (PV) technology has emerged as a promising avenue to enhance power conversion efficiency beyond the radiative efficiency limit of single-junction devices. Combining a tunable wide-bandgap perovskite cell with a commercially established narrow-bandgap cadmium selenium telluride (CdSeTe) cell in a comparatively easy-to-fabricate four-terminal (4-T) arrangement is a great step in that direction. Herein, the impact of the transparent back contact and the perovskite absorber bandgap on the performance of 4-T perovskite–CdSeTe tandem solar cells is investigated. 4-T perovskite–CdSeTe tandem device architecture with ≈25% efficiency is demonstrated and a feasible pathway is shown to improve the tandem efficiency to more than 30%. Furthermore, the results show that the integration of CdSeTe with perovskite in 4-T tandem PV configurations represents a significant advancement toward achieving higher efficiency and low-cost tandem PVs.

14 SOLAR ENERGY↗

Copper iodide nanoparticles as a hole transport layer to CdTe photovoltaics: 5.5 % efficient back-illuminated bifacial CdTe solar cells

We report the role of copper iodide (CuI) nanoparticles (NPs) as a hole transport layer (HTL) in cadmium sulfide/cadmium telluride (CdS/CdTe) photovoltaics. These CuI NPs were prepared using solution processing at room temperature and used to fabricate monofacial and bifacial CdTe solar cells with different back contacts. Using CuI/Au as the back contact, the device efficiency reached to 14.8% with outstanding fill factor (FF) of 79.2%. Replacing the gold (Au) electrode with sputtered transparent indium tin oxide (ITO), a CuI/ITO back contact yielded photoconversion efficiencies (PCEs) of 11.6% and 5.5% under front and back illumination respectively. Bifacial devices (CdTe/ITO) without the CuI NP HTL have an efficiency of 7.0% and 1.0% for front and back illumination, respectively. For CuI/ITO, a current collection of 12.0 mAcm -2 was observed upon back illumination which significantly improved over an ITO-only back contact (5.0 mAcm -2 ). The PCE obtained from back illumination was enhanced when using CuI NPs as the HTL due to the reduced back barrier height, and improved back interface as determined by temperature dependent current vs. voltage characteristics and impedance spectroscopy analysis. The improvement in device performance of the bifacial configuration is a significant step forward toward realizing thin film photovoltaic modules which harvest energy incident on the rear of the module.

36 MATERIALS SCIENCE↗

Detector Performance on Surface Passivation and its Long-Term Stability

Surface passivation is an ideal technique to prepare the surfaces of fabrication Cadmium Zinc Telluride (CZT) and related semiconductor devices such as Cadmium Zinc Tellurium Selenide (CZTS). Surface passivation techniques reduce the effects of aging in the detector [1]. Surface performance effects on material performance can result in fluctuations in energy resolution over time (such as periods of a year or more). The long-term stability of surface passivation with Potassium Hydroxide (KOH) was observed with measurement of 1) current (nano Amp) vs voltage (V) and 2) spectral response and energy resolution throughout the years. Three CZTS detector samples of M2, M3, and M4 were examined using a photomultiplier tube and voltage amplifier. The Bridgman technique is used to grow the CZTS used in this study.

Johnson, Kirsten [Morgan State Univ., Baltimore, M↗

Atomistic modeling of energy band alignment in CdSeTe surfaces

Atomistic modeling based on Desnity Functional Theory (DFT)- 1/2 method coupled with surface Green’s function has been employed to investigate the energy band alignment results in cadmium selenium telluride (CdSeTe) surfaces. The structural and electronic properties of the bulk ternary alloy were established before cleaving the CdSeTe low index surface facets. The dependency of atomic-scale electronic features on different plane orientations was explored by studying the energy band alignment diagrams in the unreconstructed and reconstructed surfaces. While the low index CdSeTe surface geometry reconstructions replicate the CdTe surface geometries, the energy band alignment features of the unreconstructed and reconstructed CdSeTe surfaces differ from those observed in CdTe low index surfaces. The structurally relaxed reconstructed CdSeTe surface results in purely flat bands as opposed to an internal cusp feature observed in CdTe surfaces. The presence of an internal energy cusp in CdTe(111) surfaces is expected to play a key role in enhancing the hole charge transport towards the back of CdTe-only solar cell device and the absence of such feature in CdSeTe surface may explain one of the reason for the lower performance of CdSeTe-only solar cell seen experimentally.

