Search NASA⌕ Search

SEARCH · Search NASA

Results for “CI testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

SU-F-R-53: CT-Based Radiomics Analysis of Non-Small Cell Lung Cancer Patients Treated with Stereotactic Body Radiation Therapy

Purpose: Stereotactic body radiation therapy (SBRT) is the standard of care for medically inoperable non-small cell lung cancer (NSCLC) patients and has demonstrated excellent local control and survival. However, some patients still develop distant metastases and local recurrence, and therefore, there is a clinical need to identify patients at high-risk of disease recurrence. The aim of the current study is to use a radiomics approach to identify imaging biomarkers, based on tumor phenotype, for clinical outcomes in SBRT patients. Methods: Radiomic features were extracted from free breathing computed tomography (CT) images of 113 Stage I-II NSCLC patients treated with SBRT. Their association to and prognostic performance for distant metastasis (DM), locoregional recurrence (LRR) and survival was assessed and compared with conventional features (tumor volume and diameter) and clinical parameters (e.g. performance status, overall stage). The prognostic performance was evaluated using the concordance index (CI). Multivariate model performance was evaluated using cross validation. All p-values were corrected for multiple testing using the false discovery rate. Results: Radiomic features were associated with DM (one feature), LRR (one feature) and survival (four features). Conventional features were only associated with survival and one clinical parameter was associated with LRR and survival. One radiomic feature was significantly prognostic for DM (CI=0.670, p<0.1 from random), while none of the conventional and clinical parameters were significant for DM. The multivariate radiomic model had a higher median CI (0.671) for DM than the conventional (0.618) and clinical models (0.617). Conclusion: Radiomic features have potential to be imaging biomarkers for clinical outcomes that conventional imaging metrics and clinical parameters cannot predict in SBRT patients, such as distant metastasis. Development of a radiomics biomarker that can identify patients at high-risk of recurrence could facilitate personalization of their treatment regimen for an optimized clinical outcome. R.M. had consulting interest with Amgen (ended in 2015).

60 APPLIED LIFE SCIENCES↗

Understanding the Competition between Alcohol Formation and Dimerization during Electrochemical Reduction of Aromatic Carbonyl Compounds

The electrochemical reductive dimerization of small aromatic carbonyl compounds derived from lignocellulosic biomass is a crucial C−C coupling reaction for upgrading small molecules to longchain hydrocarbons, particularly in the synthesis of drop-in sustainable aviation fuels. Although other electrochemical reduction reactions of these reactants (i.e., hydrogenation and hydrogenolysis) have undergone extensive mechanistic investigation, the understanding of dimerization remains relatively underdeveloped. Most importantly, there is a lack of understanding of the selectivity-determining step between dimerization and monomer reduction and critical factors that can affect this step. In this study, we provide a comprehensive mechanistic model to explain the competition between dimerization and monomer reduction of benzaldehyde under various conditions. Our model proposes that the selectivity between dimerization and monomer reduction depends on the competition between desorption of a ketyl radical from the electrode, necessary for dimerization, and further reduction of the ketyl radical to an alcohol on the electrode by proton-coupled electron transfer (PCET). Computationally comparing the adsorption/desorption energy and PCET activation barrier energy is challenging because conventional DFT calculations substantially underestimate the PCET kinetic barriers. In this study, we employed constrained DFTbased configuration interaction (CDFT-CI) to obtain a reliable comparison of these energies. Our mechanistic model was tested and supported by experimental results obtained with four electrodes (Cu, Pb, Bi, graphite), three pH conditions (acidic, neutral, basic), and three potentials. Our study offers a coherent mechanistic foundation that can explain how each of these conditions impacts the desorption and PCET processes and the selectivities for dimerization and alcohol production.

