Defining the Difference Between Laboratory and Field-Generated Foamed Cement

Foamed cement has been used extensively across a variety of applications for oil and gas well cementing, including deepwater riserless cementing, low fracture gradient cementing, horizontal well cementing, steam injection well cementing, and high-pressure/high-temperature (HP/HT) cementing. When using foamed cement, laboratory testing is used to estimate the performance characteristics of foamed cement slurries that are designed for well applications. It is well known that significant differences exist between the methods used to generate foamed cement in the laboratory and those used to generate foamed cement for field applications. The implications of these differences on foamed slurry characteristics (e.g., bubble size distribution) and performance properties (e.g., stability, permeability, mechanical properties) has not been well analyzed or well understood. This paper documents a project that was undertaken through a joint effort between API Sub-Committee 10 and the National Energy Technology Laboratory (NETL) to examine the differences between foamed slurries generated with laboratory equipment and field foamed cementing equipment. Methods for generating and capturing foamed cement samples using field equipment are discussed, as well as analytical methods for evaluating the characteristics of foamed cements. References to the resulting data are provided. Finally, conclusions and recommendations are presented that were developed during the course of the project.

02 PETROLEUM↗

Investigation of Possible Wellbore Cement Failures During Hydraulic Fracturing Operations

We model and assess the possibility of shear failure, using the Mohr-Coulomb model ? along the vertical well by employing a rigorous coupled flow-geomechanic analysis. To this end, we vary the values of cohesion between the well casing and the surrounding cement to representing different quality levels of the cementing operation (low cohesion corresponds to low-quality cement and/or incomplete cementing). The simulation results show that there is very little fracturing when the cement is of high quality.. Conversely, incomplete cementing and/or weak cement can causes significant shear failure and the evolution of long fractures/cracks along the vertical well. Specifically, low cohesion between the well and cemented areas can cause significant shear failure along the well, but the same cohesion as the cemented zone does not cause shear failure. When the hydraulic fracturing pressure is high, low cohesion of the cement can causes fast propagation of shear failure and of the resulting fracture/crack, but a high-quality cement with no weak zones exhibits limited shear failure that is concentrated near the bottom of the vertical part of the well. Thus, high-quality cement and complete cementing along the vertical well appears to be the strongest protection against shear failure of the wellbore cement and, consequently, against contamination hazards to drinking water aquifers during hydraulic fracturing operations.

02 PETROLEUM↗

Cementation of Nuclear Wastes: From Past to Future in a Sustainable Approach - 18266

Cementation of nuclear wastes is a widespread technology due to several factors such as excellent feedback from past experience, simplicity of implementation and versatility. Indeed, as nuclear wastes come in many physical states (bulk wastes, powders, sludges), cementation is the immobilisation process that can easily accommodate this large range of wastes provided the appropriate mixing technology is used: heterogenous cementation (grouting of bulky wastes) or homogenous cementation (intermixing process between the powder or the sludge and the cementitious material). However, nuclear wastes equally present an important chemical variability. This is especially true as New Areva's range of nuclear activities covers the entire fuel cycle: mining, conversion, enrichment and recycling and dismantling and decommissioning. The chemical interactions between the waste and the cement matrix are carefully studied by New Areva's R and D teams in order to provide comprehensive solutions by developing cement formulations which are adapted to wastes characteristics. The aim of the studies is to obtain cement waste-forms that meet the waste acceptance criteria, the final product being thus in perfect adequacy with the disposal requirements. For over 30 years New Areva has been developing cement formulations adapted to the physical and chemical specificities of the wastes accounting for constrains imposed by waste characteristics. The overall approach includes the definition of the appropriate cement composition at laboratory scale, engineering design, equipment manufacturing, testing and commissioning of the cementation facilities. With this strong technical background, a specific methodology has been developed by New Areva teams in order to allow a rapid screening of possible solutions for a given waste (in terms of cement chemistry adapted to the waste) in a learn-fast approach that is based on theoretical analysis and small-scale tests. The methodology was applied for wastes presenting a complex nature (such as reactive metals, ion exchange resins, oils and solvents, mercury, etc), known to interact with Portland cement from a chemical point of view and leading to durability issues of the wasteform (swelling, strength reduction, leaching) and thus reducing the final waste loading. Once the screening process is over, the main drivers for choosing the most appropriate solution to be further developed at pilot scale are: reducing the overall volume and the impact of the final waste package, ensure the waste package performance as defined by the disposal requirements and control the long-term behaviour in final disposal. Moreover, a modelling approach is addressed, aiming to develop a thermo-chemo-mechanical (THM) concrete models that are able to predict the behaviour of the structure (waste form) in time. The aim of the present paper is to describe the main principles within the developed methodology and illustrate it by using a few specific examples. Several distinct cement formulations are developed for complex wastes, limiting the chemical interaction between the cement matrix and the given wastes, obtaining better waste loadings and better overall durability behaviour which facilitates long term behaviour demonstration. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of an Advanced Finite Element Model and Parametric Study to Evaluate Cement Sheath Barrier

