Search NASA⌕ Search

SEARCH · Search NASA

Results for “CHROMATOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Behavior of selenium and arsenic in $\mathrm{HCl}$ and $\mathrm{HNO}$ 3 on $\mathrm{TRU, TEVA, DGA,}$ and $\mathrm{Pb}$ extraction chromatography resins

The uptake behavior of 73 As and 75 Se was studied in HCl and HNO 3 -H 2 O 2 solutions on commercial extraction chromatography resins (TEVA, TRU, DGA, and Pb resin). There was no uptake of 73 As or 75 Se from HNO 3 media. From HCl, there was 75 Se uptake at high concentrations on all the resins and no uptake of 73 As. Separations of 75 Se and 73 As on these resins have high yields and high radiopurity for 73 As, but limited recovery of 75 Se. TRU and TEVA resin may have potential for use in isotope generators as 75 Se can be retained for at least 26 days with repeated elutions.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Purification of legacy Ra-226 from ingrown Pb-210 using cation exchange chromatography

With the growing interest in using radium-226 (Ra-226) as a source material to produce essential radionuclides for targeted alpha therapies, the global demand for Ra-226 has surged, rendering its acquisition difficult. The shortage necessitates the exploration of alternative pathways to obtain this isotope beyond traditional commercial vendors. Legacy radium sources remain widespread due to Ra-226’s historical use but require the removal of ingrown daughter products to obtain a pure Ra-226 product. In conclusion, a straightforward and effective purification method for legacy Ra-226 ampoules has been developed using cation exchange chromatography, enabling the reliable conversion of legacy materials into high-purity Ra-226 solutions.

and nuclear chemistry↗

A statistical analysis of the effects of urease pre-treatment on the measurement of the urinary metabolome by gas chromatography–mass spectrometry

Urease pre-treatment of urine has been utilized since the early 1960s to remove high levels of urea from samples prior to further processing and analysis by gas chromatography-mass spectrometry (GC-MS). Aside from the obvious depletion or elimination of urea, the effect, if any, of urease pre-treatment on the urinary metabolome has not been studied in detail. Here, we report the results of three separate but related experiments that were designed to assess possible indirect effects of urease pre-treatment on the urinary metabolome as measured by GC-MS. In total, 235 GC-MS analyses were performed and over 106 identified and 200 unidentified metabolites were quantified across the three experiments. The results showed that data from urease pre-treated samples 1) had the same or lower coefficients of variance among reproducibly detected metabolites, 2) more accurately reflected quantitative differences and the expected ratios among different urine volumes, and 3) increased the number of metabolite identifications. Altogether, we observed no negative consequences of urease pre-treatment. In contrast, urease pretreatment enhanced the ability to distinguish between volume-based and biological sample types compared to no treatment. Taken together, these results show that urease pretreatment of urine offers multiple beneficial effects that outweigh any artifacts that may be introduced to the data in urinary metabolomics analyses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gas Chromatography-Tandem Mass Spectrometry of Lignin Pyrolyzates with Dopant-Assisted Atmospheric Pressure Chemical Ionization and Molecular Structure Search with CSI:FingerID

Dopant-assisted atmospheric pressure chemical ionization (dAPCI) is a soft ionization method rarely used for gas chromatography-mass spectrometry (GC-MS). The current study combines GC-dAPCI with tandem mass spectrometry (MS/MS) for analysis of a complex mixture such as lignin pyrolysis analysis. To identify the structures of volatile lignin pyrolysis products, collision-induced dissociation (CID) MS/MS using a quadrupole time-of-flight mass spectrometer (QTOFMS) and pseudo MS/MS through in-source collision-induced dissociation (ISCID) using a single stage TOFMS are utilized. To overcome the lack of MS/MS database, Compound Structure Identification (CSI):FingerID is used to interpret CID spectra and predict best matched structures from PubChem library. With this approach, a total of 59 compounds were positively identified in comparison to only 22 in NIST database search of GC-EI-MS dataset. This study demonstrates the effectiveness of GC-dAPCI-MS/MS to overcome the limitations of traditional GC-EI-MS analysis when EI-MS database is not sufficient. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies on the analysis of 25-hydroxyvitamin D{sub 3} by isotope-dilution liquid chromatography–tandem mass spectrometry using enzyme-assisted derivatisation