09 BIOMASS FUELS↗

SU-F-BRD-05: Dosimetric Comparison of Protocol-Based SBRT Lung Treatment Modalities: Statistically Significant VMAT Advantages Over Fixed- Beam IMRT

Purpose: The purpose of this study is to inter-compare and find statistically significant differences between flattened field fixed-beam (FB) IMRT with flattening-filter free (FFF) volumetric modulated arc therapy (VMAT) for stereotactic body radiation therapy SBRT. Methods: SBRT plans using FB IMRT and FFF VMAT were generated for fifteen SBRT lung patients using 6 MV beams. For each patient, both IMRT and VMAT plans were created for comparison. Plans were generated utilizing RTOG 0915 (peripheral, 10 patients) and RTOG 0813 (medial, 5 patients) lung protocols. Target dose, critical structure dose, and treatment time were compared and tested for statistical significance. Parameters of interest included prescription isodose surface coverage, target dose heterogeneity, high dose spillage (location and volume), low dose spillage (location and volume), lung dose spillage, and critical structure maximum- and volumetric-dose limits. Results: For all criteria, we found equivalent or higher conformality with VMAT plans as well as reduced critical structure doses. Several differences passed a Student's t-test of significance: VMAT reduced the high dose spillage, evaluated with conformality index (CI), by an average of 9.4%±15.1% (p=0.030) compared to IMRT. VMAT plans reduced the lung volume receiving 20 Gy by 16.2%±15.0% (p=0.016) compared with IMRT. For the RTOG 0915 peripheral lesions, the volumes of lung receiving 12.4 Gy and 11.6 Gy were reduced by 27.0%±13.8% and 27.5%±12.6% (for both, p<0.001) in VMAT plans. Of the 26 protocol pass/fail criteria, VMAT plans were able to achieve an average of 0.2±0.7 (p=0.026) more constraints than the IMRT plans. Conclusions: FFF VMAT has dosimetric advantages over fixed beam IMRT for lung SBRT. Significant advantages included increased dose conformity, and reduced organs-at-risk doses. The overall improvements in terms of protocol pass/fail criteria were more modest and will require more patient data to establish difference trends of more statistical significance.

60 APPLIED LIFE SCIENCES↗

An assessment of CFD-based wall heat transfer models in piston engines

The lack of accurate submodels for in-cylinder heat transfer has been identified as a key shortcoming in developing truly predictive, physics-based computational fluid dynamics (CFD) models that can be used to develop combustion systems for advanced high-efficiency, low-emissions engines. Only recently have experimental methods become available that enable accurate near-wall measurements to enhance simulation capability via advancing models. Initial results show crank-angle dependent discrepancies with respect to previously used boundary-layer models of up to 100%. However, available experimental data is quite sparse (only few data points on engine walls) and limited (available measurements are those of heat flux only). Predictive submodels are needed for medium-resolution ("engineering") LES and for unsteady Reynolds-averaged simulations (URANS). Recently, some research groups have performed DNS studies on engine-relevant conditions using simple geometries. These provide very useful data for benchmarking wall heat transfer models under such conditions. Further, a number of new and more sophisticated models have also become available in the literature which account for these engine-like conditions. Some of these have been incorporated while others of a more complex nature, which include solving additional partial differential equations (PDEs) within the thin boundary layer near the wall, are underway. These models will then be tested against the available DNS/experimental data in both SI (spark-ignition) and CI (compression-ignition) engines.

33 ADVANCED PROPULSION SYSTEMS↗

Detection of Special Nuclear Material in Cargo using Continuous Neutron Interrogation and Tension Metastable Fluid Detectors

This paper presents results using a novel technique for detecting special nuclear materials (SNMs) based on interrogation with a continuous beam of 2.45 MeV neutrons coupled with high intrinsic efficiency tensioned metastable fluid detectors (TMFDs) operated in threshold rejection mode. While passive interrogation may be utilized for detecting SNMs such as {sup 239}Pu from their strong spontaneous fission neutron signatures, this is not so for highly-enriched uranium (HEU), the timely detection of which has been identified as a grand challenge by the U.S. Domestic Nuclear Detection Office (DNDO). Active (neutron and/or photon based) interrogation represents the only viable means for detecting HEU either shielded or unshielded within cargo containers. Active interrogation by neutrons or photons leads to unequivocal induced fission based signatures in terms of neutron energy and multiplicity. The main challenge under such circumstances pertains to being able to discern the relatively weak emission signatures from the intense interrogation pulses of neutrons and/or photons. Purdue University together with Sagamore Adams Laboratories, LLC (SAL) has been developing the TMFD sensor system that promises to provide high neutron detection efficiency for fast and thermal neutrons while remaining gamma-beta blind. As described in these references, the TMFD sensor system works on the principle of transient cavitation detection events (CDEs) caused by ionizing particles such as neutrons, alphas and fission fragments in fluids that have been placed in various states of tensioned (sub-zero) pressure states of fluid metastability. Such CDEs result in recordable signatures - both electronically as for conventional detectors, but also in the form of audio-visual signals. One key advantage that the TMFD holds over conventional neutron detectors is that it has proven gamma-beta 'blindness' and indeed, confirmed to possess GARRn = 1.0 to γ photons (tested in up to 10{sup 11} γ/s field from a 3 Ci {sup 137}Cs source). Such an enablement allows for detection without saturation from background, interrogating and fission created γ photons. Another key attribute is up to 60 % intrinsic fission spectrum neutron detection efficiency which, furthermore, is amenable to tailoring for threshold based rejection. That is, to be able to detect neutrons at or above a desired energy with good efficiency, while remaining relatively blind to neutrons below the chosen threshold. This research is the subject of our ongoing DNDO project at Purdue University, the results of which form the basis of this paper. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-R-52: A Comparison of the Performance of Radiomic Features From Free Breathing and 4DCT Scans in Predicting Disease Recurrence in Lung Cancer SBRT Patients

