Search NASA⌕ Search

SEARCH · Search NASA

Results for “CFM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Moisture-Driven Formation and Growth of Quasi-2-D Organolead Halide Perovskite Crystallites

Ruddlesden–Popper phase quasi-2-D organolead halide perovskites like n-butylammonium methylammonium lead iodide (nBA-MAPI) exhibit improved moisture stability over typical 3-D perovskite materials, making them exciting for use in a variety of applications such as photovoltaic (PV) devices. This improved stability is the result of a unique disproportionation-based degradation mechanism that protects the bulk of the nBA-MAPI from extensive damage through the formation of a protective, low-n surface layer. In addition to this surface layer, nBA-MAPI films also exhibit the dynamic growth of micrometer-scale crystallites and cracks at the surface of the film, unique and potentially important byproducts of quasi-2-D perovskite disproportionation. Here, we present a detailed study of these crystallites using several analytical techniques including photoluminescence spectroscopy (PL), confocal fluorescence microscopy (CFM), atomic force microscopy (AFM) combined with time-of-flight-secondary ion mass spectrometry (ToF-SIMS), and others in an effort to better understand the relationship between material disproportionation and crystallite growth. Our results show that the crystallites form after exposure to humid air and confirm that they are composed of low-n phases of nBA-MAPI. The crystallites are found to extend into the interior of the film and exhibit continued growth while exposed to moisture over 72 h. This growth is accompanied by both a decrease in the bulk 2-D phase and an increase in a 3-D-like phase in the surface PL spectra, indicating that the crystallites are likely a product of moisture-driven disproportionation. Importantly, similar crystallites are also observed to form within model PV devices, indicating that such processes must be accounted for when designing future devices containing materials like nBA-MAPI.

36 MATERIALS SCIENCE↗

Large Area Airborne Contamination Monitoring

Current D&D operations at Hanford have demonstrated a flaw in the current state of the art capability of defining airborne contamination boundaries. Airborne particulate emissions of Pu-239 from CM2H operations on the Hanford Pu Finishing Plant were detected well beyond areas controlled for airborne plutonium, putting numerous workers at risk for radiological assimilations. Forty-two Hanford workers had positive bioassay results for plutonium uptake. Work areas determined to be free of airborne contamination as measured by state-of-the-art continuous alpha monitoring (CAM) systems were later discovered not to be. Airborne contamination was scattered to a such degree that CAM systems were surveying insufficient volumes of air to accurately predict where respiratory protection was required. A $\$ 19,000$ state of the art portable CAM system used at both Hanford and at SRS screens air for alpha activity at the rate of 1 CFM. This research project will explore the feasibility of using commercially available air purifying systems to screen significantly larger volumes of air for airborne actinide contamination. Commercial household HEPA based air purifying units screen large volumes of air, a simple $\$ 300$ unit being looked at for this study could screen a volume of air that would require over 300 of the $\$ 19,000$ CAMs. The goal of the project was to determine the feasibility of building a detection system capable of screening the air purifiers pre-filters and HEPA filters for any actinide bearing hot particles that have been captured. The simplest technologies available to Field-Radiological-Protection personnel are hand-held alpha field survey meters. With the size and the corrugated structure of these HEPA filters, hand screening is not practical. This project researched alternatives capable of automating this function. Two potential technologies were examined. One technology evaluated was the measurement of xray emissions from the actinides, taking advantage of the higher emission rates of the L x-rays compared to the gamma emissions of isotopes such as Pu-238 or Pu-239. High resolution to low resolution systems were evaluated. Branching ratio data on the actinides in the literature is incomplete, and a study was initiated to measure branching ratios of the various L emissions of a number of the plutonium isotopes. A Monte Carlo simulation was also run to calculate the effect the attenuating HEPA media would have on x-ray measurements on spectrometers centered in each quadrant above the surface of the HEPA. The second technology evaluated was measuring the light from a scintillating media applied to the surface of the HEPA filter using a ThorLabs Scientific-Grade Digital Camera Model 8051M. A light tight enclosure capable of holding the 2’x2’x1” HEPA filter was fabricated. Numerous scintillation media were evaluated for both the sensitivity and for resolution of measuring alpha activity. Figure 1 shows images of a 4”x4” section of HEPA filter with a 3 x 3 grid of Pu-238 contamination loaded inside the crevices of the HEPA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SR19039 - All Metal Vacuum Scroll Pump Development for Tritium