Highlights: • New method for the analysis of 25-hydroxyvitamin D{sub 3} exploiting Girard P derivatisation. • Method also applicable to vitamin D{sub 3}, 1α,25- and 24,25-dihydroxyvitamin D{sub 3}. • By modification of the method 3-epi-25-hydroxyvitamin D{sub 3} can also be analysed. - Abstract: The total serum concentration of 25-hydroxyvitamins D (25-hydroxyvitamin D{sub 3} and 25-hydroxyvitamin D{sub 2}) is currently used as an indicator of vitamins D status. Vitamins D insufficiency is claimed to be associated with multiple diseases, thus accurate and precise reference methods for the quantification of 25-hydroxyvitamins D are needed. Here we present a novel enzyme-assisted derivatisation method for the analysis of vitamins D metabolites in adult serum utilising 25-[26,26,26,27,27,27-{sup 2}H{sub 6}]hydroxyvitamin D{sub 3} as the internal standard. Extraction of 25-hydroxyvitamins D from serum is performed with acetonitrile, which is shown to be more efficient than ethanol. Cholesterol oxidase is used to oxidize the 3β-hydroxy group in the vitamins D metabolites followed by derivatisation of the newly formed 3-oxo group with Girard P reagent. 17β-Hydroxysteroid dehydrogenase type 10 is shown to oxidize selectively the 3α-hydroxy group in the 3α-hydroxy epimer of 25-hydroxyvitamin D{sub 3}. Quantification is achieved by isotope-dilution liquid chromatography–tandem mass spectrometry. Recovery experiments for 25-hydroxyvitamin D{sub 3} performed on adult human serum give recovery of 102–106%. Furthermore in addition to 25-hydroxyvitamin D{sub 3}, 24,25-dihydroxyvitamin D{sub 3} and other uncharacterised dihydroxy metabolites, were detected in adult human serum.

60 APPLIED LIFE SCIENCES↗

Evaluating size exclusion chromatography for nucleic acid removal in Klebsiella pneumoniae cell surface polysaccharide purification

Cell surface-associated polysaccharides in Klebsiella are major virulence determinants and crucial targets for developing vaccines. Traditionally, the purification of these cell surface polysaccharides from Klebsiella pneumoniae involves a multi-step process comprising phenol extraction, nuclease digestion, ultracentrifugation, and repeated ethanol extractions. In this study, we evaluated size exclusion chromatography for effectively eliminating nucleic acid contamination while purifying high molecular weight cell surface-associated polysaccharides. Post-initial extraction, the nucleic acid content remains significantly elevated, and kinetic analysis reveals that DNase I and RNase A digestion is neither economically viable nor effective for removing these contaminants. Employing an appropriate size exclusion resin removes over 99 % of nucleic acid contamination, as confirmed by nucleic acid content analysis and agarose gel electrophoresis. Purity and structural analysis using 1H 1D-NMR and 2D-NMR demonstrate that the cell surface-associated polysaccharide purified with this study is highly homogeneous and identified as antigenic O-polysaccharide. This approach streamlines the purification process by removing the need for nuclease digestion and additional ethanol precipitation steps.