Purpose: There is a clinical need to identify patients who are at highest risk of recurrence after being treated with stereotactic body radiation therapy (SBRT). Radiomics offers a non-invasive approach by extracting quantitative features from medical images based on tumor phenotype that is predictive of an outcome. Lung cancer patients treated with SBRT routinely undergo free breathing (FB image) and 4DCT (average intensity projection (AIP) image) scans for treatment planning to account for organ motion. The aim of the current study is to evaluate and compare the prognostic performance of radiomic features extracted from FB and AIP images in lung cancer patients treated with SBRT to identify which image type would generate an optimal predictive model for recurrence. Methods: FB and AIP images of 113 Stage I-II NSCLC patients treated with SBRT were analysed. The prognostic performance of radiomic features for distant metastasis (DM) was evaluated by their concordance index (CI). Radiomic features were compared with conventional imaging metrics (e.g. diameter). All p-values were corrected for multiple testing using the false discovery rate. Results: All patients received SBRT and 20.4% of patients developed DM. From each image type (FB or AIP), nineteen radiomic features were selected based on stability and variance. Both image types had five common and fourteen different radiomic features. One FB (CI=0.70) and five AIP (CI range=0.65–0.68) radiomic features were significantly prognostic for DM (p<0.05). None of the conventional features derived from FB images (range CI=0.60–0.61) were significant but all AIP conventional features were (range CI=0.64–0.66). Conclusion: Features extracted from different types of CT scans have varying prognostic performances. AIP images contain more prognostic radiomic features for DM than FB images. These methods can provide personalized medicine approaches at low cost, as FB and AIP data are readily available within a large number of radiation oncology departments. R.M. had consulting interest with Amgen (ended in 2015).

60 APPLIED LIFE SCIENCES↗

SU-E-T-28: A Treatment Planning Comparison of Volumetric Modulated Arc Therapy Vs. Proton Therapy for Post-Mastectomy Radiotherapy

Purpose: The delivery of post-mastectomy radiotherapy (PMRT) can be challenging for patients with left-sided breast cancer due to the PTV size and proximity to critical organs. This study investigates the use of protons for PMRT in a clinically-representative cohort of patients, and quantitatively compares volumetric modulated arc therapy (VMAT) to proton therapy to have an evidence-based rationale for selecting a treatment modality for these patients. Methods: Eight left-sided PMRT patients previously treated at our clinic with VMAT were identified for the study. PTVs included the chest wall and regional lymph nodes. Passively scattered (PS) and intensity modulated proton therapy (IMPT) plans were constructed using the Eclipse proton planning system. The resulting plans were compared to the original VMAT plan on the basis of PTV coverage; dose homogeneity index (DHI) and conformity index (CI); dose to organs at risk (OAR); tumor control probability (TCP), normal tissue complication probability (NTCP) and secondary cancer complication probability (SCCP). Differences were tested for significance using the paired Student's t-test (p<0.01). Results: All modalities produced clinically acceptable PMRT plans. The comparison demonstrated proton treatment plans provide significantly lower NTCP values for the heart and the lung while maintaining significantly better CI and DHI. At a prescribed dose of 50.4 Gy (RBE) in the PTV, the calculated mean NTCP value for the patients decreased from 1.3% to 0.05% for the whole heart (cardiac mortality) and from 3.8% to 1.1% for the lungs (radiation pneumonitis) for both proton therapy plans from VMAT plans. Both proton modalities showed a significantly lower SCCP for the contralateral breast compared to VMAT. Conclusion: All three plans (VMAT, PS, and IMPT) provide acceptable treatment plans for PMRT. However, proton therapy shows a significant advantage over VMAT with regards to sparing OARs and may be more advantageous for patients with unfavorable anatomy.