Currently the Savannah River Site tritium gas processing mission relies on a pumping train combination of a Normetex scroll pump backed by a Metal Bellows MB-601 diaphragm pump. Both of these pumps have wetted components that are "all-metal" so that no polymers or elastomers that can degrade due to tritium gas exposure are exposed to the process fluid. Normetex, the original all-metal vacuum scroll pump manufacturer, has gone out of business. Another French based company, Eumeca, has "spun off" from the Normetex company and is now producing the original, 9 cfm all metal Normetex vacuum scroll pump. It should be noted that Normetex, now Eumeca, is currently the only supplier of a functional all metal vacuum scroll pump to meet the SRS tritium gas processing requirement.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Research and Development of a Ventilation-Integrated Comfort System

From an indoor air quality perspective, the best residential ventilation strategies include filtering outdoor air and distributing that air to all occupied parts of a home. From an energy standpoint, it is desirable that energy be transferred from the exhaust air to the incoming outdoor air to limit heating and cooling impacts. Heat or energy recovery ventilators (HRVs or ERVs) can provide these functions, but researchers have seen many poor installations related to design, installation, and operation and maintenance. More robust ventilation systems may involve an ERV with a dedicated duct distribution system and controls. Such a duct system can be costly to install, and many builders reduce these costs by connecting an ERV to a central heating and cooling duct system. Although this can sometimes be done effectively, researchers have seen consistent challenges with low, inconsistent, or imbalanced flow rates; high electricity consumption; and—of greatest concern—outdoor air short-circuiting or not being delivered to occupied spaces at all. Most ERVs are designed to operate with their own duct system; they are not designed as an add-on to much larger heating, ventilating, and air-conditioning (HVAC) systems. The ventilation-integrated comfort system (VICS) is expressly designed to integrate with low-capacity, efficient, ducted heating and cooling systems. Overall, the latest VICS prototype consumed 40–75 watts (W), including the air handler power, to deliver 50–120 cfm of whole-dwelling ventilation. The large, cross-flow ERV core performed to match manufacturer values (73% winter sensible effectiveness, 64% summer total effectiveness), but further improvements are possible. The VICS system researched and tested during this project will provide efficient, controllable, balanced energy recovery ventilation that is integrated with heating and cooling systems. The integration reduces space and ductwork needed for separate ventilation systems, and there are no compromises to heating, cooling, or ventilation performance. The integrated nature of the device also reduces risks for improper installation and commissioning. Even when using the air handler blower to distribute outdoor air, the total power consumption is lower than that of most available ERV products in the same airflow range. This system has the potential to offer very high-performance ventilation with much smoother and simpler installation than conventional systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrochemically Regenerated Solvent for Direct Air Capture with Co-generation of Hydrogen at Bench-scale

The goal of this final project report is to summarize the work conducted on project DE-FE0032125. In accordance with the Statement of Project Objectives (SOPO), the University of Kentucky Institute for Decarbonization and Energy Advancement (UK IDEA) (Recipient) developed an intensified process to capture CO 2 from ambient conditions (415 ppm CO 2 ). The process combines low-temperature solvent-aided membrane capture with electrochemically-mediated solvent regeneration to simultaneously capture ambient CO 2 while regenerating the solvent. The technology employs only two primary units, a regenerator and an absorber/contactor, while generating high purity hydrogen as a co-product that can be sold, used for energy storage, or cost-saving depolarization of the direct air capture (DAC) system during the grid peak demand, allowing for flexible operation. Since the technology is powered directly by DC electricity, it can seamlessly tie in with power sources like solar cells without the need for AC/DC converters, therefore allowing for a remote operation to further mitigate greenhouse gas generation toward deploying a negative carbon emissions technology that is completely decoupled from the carbon emissions from the power source for the DAC unit. The completion of the project results in significant progress toward the Department of Energy’s (DOE’s) goal of advancing lab and bench-scale DAC systems to a sufficient maturity level that can justify their continued scale-up through the verification testing of the electrochemically regenerated solvent system for DAC with co-generation of hydrogen at bench-scale. The technology addressed the complexities of incumbent DAC systems by demonstrating at ambient conditions (1) low gas-side pressure-drop facile CO 2 capture via an intensified membrane absorber with in-situ regenerated hydroxide as capture solvent, (2) multi-functional electrochemical regenerator for hydroxide regeneration, CO 2 concentration and hydrogen production at less than 3 V, and (3) stable DAC performance including >90% capture with air influent at the CFM scale. The data from this project enables the completion of Techno-Economic Analysis (TEA) and Life Cycle Assessment (LCA). TEA and LCA demonstrate the potential of the proposed electrochemical solvent-based process to be a viable DAC option. The analysis did not identify any obvious concern for the bench-scale operation and no apparent barriers to implementing UK IDEA carbon capture and solvent regeneration system at a larger scale.