36 MATERIALS SCIENCE↗

Quantum Dot Based Solid-State Radiation Detectors

The detection and accurate identification of nuclear material is critical to the advancement of national security, medical technology, and environmental prosperity. The gold standard solid-state detector HPGe, suffers from high manufacturing costs and the need to operate at cryogenic temperatures to ensure reliable energy resolution. The other most common solid-state detector, cadmium zinc telluride (CZT), has the ability to operate at room temperature, but the grow process results in impurities decreasing performance. In this paper we have developed a continuous flow synthesis able to mass produce targeted size cadmium selenide quantum dots. The implementation of these QDs in QD/MEH-PPV composites has the ability to rival HPGe energy resolution at room temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of the Electric Field Strength on the Energy Resolution of Cr/CdTe/Pt Detectors

The electrical and spectrometric characteristics of the Cr/cadmium telluride (CdTe)/Pt structure with a metal-semiconductor type rectifying contact, used in X/γ-ray detectors, are investigated. For the detectors fabrication, chlorine-doped CdTe crystals with a resistivity of (3-6) × 10 9 Ω cm at 293 K were used. 137Cs spectra and their modification by applied voltage change were obtained. The reverse bias voltage corresponding to the best energy resolution of the Cr/CdTe/Pt structure is experimentally determined. The concentration of impurities N in the crystal, which determines the thickness of the space-charge region, is estimated. Finally, an energy resolution deterioration of the Cr/CdTe/Pt structure with increasing voltage is explained due to the Gunn effect.

47 OTHER INSTRUMENTATION↗

Radioactive Source Localization via Bayesian Particle Filter

In the event of a misplaced radioactive source or other emergency situation, measuring a radiation field, mapping its distribution, and determining a source location are essential tasks to ameliorating the situation. However, radiation fields may be extremely hazardous to human surveyors and minimizing received radiation doses is just as essential. Robots appear to be a potential solution to these problems. Beyond simply measuring radiation, the robot's computer processing capabilities offer a way to apply complex data analysis methods to radiation measurements in real-time. Methods which predict likely source locations can then feed this information into other processes, potentially improving path planning and enabling more efficient measurements. Given a robot mounted with a gamma-ray detector, can we: develop a methodology to account for detector performance across a wide range of source angles, distances, and photon energies? operate an autonomously navigating robot to effectively survey and characterize an area of interest? implement a data analysis method, conventionally used in measurements of motion, for source localization purposes? An open-source TurtleBot 3 robot, running Robot Operating System (ROS) on Ubuntu 16.04 LTS, was fitted with a Kromek GR1{sup R} Cadmium Zinc Telluride (CZT) solid-state gamma-ray detector. As a part of ROS, the packages OpenSlam, gmapping, and amcl were used to perform Simultaneous Localization and Mapping (SLAM), determining the robot's position and mapping the surrounding area. Data was acquired via Lidar mounted on top the TurtleBot 3. Detector Calibration Fit: The equation was fit to 365 counts of various energies, distances, and angles. A MATLAB{sup R} program was written to simulate measurements taken a robot on a random walk, with count data and positions discretized into finite element pixels. Using this program, a sample of 100 runs was performed on a map with a simulated source at the center, with a total of 200 of 2 pixels each. Similarly, multiple runs of the filter were performed on recorded robot measurement data. In both simulation and real tests, when corrected for errors (particles placed outside of bounds or on the robot, and simulation-specific errors), corresponding t-tests of predicted x and y-coordinates were within a 95% confidence interval of the actual position. For the real trial, these positions are slightly skewed right in the x-axis as the robot remained mainly to the left side of the source within the sample area. These simulations demonstrate potential validity for the usage of a particle filter as method of radioactive source localization. In the future, true real-time implementation and data fusion may further augment the performance of the robot to localize lost sources. Additionally, identification of multiple sources, determination of source types, and usage of a collimator are areas to potentially be explored.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Remote Radiation Sensing Using Aerial and Ground Platforms