60 APPLIED LIFE SCIENCES↗

Near-Cloud Atmospheric Ingredients for Deep Convection Initiation

A lack of routine environmental observations located near deepening cumulus congestus clouds limits verification of important theorized and simulated updraft–environment interaction processes occurring during deep convection initiation (CI). We analyze radiosonde profiles collected during several hundred CI events near a mountain range in central Argentina during the CACTI field campaign. Statistical analyses illustrate environmental conditions supporting radar-observed CI outcomes that span a spectrum of convective cell depths, widths, and durations, as well as events lacking precipitating convection. Tested environmental factors include a large variety of sounding-derived measurements of CAPE, CIN, moisture, terrain-relative winds, vertical shear, and lifted parcel properties, with supplemental model reanalysis of background larger-scale vertical motion. CAPE and CIN metrics do not consistently differentiate CI success from failure. Only a few environmental factors contain consistent monotonic relationships among the spectrum of cloud depths achieved during CI: (i) the depth and strength of background ascent, and (ii) the component of low-level flow oriented parallel to the ridgeline. These metrics suggest that the ability of the surrounding flow to lift parcels to their LFC and terrain-modified flow are consistently relevant processes for CI. Low- to midlevel relative humidity strongly discriminated between CI and non-CI events, likely reflecting entrainment-driven dilution processes. However, we could not confidently conclude that relative humidity similarly discriminated robust from marginal CI events. Circumstantial evidence was found linking cell width, an important cloud property governing the probability of CI, to LCL height, boundary layer depth, depth and magnitude of the CIN layer, and ambient wind shear.

Storm environments↗

Reduction in Tumor Volume by Cone Beam Computed Tomography Predicts Overall Survival in Non-Small Cell Lung Cancer Treated With Chemoradiation Therapy

Purpose: We sought to evaluate whether tumor response using cone beam computed tomography (CBCT) performed as part of the routine care during chemoradiation therapy (CRT) could forecast the outcome of unresectable, locally advanced, non-small cell lung cancer (NSCLC). Methods and Materials: We manually delineated primary tumor volumes (TV) of patients with NSCLC who were treated with radical CRT on days 1, 8, 15, 22, 29, 36, and 43 on CBCTs obtained as part of the standard radiation treatment course. Percentage reductions in TV were calculated and then correlated to survival and pattern of recurrence using Cox proportional hazard models. Clinical information including histologic subtype was also considered in the study of such associations. Results: We evaluated 38 patients with a median follow-up time of 23.4 months. The median TV reduction was 39.3% (range, 7.3%-69.3%) from day 1 (D1) to day 43 (D43) CBCTs. Overall survival was associated with TV reduction from D1 to D43 (hazard ratio [HR] 0.557, 95% CI 0.39-0.79, P=.0009). For every 10% decrease in TV from D1 to D43, the risk of death decreased by 44.3%. For patients whose TV decreased ≥39.3 or <39.3%, log-rank test demonstrated a separation in survival (P=.02), with median survivals of 31 months versus 10 months, respectively. Neither local recurrence (HR 0.791, 95% CI 0.51-1.23, P=.29), nor distant recurrence (HR 0.78, 95% CI 0.57-1.08, P=.137) correlated with TV decrease from D1 to D43. Histologic subtype showed no impact on our findings. Conclusions: TV reduction as determined by CBCT during CRT as part of routine care predicts post-CRT survival. Such knowledge may justify intensification of RT or application of additional therapies. Assessment of genomic characteristics of these tumors may permit a better understanding of behavior or prediction of therapeutic outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance of Windows in Walls With Continuous Insulation