08 HYDROGEN↗

Membrane-based Ionic Liquid Absorption System for Ultra-Efficient Dehumidification and Heating

The project team – comprising the University of Florida (UF), GTI Energy, and Modine Manufacturing – sought to develop a highly efficient heat-powered absorption cycle with combined dehumidification and heat pumping. This DOE-supported project advanced the technology from a TRL of 3 to 6, culminating in the development of a 1,000 CFM system. Key innovations implemented in the system addressed the low efficiency, size, cost, and reliability challenges of conventional absorption cycles. Specifically, the system was enabled by: (1) a semi-open cycle that allowed simultaneous dehumidification and heat recovery, (2) non-crystallizing ionic liquids (ILs) that enabled “double-effect” operation at elevated temperatures without the need for costly control equipment, (3) a compact membrane-based absorber that confined the IL and directly cooled it to achieve low dew points, and (4) a novel, highly integrated desorber–condenser assembly that reduced size, weight, and cost. The technology was developed with commercial HVAC applications in mind, particularly for separate sensible and latent cooling (SSLC), an innovation aimed at achieving independent and more efficient humidity control.

42 ENGINEERING↗

Dual-loop Solvent-based CCS for Net Negative CO 2 Emissions with Lower Cost

This final technical report details the successful design, construction, and operational validation of an innovative dual-loop CO 2 capture technology designed to achieve deep decarbonization (>99%) from Natural Gas Combined Cycle (NGCC) power plants that results in the electricity with carbon intensity of approximate 42 kg CO 2 -eq/MWh, less than the electricity produced by solar PV. The integrated process couples a primary aqueous solvent (in this project, a water lean solvent – WLS) absorption loop for bulk CO 2 removal with a secondary potassium hydroxide (KOH) polishing loop featuring electrochemical regeneration. This architecture leverages the higher exergy efficiency of the primary loop while utilizing the fastest kinetic of the secondary loop to capture dilute residual CO 2 , achieving an overall capture rate of 99.9% and co-producing pure hydrogen after moisture being condensed and dehydrated. Technical feasibility was established through a comprehensive 2,000-hour experimental campaign on a bench-scale fully-integrated unit (using 4” absorber and 4” stripper) with the feeding flue gas flowrate in the range of 8-20 cfm, confirming the attainment of Technology Readiness Level (TRL) 4. The project executed extensive parametric testing followed by 1,000 hours of continuous steady-state testing, demonstrating exceptional process stability with the electrochemical regenerator exhibiting less than a 10% reduction in electrical conductivity over the duration of the campaign. Operational characterization gathering on the bench unit revealed distinct energy profiles for the hybrid system: the primary loop required approximately 280 kJ mol -1 for bulk removal, while the polishing loop required approximately 1,600 kJ mol -1 specifically when reducing dilute CO 2 concentrations from ~740 ppm down to <50 ppm. (Please note those energy values/numbers can only be viewed as relative relationship and should not be extrapolated as absolute values required for CO 2 capture). Furthermore, dynamic testing validated the system’s flexibility for utility applications, demonstrating a rapid process response time of <30 minutes to changes in flue gas flowrate. Emission monitoring confirmed that the dual-loop architecture effectively mitigates solvent losses, utilizing a water wash to remove entrained aerosols to <1 ppm. The Techno-Economic Analysis (TEA) indicates a cost of capture of $\$$59.3/tonne and a Levelized Cost of Electricity (LCOE) of 71.7 $\$$/MWh at the overall capture efficiency of 99.8% of total carbon in the flue gas stream, with sensitivity analysis identifying an economic optimum when the primary loop captures 97% of the total CO 2 . A Life Cycle Assessment (LCA) confirms the technology’s potential for net-negative emissions, determining a Global Warming Potential (GWP) of 52 kg CO 2 -eq/MWh—significantly lower than the baseline—which further decreases to 42 kg CO 2 -eq/MWh when crediting the displacement of conventional hydrogen production.