Remote sensing of ionizing radiation has a significant role in waste management, nuclear material management and nonproliferation, and radiation safety. Robotic platforms can surpass the number of tasks that are achieved by humans. With this technique, the operator's radiation exposure can be decreased. Remote sensing allows for the evaluation and monitoring of radiological contamination. Gamma-ray and neutron sensors were integrated onto the robotic platforms. This approach allows for the radiation sensor data to be dynamically tracked and mapped thus enabling further analysis of the radiation flux in temporal and spatial domains. The goal is to complete scheduled tasks while the robot is being irradiated. To achieve this, electronic components must be shielded and radiation hardened. CZT Detector: Cadmium Zinc Telluride (CZT) detector technology has been a promising solution for gamma-ray and x-ray measurements. Detector data is transferred to the Odroid minicomputer that controls and powers the module via the USB. Robot Operating System (ROS) was utilized for data acquisition and data fusion. The Mariscotti method was employed for the spectrum analysis. A function was programmed in ROS for the automatic identification of photopeaks. CLYC Detector: A Cs{sub 2}LiYCl{sub 6}:Ce{sup 3+} (CLYC) detector was used for simultaneous medium-resolution gamma-ray measurements and neutron counting. A 2.54 cm diameter photomultiplier tube (PMT) was equipped with a high voltage supply and a miniature digitizer. Gamma-ray excitation: fast core-to-valence luminescence (CVL) with 1 ns decay constant, and prompt Ce{sup 3+} emission with 50 ns decay constant. Neutron excitation: slow cerium self-trapped excitation (Ce{sup 3+} STE), 1000 ns decay constant. Radiation Source Localization: Maximum Likelihood Estimation (MLE) and gradient-based methods were used to locate the position of a radiation source based on measured radiation intensities. Multi-Particle Transport Code FLUKA: Estimation of radiation damage of the electronic components is important in order to optimize the robot's operational time while it is irradiated. Displacement per atom (DPA) represents the radiation damage in materials exposed to the ionizing radiation. Various shielding layers of different thickness t were analyzed (< 5% statistical error). The model of the controller of the UAS was designed in FLUKA. Conclusion: CZT and CLYC detectors were integrated onto the robotic platforms. Radiation source localization and contour mapping using robotic platforms were studied. Functions for data analysis and fusion were developed in ROS. FLUKA code was utilized to analyze DPA values. Layers of low-density and high-density materials were used to shield the UAS electronics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low-Temperature Gold Deposition Improves CdTe Back Contacts

Improved back contacts can benefit CdTe photovoltaics (PV). In this work, Cd(Se,Te) PV absorbers are cooled during Au evaporation to thermally quench a chemical reaction occurring between gold and CdTe and the generation of a reaction product that lowers device efficiency. Reducing substrate temperature enhances PV power conversion efficiency via open-circuit voltage and fill factor increases. X-ray photoelectron spectroscopy (XPS) reveals that lower temperature also reduces chemical perturbations of the CdTe, potentially linking back contact formation to a CdTe degradation product that hinders PV performance. Comparing reaction enthalpy and substrate heating energy shows that back contact formation by sputtering elemental metals onto ZnTe may exhibit a degradation pathway analogous to that of CdTe/Au reported here. Degradation-diminishing contact formation processes are therefore of general interest for optoelectronic devices, and the reduced substrate temperature in this study is one example.

14 SOLAR ENERGY↗

Evaluation of a Variable-Aperture Full-Ring SPECT System using Large-Area Pixelated CZT Modules: A Simulation Study for Brain SPECT Applications

Single photon emission computed tomography (SPECT) scanner using cadmium zinc telluride (CZT) offers improved imaging capability over conventional NaI (Tl)-based SPECT scanner. We aim to demonstrate a full-ring SPECT system design with eight large-area CZT detectors that can be used for a broad spectrum of SPECT radiopharmaceuticals and provides higher sensitivity and better spatial resolution than those of conventional NaI (Tl)-based gamma cameras. A newly-designed full-ring SPECT system is composed of 8 large-area CZT cameras (128 mm × 179.2 mm effective area) that can be independently swiveled around their own axes of rotation independently and can have radial motion for varying aperture sizes that can be adapted to different sizes of imaging volume. Extended projection data were generated by conjoining projections of two adjacent detectors to overcome the limited field-of-view (FOV) by each CZT camera. Using Monte Carlo simulations, we evaluated this new system design with digital phantoms including a Derenzo hot-rod phantom and a Zubal brain phantom. Comparison of performance metrics such as spatial resolution, sensitivity, contrast-to-noise ratio (CNR), and contrast-recovery ratio were made between our design and a conventional SPECT scanner. The proposed scanner could result in up to about 3 times faster in acquisition time over conventional scan time at same acquisition time per step. The spatial resolution of our proposed scanner was similar or better to that of the conventional scanner, and there was significant performance improvement over the conventional scanner particularly in sensitivity (approximately 4 times). Overall, we successfully reconstructed the phantom image for both 99 mTc-based perfusion and 123 I-based dopamine transporter (DaT) brain studies simulated for our new design. In particular, the striatal/background contrast-recovery ratio in 3-to-1 reference ratio was over the 0.8 for the 123 I-based DaT study. In conclusion, we demonstrated the potential of our new full-ring CZT SPECT design, showing improved performance metrics such as improved system sensitivity and CNR while maintaining other important imaging parameters such as spatial resolution.