Window openings in walls are a significant contributor to poor thermal performance because of thermal bridging through the framing members (e.g., studs, joists, plates, bracing) and because windows lack the thermal properties of insulation. Window installation guidance for walls with continuous insulation (CI) is critical for continued market growth of this energy efficiency technology. This research project offers window manufacturers a starting point and a potential path toward developing installation instructions for windows over CI. The objectives of the research include evaluating the common method for installing windows in walls with CI, as well as establishing acceptance criteria for evaluating the performance of windows installed in walls with and without CI. The research measures: 1. The performance characteristics (e.g., water management, structural integrity) of windows in walls without CI. 2. The performance of different thicknesses and types of CI used in walls. 3. The performance of different types of window assemblies (e.g., double-hung windows, mulled double-hung windows, mulled casement windows, and slider windows) installed over CI. 4. The performance of window flange types (e.g., rigid mounting and less robust flanges) installed over CI. 5. Installing windows over CI using baseline installation instructions versus window manufacturer installation instructions. The project’s sequential testing protocol consists of the following: • A water penetration resistance testing adapted from two ASTM standards: E331 (uniform static air pressure in four steps) and E547 (cyclic static air pressure) • A temperature cycling adapted from ASTM E2264 Method B (convective hot air) • A service condition wind loading test adapted from ASTM E330 • A six-month vertical displacement observation phase prior to the structural performance testing • A final water penetration resistance test after vertical displacement observation • A structural performance test adapted from ASTM E330. Key research findings include: • The criterion for passing a water penetration resistance test is that there is no water overflowing at the interior face of the studs. If there is any bubbling or slight pooling of water at the sill, then it must recede after the pressure is removed. Excessive leakage and/or water leaking to the interior face of the framing around the window constitutes a failure. • All single double-hung windows installed directly to lumber or over oriented strand board passed all test protocols. • For most wall specimens, the test results showed that the use of foam sheathing did not affect the performance of the window for water leakage. • All wall specimens underwent temperature cycling. The results indicated that temperature cycling had little to no effect on windows installed over foam sheathing. • For wall specimens that underwent six-month vertical displacement monitoring, the results showed that windows installed over foam sheathing do not sag over time. • The single-hung and double-hung windows installed using window manufacturer installation instructions passed the structural performance test, compared to failures observed in windows that were installed using generic installation instructions. The generic and manufacturer installation methods differed on the following construction details: type of fasteners, fastening patterns on the flanges, and window shimming details. • Additional testing is required to determine methods to improve structural pressure performance of slider windows. Potential solutions that would require additional testing may include fastener spacing, different types of fasteners, masonry window clips, construction adhesive, foam sealant, stronger window flange material, and/or straps.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Synthesis and Corrosion Study of Zirconia-Coated Carbonyl Iron Particles

This paper describes the surface modification of micrometer-sized magnetic carbonyl iron particles (CI) with zirconia from zirconium(IV) butoxide using a sol–gel method. Zirconia shells with various thicknesses and different grain sizes and shapes are coated on the surface of CI particles by changing the reaction conditions, such as the amounts of zirconia sol, nitric acid, and CI particles. A silica adhesive layer made from 3-aminopropyl trimethoxysilane (APTMS) can be introduced first onto the surface of CI particles in order to adjust both the size and the shape of zirconia crystals, and thus the roughness of the coating. The microanalyses on these coated particles are studied by field-emission scanning electron microscopy (FE-SEM) and X-ray-diffraction (XRD). Accelerated acid corrosion and air oxidation tests indicate that the coating process dramatically improved oxidation and acid corrosion resistances, which are critical issues in various applications of CI magnetic particles.

carbonyl iron↗

Adjuvant Radiotherapy for Palpable Melanoma Metastases to the Groin: When to Irradiate?