03 NATURAL GAS↗

Solid metabolic waste transport and stowage investigation

The basic Waste Collection System (WCS) design under consideration utilized air flow to separate the stool from the WCS user and to transport the fecal material to a slinger device for subsequent deposition on a storage bowel. The major parameters governing stool separation and transport were found to be the area of the air inlet orifices, the configuration of the air inlet orifice and the transport air flow. Separation force and transport velocity of the stool were studied. The developed inlet orifice configuration was found to be an effective design for providing fecal separation and transport. Simulated urine tests and female user tests in zero gravity established air flow rates between 0.08 and 0.25 cu sm/min (3 and 9 scfm) as satisfactory for entrapment, containment and transport of urine using an urinal. The investigation of air drying of fecal material as a substitute for vacuum drying in a WCS breadboard system showed that using baseline conditions anticipated for the shuttle cabin ambient atmosphere, flow rates of 0.14 cu sm/min (5 cfm) were adequate for drying and maintaining biological stability of the fecal material.

Burt, R. A.↗

Analysis of simple 2-D and 3-D metal structures subjected to fragment impact

Theoretical methods were developed for predicting the large-deflection elastic-plastic transient structural responses of metal containment or deflector (C/D) structures to cope with rotor burst fragment impact attack. For two-dimensional C/D structures both, finite element and finite difference analysis methods were employed to analyze structural response produced by either prescribed transient loads or fragment impact. For the latter category, two time-wise step-by-step analysis procedures were devised to predict the structural responses resulting from a succession of fragment impacts: the collision force method (CFM) which utilizes an approximate prediction of the force applied to the attacked structure during fragment impact, and the collision imparted velocity method (CIVM) in which the impact-induced velocity increment acquired by a region of the impacted structure near the impact point is computed. The merits and limitations of these approaches are discussed. For the analysis of 3-d responses of C/D structures, only the CIVM approach was investigated.

Witmer, E. A.↗

The reaction Cl + H2CO yields HCl + HCO: Decreased sensitivity of stratospheric ozone to chlorine perturbations

The absolute rate constant for the reaction Cl + H2CO yields HCl + HCO was determined by the flash-photolysis resonance fluorescence method to be 7.5 plus or minus 0.9 (2 sigma) times 10 to the minus 11th power cu cm/molecule sec at 298 K and to have a negligible temperature dependence. This rate which is more than 2000 times faster than the rate of Cl + CH4 indicates that formaldehyde (H2CO) will compete significantly with methane (CH4) for the conversion of active chlorine in the stratosphere to the inactive reservoir HCl. Chlorine will thus be a less efficient destroyer of stratosphere ozone than previously believed. Ambient stratospheric ozone will depend less on the ambient chlorine amount and the predicted response to chlorine perturbations will be lessened. One-dimensional eddy-diffusion photochemical model calculations indicate a factor of 1.1 less sensitivity to chlorine than recently reported. For a steady-state CFM release at 1975 rates (750,000 tons/year) the eventual ozone depletion is now calculated to be 14%.

Stief, L. J.↗

Input sensitivity study of a stratospheric photochemistry model

A general technique for calculating the sensitivities, uncertainties and overall imprecision of a model to a set of input parameters is described and applied to the calculation of CFM (chlorofluoromethane) induced stratospheric ozone depletion. The input data set used is reaction rates and the technique highlights those that most need further study in the laboratory. The convolution of individual uncertainties to obtain an overall imprecision gives good agreement with the results of Monte-Carlo calculations using the same model.

Butler, D. M.↗

Development of materials and process technology for dual alloy disks

Techniques for the preparation of dual alloy disks were developed and evaluated. Four material combinations were evaluated in the form of HIP consolidated and heat treated cylindrical and plate shapes in terms of elevated temperature tensile, stress rupture and low cycle fatigue properties. The process evaluation indicated that the pe-HIP AF-115 rim/loose powder Rene 95 hub combination offered the best overall range of mechanical properties for dual disk applications. The feasibility of this dual alloy concept for the production of more complex components was demonstrated by the scale up fabrication of a prototype CFM-56 disk made from this AF-115/Rene 95 combination. The hub alloy ultimate tensile strength was approximately 92 percent of the program goal of 1520 MPa (220 ksi) at 480 C (900 F) and the rim alloy stress rupture goal of 300 hours at 675 C (1250 F)/925 MPa (134 ksi) was exceeded by 200 hours. The low cycle fatigue properties were equivalent to those exhibited by HIP and heat treated alloys. There was an absence of rupture notch sensitivity in both alloys. The joint tensile properties were approximately 85 percent of the weaker of the two materials (Rene 95) and the stress rupture properties were equivalent to those of the weaker of the two materials (Rene 95).