Cement failure is known as one of the major causes for loss of well control events. Cement design is considered as one of the top technological knowledge gaps in high-pressure high-temperature oil and gas exploration. The primary objective of this paper is to perform a parametric analysis and identify critical parameters affecting the mechanical integrity of the set cement sheath. To achieve the objective, three-dimensional finite element models consisting of concentric casings and annular cement sheath were created. The finite element model was validated by analytical calculations. Performance of cement sheath was assessed by analyzing radial, hoop, and maximum shear stresses at different loading conditions. A parametric study was conducted by individually varying influencing factors such as cement material properties, sheath dimensions, and wellbore pressure loads. Values of all parameters were normalized and represented on the same plot against mechanical stresses. Such response curves can be used to estimate whether cement will structurally fail because of various operational loads or material aging. The plot can also be utilized to rank various factors in terms of influence on cement’s performance. Sensitivity response reveals that wellbore pressure, cement material properties, and annulus pressure are major parameters influencing mechanical stresses in neat class G cement. The order of importance depends on the type of stress. Results indicate interfacial bond failure and radial cracking to be the more likely modes of failure for class G cement. Cement response curves can help design engineers and regulators alike in quickly evaluating short-term or long-term fitness-for-service of cement sheath from the perspective of structural integrity. Industry standards and guidelines can be improved by adding performance curves for standard cement recipes.

Energy & Fuels↗

Experimental Evaluation of Geopolymer, Nano-Modified, and Neat Class H Cement by Using Diametrically Compressive Tests

Abstract Cement is the prime barrier material to maintain zonal isolation during wellbore life-cycle. Different types of the cement have different performances on sealability. The primary objective of this study is evaluation of three types of cement systems, neat Class H, nano-synthetic graphite, and rock-based geopolymer cements, on interfacial bond integrity. Diametrical compressive tests are used on casing–cement–formation systems. Cement performances are tested in a conventional configuration (Berea Sandstone). A universal testing system is utilized to analyze the relationship applied load–axial strain and the digital image correlation (DIC) technique is used to generate the strain field maps. Based on the relationship and DIC results, bond strengths in different cement systems are evaluated. Additionally, microscope images provide insight explanations of the bond from micro-view. Based on the experimental results, failures of all cases initiate and propagate from the casing–cement interface. Then, radial cracks develop through the formation. This is because the mechanical interlocking bonds are formed only at the cement–sandstone interface to enhance the bond strength. The comparison of geopolymer and nano-modified cements with the conventional cement (neat Class H) shows that the unconventional cements have a lower maximum load and higher axial strain before failure of the samples. It indicates that both the two kinds of cements are more ductile than conventional cement and can support more deformation before the initiation of cracks.

Energy & Fuels↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Alternative Fuel for Portland Cement Processing