Purpose: To determine the efficacy of and criteria for postoperative radiotherapy (PORT) in patients with palpable melanoma metastases to the groin. Methods and Materials: Patients with palpable metastases to the groin who were treated with therapeutic nodal dissection during 2000 to 2006 were identified in a prospective institutional database. Results: In 101 patients, 103 therapeutic nodal dissections were performed; 37 of these were treated with PORT to a median equivalent dose (eqTD{sub 2}) of 50.6 Gy (range, 50-72 Gy). In the surgery-only and PORT groups, 2-year regional control rates were 86% (95% confidence interval [CI] 76-95%) and 91% (95% CI, 81-100%), respectively (p = 0.395). Of five recurrences in radiation-treated patients, four were of dermal type, and in three of these cases, no bolus over the operative scar was used. PORT improved 2-year regional control (46% [95% CI, 11-82%] vs. 82% [95% CI, 63-100%], p = 0.022) among patients in which the sum of risk factors present (i.e., risk factor score) was {>=}2. In multivariate analysis, risk-factor score (<2 vs. {>=}2: HR, 2.93; 95% CI, 1.00-8.56; p < 0.0001) and PORT (yes vs. no: HR, 7.81; 95% CI, 2.83-21.74; p = 0.050) was predictive for regional control and on logistic-regression testing, number of involved lymph nodes was predictive for systemic dissemination (p = 0.011). Conclusions: PORT should follow therapeutic nodal dissection in cases with two or more adverse factors. More conventional fractionation ({<=}2.5 Gy), cumulative eqTD{sub 2} <60 Gy and use of bolus over the operative scar are recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Compatibility of polymers in super-critical carbon dioxide for power generation systems: High level findings for low temperatures and pressure conditions

Polymers such as PTFE (polytetrafluorethylene or Teflon), PEEK (polyetheretherketone), EPDM (ethylene propylene cliene monomer) rubber, Viton, EPR (ethylene propylene rubber), Nylon, Nitrile rubber, and perfluoroelastomers are commonly employed in super critical CO 2 (sCO2) energy conversion systems. O-rings and gaskets made from these polymers face stringent performance conditions such as elevated temperatures, high pressures, pollutants and corrosive humid environments. Critical knowledge gaps about polymer degradation from sCO2 exposure need to be addressed. To understand these effects, we have studied nine commonly used polymers subjected to elevated temperatures under isobaric conditions of sCO2 pressure. The polymers (PEEK, Nylon, PTFE, EPDM, Nitrile rubber, EPR, Neoprene, perfluoroelastomer FF 202 and Viton) were exposed for 1000 hours at 100°C to 25 MPa sCO2 pressure in an autoclave. In a second study, elastomers perfluoroelastomer (FF202) and EPDM were exposed to 25 MPa sCO2 for 1000 hours at 150°C. Samples were extracted for ex-situ characterization at t = 200 hours and then at the completion of the test at t=1000 hours. The polymer samples were examined for physical and chemical changes by Dynamic Mechanical and Thermal Analysis (DMTA), Fourier Transform Infrared (FTIR) spectroscopy, and compression set. Density and mass changes immediately after removal from test and 48 hours later, and optical microscopy techniques were also used. Microcomputer tomography (micro CI) data was generated on select specimens. Super-critical CO 2 effects have been identified as either physical or chemical effects. For each polymer, the dominance of one type of effect over the other was evaluated. Attempts were also made to qualitatively link sCO2 effects such as lowering or increase in glass transition temperatures, storage modulus changes, mass and compression set changes, chemical changes seen in FTIR analyses and blister and void formation seen post-exposure to polymer microstructure-related mechanisms such as plasticization of the polymer matrix, escape of volatiles from the polymer during depressurization, and filler and plasticizer effects on microstructure with rapid depressurization rates.

36 MATERIALS SCIENCE↗

SU-E-T-122: Anisotropic Analytical Algorithm (AAA) Vs. Acuros XB (AXB) in Stereotactic Treatment Planning