Marder, J. M.↗

Analysis of upper stratospheric Umkehr ozone profile data for trends and the effects of stratospheric aerosols

The effect of stratospheric aerosols on Umkehr estimates of long-term ozone depletion associated with chlorofluoromethanes (CFMs) is considered in a statistical time series trend analysis. Time series models are estimated using monthly averages of Umkehr measurements made over the last 15 to 20 years. The time series regression models incorporate seasonal, trend and noise factors and an additional factor to account for the effects of atmospheric aerosols on the Umkehr measurements. The analysis indicates a statistically significant relation with atmospheric aerosol transmission in the Umkehr layers and implies that the relation is an important factor in any time series trend analysis of Umkehr data. Taking this relation into account, statistically significant negative trends were found in the Upper Umkehr layers. It is pointed out that upper stratospheric ozone could be sensitive to long-term solar variability as well as other possible influences in addition to CFM-induced effects, and therefore the cause or causes of the estimated trend cannot be unambiguously estimated using current Umkehr data.

Reinsel, G. C.↗

Directivity optimization of a reflector antenna with cluster feeds - A closed-form solution

The directivity of a reflector antenna deteriorates as the feed moves away from the focal point for beam scanning. This deterioration can be substantially reduced if a cluster feed instead of single feed is used to control a beam. A closed-form solution is presented for the cluster excitation to achieve the optimum directivity. For an offset 108 lambda parabolic reflector scanning 10 beamwidths, the optimum directivity achieved by a 19-element (seven-element) cluster is 12 dB (8 dB) higher than that of a single element. Comparison of the optimum-directivity design and the popular conjugate field matching design is made. When the cluster spacing d is greater than 1 lambda, it is found that the optimum directivity is higher than that of conjugate field matching (CFM) scheme by an insignificant amount, although the excitations of two designs can be quite different. For d less than 0.5 lambda, the optimum design may exhibit the supergain phenomenon, namely extremely high directivities achieved by an oscillatory cluster excitation.

Lam, P. T.↗

NASA DC-8 airborne research laboratory

Since the summer of 1987, NASA Ames Research Center has been operating a DC-8 equipped with CFM 56 engines as a flying research laboratory. In this relatively short time, the DC-8, with its tremendous capabilities, has made significant contributions to numerous scientific fields. Capable of staying aloft for over 12 hours, the DC-8 has flown directly over both the North and South Poles, gathering data relating to the ozone hole. Operating from a few thousand feet to over 40,000 feet above sea level the interchangeable payload capability of the DC-8 has made it a versatile scientific tool. The DC-8 also plays a vital role in the development of new satellite-borne sensors as very often those sensors are test-flown on the DC-8 before they are launched into space. The tremendous range and instrument carrying capability make the DC-8 an ideal flying laboratory. A few of the programs the DC-8 has participated in as well as a sampling of the instruments carried are outlined.

Degreef, Leo H.↗

Hydrogen slush production with a large auger

The design and construction of a 178-mm-diameter auger-type hydrogen slush generator are described. A supercritical helium flow loop, which simulates the performance of a helium refrigerator, cools the generator. The coolant temperature varies down to 5 K and the flow varies about the 1.4 L/s (3 cfm) design point. The computer model of the auger-type generator shows that coolant temperature and auger speed have the greatest influence on slush production rate, although coolant flow rate and auger radial clearance are also important.

Daney, D. E.↗

Flight test of an improved solid waste collection system

A system for human waste collection is described and evaluated on the basis of a prototype employed for the shuttle flight STS-35. The manually operated version of the unit is designed to collect, compact, and store human waste and cleaning material in replaceable volumes. The system is presented with illustrations and descriptions of the disposable pads that are used to clean the cylinder and occlusive air valves as well as seal the unit. Temporary retention and waste entrainment are provided by the variable airflow in the manual unit tested. The prototype testing indicates that sufficient airflow is achieved at 45 CFM and that the stowage volume (18.7 cu in.) is adequate for storing human waste with minimal logistical support. Higher compaction pressure and the use of a directed airstream are proposed for improving the packing efficiency of the unit.

Thornton, W.↗

CONE - An STS-based cryogenic fluid management experiment

An overview of the CONE program is presented which includes a definition of the technology addressed by CONE and a baseline experiment set, a description of the experimental and support subsystems, interface requirements between the STS and the experiment carrier (Hitchhiker M), and the reusability and expansion capacity for additional experiment flights. CONE evaluates three primary technologies: the active thermodynamic vent system, the passive thermodynamic vent system, and liquid acquisition device performance. The cryogenic fluid management technology database that the system offers will allow for efficient subcritical cryogenic system designs for operation in a low-gravity environment. This system maximizes the balance between existing component technology and the need for the development of a cryogenic-fluid-management (CFM) test bed to investigate and demonstrate methods of storage and handling arenas.

Bell, R. S.↗