The production of cement involves a combination of numerous raw materials, strictly monitored system processes, and temperatures on the order of 1500 °C. Immense quantities of fuel are required for the production of cement. Traditionally, energy from fossil fuels was solely relied upon for the production of cement. The overarching project objective is to evaluate the use of alternative fuels to lessen the dependence on non-renewable resources to produce portland cement. The key objective of using alternative fuels is to continue to produce high-quality cement while decreasing the use of non-renewable fuels and minimizing the impact on the environment. Burn characteristics and thermodynamic parameters were evaluated with a laboratory burn simulator under conditions that mimic those in the preheater where the fuels are brought into a cement plant. A drop-tube furnace and visualization method were developed that show potential for evaluating time- and space-resolved temperature distributions for fuel solid particles and liquid droplets undergoing combustion in various combustion atmospheres. Downdraft gasification has been explored as a means to extract chemical energy from poultry litter while limiting the throughput of potentially deleterious components with regards to use in firing a cement kiln. Results have shown that the clinkering is temperature independent, at least within the controllable temperature range. Limestone also had only a slight effect on the fusion when used to coat the pellets. However, limestone addition did display some promise in regards to chlorine capture, as ash analyses showed chlorine concentrations of more than four times greater in the limestone infused ash as compared to raw poultry litter. A reliable and convenient sampling procedure was developed to estimate the combustion quality of broiler litter that is the best compromise between convenience and reliability by means of statistical analysis. Multi-day trial burns were conducted at a full-scale cement plant with alternative fuels to examine their compatibility with the cement production process. Construction and demolition waste, woodchips, and soybean seeds were used as alternative fuels at a full-scale cement production facility. These fuels were co-fired with coal and waste plastics. The alternative fuels used in this trial accounted for 5 to 16 % of the total energy consumed during these burns. The overall performance of the portland cement produced during the various trial burns performed for practical purposes very similar to the cement produced during the control burn. The cement plant was successful in implementing alternative fuels to produce a consistent, high-quality product that increased cement performance while reducing the environmental footprint of the plant. The utilization of construction and demolition waste, woodchips and soybean seeds proved to be viable replacements for traditional fuels. The future use of these fuels depends on local availability, associated costs, and compatibility with a facility's production process.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Water absorption and shrinkage behaviour of early-age cement in wellbore annulus

Controlling cement shrinkage in a wellbore is well-known as being important in maintaining its integrity. Although numerous laboratory experiments on the water absorption and shrinkage behaviour of oil well cement have been reported in the past, such behaviour in the wellbore annulus with consideration of pore water migration from the surrounding formation has seldom been examined. In this study, using a cement shrinkage model calibrated against available experimental data, a coupled hydromechanical finite element analysis of a cement-formation model is conducted to simulate the water migration, absorption and shrinkage behaviour of early-age cement placed in the annulus of a wellbore. The objectives of this study are (i) to identify the threshold permeability value of the formation above which there is no longer a bottleneck for pore water to flow into the cement and (ii) to estimate a reasonable range of cement bulk shrinkage volume in wellbore annulus geometry. Results show that the threshold permeability of the formation would be around 0.1 mD for three different types of cement examined in this study: Class G cement, rapid setting (RS) cement and Schlumberger optimized particle size distribution (OPSD) technology cement. The bulk shrinkage volume varies from 0.01% to 2.4% depending on cement type and formation permeability (1 mD to 0.1 μD). Finally, the proposed methodology facilitates the simulation of water migration/absorption and shrinkage behaviour of well cement in different formations.

02 PETROLEUM↗

Imaging Wellbore Cement Degradation by Carbon Dioxide under Geologic Sequestration Conditions Using X-ray Computed Microtomography

ABSTRACT: X-ray microtomography (XMT), a nondestructive three-dimensional imaging technique, was applied to demonstrate its capability to visualize the mineralogical alteration and microstructure changes in hydrated Portland cement exposed to carbon dioxide under geologic sequestration conditions. Steel coupons and basalt fragments were added to the cement paste in order to simulate cement-steel and cement-rock interfaces. XMT image analysis showed the changes of material density and porosity in the degradation front (density: 1.98 g/cm3, porosity: 40%) and the carbonated zone (density: 2.27 g/cm3, porosity: 23%) after reaction with CO2- saturated water for 5 months compared to unaltered cement (density: 2.15 g/cm3, porosity: 30%). Three-dimensional XMT imaging was capable of displaying spatially heterogeneous alteration in cement pores, calcium carbonate precipitation in cement cracks, and preferential cement alteration along the cement-steel and cement-rock interfaces. This result also indicates that the interface between cement and host rock or steel casing is likely more vulnerable to a CO2 attack than the cement matrix in a wellbore environment. It is shown here that XMT imaging can potentially provide a new insight into the physical and chemical degradation of wellbore cement by CO2 leakage.

