OPTICAL FREQUENCY COMB -BASED CHARACTERIZATION AND COMPENSATION OF LASER FREQUENCY DRIFT FOR BROADBAND MEASUREMENT OF PHOTONIC DEVICE DISPERSION.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Abstract not provided.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
In a general aspect, a laser system includes a laser and a frequency comb generator system. The laser is configured to generate a laser signal, and the frequency comb generator system is configured to generate a frequency comb based on the laser signal. The frequency comb includes frequency comb signals at respective comb frequencies. The laser system also includes a frequency comb dispersion system configured to spatially separate the frequency comb signals onto respective optical channels of the frequency comb dispersion system. The laser system additionally includes a frequency selector system configured to generate a selected frequency signal from the frequency comb signals after separation. The selected frequency signal includes a target separated frequency comb signal. The laser system also includes a frequency shifter configured to alter the selected frequency signal toward a target output frequency of the laser system.
Optical frequency combs have revolutionized precision measurement, time-keeping, and molecular spectroscopy. A substantial effort has developed around "microcombs": integrating comb-generating technologies into compact, reliable photonic platforms. Current approaches for generating these microcombs involve either the electro-optic (EO) or Kerr mechanisms. Despite rapid progress, maintaining high efficiency and wide bandwidth remains challenging. Here, we introduce a new class of microcomb -- an integrated optical frequency comb generator that combines electro-optics and parametric amplification to yield a frequency-modulated optical parametric oscillator (FM-OPO). In stark contrast to EO and Kerr combs, the FM-OPO microcomb does not form pulses but maintains operational simplicity and highly efficient pump power utilization with an output resembling a frequency-modulated laser. We outline the working principles of FM-OPO and demonstrate them by fabricating the complete optical system in thin-film lithium niobate (LNOI). We measure pump to comb internal conversion efficiency exceeding 93% (34% out-coupled) over a nearly flat-top spectral distribution spanning approximately 1,000 modes (approximately 6 THz). Compared to an EO comb, the cavity dispersion rather than loss determines the FM-OPO bandwidth, enabling broadband combs with a smaller RF modulation power. The FM-OPO microcomb, with its robust operational dynamics, high efficiency, and large bandwidth, contributes a new approach to the field of microcombs and promises to herald an era of miniaturized precision measurement, and spectroscopy tools to accelerate advancements in metrology, spectroscopy, telecommunications, sensing, and computing.
Photonic platforms with χ (2) nonlinearity offer new degrees of freedom for Kerr frequency comb development. Here, we demonstrate Kerr soliton generation at 1550 nm with phase-matched quadratic coupling to the 775 nm harmonic band in a single AlN microring and thus the formation of dual-band mode-locked combs. In the strong quadratic coupling regime where the χ (2) phase-matching window overlaps the pump mode, the pump-to-harmonic-comb conversion efficiency is optimized. However, the strong quadratic coupling also drastically modifies the Kerr comb generation dynamics and decreases the probability of soliton generation. By engineering the χ (2) phase-matching wavelength, we are able to achieve a balance between high conversion efficiency and high soliton formation rate under the available pump power and microring quality factors. Our numerical simulations confirm the experimental observations. These findings provide guidance on tailoring single-cavity dual-band coherent comb sources.
The University of Missouri Research Reactor (MURR ® ) is one of five U.S. high performance research reactors (USHPRR), plus one critical facility, that are actively collaborating with the National Nuclear Security Administration (NNSA) Material Management and Minimization (M 3 ) Reactor Conversion Program to convert from highly enriched uranium (HEU, ≥ 20 wt.% U-235) to low-enriched uranium (LEU, < 20 wt.% U-235) fuel. A new type of LEU fuel with very high density, based on an alloy of uranium and 10 weight percent molybdenum (U-10Mo), is expected to allow the conversion to LEU of USHPRR that have been found unable to be converted with previously qualified uranium silicide-aluminum (U 3 Si 2 -Al) dispersion fuel. MURR has been working with the USHPRR Reactor Conversion (RC) Pillar at Argonne National Laboratory to perform fuel element design and fuel cycle performance analyses, steady-state thermal hydraulics safety analyses, and accident safety analyses in preparation for the conversion of MURR and to support a preliminary Safety Analysis Report (SAR) for conversion to LEU fuel. In this work, Fluid-structure interaction (FSI) analysis at the fuel element level, as compared to the fuel plate level of the previous work. is performed which models all components of the MURR LEU fuel element, including fuel plates and the supporting structures e.g., side plates, end fittings, and combs. Therefore, the effect of supporting structures on the coolant flow distribution, the fuel plate deflection, and the resulting coolant channel gap reduction can be evaluated. In addition to the nominal element geometry and flow rate, the tolerances in the geometry dimensions of coolant channel and plate thickness, the effect of a comb on plate deflection, and the uncertainty of the flow rate per element are considered in this work. The effect of comb on plate displacement is quantified through two bounding cases: the case assuming a perfect bond between the comb and plates and the case neglecting the comb effect. Note that in this analysis, the FSI has been decoupled from the other structural effects caused by irradiation (e.g., swelling and irradiation creep). Assessment of combined effects is planned for a later stage of this project.
