242 PU Standards Documentation Package

The standards documented in this package are composed of plutonium oxide. One set of standards was fabricated from 84% 242 pu material and the other 89% 242 pu material. They were specifically designed to be used as calibration standards for thermal neutron counters (TNCs). The procedure used to prepare these standards is part of the documentation package.

07 ISOTOPE AND RADIATION SOURCES↗

Comparison of the calculated absorbed dose using the Cadplan™ treatment planning software and Tld-100 measurements in an Alderson-Rando phantom for a bronchogenic treatment

To verify the accuracy of the absorbed doses D calculated by a TPS Cadplan for a bronchogenic treatment (in an Alderson-Rando phantom) are chosen ten points with the following D's and localizations. Point 1, posterior position on the left edge with 136.4 Gy. Points: 2, 3 and 4 in the left lung with 104.9, 104.3 and 105.8 Gy, respectively; points 5 and 6 at the mediastinum with 192.4 and 173.5 Gy; points 7, 8 and 9 in the right lung with 105.8, 104.2 and 104.7 Gy, and 10 at posterior position on right edge with 143.7 Gy. IAEA type capsules with TLD 100 powder are placed, planned and irradiated. The evaluation of the absorbed dose is carried out a curve of calibration for the LiF response (nC) {sup vs} {sup DW}, to several cavity theories. The traceability for the DW is obtained with a secondary standard calibrated at the NRC (Canada). The dosimetric properties for the materials considered are determined from the Hounsfield numbers reported by the TPS. The stopping power ratios are calculated for nominal spectrum to 6 MV photons. The percent variations among the planned and determined D in all the cases they are < ± 3%.

60 APPLIED LIFE SCIENCES↗

Measuring cosmological distances using cluster edges as a standard ruler

ABSTRACT The line-of-sight velocity dispersion profile of galaxy clusters exhibits a ‘kink’ corresponding to the spatial extent of orbiting galaxies. Because the spatial extent of a cluster is correlated with the amplitude of the velocity dispersion profile, we can utilize this feature as a gravity-calibrated standard ruler. Specifically, the amplitude of the velocity dispersion data allows us to infer the physical cluster size. Consequently, observations of the angular scale of the ‘kink’ in the profile can be translated into a distance measurement to the cluster. Assuming the relation between cluster radius and cluster velocity dispersion can be calibrated from simulations, we forecast that with existing data from the Sloan Digital Sky Survey we will be able to measure the Hubble constant with 3.0 per cent precision. Implementing our method with data from the Dark Energy Spectroscopic Instrument (DESI) will result in a 1.3 per cent measurement of the Hubble constant. Adding cosmological supernova data improves the uncertainty of the DESI measurement to 0.7 per cent. While these error estimates are statistical only, they provide strong motivation for pursuing the necessary simulation program required to characterize and calibrate the systematic uncertainties impacting our proposed measurement. Whether or not our proposed measurement can in fact result in competitive H0 constraints will depend on what the eventual systematics floor for this method is.

79 ASTRONOMY AND ASTROPHYSICS↗

Binary pseudo-random array for calibration of interferometers with transmission spheres and cylinders

Binary pseudo-random array (BPRA) “white noise” artifacts are highly effective for characterizing the instrument transfer function (ITF) of surface topography metrology tools and wavefront measurement instruments. These BPRA artifacts feature all spatial frequencies within the instrument bandpass equally, resulting in a power spectral density with a white-noise-like character. This characteristic allows for direct ITF determination with uniform sensitivity across the entire spatial frequency range. We have developed a novel BPRA calibration standard that combines the diffractive pattern of a reflection computer-generated hologram (CGH) with the white noise generating BPRA pattern. By integrating these technologies using the same lithographic techniques, the resulting calibration sample enables ITF characterization of a Fizeau interferometer with a transmission sphere, or any nulling optic.