Imaging Wellbore Cement Degradation by Carbon Diox↗

On the Flow of a Cement Suspension: The Effects of Nano-Silica and Fly Ash Particles

Additives such as nano-silica and fly ash are widely used in cement and concrete materials to improve the rheology of fresh cement and concrete and the performance of hardened materials and increase the sustainability of the cement and concrete industry by reducing the usage of Portland cement. Therefore, it is important to study the effect of these additives on the rheological behavior of fresh cement. In this paper, we study the pulsating Poiseuille flow of fresh cement in a horizontal pipe by considering two different additives and when they are combined (nano-silica, fly ash, combined nano-silica, and fly ash). To model the fresh cement suspension, we used a modified form of the power-law model to demonstrate the dependency of the cement viscosity on the shear rate and volume fraction of cement and the additive particles. The convection–diffusion equation was used to solve for the volume fraction. After solving the equations in the dimensionless forms, we conducted a parametric study to analyze the effects of nano-silica, fly ash, and combined nano-silica and fly ash additives on the velocity and volume fraction profiles of the cement suspension. According to the parametric study presented here, larger nano-silica content results in lower centerline velocity of the cement suspension and larger non-uniformity of the volume fraction. Compared to nano-silica, fly ash exhibits an opposite effect on the velocity. Larger fly ash content results in higher centerline velocity, while the effect of the fly ash on the volume fraction is not obvious. For cement suspension containing combined nano-silica and fly ash additives, nano-silica plays a dominant role in the flow behavior of the suspension. The findings of the study can help the design and operation of the pulsating flow of fresh cement mortars and concrete in the 3D printing industry.

36 MATERIALS SCIENCE↗

Portland cement paste behaviour under gamma radiation field in geological repository - 15272

The Radioactive Waste Management Laboratory at the Nuclear and Energy Research Institute in Sao Paulo, Brazil (IPEN-CNEN-SP), is developing the concept of a repository for disposition of disused sealed radioactive sources in a deep borehole in which cement paste is intended to be used as a backfill between the steel casing and the geological formation around the borehole. The cement paste is intended to function as structural material, a blockage against the transport of water between the different strata of the geological setting, and as an additional barrier against the migration of radionuclides. The assessment of the cement paste behaviour in long term is necessary to increase the confidence that the material will perform as required during the service life of the facility. Under radiation, pore water present in cement paste suffers radiolysis and some products can be highly reactive, as electrons and hydroxyl radicals and hydrogen peroxide. These radiolysis products will interact with cement paste and its hydration products, forming a wide range of compounds. Previous work focused on assessing the synergic effects of radiation and environmental conditions, like higher temperature and aggressive groundwater chemicals, on cement paste. Examination of samples detected small differences in mineralogy and microstructure. However, the radiation dose to which samples were exposed (400 kGy) was only a fraction of the expected accumulated dose in cement paste until complete decay of some sealed sources in the repository. Therefore, several thousand kilo-grays must be tested the possibility of radiation to alter cement mineralogy and, as a consequence, its durability The objective of this research is to evaluate the changes in mineralogy and microstructure of irradiated cement paste specimens, in an attempt to establish a relationship between irradiation and durability. Cubic Portland cement specimens were casted and exposed to the gamma radiation of a 60 Co multipurpose irradiator, at IPEN-CNEN/SP. The effects of doses between 1000 kGy and 4000 kGy are evaluated by X-Ray Diffraction, Scanning Electron Microscopy, X-ray micro tomography, neutrongraphy and neutron scattering. This report presents the changes in cement paste mineralogy when samples are examined by XRD. Results indicate that durability can be affected because of the observed changes. Results are expected to indicate the induced changes in cement paste under high radiation doses and to provide hints on its behaviour in the long-term and service-life. The results can be used in safety analysis for deep geological repositories that use cement based materials as engineered barriers. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental validation of multiphysics model simulations of the thermal response of a cement clinker rotary kiln at laboratory scale

