Space vacuum investigations

Inaccessible-Non Repairable- Costly: The meaning of these words is absolute in the event of a complete failure of an orbiting spacecraft. Adequate design, or rather, minimizing chance of failure, challenges all scientists and engineers. Where experience has not been developed, the risk involved in a new application must be weighed against the consequence of a design failure. In space work, the spectrum of consequence is extremely wide. It ranges from loss of scientific data on one hand, to loss of life on the other.. There is little question that knowledge of the space environment and its effects must be determined to produce reliable spacecraft. Tests to prove the design must be performed with equipment capable of simulating the effects of the environment in which the design is to operate. This does not necessarily mean that the natural environment must be duplicated. The degree of environmental simulation that should be achieved depends primarily upon the significance of the physical effects it causes. The purpose of space vacuum simulation in an environmental test program should be accurately conceived and the testing phased to obtain maximum information from the limited samples available for test. This discussion is confined to some of the factors involved in simulating the effects of space vacuum environment. This survey is by no means complete, but will touch on some of the highlights in this field: 1. A description of the environment 2. The level of simulation necessary to evaluate its effects 3. Test equipment capability 4. Experience in test 5. Experience in orbit 6. Observations & future emphasis

VACUUM EFFECT↗

Partial discharge testing under direct voltage conditions

DC partial discharge (PD) (corona) testing is performed using a multichannel analyzer for pulse storing, and data is collected during increase of voltage and at quiescent voltage levels. Thus high voltage ceramic disk capacitors were evaluated by obtaining PD data interspersed during an accelerated life test. Increased PD activity was found early in samples that later failed catastrophically. By this technique, trends of insulation behavior are revealed sensitively and nondestructively in high voltage dc components.

Bever, R. S.↗

High voltage design guide. Volume 5: Spacecraft

This report supplies the technical background and design techniques needed by an engineer who is designing electrical insulation for high-voltage, high-power components, equipment, and systems on spacecraft. The data in this volume is in addition to the material in Volume 4 of the final report "High Voltage Design Guide: Aircraft' which is common to the electrical insulation design for both aircraft and spacecraft equipment. The common data includes testing, tracking, partial discharges and corona. Unique material involves the semi vacuum environment, spacecraft charging, and multipactor.

W G Dunbar↗

The Laser Atmospheric Wind Sounder (LAWS) Phase 2 Preliminary Laser Design

The requirements for the Laser Atmospheric Wind Sounder (LAWS) were determined from system considerations and are summarized in tabular form. The laser subsystem provides for the generation and frequency control of two beams, the transmit high power and local oscillator beams, which are delivered to the optical and receiver subsystems, respectively. In our baseline approach, the excitation of the gain section is achieved by a self-sustaining uv-(corona) preionized discharge. Gas is recirculated within the laser loop using a transverse flow fan. An intra-flow-loop heat exchanger, catalyst monolith, and acoustic attenuators condition the gas to ensure uniform energy output and high beam quality during high pulse repetition rate operation. The baseline LAWS laser pulse temporal profile as calculated by in-house laser codes is given in graphical form.

Lawrence, T. Rhidian↗

Modular power conversion system with galvanic insulation

A modular power conversion system is provided which includes a plurality of building blocks comprised of transformers and power conversion bridges, and a high frequency AC link that transfers power and provides galvanic isolation between the building blocks. The high frequency link includes an insulating tube separating an AC link conductor and the building blocks. The insulating tube is further provided with conductive or semiconductive layers on its inner and outer surfaces for referencing them to the electric potentials of the adjacent conductors and windings, thereby placing the high electric fields substantially directly across the tube and reducing electric fields and partial discharge or corona in the adjoining space or media. The building blocks may be arranged in multiple stacks for DC or AC interface, preferably with neutral or lower voltage connections at the outer edges of the stacks and higher voltage terminals at the centers of the stack.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Accelerated aging test results for aerospace wire insulation constructions