IPC J-STD-004B standard prescribes general requirements for the classification and testing of soldering flux for high qualify interconnections. This standard defines the classification of soldering materials through specifications of test methods and inspection criteria. The materials include liquid flux, paste flux, solderpaste flux, solder preform flux, and flux-cored solder. This research will use the proposed IPC-53 Surface Insulation Resistance (SIR) test patterns by means of an open comb (2D) and closed comb (3D to simulate a component over the comb pattern). The 2D open comb has uniformity of conductor spacing, sheet resistance, and flux outgassing. The 3D-closed comb simulates the effect of leadless or bottom-terminated components, which have non-uniform sheet resistance and flux outgassing. The response variables will include SIR testing and visual imaging. The objective is to investigate IPC test method improvements for characterizing soldering fluxes when using leadless components with narrow pad-to-pad spacing.
Microresonator-based soliton generation promises chip-scale integration of optical frequency combs for applications spanning from time keeping to frequency synthesis. Access to the soliton repetition rate is a prerequisite for those applications. While miniaturized cavities harness Kerr nonlinearity and enable terahertz soliton repetition rates, such high rates are not amenable to direct electronic detection. Here, we demonstrate hybrid Kerr and electro-optic microcombs using a lithium niobate thin film that exhibits both Kerr and Pockels nonlinearities. By interleaving the high-repetition-rate Kerr soliton comb with the low-repetition-rate electro-optic comb on the same waveguide, wide Kerr soliton mode spacing is divided within a single chip, allowing for direct electronic detection and feedback control of the soliton repetition rate. Our work establishes an integrated approach to electronically access terahertz solitons, paving the way for building chip-scale referenced comb sources.
The National Energy Technology Laboratory (NETL) and Toptica Photonics (Participant) will collaborate to demonstrate the application of a frequency-comb laser (dual-comb spectroscopy) in an optically accessible rotating detonation engine (RDE). RDEs are a next-generation energy conversion technology which are well-suited to hydrogen usage and have the potential to significantly increase the efficiency of gas turbine engine power cycles. However, critical information is needed about the high temperature and pressure detonation wave, which represents an extremely challenging diagnostic environment. Dual-comb spectroscopy can be used to characterize the pressure-broadened IR absorption features at MHz rates, providing information not possible with conventional tunable diode laser (TDL) technologies. This collaboration will, for the first time, demonstrate application of dual-comb spectroscopy within the combustion annulus of a hydrogen-air RDE. If successful, the data generated will help to accelerate commercialization of RDE technologies in support of decarbonizing our nation’s energy sector.
Resonantly stabilized radicals (RSR's) such as allylic radicals typically have bond energies exceeding 45 kcal/mol and are therefore reasonably long-lived up to quite high temperatures. Consequently, kinetics of the unimolecular dissociations and bimolecular reactions of these long-lived RSR's assume significance in high temperature chemically reacting systems such as in flames. Our recent analyses (J. Cho et al., Proc. Comb. Inst., 2022) of the uncertainty propagated by the energy transfer parameters for 1-methylallyl (1MA) dissociation to the laminar flame speed, indicates an intricate coupling between the kinetics of 1MA dissociation (chain propagation) and its reaction with H-atoms (chain-termination). Here, this work extends such analyses to other C 3 – C 5 allylic radicals: allyl, 2-methylallyl, 1,1-dimethylallyl, 1,2-dimethylallyl, and 1,3-dimethylallyl. Theoretical kinetics for the C 3 – C 4 allylic radicals were taken from prior literature studies (J.A. Miller et al., J. Phys. Chem., 2008; J. Cho et al., Proc. Comb. Inst., 2022; R.S. Tranter et al., Proc. Comb. Inst., 2017). Potential energy surfaces were newly computed for the dissociations of the larger C5 allylic radicals and the reactions of these radicals with H-atoms. These PES's were then used to calculate rate constants for the relevant unimolecular and bimolecular reactions. Energy transfer has a crucial role to play in these pressure-dependent reactions and therefore the present kinetics calculations relied on a-priori predictions of collisional energy transfer parameters to best characterize the branching between chain propagating unimolecular dissociations of these allylic radicals and chain terminating bimolecular reactions of these RSR's with H-atoms. Prompt dissociations are now established to be a universal feature of free radical dissociations. Here we have also characterized the propensity for prompt dissociations in these more-stable allylic RSR's and their role in combustion simulations.