Abstract An increasing demand for buildings, transportation systems and civil infrastructure development has driven expansion of cement consumption world‐wide, producing a significant increase in related global energy demand. With approximately 7% of the world‐wide industrial energy consumption (10.7 exajoules [EJ]), the cement industry is the third most energy intensive industrial processes and a key component for concrete, the most consumed composite material in the global construction industry. In cement manufacturing, the cement kiln accounts for most of the energy consumption in the production process. As the heart of a cement plant, the cement kiln is where the kiln feed primarily containing calcium oxide (CaO), silica (SiO 2 ), alumina (Al 2 O 3 ), and iron (Fe 2 O 3 ) are thermally and chemically transformed into clinker minerals. The presented work developed a multiphysics model, designed and built a laboratory‐scale rotary cement clinker kiln, and produced cement clinker at laboratory‐scale. The model was developed to study the interaction between the various thermal, fluid dynamic and chemical interactions involved in the sintering process used to form Portland cement clinker in an effort to reduce energy use. The analytical model was validated through experimental testing using a unique laboratory‐scale rotary cement kiln developed during the investigation. Also demonstrated was the feasibility of producing clinker at laboratory scale. This modeling and lab scale tests were designed to better understand the clinker sintering process so that operational and quality decisions can be made to optimize energy consumption without compromising cement clinker quality. The computational fluid dynamics modeling was developed in COMSOL Multiphysics 6.0. The characteristics of the combustion fluid flow, concentration of species, temperature and heat transfer were studied for a turbulent flow of methane (CH 4 ) gas and oxygen (O 2 ). Theory suggests that heat transfer impacts the cement production process but the multiphysics model more accurately describes the convection, conduction, and radiant heat transfer in the kilning process and thus allows for a better understanding of the energy exchange driving the chemical reactions that produce Portland cement. Clinker minerals were formed because of appropriate burning conditions implemented during experimental model validation.

Tabares, Juan David↗

Effect of bioglass 45S5 addition on properties, microstructure and cellular response of tetracalcium phosphate/monetite cements

Tetracalcium phosphate/nanomonetite (TTCPMH) cement composites with 7.5 and 15 wt% addition of melt-derived 45S5 bioactive glass were prepared by mechanical homogenization of powder components and 2% NaH{sub 2}PO{sub 4} solution was used as a hardening liquid. The properties of composites with the acidic (Ca/P ratio equal 1.5) or basic (Ca/P ratio equal 1.67) TTCPMH component were compared. Addition of glass component caused rapid rise in pH of composites up to 10. In microstructure of basic cement composite, the large bioglass particles weakly bounded to surrounding cement matrix were found contrary to a more compact microstructure of acidic cement composites with the high number of spherical silica particles. Both the significant refinement of hydroxyapatite particles and the change to needle-like morphology with rise in the content of bioglass were identified in hydroxyapatite coatings created during soaking of composites in phosphate buffered saline. In acidic cement mixtures, the increase of compressive strength with an amount of bioglass was found whereas the opposite tendency was revealed in the case of basic cement mixtures. The higher concentrations of ions were verified in solutions after immersion of acidic cement composites. The severe cytotoxicity of extracts and composite cement substrates containing 15 wt% of bioglass demonstrated adverse effects of both the ionic concentrations and unappropriate surface texture on proliferation of mesenchymal stem cells. The enhanced ALP activities of cells cultured on composite cements confirmed the positive effect of bioactive glass addition on differentiation of mesenchymal stem cells. - Highlights: • Novel B45S5 bioglass/tetracalcium phosphate/nanomonetite cement composites • Cement basicity negatively affected their microstructure. • Acid composite cements had higher compressive strengths than basic composites. • Fast differentiation of MSC to osteoblast line on composite with 7.5 wt% of bioglass • Severe cytotoxicity of 24 h extracts from composites with 15 wt% of bioglass.

36 MATERIALS SCIENCE↗

Self-Repairing Polymer-Modified Cements for High Temperature Geothermal and Fossil Energy Applications