Purpose: To evaluate dosimetric differences between superposition beam model (AAA) and determinant photon transport solver (AXB) in lung SBRT and Cranial SRS dose computations. Methods: Ten Cranial SRS and ten Lung SBRT plans using Varian, AAA -11.0 were re-planned using Acuros -XB-11.0 with fixed MU. 6MV photon Beam model with HD120-MLC used for dose calculations. Four non-coplanar conformal arcs used to deliver 21Gy or 18Gy to SRS targets (0.4 to 6.2cc). 54Gy (3Fractions) or 50Gy (5Fractions) was planned for SBRT targets (7.3 to 13.9cc) using two VAMT non-coplanar arcs. Plan comparison parameters were dose to 1% PTV volume (D1), dose to 99% PTV volume( D99), Target mean (Dmean), Conformity index (ratio of prescription isodose volume to PTV), Homogeneity Index [ (D2%-D98%)/Dmean] and R50 (ratio of 50% of prescription isodose volume to PTV). OAR parameters were Brain volume receiving 12Gy dose (V12Gy) and maximum dose (D0.03) to Brainstem for SRS. For lung SBRT, maximum dose to Heart and Cord, Mean lung dose (MLD) and volume of lung receiving 20Gy (V20Gy) were computed. PTV parameters compared by percentage difference between AXB and AAA parameters. OAR parameters and HI compared by absolute difference between two calculations. For analysis, paired t-test performed over the parameters. Results: Compared to AAA, AXB SRS plans have on average 3.2% lower D99, 6.5% lower CI and 3cc less Brain-V12. However, AXB SBRT plans have higher D1, R50 and Dmean by 3.15%, 1.63% and 2.5%. For SRS and SBRT, AXB plans have average HI 2 % and 4.4% higher than AAA plans. In both techniques, all other parameters vary within 1% or 1Gy. In both sets only two parameters have P>0.05. Conclusion: Even though t-test results signify difference between AXB and AAA plans, dose differences in dose estimations by both algorithms are clinically insignificant.

60 APPLIED LIFE SCIENCES↗

Impact of Genomic Methylation on Radiation Sensitivity of Colorectal Carcinoma

Purpose: To investigate the influence of demethylation with 5-aza-cytidine (AZA) on radiation sensitivity and to define the intrinsic radiation sensitivity of methylation deficient colorectal carcinoma cells. Methods and Materials: Radiation sensitizing effects of AZA were investigated in four colorectal carcinoma cell lines (HCT116, SW480, L174 T, Co115), defining influence of AZA on proliferation, clonogenic survival, and cell cycling with or without ionizing radiation. The methylation status for cancer or DNA damage response-related genes silenced by promoter methylation was determined. The effect of deletion of the potential target genes (DNMT1, DNMT3b, and double mutants) on radiation sensitivity was analyzed. Results: AZA showed radiation sensitizing properties at >=1 {mu}mol/l, a concentration that does not interfere with the cell cycle by itself, in all four tested cell lines with a sensitivity-enhancing ratio (SER) of 1.6 to 2.1 (confidence interval [CI] 0.9-3.3). AZA successfully demethylated promoters of p16 and hMLH1, genes associated with ionizing radiation response. Prolonged exposure to low-dose AZA resulted in sustained radiosensitivity if associated with persistent genomic hypomethylation after recovery from AZA. Compared with maternal HCT116 cells, DNMT3b-defcient deficient cells were more sensitive to radiation with a SER of 2.0 (CI 0.9-2.1; p = 0.03), and DNMT3b/DNMT1-/- double-deficient cells showed a SER of 1.6 (CI 0.5-2.7; p = 0.09). Conclusions: AZA-induced genomic hypomethylation results in enhanced radiation sensitivity in colorectal carcinoma. The mediators leading to sensitization remain unknown. Defining the specific factors associated with radiation sensitization after genomic demethylation may open the way to better targeting for the purpose of radiation sensitization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accomplishments of Sandia and Kitware CMake/CTest/CDash Contract for (FY2017-2020)

We describe the accomplishments jointly achieved by Kitware and Sandia over the fiscal years 2016 through 2020 to benefit the Advanced Scientific Computed (ASC) Advanced Technology Development and Mitigation (ATDM) project. As a result of our collaboration, we have improved the Trilinos and ATDM application developer experience by decreasing the time to build, making it easier to identify and resolve build and test defects, and addressing other issues . We have also reduced the turnaround time for continuous integration (CI) results. For example, the combined improvements likely cut the wall clock time to run automated builds of Trilinos posting to CDash by approximately 6x or more in many cases. We primarily achieved these benefits by contributing changes to the Kitware CMake/CTest/CDash suite of open source software development support tools. As a result, ASC developers can now spend more time improving code and less time chasing bugs. And, without this work, one can argue that the stabilization of Trilinos for the ATDM platforms would not have been feasible which would have had a large negative impact on an important internal FY20 L1 milestone.