Munechika, K↗

Monitoring the Caustic Dissolution of Aluminum Alloy in a Radiochemical Hot Cell Using Raman Spectroscopy

Chemical processing of highly radioactive materials commonly takes place in heavily shielded hot cells. The remote, real-time monitoring of chemical processing streams via optical spectroscopic techniques in hot cells may be particularly useful. Here in this paper, we describe the implementation of Raman spectroscopy and chemometric analysis to monitor the dissolution of aluminum-clad targets containing irradiated aluminum–neptunium oxide cermet pellets in caustic solutions in a hot cell environment. Partial least squares regression analysis was used to generate calibration models to quantify the concentration of dissolved aluminum, nitrate, and hydroxide in solutions within the radiochemical hot cell. This work explored a systematic approach to optimize a matrix of calibration standards using a D-optimal experimental design. The Design of Experiments-based regression model, in comparison to more traditional analytical approaches, was found to be the more practical method for building calibration models, with fewer samples, to obtain informative analytical data from Raman spectra.

36 MATERIALS SCIENCE↗

Development and field testing of a rapid and ultra-stable atmospheric carbon dioxide spectrometer

We present field test results for a new spectroscopic instrument to measure atmospheric carbon dioxide (CO 2 ) with high precision (0.02 μmol mol -1 , or ppm at 1 Hz) and demonstrate high stability (within 0.1 ppm over more than 8 months), without the need for hourly, daily, or even monthly calibration against high-pressure gas cylinders. The technical novelty of this instrument (ABsolute Carbon dioxide, ABC) is the spectral null method using an internal quartz reference cell with known CO 2 column density. Compared to a previously described prototype, the field instrument has better stability and benefits from more precise thermal control of the optics and more accurate pressure measurements in the sample cell (at the mTorr level). The instrument has been deployed at a long-term ecological research site (the Harvard Forest, USA), where it has measured for 8 months without on-site calibration and with minimal maintenance, showing drift bounds of less than 0.1 ppm. Field measurements agree well with those of a commercially available cavity ring-down CO 2 instrument (Picarro G2301) run with a standard calibration protocol. This field test demonstrates that ABC is capable of performing high-accuracy, unattended, continuous field measurements with minimal use of reference gas cylinders.

Xiang, B.↗

A proposed high-intensity radiometer calibration method using concentrated solar radiation

Accurate calibration of irradiance measurement devices, or radiometers, is essential for ensuring the reliability of measurements in high heat applications such as concentrating solar power (CSP), aerospace, defense, and pulsed power systems. Despite the critical need, existing calibration standards and service providers are limited to irradiance levels below 100 kW/m 2 and specific radiation sources, which is insufficient for many applications. For instance, CSP technologies, particularly those under the Department of Energy’s Solar Energy Technologies Office (SETO) Gen 3 program, require accurate measurements of broadband irradiance at levels exceeding 2000 kW/m 2 . In even more extreme scenarios, such as re-entry vehicles, heat levels can surpass 10000 kW/m 2 . Current ISO standards, specifically ISO 14934–2 and ISO 14934–3, are constrained to lower irradiance levels and dependent on black body heat sources, limiting their applicability for high-intensity broadband irradiance measurements, particularly in concentrated solar applications. Here, to address this shortfall, the National Solar Thermal Test Facility (NSTTF) at Sandia National Laboratories (SNL) proposes a calibration method and facility capable of characterizing radiometers up to 2750 kW/m 2 using concentrated solar irradiance. Calibrating with concentrated sunlight is important for solar applications as it aligns the calibration process with the solar spectrum. This alignment is crucial for minimizing systematic errors and avoiding the need for additional corrections that may arise when radiometers designed for solar applications are calibrated using black-body or electrical sources. This paper presents the present day NSTTF characterization facility and procedure, detailing the proposed calibration method and uncertainty quantification. The presented method builds upon 1980′s NSTTF methodology and involves both theoretical and empirical methods to establish a robust relationship between gauge voltage output and irradiance intensity, quantifying both measurement and fitting errors. By addressing the limitations of existing standards and extending the characterization range, this work provides an advancement in the field of high-intensity irradiance measurement and instrumentation characterization.