In this work five novel polymer-cement composite formulations were prepared and evaluated as potential cementitious material alternatives to conventional wellbore cement. These cement composites were cured at 200 °C and their mechanical properties, including compressive strength, Young modulus, shear bond strength to steel casing, and self-healing and re-adhering (to steel) capability. Thermal stability was also evaluated by curing these cement materials at 200 °C for up to one month followed by determining their mineralogy and chemical composition by X-ray diffraction spectroscopy, 13C NMR, and total organic carbon. Permeability analysis was performed before and after healing a longitudinal fracture on unmodified cements and polymer-cement composites with the later showing lower (2nd/1st) permeability ratios with respect to base cements. Furthermore, a reduction in permeability of up to 80X on average with respect to their unmodified (base) cement, was observed in two polymer-cement formulations suggesting that the introduction of these polymers bring about self-healing capability. Two of the best performing polymer-cement composites were exposed to 30-day curing period at 200 °C showing that their self-healing capability is maintained. The composite stability is associated to the fact that the polymer material is stable as demonstrated by total organic carbon and NMR spectroscopy. These advanced polymer-cement composites with higher ductility and self-healing capability could be used as alternative wellbore cement materials for geothermal and fossil energy applications.

Rod, Kenton A.↗

Chemo‐mechanical Alterations Induced From CO 2 Injection in Carbonate‐Cemented Sandstone: An Experimental Study at 71 °C and 29 MPa

Abstract Carbon capture, utilization, and storage may lead to mechanical degradation of the subsurface reservoir from fluid‐rock interaction, which could lead to wellbore instability or reservoir compaction. To better understand potential relationship between mechanical degradation with various carbonate cement textures and compositions in sandstone reservoirs, six flow‐through experiments were conducted. Formation water (TDS = 5,390 mg/L) enriched with CO 2 flowed through two types of Pennsylvanian Morrow B Sandstone: an ankerite‐siderite‐cemented sandstone (disseminated cement texture) and a calcite‐cemented sandstone (poikilotopic cement texture). The experiments produced little change in permeability in the ankerite‐siderite‐cemented sandstone, but permeability increased up to more than 1 order of magnitude in the calcite‐cemented sandstone. Ultrasonic measurements and cylinder‐splitting tests (also known as Brazilian tests) suggested negligible mechanical degradation of the ankerite‐siderite‐cemented sandstone. Variable changes, with significant mechanical degradation in the static moduli, were observed in the calcite‐cemented sandstone. Thus, dissolution of the disseminated ankerite‐siderite cement (0.28–0.30%) had minimal impact on modifying the flow network and the mechanical integrity of the sandstone, whereas dissolution of the poikilotopic calcite cement (0.89–1.13%, quantified with fluid chemistry and visualized with X‐ray microcomputed tomography) impacted the mechanical strength of the sandstone by disconnecting framework grains. With the high water‐to‐rock mass ratios (7.3–8.2) and number of pore volumes (147–675) employed in these experiments, potential risks are most relevant to regions near injection wells. Ultimately, the chemo‐mechanical effects induced by CO 2 injection are strongly influenced by the cement texture and composition and the burial history of the reservoir rock.

Wu, Z.↗

Thermal Shock-resistant Cement

We studied the effectiveness of sodium silicate-activated Class F fly ash in improving the thermal shock resistance and in extending the onset of hydration of Secar #80 refractory cement. When the dry mix cement, consisting of Secar #80, Class F fly ash, and sodium silicate, came in contact with water, NaOH derived from the dissolution of sodium silicate preferentially reacted with Class F fly ash, rather than the #80, to dissociate silicate anions from Class F fly ash. Then, these dissociated silicate ions delayed significantly the hydration of #80 possessing a rapid setting behavior. We undertook a multiple heating -water cooling quenching-cycle test to evaluate the cement’s resistance to thermal shock. In one cycle, we heated the 200°C-autoclaved cement at 500°C for 24 hours, and then the heated cement was rapidly immersed in water at 25°C. This cycle was repeated five times. The phase composition of the autoclaved #80/Class F fly ash blend cements comprised four crystalline hydration products, boehmite, katoite, hydrogrossular, and hydroxysodalite, responsible for strengthening cement. After a test of 5- cycle heat-water quenching, we observed three crystalline phase-transformations in this autoclaved cement: boehmite → γ-Al 2 O 3 , katoite → calcite, and hydroxysodalite → carbonated sodalite. Among those, the hydroxysodalite → carbonated sodalite transformation not only played a pivotal role in densifying the cementitious structure and in sustaining the original compressive strength developed after autoclaving, but also offered an improved resistance of the #80 cement to thermal shock. In contrast, autoclaved Class G well cement with and without Class F fly ash and quartz flour failed this cycle test, generating multiple cracks in the cement. The major reason for such impairment was the hydration of lime derived from the dehydroxylation of portlandite formed in the autoclaved cement, causing its volume to expand.