Several wire insulation constructions were evaluated with and without continuous glow discharges at low pressure and high temperature to determine the aging characteristics of acceptable wire insulation constructions. It was known at the beginning of the test program that insulation aging takes several years when operated at normal ambient temperature and pressure of 20 C and 760 torr. Likewise, it was known that the accelerated aging process decreases insulation life by approximately 50% for each 10 C temperature rise. Therefore, the first phases of the program, not reported in these test results, were to select wire insulation constructions that could operate at high temperature and low pressure for over 10,000 hours with negligible shrinkage and little materials' deterioration.The final phase of the program was to determine accelerated aging characteristics. When an insulation construction is subjected to partial discharges the insulation is locally heated by the bombardment of the discharges, the insulation is also subjected to ozone and other deteriorating gas particles that may significantly increase the aging process. Several insulation systems using either a single material or combinations of teflon, kapton, and glass insulation constructions were tested. All constructions were rated to be partial discharge and/or corona-free at 240 volts, 400 Hz and 260 C (500 F) for 50, 000 hours at altitudes equivalent to the Paschen law. Minimum partial discharge aging tests were preceded by screening tests lasting 20 hours at 260 C. The aging process was accelerated by subjecting the test articles to temperatures up to 370 C (700 F) with and without partial discharges. After one month operation with continuous glow discharges surrounding the test articles, most insulation systems were either destroyed or became brittle, cracked, and unsafe for use. Time with space radiation as with partial discharges is accumulative.

Dunbar, William G.↗

Evaluating the impact of air terminal geometry on lightning intercept efficacy under a strong background electric field

A comparative analysis of the attachment efficacy of sharpened vs blunted air terminals under a strong background DC electric field, similar to conditions found in naturally occurring lightning events, is presented. Testing was conducted using an oil-free, 17-stage, 1.4 MV bipolar Marx generator with a biased discharge plane that emulated the conditions found prior to the lightning return stroke. The biased discharge plane allowed the introduction of a strong DC electric field and subsequent corona formation on a time scale much longer than the brief duration over which the downward leader propagates. Initial observations indicate that despite a higher background electric field at the sharpened terminals, leading to pre-discharge corona formation where none is seen on the blunt terminal, both the sharpened and blunted terminals exhibit similar attachment probabilities during discharge events, with some discharge events attaching to both terminals.

54 ENVIRONMENTAL SCIENCES↗

Optimizing Insulation Design for Transformers in Medium Voltage Power Conversion Systems

Medium-frequency transformers (MFTs) play a crucial role in medium-voltage (MV) solidstate transformer (SST) systems, particularly in extreme fast charging applications. Achieving partial discharge (PD)-free operation while maintaining high power density is a significant challenge due to the high electric field (E-field) stresses inherent in MV applications. This dissertation focuses on the insulation design and optimization of MFTs used in both the main power electronics circuits and auxiliary power supplies. The study begins with an overview of insulation testing methodologies, including high potential tests, basic insulation level tests, and PD tests, which are critical for evaluating MFT insulation reliability. Given the importance of PD-free operation for long-term reliability, particular emphasis is placed on understanding PD mechanisms, including void, corona, and surface discharge, and their mitigation strategies. A high voltage isolated auxiliary power supply is then introduced, utilizing a gapped transformer encapsulated in silicone gel. This design achieves PD-free insulation up to 18 kV RMS while maintaining low coupling capacitance to minimize common-mode current. The proposed solution ensures reliable operation in MV environments and offers a scalable approach for auxiliary power in cascaded SST architectures. To improve MFT insulation in main power conversion circuits, a novel structure is developed using polypropylene sheets and potting compounds to create a void-free air gap, effectively mitigating E-field intensity. A prototype transformer with this insulation structure is built and achieves PD-free operation up to 30 kV RMS. This design is experimentally validated in a resonant converter operating at 46 kW, demonstrating its feasibility for MV SST applications. Further optimization is implemented to enhance MFT performance for dual-active-bridge(DAB) converters by integrating a semiconductive shielding layer within the insulation structure. This shielding layer improves the magnetic coupling coefficient while effectively confining the E-field within high insulation materials, thereby reducing eddy current losses. The optimized MFT achieves PD-free operation at 12.6 kV RMS and is successfully tested in a DAB converter operating at 43 kW, which meets the insulation requirements for a 13.2 kV SST system. This dissertation advances MFT insulation design by introducing and experimentally validating novel approaches that improve high voltage insulation while optimizing magnetic coupling and manufacturability. The proposed insulation structures enable PD-free operation while minimizing insulation material usage and simplifying assembly, making them ideal for high power, high voltage applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrical Auxiliary Power Unit (EAPU) Corona Design Guideline

This document is the result of a collaborative effort between NASA's Johnson Space Center, Marshall Space Flight Center, Glenn Research Center, and the United States Air Force Research Laboratory at Wright Patterson AFB in support of the Space Shuttle Orbiter Upgrades Program, specifically the Electric Auxiliary Power Unit Program. This document is intended as a guideline for design applications for corona and partial discharge avoidance and is not a requirements specification instrument.