60 APPLIED LIFE SCIENCES↗

Mechanism of astatine and bismuth sorption on extraction chromatography resins from nitric acid media

Systematic study of astatine (At) sorption on extraction chromatography resins from nitric acid media has been performed at Texas A&M University. This work covers commercially available resins such as LN, TK400, SR, TRU, and UTEVA. Acquiring an understanding of At behavior in up to 4 M HNO 3 solutions is a key step to develop a rapid and reliable system for At separation and purification. The determined distribution coefficients are greater than 20 for all the resins studied, reaching 400 for TRU and UTEVA resins. The sorption uptake decreases in the order: TRU ≳ UTEVA >TK400 ≳ SR >LN. For each resin a thermodynamic model has been developed to suggest a possible mechanism of At sorption and corresponding sorption constants have been estimated. Literature data along with new results on bismuth (Bi) sorption by studied resins in nitric acid media have been reviewed and a mathematical model to describe its behavior has been suggested. A ratio of corresponding fit functions of At and Bi assigned to the same resin and acidity has been used to estimate separation factors of these elements. Furthermore, only the TRU resin is not suitable for efficient At isolation from Bi, while the other four resins demonstrate promising results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Application of ion exchange and extraction chromatography to the separation of actinium from proton-irradiated thorium metal for analytical purposes

We present that actinium-225 (t 1/2 = 9.92 d) is an α-emitting radionuclide with nuclear properties well-suited for use in targeted alpha therapy (TAT), a powerful treatment method for malignant tumors. Actinium-225 can also be utilized as a generator for 213 Bi (t 1/2 45.6 min), which is another valuable candidate for TAT. Actinium-225 can be produced via proton irradiation of thorium metal; however, long-lived 227 Ac (t 1/2 = 21.8 a, 99% β - , 1% α) is co-produced during this process and will impact the quality of the final product. Thus, accurate assays are needed to determine the 225 Ac/ 227 Ac ratio, which is dependent on beam energy, irradiation time and target design. Accurate actinium assays, in turn, require efficient separation of actinium isotopes from both the Th matrix and highly radioactive activation by-products, especially radiolanthanides formed from proton-induced fission. In this study, we introduce a novel, selective chromatographic technique for the recovery and purification of actinium isotopes from irradiated Th matrices. A two-step sequence of cation exchange and extraction chromatography was implemented. Radiolanthanides were quantitatively removed from Ac, and no non-Ac radionuclidic impurities were detected in the final Ac fraction. An 225 Ac spike added prior to separation was recovered at ≥98%, and Ac decontamination from Th was found to be ≥10 6 . Finally, the purified actinium fraction allowed for highly accurate 227 Ac determination at analytical scales, i.e., at 227 Ac activities of 1–100 kBq (27 nCi to 2.7 μCi).

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Separation of 44 Ti from proton irradiated scandium by using solid-phase extraction chromatography and design of 44 Ti/ 44 Sc generator system

Scandium-44 g (half-life 3.97 h) shows promise for positron emission tomography (PET) imaging of longer biological processes than that of the current gold standard, 18 F, due to its favorable decay parameters. One source of 44 gSc is the long-lived parent nuclide 44 Ti (half-life 60.0 a). A 44 Ti/ 44 gSc generator would have the ability to provide radionuclidically pure 44 gSc on a daily basis. The production of 44 Ti via the 45 Sc(p,2n) reaction requires high proton beam currents and long irradiation times. Recovery and purification of no-carrier added (nca) 44 Ti from scandium metal targets involves complex separation chemistry. In this study, separation systems based on solid phase extraction chromatography were investigated, including branched diglycolamide (BDGA) resin and hydroxamate based ZR resin. Lastly, results indicate that ZR resin in HCl media represents an effective 44 Ti/ 44 gSc separation system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Anion exchange and extraction chromatography tandem column isolation of zirconium-89 ( 89 Zr) from cyclotron bombarded targets using an automated fluidic platform