36 MATERIALS SCIENCE↗

Simulation studies of a full-ring, CZT SPECT system for whole-body imaging of 99m Tc and 177 Lu

Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. With the goal of filling this technological gap, we have designed a cadmium zinc telluride (CZT) full-ring SPECT scanner instrumented with a broad-energy tungsten collimator. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT does not rely on the dual- and the triple-head rotational SPECT standard paradigm, enabling a larger effective area in each scan to increase the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized phantoms filled with 99m Tc and 177 Lu. Our SPECT design can resolve 7.9 mm rods for 99m Tc (140 keV) and 9.5 mm for 177 Lu (208 keV) in a hot-rod Derenzo phantom with a 3-min exposure and reach an image contrast of 78% for 99m Tc and 57% for 177 Lu using the NEMA IQ phantom with a 6-min exposure. Our modified scatter correction shows an improved contrast-recovery ratio compared to a standard correction. In this paper, we demonstrate the good performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99m Tc imaging of brain perfusion and 123 I imaging of dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design provides similar IQ and contrast to the commercial full-ring SPECT VERITON for 99m Tc. Regarding 177 Lu imaging of the 208 keV emissions, our design provides similar contrast to that of other state-of-the-art SPECTs with a significant reduction in exposure. In conclusion, the high sensitivity and extended energy range up to 250 keV makes our SPECT design a promising alternative for clinical imaging and theranostics of emerging radionuclides.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Forming Gas Annealing Improves the Performance of Ex Situ Sb-Doped CdSeTe Thin-Film Solar Cells

Group V doping in cadmium-selenide-telluride (CdSeTe) polycrystalline thin-film solar cells has demonstrated improved power conversion efficiencies (PCEs) and long-term stabilities as compared to the traditional Cu doping in the last decade. The dopants can be successfully incorporated by either in situ or ex situ doping. Here, we report that forming gas (FG) annealing enhances the efficiencies of CdSeTe polycrystalline thin-film solar cells utilizing ex situ antimony (Sb) doping via close-space sublimation of SbCl3 at ambient pressure. The FG annealing increases the hole density and carrier lifetime, reduces the back barrier height, and, therefore, leads to improved open-circuit voltages (VOCs) and fill factors (FFs). The champion device achieves a PCE of 19.2% with a VOC of 877 mV, a current density (JSC) of 30.2 mA/cm2, and an FF of 72.4%. Importantly, the Sb-doped devices showed improved stability under stress tests as compared to Cu-doped devices.

14 SOLAR ENERGY↗

Titanium Carbide MXene Hole Contacts for CdTe Photovoltaics

CdTe is a high‐efficiency thin‐film photovoltaic technology that has seen tremendous commercial success over the past decade. Yet despite the improvement of other device characteristics, the fabrication of an ohmic hole back contact layer has remained a challenge due to the high ionization potential of CdTe, which limits the external potential that can be feasibly reached even as other characteristics of the device improve. MXenes, a family of 2D materials with rapidly growing scientific and commercial interest, offer a promising route to forming low‐cost, low‐barrier contacts due to their demonstrated high work function, metallic conductivity, and facile solution processing from benign solvents. Here, it is shown that Ti 3 C 2 T x MXene films processed from an aqueous colloidal dispersion can perform as a highly efficient hole contact material for CdTe solar cells, resulting in high power‐conversion efficiencies. The role of the Schottky barrier formation in Ti 3 C 2 T x ‐contacted CdTe devices is probed, and potential pathways for the future development of this potent combination of materials are elucidated. The modularity of the expansive MXene family of materials presents a promising strategy for developing next‐generation hole contacts for CdTe solar cells.

14 SOLAR ENERGY↗

Codesigning Alloy Compositions of CdSe y Te 1− y Absorbers and Mg x Zn 1− x O Contacts to Increase Solar Cell Efficiency

Thin‐film solar cells such as CdTe are a major commercial photovoltaic technology, with more than 25 GW installed worldwide and levelized costs of electricity competitive with fossil fuels. Further progress may result from integrating CdSe y Te 1− y absorbers with Mg x Zn 1− x O contacts, but the device efficiency is difficult to maximize due to coupled dependence on chemical composition of both alloys. Herein, a high‐throughput approach is demonstrated to codesign chemical compositions in alloyed Mg x Zn 1− x O/CdSe y Te 1− y thin‐film solar cells, using combinatorial libraries of PV devices with orthogonal composition gradients in CdSe y Te 1− y absorbers and Mg x Zn 1− x O contacts. It is found that the solar cell performance is a strong and coupled function of both elemental compositions, with efficiency up to 17.7% ( V OC = 836 mV, fill factor = 69%, J SC = 30.6 mA cm −2 ) at atomic compositions of Mg/(Mg + Zn) ≈18% and average Se/(Se + Te) ≈4%. These performance trends among >100 devices are explained by >100 ns lifetime of photoexcited charge carriers at the Mg x Zn 1− x O/CdSe y Te 1− y interface where strong Se accumulation is also observed. This study reports the optimal compositions of the commercially relevant Mg x Zn 1− x O/CdSe y Te 1− y solar cells and demonstrates a general approach to codesigning performance of alloyed thin‐film solar cells and other optoelectronic devices.