Gardon gauge↗

Scatter Removal using Black Body Grids and Determining the Minimum Resolvable Hydrogen Concentration at MARS

This dataset was used to develop and validate a scatter-correction pipeline for neutron radiographs acquired at the MARS beamline, based on the methodology of Carminati et al. (2019). Scatter removal was performed using 36 gadolinium black bodies to characterize and remove the spatially varying neutron scatter field that cannot be eliminated by conventional open-beam normalization. The dataset comprises eight samples - four single-crystal nickel and four polycrystalline austenitic 316L stainless steel. Within each material system, samples were pre-charged with hydrogen gas at four charging pressures (1.5, 5, 12.5, and 20 kpsi). Following scatter correction, the pipeline was applied to all radiographs to recover quantitative attenuation maps. After subtracting the known attenuation contribution of the metal matrix, spatial maps of the hydrogen attenuation coefficient were obtained for each sample. This data was then used to construct a calibration curve relating hydrogen attenuation to hydrogen concentration and to determine the minimum resolvable hydrogen concentration at the MARS beamline. The resulting dataset provides a pressure-resolved calibration standard for quantitative hydrogen mapping using neutron radiography.

36 MATERIALS SCIENCE↗

Multivariate analysis of remote LIBS spectra using partial least squares, principal component analysis, and related techniques

Quantitative analysis with LIBS traditionally employs calibration curves that are complicated by the chemical matrix effects. These chemical matrix effects influence the LIBS plasma and the ratio of elemental composition to elemental emission line intensity. Consequently, LIBS calibration typically requires a priori knowledge of the unknown, in order for a series of calibration standards similar to the unknown to be employed. In this paper, three new Multivariate Analysis (MV A) techniques are employed to analyze the LIBS spectra of 18 disparate igneous and highly-metamorphosed rock samples. Partial Least Squares (PLS) analysis is used to generate a calibration model from which unknown samples can be analyzed. Principal Components Analysis (PCA) and Soft Independent Modeling of Class Analogy (SIMCA) are employed to generate a model and predict the rock type of the samples. These MV A techniques appear to exploit the matrix effects associated with the chemistries of these 18 samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A method for extracting calibrated volatility information from the FIGAERO-HR-ToF-CIMS and its experimental application

The Filter Inlet for Gases and AEROsols (FIGAERO) is an inlet specificallydesigned to be coupled with the Aerodyne High-Resolution Time-of-FlightChemical Ionization Mass Spectrometer (HR-ToF-CIMS). The FIGAERO-HR-ToF-CIMSprovides simultaneous molecular information relating to both the gas- andparticle-phase samples and has been used to extract vapour pressures (VPs) ofthe compounds desorbing from the filter whilst giving quantitativeconcentrations in the particle phase. However, such extraction of vapourpressures of the measured particle-phase components requires use ofappropriate, well-defined, reference compounds. Vapour pressures for thehomologous series of polyethylene glycols (PEG)((H-(O-CH 2 -CH 2 )n-OH) for n=3 to n=8), covering a rangeof vapour pressures (VP) (10 -1 to 10 -7 Pa) that areatmospherically relevant, have been shown to be reproduced well by a range ofdifferent techniques, including Knudsen Effusion Mass Spectrometry (KEMS).This is the first homologous series of compounds for which a number of vapourpressure measurement techniques have been found to be in agreement,indicating the utility as a calibration standard, providing an ideal set ofbenchmark compounds for accurate characterization of the FIGAERO forextracting vapour pressure of measured compounds in chambers and the realatmosphere. To demonstrate this, single-component and mixture vapour pressuremeasurements are made using two FIGAERO-HR-ToF-CIMS instruments based on anew calibration determined from the PEG series. VP values extracted from bothinstruments agree well with those measured by KEMS and reported values fromliterature, validating this approach for extracting VP data from the FIGAERO.This method is then applied to chamber measurements, and the vapour pressuresof known products are estimated.