The long-lived positron emitter 89 Zr is a highly promising nuclide employed in diagnostic Positron Emission Tomography (PET) imaging. Methods of radiochemical processing to obtain 89 Zr for clinical use are traditionally performed with a single hydroxamate resin column. In this work, we present a tandem column purification method for the preparation of high-purity 89 Zr from cyclotron bombarded Y metal foils. The primary column is a macroporous, strongly basic anion exchange resin on styrene divinylbenzene co-polymer. The secondary microcolumn, with an internal volume of 33 µL, is packed with an extraction chromatography resin (ExCR) loaded with HDEHP. A condition of “inverted selectivity” is presented, wherein the 89 Zr elution from the primary column is synonymous with the load condition on the secondary column. The ability to transfer 89 Zr from one column to the next allows two sequential column clean-up methods to be performed prior to the final elution of the 89 Zr product. This approach assures delivery of very high purity 89 Zr . The tandem column purification process has been implemented into a prototype automated fluidic system. Optimization of the method is presented, followed by evaluation of the process using seven cyclotron bombarded Y metal foil targets. Once optimized, we found that 93.7±2.3% of the 89 Zr present in the foils was recovered in the secondary column elution fraction (0.8 M oxalic acid). Radiochromatograms of the product elution peaks enabled determination of full width at half-maximum (FWHM) and 89 Zr collection yields as a function of volume. Because of the small size of the secondary microcolumn, a 89 Zr product volume of ~0.28 mL is reported, which provides a substantially increased nuclide concentration over traditional methods. Finally, we evaluated the transchelation of the resulting 89 Zr oxalate product to deferoxamine mesylate (DFOM) salt. We observed effective specific activities (ESA) and bindable metals concentrations ([M B ]) that exceed those reported by the traditional single hydroxamate column method.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Rare earth element separations by high-speed counter-current chromatography

We report that following the initial development of High-Speed Counter-Current Chromatography (HSCCC) in the 1960s, several studies have explored its applicability in the separation of rare earth elements (REEs). More recently, however, HSCCC publications have transitioned towards the separation of natural products or pharmaceuticals, leaving the application for REEs largely unexplored from a practical standpoint. Herein, we expand upon prior work in this field by evaluating the suitability of HSCCC to separation of a subset of non-radioactive REEs (Nd, Sm, Eu, Tb, and Y) at 10 -4 mol levels using di-(2-ethylhexyl)phosphoric acid (HDEHP) in n-heptane as the stationary phase and hydrochloric acid as the mobile phase. First, the effect of flow rate on the stationary phase volume retention ratio and resolution of Nd/Sm/Eu subgroup was evaluated followed by optimization of step-gradient elution profiles resulting in additional recovery of Tb and Y within a seven-hour window. The five REEs were separated at the baseline resolution level or above. Elution profiles obtained from multiple runs across two independently operated columns and across independent runs were cross analyzed. Reproducibility in elution profiles point to future applications in radioelement separation chemistry, where both chemical and radiochemical purity are of importance.

47 OTHER INSTRUMENTATION↗

The use of gas chromatography – high resolution mass spectrometry for suspect screening and non-targeted analysis of per- and polyfluoroalkyl substances

This study is a workflow development for the analysis, identification, and categorization of per- and polyfluoroalkyl substances (PFAS) using gas chromatography-high resolution mass spectrometry (GC-HRMS) with non-targeted analysis (NTA) and suspect screening techniques. The behavior of various PFAS in a GC-HRMS was studied with regards to retention indices, ionization susceptibility, fragmentation patterns, etc. A custom PFAS database was constructed from 141 diverse PFAS. The database contains mass spectra from electron ionization (EI) mode, as well as MS and MS/MS spectra from positive and negative chemical ionization (PCI and NCI, respectively) modes. Common fragments of PFAS were identified across a diverse set of 141 PFAS analyzed. A workflow for suspect screening of PFAS and partially fluorinated products of incomplete combustion/destruction (PICs/PIDs) was developed which utilized both the custom PFAS database and external databases. PFAS and other fluorinated compounds were identified in both a challenge sample (designed to test the identification workflow) and incineration samples suspected to contain PFAS and fluorinated PICs/PIDs. The challenge sample resulted in a 100% true positive rate (TPR) for PFAS which were present in the custom PFAS database. In conclusion, several fluorinated species were tentatively identified in the incineration samples using the developed workflow.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Group hexavalent actinide separation from lanthanides using sodium bismuthate chromatography

