Production, quality assurance and quality control of the SiPM Tiles for the DarkSide-20k Time Projection Chamber

The DarkSide-20k dark matter direct detection experiment will employ a 21 m 2 silicon photomultiplier (SiPM) array, instrumenting a dual-phase 50 tonnes liquid argon Time Projection Chamber (TPC). SiPMs are arranged into modular photosensors called Tiles, each integrating 24 SiPMs onto a printed circuit board (PCB) that provides signal amplification, power distribution, and a single-ended output for simplified readout. Tiles are further grouped into Photo-Detector Units (PDUs). This paper details the production of the Tiles and the Quality Assurance and Quality Control (QA-QC) protocol established to ensure their performance and uniformity. The production and QA-QC of the Tiles are carried out at Nuova Officina Assergi (NOA), an ISO-6 clean room facility at LNGS. This process includes wafer-level cryogenic characterisation, precision die attaching, wire bonding, and extensive electrical and optical validation of each Tile. The overall production yield exceeds 83.5%, matching the requirements of the DarkSide-20k production plan. These results validate the robustness of the Tile design and its suitability for operation in a cryogenic environment.

Acerbi, F. [Fondazione Bruno Kessler]↗

Cleanroom air sampler counts, categorizes, and records particle data

Light scattering particle counter monitors particles in a clean room. It categorizes and records the particles according to size and functions simultaneously in three separate areas. The counter uses a transducer head to transform light signals into electric signals.

Nelson, M. B.↗

Fogging technique used to coat magnesium with plastic

Cleaning process and a fogging technique facilitate the application of a plastic coating to magnesium plates. The cleaning process removes general organic and inorganic surface impurities, oils and greases, and oxides and carbonates from the magnesium surfaces. The fogging technique produces a thin-filmlike coating in a clean room atmosphere.

Mroz, T. S.↗

Miniature spray-painting booth

Transparent spray booth provides method for quality painting and repair of surfaces in clean room or other specialized environments. Overspray and virtually all contaminating vapor and odor can be eliminated. Touch-up painting is achieved with spray gun.

Fee, K. W.↗

Noise diffraction patterns eliminated in coherent optical systems

Lens rotation technique of noise diffraction pattern elimination spreads diffracted energy, normally concentrated over small area of image, over much larger annular area. Technique advantages include simplified lens selecting process, reduced clean room requirements, and low cost equipment requirements.

Grebowsky, G. R.↗

Portable superclean air column device Patent

Portable apparatus producing high velocity annular air column surrounding low velocity, filtered, superclean air central core for industrial clean room environmental control

Kiszko, W.↗

Experimental system for the control of surgically induced infections

The results are presented of the development tests performed on the experimental system for the control of surgically induced infections. Tests were performed on the portable clean room to demonstrate assembly, collapsability, portability and storage. Collapsing, relocating and storing within the surgery room can be accomplished in 12 minutes. The storage envelope dimensions are 1.64 m x 4.24 m x 2.62 m high. The disassembly transfer to another room, and reassembly were demonstrated. The laminar air flow velocity profile within the enclosure was measured. In the undisturbed area of the enclosure the air flow met the Federal Standard 209a requirements of 27.45 meters per minute + or - 6.10 meters per minute. Smoke tests with simulated surgery equipment and personnel in the enclosure did not indicate any detrimental air flow patterns. It is concluded that the system as designed will perform the functions required for its intended use.

Source record↗

Experimental system for the control of surgically induced infections

The development tests to be performed on the experimental system are described in detail. The test equipment, conditions, and procedures are given. The portable clean room tests include assembly, collapsability, portability, and storage; laminar flow rate; static pressure; air flow pattern; and electrostatic buildup. The other tests are on the ventilation system, human factors evaluation, electrical subsystem, and material compatibility.

Tevebaugh, M. D.↗

Aerospace technology and hospital systems

The use of aerospace medical techniques to improve the quality of earth health care systems is discussed. Data are focused on physiological measurements and monitoring, medical information management, clean room technology, and reliability and quality assurance for hospital equipment.

Source record↗

Experimental system for the control of surgically induced infections

The experimental system is described, and the procedures for surgery usage and maintenance are outlined. Basically the system consists of the following: (1) a portable clean room comprised of a horizontal laminar flow filter system and a transparent walled enclosure, (2) a helmet-shoulder pad assembly, (3) a communications system, (4) a helmet ventilation system, and (5) surgical gowns.

Source record↗

Application of planetary quarantine methodology and spacecraft sterilization technology to improved health care delivery.

In 1969 the Jet Propulsion Laboratory undertook an investigation to determine which of its space-derived capabilities could make significant contributions to the improvement of health care delivery in the U.S. The area of planetary quarantine was identified as one of high relevance. Two studies were conducted in this connection. The first study, which could contribute to infection reduction and control, was concerned with conversion of infection implicated complex, nonheat sterilizable equipment to dry heat, sterilizable equipment by changes in design and materials of construction. The second study area related to hospital acquired infection is clean room technology. A definite investigation has been performed to demonstrate and statistically evaluate performance under controlled conditions.

Green, R. H.↗