97 MATHEMATICS AND COMPUTING↗

Seroprevalence of Herpes Simplex Virus type-2 (HSV-2) among pregnant women who participated in a national HIV surveillance activity in Haiti

Background: Herpes simplex virus type 2 (HSV-2), one the most common causes of genital ulcers, appears to increase both the risk of HIV acquisition and HIV transmission. HSV-2/HIV co-infection among pregnant women may increase the risk of perinatal transmission of HIV. This study describes rates of HSV-2 among pregnant women in Haiti and HSV-2 test performance in this population. Methods: Unlinked residual serum specimens from the 2012 National HIV and Syphilis Sentinel Surveillance Survey among pregnant women in Haiti were tested using two commercial kits (Focus HerpeSelect, Kalon) for HSV-2 antibodies. We evaluated rates of HSV-2 seropositivity and HSV-2/HIV co-infection, associations between HSV-2 and demographic characteristics using multivariable Cox proportional hazards modeling, and HSV-2 test performance in this population. Results: Serum samples from 1000 pregnant women (all 164 HIV positive and 836 random HIV negative) were selected. The overall weighted prevalence of HSV-2 was 31.4% (95% CI: 27.7–35.4) and the prevalence of HIV-positivity among HSV2 positive pregnant women was five times higher than the prevalence among HSV-2 negative women (4.8% [95% CI: 3. 9–6.0] vs. 0.9% [95% CI: 0.6–1.3], respectively). Factors significantly associated with HSV-2 positivity were HIV-positivity (PR: 2.27 [95% CI: 1.94–2.65]) and older age (PRs: 1.41 [95% CI: 1.05–1.91] for 20–24 years, 1.71 [95% CI:1.13–2.60] for 30– 34 years, and 1.55 [95% CI: 1.10–2.19] for 35 years or greater]), while rural residence was negatively associated with HSV2 positivity (PR 0.83 [95% CI: 0.69–1.00]), after controlling for other covariables. For this study a conservative Focus index cutoff of 3.5 was used, but among samples with a Focus index value ≥2.5, 98.4% had positive Kalon tests. Conclusion: The prevalence of HSV-2 is relatively high among pregnant women in Haiti. Public health interventions to increase access to HSV-2 screening in antenatal services are warranted.

60 APPLIED LIFE SCIENCES↗

Dosimetric effect of beam arrangement for intensity-modulated radiation therapy in the treatment of upper thoracic esophageal carcinoma

To evaluate the lung sparing in intensity-modulated radiation therapy (IMRT) for patients with upper thoracic esophageal tumors extending inferiorly to the thorax by different beam arrangement. Overall, 15 patient cases with cancer of upper thoracic esophagus were selected for a retrospective treatment-planning study. Intensity-modulated radiation therapy plans using 4, 5, and 7 beams (4B, 5B, and 7B) were developed for each patient by direct machine parameter optimization (DMPO). All plans were evaluated with respect to dose volumes to irradiated targets and normal structures, with statistical comparisons made between 4B with 5B and 7B intensity-modulated radiation therapy plans. Differences among plans were evaluated using a two-tailed Friedman test at a statistical significance of p < 0.05. The maximum dose, average dose, and the conformity index (CI) of planning target volume 1 (PTV1) were similar for 3 plans for each case. No significant difference of coverage for planning target volume 1 and maximum dose for spinal cords were observed among 3 plans in present study (p > 0.05). The average V{sub 5}, V{sub 13}, V{sub 20}, mean lung dose, and generalized equivalent uniform dose (gEUD) for the total lung were significantly lower in 4B-plans than those data in 5B-plans and 7B-plans (p < 0.01). Although the average V{sub 30} for the total lung were significantly higher in 4B-plans than those in 5B-plans and 7B-plans (p < 0.05). In addition, when comparing with the 4B-plans, the conformity/heterogeneity index of the 5B- and 7B-plans were significantly superior (p < 0.05). The 4B-intensity-modulated radiation therapy plan has advantage to address the specialized problem of lung sparing to low- and intermediate-dose exposure in the thorax when dealing with relative long tumors extended inferiorly to the thoracic esophagus for upper esophageal carcinoma with the cost for less conformity. Studies are needed to compare the superiority of volumetric modulated arc therapy with intensity-modulated radiation therapy technique.

61 RADIATION PROTECTION AND DOSIMETRY↗