14 SOLAR ENERGY↗

Role of Selenium in CdZnTeSe as a Defect Engineering Agent

Cadmium zinc telluride (CdZnTe) with 10 atomic % Zn has been the material of choice for room-temperature semiconductor compact X- and gamma-ray detector applications for over three decades. Despite its commercial success as the most desirable room-temperature semiconductor radiation detection material, CdZnTe (CZT) suffers from a lack of compositional homogeneity on both the micro- and macroscales and the presence of high concentrations of performance-limiting defects such as subgrain boundary networks (dislocation walls) and secondary phases (Te-rich inclusions). Random distributions of these defects in the CZT matrix result in the spatial inhomogeneity of the material’s charge-transport properties. The recently discovered quaternary Cd x Zn 1-x Te 1-y Se y (CZTS) has experienced remarkable advances in its material properties, with highly reduced defects and higher compositional homogeneity. This book chapter focuses on the presence of performance-limiting defects in CZT that have thus far hindered the yield and cost of high-quality detectors and restricted their widespread deployment for a variety of potential applications, particularly for their use as large-volume gamma detectors, where the demands on material perfection are significantly greater. This chapter also provides an overview of the recent developments in the quaternary material CZTS, particularly the effects of selenium (Se) in the CZTS matrix on the defect engineering of the quaternary alloy material and the advancement of CZTS as a potential next-generation detector operable at room temperature.

Roy, Utpal N.↗

Structural and Electronic Properties of Indium-Doped n-type Cd-Se-Te Crystals

Here, we present a comprehensive investigation into the potential of n-type indium-doped cadmium selenide telluride (CST:In) as a high-performance candidate for solar cell applications, without the need for resource-intensive post-growth treatments that are required for CdTe:In. We compared undoped CST and CST:In crystals under different growth conditions, analyzing their structural and electronic properties using x-ray diffraction (XRD), electron probe microanalysis (EPMA), current-voltage (IV) and Hall effect measurements, time-resolved photoluminescence (TRPL), optical transmission, and photoluminescence (PL) mapping. The results reveal that as-grown CST:In crystals achieve nearly 100% carrier activation, yielding an electron concentration of 9.5x1018 cm -3 , mobility of 653 cm 2 /V.s and a 5 ns lifetime which approaches the radiative limit. Furthermore, comparison of PL maps from crystal growths having different cooling profiles suggests a strong effect of cooling rate on selenium segregation and cubic/hexagonal/polytype phase distribution. Slower cooling leads to a more homogeneous cubic structure with lower Se segregation, while a faster cooling rate results in increased Se segregation, and twin boundaries and stacking faults with polytypic and hexagonal character.

14 SOLAR ENERGY↗

Methods for estimating X-ray machine output through measurement and simulation

We report ball grid arrays are increasingly being applied in the electronics industry and may require X-ray inspection to ensure the integrity and correct placement of solder pins. However, as the architecture of integrated circuits continues to narrow while simultaneously growing more complex, the risk of electronic failure due to radiation damage increases. While medical X-ray devices have been held to high standards and are repeatedly shown to be well characterized, devices used for electronic inspection are often lacking detailed characterization. This study presents unique methods to solve for important properties in X-ray inspection devices such as source to object distance and energy spectrum. This information can then be applied to Monte Carlo models to achieve better overall dose estimates to electronics, which will lead to superior manufactured products. Since X-ray devices can vary greatly in source characteristics, this work investigates spectral measurement and Monte Carlo representation of three X-ray devices. For a Philips SRO 33 100 medical diagnostic device, the spectral output followed expected trends given by the prediction software SpekCalc and Spektr. For the Dage XD7500NT, direct measurement showed a spectral artifact that through the use of Gafchromic films, was shown to be a contributing effect in the dose output. For the Rad Source RS1800, a high powered irradiation device, direct spectral measurement was not achieved. However, a Monte Carlo model using an assumed spectra was found to match ion chamber measurements to a high degree.

47 OTHER INSTRUMENTATION↗