We describe a technique for spectrograph stabilization useful when conventional mitigation techniques of vacuum tanks, thermal insulation, and laser frequency comb may be impractical, expensive, heavy, or bulky. This includes spectrographs on airborne platforms or mounted on telescopes where they suffer a changing gravity vector or other drifts. Placing a fixed-delay interferometer in series with a spectrograph forms an externally dispersed interferometer (EDI). This produces a uniform sinusoidal comb multiplying input spectrum, creating (through heterodyning) beats (moiré patterns). In Fourier space for low frequencies up to the comb frequency, the moiré generated signal counter-rotates to ordinary spectra under an unknown disperser wavenumber drift Δx. This generates a large negative feedback signal useful in a conceptual control loop, to converge rapidly to a stable spectrum and yield Δx. A modified EDI data analysis algorithm (“crossfading”) combines frequency-weighted moiré with conventional spectrum to cancel net output spectrum reaction to Δx. Needing only a single-delay, this is a practical improvement over prior crossfading analyses requiring multiple delays. We test crossfading on ThAr data near 4850 cm−1 taken on Hale telescope in an earlier project. In a single pass, we reduce drift 20 times. Using seven iterations, we reduce 0.5 cm−1 (31 km/s Doppler equivalent) drift to 4×10−7 cm−1 (2.5 cm/s). The interferometer delay can wander, because linearity of phase versus wavenumber interpolates science features between bracketing calibrating spectral references. Second, mathematically reversing the heterodyning effect doubles effective spectral resolution without changing disperser slit.
Excalibur is a nonparametric, hierarchical framework for precision wavelength calibration of spectrographs. It is designed with the needs of extreme-precision radial-velocity (EPRV) instruments in mind, which require calibration or stabilization to better than 10{sup −4} pixels. Instruments vary along only a few dominant degrees of freedom, especially EPRV instruments that feature highly stabilized optical systems and detectors. Excalibur takes advantage of this property by using all calibration data to construct a low-dimensional representation of all accessible calibration states for an instrument. Excalibur also takes advantage of laser-frequency combs or etalons, which generate a dense set of stable calibration points. This density permits the use of a nonparametric wavelength solution that can adapt to any instrument or detector oddities better than parametric models, such as a polynomial. We demonstrate the success of this method with data from the Extreme Precision Spectrograph (EXPRES), which uses a laser-frequency comb. When wavelengths are assigned to laser comb lines using excalibur, the rms of the residuals is about one-fifth that of wavelengths assigned using polynomial fits to individual exposures. Radial-velocity measurements of HD 34411 show a reduction in rms scatter over a 10 month time baseline from 1.17 to 1.05 m s{sup −1}.
Integrating femtosecond lasers with electron microscopies has enabled direct imaging of transient structures and morphologies of materials in real time and space. Here, we report the development of a laser-free ultrafast electron microscopy (UEM) offering the same capability but without requiring femtosecond lasers and intricate instrumental modifications. We create picosecond electron pulses for probing dynamic events by chopping a continuous beam with a radio frequency (RF)–driven pulser with the pulse repetition rate tunable from 100 MHz to 12 GHz. As a first application, we studied gigahertz electromagnetic wave propagation dynamics in an interdigitated comb structure. We reveal, on nanometer space and picosecond time scales, the transient oscillating electromagnetic field around the tines of the combs with time-resolved polarization, amplitude, and local field enhancement. This study demonstrates the feasibility of laser-free UEM in real-space visualization of dynamics for many research fields, especially the electrodynamics in devices associated with information processing technology.
Random copolymers of poly(4-vinylpyridine) and polyisoprene were synthesized, and subsequently quaternized with 1-alkylbromides. The number of carbons on the pendant side-chain of the resultant comb-shaped polymer, n, ranged from 2-8. The comb-shaped polymers were crosslinked employing thiol-ene chemistry to give mechanically robust ion conducting membranes. Analysis by wide and medium-angle X-ray scattering show three morphology regimes that are dependent on the number of carbons on the pendant side-chains. When n = 2, ionomer cluster morphology was dominant, when n = 8 backbone-backbone morphology was dominant, and when n = 3-6, the membrane showed a coexistence of both ionomer cluster and backbone-backbone morphologies. Evaluation of the water uptake of the membranes showed a maximum water uptake per cation of 9.5 when n = 5 at 95% relative humidity (RH) and 60 degrees C. Finally, conductivity of the samples characterized by electrochemical impedance spectroscopy showed bromide conductivity as high as 110 mS/cm when n = 3 at 95% RH and 90 degrees C.