Advanced used nuclear fuel (UNF) reprocessing strategies are limited by the complex radiochemical separations and engineering required to achieve the separation of actinides (An) from neutron scavenging lanthanides (Ln). The accessibility of the hexavalent oxidation state for the actinides (U – Am) provides a pathway to achieving a group hexavalent actinide separation from the trivalent lanthanides and Cm. The solid oxidant and ion exchanger, sodium bismuthate (NaBiO 3 ), has been demonstrated to quantitatively oxidize and separate Am from trivalent Cm in a column chromatographic system. This work expands on the use of NaBiO 3 chromatography to characterize the adsorption, kinetic, and elution behavior of U, Pu, and Eu. Separation factors over 200 with rapid kinetics were observed at dilute nitric acid concentrations with a complete An/Ln separation achieved in under an hour. In conclusion, the adsorption and chromatographic behavior of key fission products present in various reprocessing raffinates was characterized which demonstrated potential application of a NaBiO 3 -based separation following a TRUEX process.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Deep eutectic solvents as green and sustainable diluents in headspace gas chromatography for the determination of trace level genotoxic impurities in pharmaceuticals

Genotoxic impurities (GTIs) are potential carcinogens that need to be controlled down to ppm or lower concentration levels in pharmaceuticals under strict regulations. The static headspace gas chromatography (HS-GC) coupled with electron capture detection (ECD) is an effective approach to monitor halogenated and nitroaromatic genotoxins. Deep eutectic solvents (DESs) possess tunable physico-chemical properties and low vapor pressure for HS-GC methods. In this study, zwitterionic and non-ionic DESs have been used for the first time to develop and validate a sensitive analytical method for the analysis of 24 genotoxins at sub-ppm concentrations. Compared to non-ionic diluents, zwitterionic DESs produced exceptional analytical performance and the betaine: 7 (1,4- butane diol) DES outperformed the betaine: 5 (1,4-butane diol) DES. Limits of detection (LOD) down to the 5-ppb concentration level were achieved in DESs. Wide linear ranges spanning over 5 orders of magnitude (0.005–100 µg g –1 ) were obtained for most analytes with exceptional sensitivities and high precision. The method accuracy and precision were validated using 3 commercially available drug substances and excellent recoveries were obtained. Finally, this study broadens the applicability of HS-GC in the determination of less volatile GTIs by establishing DESs as viable diluent substitutes for organic solvents in routine pharmaceutical analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Liquid chromatography at critical conditions (LCCC): Capabilities and limitations for polymer analysis

This paper investigates liquid chromatography at critical condition (LCCC) for polymer analysis. Based on controversial claims on the separation of cyclic polymers from linear analogues in the literature, the efficiency of LCCC for separation and purity analysis is questioned. Polyisobutylene (PIB) and poly(3,6-dioxa-1,8-octanedithiols) (polyDODT) were used for the study. Here, the structure of low molecular weight cyclic and linear polyDODT was demonstrated by MALDI-ToF. NMR did not show the presence of thiol end groups in higher molecular weight PIB-disulfide and polyDODT samples, so they were considered cyclic polymers. When a low molecular weight polyDODT oligomer with only traces of cycles, as demonstrated by MALDI-ToF, was mixed with an M n = 27K g/mol cyclic sample, LCCC did not detect the presence of linear oligomers at 6 wt%. Based on the data presented here, it can be concluded that the LCCC method is not capable of measuring < 6 wt% linear contamination so earlier claims for cyclic polystyrene (PS) samples purified by LCCC having < 3 % linear contaminants are questioned.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid recovery of At-211 by extraction chromatography