47 OTHER INSTRUMENTATION↗

The study of C-13(a, n)O-16 reactions in the Majorana Demonstrator calibration data

Neutron captures and delayed decays of reaction products are common sources of backgrounds in ultra-rare event searches. In this work, we studied 13C(a, n)1640 O reactions induced by a-particles emitted within the calibration sources of the Majorana Demonstrator. These sources are thorium-based calibration standards enclosed in carbon-rich materials. The reaction rate was estimated by using the 6129 keV ?-rays emitted from the excited 1643 O states that are populated when the incoming a-particles have enough energy. Thanks to the excellent energy performance of the Demonstrator’s germanium detectors, these characteristic photons can be clearly observed in the calibration data. Facilitated by Geant4 simulations, a comparison between the observed 6129 keV photon rates and predictions by a TALYS-based software was performed. The measurements and predictions were found to be consistent with each other, albeit with large statistical uncertainties. This agreement provides supports for further background predictions for (a, n)-reactions in future double-beta decay search efforts.

6 ≤ A ≤ 19↗

Validating relativistic models of nuclear structure against theoretical, experimental, and observational constraints

Relativistic mean-field models of nuclear structure have been enormously successful at reproducing ground-state properties of finite nuclei throughout the periodic table using a handful of accurately calibrated parameters. In this contribution, we use powerful theoretical, experimental, and observational constraints on the equation of state of asymmetric nuclear matter--not employed in the calibration procedure--to validate two such models: NL3 and FSUGold. It is observed that FSUGold is consistent with all these constraints, except perhaps for a high-density equation of state that appears mildly softer than required by astronomical observations. It is argued that incorporating such constraints goes a long way in removing much of the ambiguity left over from the standard calibrating procedure.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development and Comparison of Purgeable Mercury Values in SRR Samples Measured by SRNL and Eurofins FGS

Savannah River Remediation (SRR) requested the development of mercury speciation capabilities at the Savannah River National Laboratory (SRNL) to support the Liquid Waste Operations at SRS. As part of that method development, SRR requested that SRNL Analytical Development (AD) compare their results with those obtained from their outside contract laboratory, Eurofins Frontier Global Sciences (FGS). This document reports on this method development work as well as the comparative analyses conducted between the two laboratories. Development, optimization, and validation were undertaken at SRNL to produce a method for the species-specific analysis of dissolved gaseous mercury (DGM) in samples from SRR. It was determined that DGM present in SRR samples represented a combination of various soluble and volatile mercury species- and is thus referred to in this document as purgeable mercury. A method has been developed and analytically validated for the analysis of purgeable mercury in caustic nuclear waste. Using multivariate optimization method, purge flow rate was determined to be highly correlated with increased response (p=0.023). Total recovery of spiked purgeable mercury from deionized water was 99.4 ±10.6% and 91.6 ±14.9% from spiked high-activity tank waste samples. Calibration, by external calibration and standard addition calibration, maintained a mean accuracy of 101 ±5% and 99.9 ±1.7%, respectively. This method represents a decrease in sample handling and processing over currently standard methods and represents a more amenable method for purgeable mercury analysis in liquid nuclear waste.1 An interlaboratory comparison was performed between SRNL and Eurofins FGS in the co-analysis of three quarterly Tank 50 samples. Two samples demonstrated no statistically significant difference (p=0.271, p=0.0811), with one sample biased 30% low to a statistically significant degree (p=0.0432). Large mean uncertainty was present in the results reported by both laboratories (±15% and 40% from SRNL and Eurofins), with no significant difference observed in uncertainty (p=0.934). Across all co-analyzed samples, no significantly difference was observed in precision (p=0.205) or reported values (p=0.352) between SRNL and Eurofins. These results indicate that SRNL-AD may provide data to the customer of statistically similar quality.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Precision Spectrophotometric Calibration System for Dark Energy Instruments