15 GEOTHERMAL ENERGY↗

Development and Advanced Testing of DPC Cement Fillers

The fillers research and development (R&D) program, mostly experimental, is part of a broader R&D program that includes new process modeling and performance assessment of criticality effects and the overall importance of criticality to repository performance (consequence screening). A literature research and consultation effort with experts by Hardin and Brady (2018) identified several potentially effective and workable filler materials including cements (primarily phosphate based), moltenmetal alloys, and low-temperature glasses. Filler attributes were defined, and the preliminary lists were compared qualitatively. Further comparative analysis will be done (e.g., cost estimates) after experimental screening has narrowed the list of alternatives. The research presented here is focused Sandia’s efforts for the development of phosphate-based cement fillers. Molten metal filler research is an ongoing activity at Oak Ridge National Laboratories and is not discussed herein. After the completion of the FY20 research effort the following cement filler compositions were selected for further experimental development work and advanced testing in FY21: 1. Aluminum phosphate cements (APCs); more specifically aluminum oxide / aluminum phosphate (Al 2 O 3 / AlPO 4 ) cements in which Al 2 O 3 serves as the filler material bound by an AlPO 4 binder formed by the reaction of Al 2 O 3 with various phosphate sources; 2. Wollastonite phosphate cements (WPCs), specifically wollastonite and aluminum or calcium aluminum phosphates in which CaSiO 3 serves as the filler material bound by a calcium phosphate that serves as the binder; and 3. Calcium aluminate phosphate cements (CAPCs) specifically grossite (CaAl 4 O 7 ) and hibonite (CaAl 11 O 18 ) fillers bound by an aluminum phosphate that serves as the binder. This effort focused on the optimization and subsequent processing of these three cements to achieve dense and well-consolidated monolithic samples. Upon completion of the FY21 effort the aluminum phosphate cements (APCs) and the calcium aluminate phosphate cements (CAPCs) show the most promise for advanced testing and scale up. We will begin the work in FY22 focused on testing the performance of these two cements in small scale DPCs as well as advanced materials testing to evaluate cement performance under expected radiation doses and representative post-closure geochemical environments.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Geochemical and Geomechanical Effects on Wellbore Cement Fractures

Experimental studies were conducted using batch reactors, X-ray microtomograpy (XMT), and computational fluid dynamics (CFD) simulation to determine changes in cement fracture surfaces, fluid flow pathways, and permeability with geochemical and geomechanical processes. Composite Portland cement-basalt caprock core with artificial fractures was prepared and reacted with CO2-saturated groundwater at 50°C and 10 MPa for 3 to 3.5 months under static conditions to understand the geochemical and geomechanical effects on the integrity of wellbores containing defects. Cement-basalt interface samples were subjected to mechanical stress at 2.7 MPa before the CO2 reaction. XMT provided three-dimensional (3-D) visualization of the opening and interconnection of cement fractures due to mechanical stress. After the CO2 reaction, XMT images revealed that calcium carbonate precipitation occurred extensively within the fractures in the cement matrix, but only partially along fractures located at the cement-basalt interface. The permeability calculated based on CFD simulation was in agreement with the experimentally measured permeability. The experimental results imply that the wellbore cement with fractures is likely to be healed during exposure to CO2-saturated groundwater under static conditions, whereas fractures along the cement-caprock interface are still likely to remain vulnerable to the leakage of CO2. CFD simulation for the flow of different fluids (CO2-saturated brine and supercritical CO2) using a pressure difference of 20 kPa and 200 kPa along ~2 cm-long cement fractures showed that a pressure gradient increase resulted in an increase of CO2 fluids flux by a factor of only ~3-9 because the friction of CO2 fluids on cement fracture surfaces increased with higher flow rate as well. At the same pressure gradient, the simulated flow rate was higher for supercritical CO2 than CO2-saturated brine by a factor of only ~2-3, because the viscosity of supercritical CO2 is much lower than that of CO2-saturated brine. The study suggests that in deep geological reservoirs the geochemical and geomechanical processes have coupled effects on the wellbore cement fracture evolution and fluid flow along the fracture surfaces.

36 MATERIALS SCIENCE↗