The near quantitative separation, purification, and recovery of 211 At has been demonstrated through an extraction chromatography process which utilizes porous beads impregnated with 3-octanone, resulting in an elution yield of 92–95%. Moreover, the rapid nature of this process, <20 min, was achieved after dissolution of a Bi metal target in HNO 3 following retrieval from the beamline after α-particle bombardment. The solution was directly loaded onto the column with no volume or acidity adjustment. The column was washed with HNO 3 and H 2 O, and 211 At was eluted with ethanol, collecting roughly 87–93% in 1 mL. This process of recovering high purity 211 At, in near quantitative yields, represents a significant advance in At separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Short-term toxicity assessments of an antibiotic metabolite in Wistar rats and its metabonomics analysis by ultra-high performance liquid chromatography coupled to quadrupole time-of-flight mass spectrometry

4-Epi-oxytetracycline (4-EOTC), one of main oxytetracycline (OTC) metabolites, can be commonly detected in food and environment. The toxicity and effects of OTC on animals have been well characterized; however, its metabolites have never been studied systemically. This study aims to investigate 15-day oral dose toxicity and urine metabonomics changes of 4-EOTC after repeated administration in Wistar rats at daily doses of 0.5, 5.0 and 50.0 mg/kg bw (bodyweight). Hematology and clinical chemistry parameters, including white blood cell count, red blood cell count, total protein, globulin and albumin/globulin, were obviously altered in rats of 5.0 and 50.0 mg/kg bw. Histopathology changes of kidney and liver tissues were also observed in high-dose groups. Urinary metabolites from all groups were analyzed using ultra-high performance liquid chromatography coupled to quadrupole time-of-flight mass spectrometry (UPLC-Q-TOF/MS). Seventeen metabolites contributing to the clusters were identified as potential biomarkers from multivariate analysis, including aminoadipic acid, 6-phosphogluconate, sebacic acid, pipecolic acid, etc. The significant changes of these biomarkers demonstrated metabonomic variations in treated rats, especially lysine and purine metabolism. For the first time in this paper, we combined the results of toxicity and metabonomics induced by 4-EOTC for the serious reconsideration of the safety and potential risks of antibiotics and its degradation metabolites. - Highlights: • 4-Epioxytetracycline (4-EOTC) induced damages in liver and kidney. • Metabonomics changes especially amino acid and purine metabolism were observed. • Security of OTC metabolite 4-EOTC should be taken into serious reconsideration.

60 APPLIED LIFE SCIENCES↗

Tile-Based Fisher-Ratio Software for Improved Feature Selection Analysis of Comprehensive Two-Dimensional Gas Chromatography Time-of-Flight Mass Spectrometry Data

Two-dimensional (2D) gas chromatography coupled with time-of-flight mass spectrometry (GC × GC – TOFMS) is a highly capable instrumental platform that produces complex and information-rich multi-dimensional chemical data. The complex data can be overwhelming, especially when many samples (of various sample classes) are analyzed with multiple injections for each sample. Thus, the data must be analyzed in such a way to extract the most meaningful information. The pixel-based and peak table-based algorithmic use of Fisher ratios has been used successfully in the past to reduce the multi-dimensional data down to those chemical compounds that are changing between classes relative to those that are not (i.e., chemical feature selection). We report on the initial development of a computationally fast novel tile-based Fisher-ratio software that addresses challenges due to 2D retention time misalignment without explicitly aligning the data, which is a problem for both pixel-based and peak table- based methods. Concurrently, the tile-based Fisher-ratio software maximizes the sensitivity contrast of true positives against a background of potential false positives and noise. To study this software, eight compounds, plus one internal standard, were spiked into diesel at various concentrations. The tile-based F-ratio software was able to discover all spiked analytes, within the complex diesel sample matrix with thousands of potential false positives, in each possible concentration comparison, even at the lowest absolute spiked analyte concentration ratio of 1.06.

chemometrics↗