For this research we build a precision calibration system and carried out measurements to demonstrate the precision that can be achieved with a high precision spectrometric calibration system. It was shown that the system is capable of providing a complete spectrophotometric calibration at the sub-pixel level. The calibration system uses a fast, high precision monochromator that can quickly and efficiently scan over an instrument’s entire spectral range with a spectral line width of less than 0.01 nm corresponding to a fraction of a pixel on the CCD. The system was extensively evaluated in the laboratory. Our research showed that a complete spectrophotometric calibration standard for spectroscopic survey instruments such as DESI is possible. The monochromator precision and repeatability to a small fraction of the DESI spectrograph LSF was demonstrated with re-initialization on every scan and thermal drift compensation by locking to multiple external line sources. A projector system that mimics telescope aperture for point source at infinity was demonstrated.

79 ASTRONOMY AND ASTROPHYSICS↗

Chemometrics and Experimental Design for the Quantification of Nitrate Salts in Nitric Acid: Near-Infrared Spectroscopy Absorption Analysis

Implementing remote, real-time spectroscopic monitoring of radiochemical processing streams in hot cell environments requires efficiency and simplicity. The success of optical spectroscopy for the quantification of species in chemical systems highly depends on representative training sets and suitable validation sets. Selecting a training set (i.e., calibration standards) to build multivariate regression models is both time- and resource-consuming using standard one-factor-at-a-time approaches. This study describes the use of experimental design to generate spectral training sets and a validation set for the quantification of sodium nitrate (0–1 M) and nitric acid (0.1–10 M) using the near-infrared water band centered at 1440 nm. Partial least squares regression models were built from training sets generated by both D- and I-optimal experimental designs and a one-factor-at-a-time approach. The prediction performance of each model was evaluated by comparing the bias and standard error of prediction for statistical significance. D- and I-optimal designs reduced the number of samples required to build regression models compared with one-factor-at-a-time while also improving performance. Models must be confirmed against a validation sample set when minimizing the number of samples in the training set. The D-optimal design performed the best when considering both performance and efficiency by improving predictive capability and reducing number of samples in the training set by 64% compared with the one-factor-at-a-time approach. The experimental design approach objectively selects calibration and validation spectral data sets based on statistical criterion to optimize performance and minimize resources.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Calcium fluoride as a dominating matrix for quantitative analysis by laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS): A feasibility study

Here, calcium fluoride formed by the reaction between ammonium bifluoride and calcium chloride was investigated as a dominating matrix for quantitative analysis by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). Transformation from a solid sample to the calcium fluoride-based matrix permitted quantitative analysis based on calibration standards made from elemental standards. A low abundance stable calcium isotope, i.e. 44 Ca + , was monitored as the internal standard for quantitative analysis by LA-ICP-MS. Correlation coefficient factors for multiple elements were obtained with values over 0.999. The results for multiple elements in a certified reference material of soil (NIST SRM 2710a) agreed with the certified values in the range of expanded uncertainty, indicating the present method was valid for quantitation of elements in solid samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis and imaging of boron distribution in maize by quantitative neutron capture radiography

Quantitative neutron capture radiography (QNCR) of 10 B found in pre-dried maize samples has been conducted. Calibration standards constructed from filter paper mimicked plant tissues to reduce confounding matrix effects. A mathematical track elimination method improves the LOD as well as the visual contrast image at low boron concentration levels. The LOD for total boron is 1.7 µg/g in a 4 mm 2 region of interest (ROI). The w(B) in five individual maize tassel meristems has been determined to be 14.9 µg/g – 21.2 µg/g.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