Hall, David K.↗

High Voltage Power Supply Design Guide for Space

This book is written for newcomers to the topic of high voltage (HV) in space and is intended to replace an earlier (1970s) out-of-print document. It discusses the designs, problems, and their solutions for HV, mostly direct current, electric power, or bias supplies that are needed for space scientific instruments and devices, including stepping supplies. Output voltages up to 30kV are considered, but only very low output currents, on the order of microamperes. The book gives a brief review of the basic physics of electrical insulation and breakdown problems, especially in gases. It recites details about embedment and coating of the supplies with polymeric resins. Suggestions on HV circuit parts follow. Corona or partial discharge testing on the HV parts and assemblies is discussed both under AC and DC impressed test voltages. Electric field analysis by computer on an HV device is included in considerable detail. Finally, there are many examples given of HV power supplies, complete with some of the circuit diagrams and color photographs of the layouts.

Bever, Renate S.↗

Feasibility of Micro-Multilayer Multifunctional Electrical Insulation (MMEI) System for High Voltage Applications

The newly patented micro-multilayer multifunctional electrical insulation (MMEI) system was developed for future electric aircraft applications which critically require lightweight but high voltage (HV), high temperature, and corona or partial discharge (PD) resistant insulation. During the initial development stages, the concept and practicability of the MMEI system were successfully validated with its exceptionally high dielectric breakdown voltages. The multilayer structures were optimized in terms of material type, individual layer thickness, and overall layer configuration along with potential mechanisms identified for its superior performance. Subsequently, scalability, manufacturability, and commercial applicability of the MMEI system were demonstrated with the 1 meter long, 3-phase HV, high power (HP) bus bar prototypes. Two prototypes, one with the conventional SOA insulation system including Mica sheet and the other with an optimized MMEI, were designed, fabricated, and tested successfully. Both prototypes passed both HiPot and PD tests up to the highest test voltage available, 15 kVAC, although the latter showed a slight increase in PD activities at 12.5 kV. However, the prototype with MMEI was 15% lighter or 12% thinner than the other one. Current efforts to significantly enhance the PD resistance of the MMEI system by employing semiconductive shielding layers, which can be also multifunctional, e.g., electromagnetic interference shielding, moisture blocking, heat dissipation, for various HV applications are also discussed in this paper.

Novel Electrical Insulation↗

Feasibility of Micro-Multilayer Multifunctional Electrical Insulation (MMEI) System for High Voltage Applications

The newly patented micro-multilayer multifunctional electrical insulation (MMEI) system was developed for future electric aircraft applications which critically require lightweight but high voltage (HV), high temperature, and corona or partial discharge (PD) resistant insulation. During the initial development stages, the concept and practicability of the MMEI system were successfully validated with its exceptionally high dielectric breakdown voltages. The multilayer structures were optimized in terms of material type, individual layer thickness, and overall layer configuration along with potential mechanisms identified for its superior performance. Subsequently, scalability, manufacturability, and commercial applicability of the MMEI system were demonstrated with the 1 meter long, 3-phase HV, high power (HP) bus bar prototypes. Two prototypes, one with the conventional SOA insulation system including Mica sheet and the other with an optimized MMEI, were designed, fabricated, and tested successfully. Both prototypes passed both HiPot and PD tests up to the highest test voltage available, 15 kVAC, although the latter showed a slight increase in PD activities at 12.5 kV. However, the prototype with MMEI was 15% lighter or 12% thinner than the other one. Current efforts to significantly enhance the PD resistance of the MMEI system by employing semiconductive shielding layers, which can be also multifunctional, e.g., electromagnetic interference shielding, moisture blocking, heat dissipation, for various HV applications are also discussed in this paper.

Novel Electrical Insulation↗

Technologies and Operations for High Voltage Corona Detection with UAVs

Autonomous UAV transmission line inspection served as a reference mission for NASA demonstration of UAV deployment for economic benefit; this paper reports corona sensing advances in development of that reference mission. Unmanned aerial vehicles can serve as a platform for autonomous sensing and location of high voltage coronal discharge. Simple processing of commercial corona camera imagery can automate discharge localization and documentation. Inexpensive ultraviolet point sensors can sense discharge when carried close to the defect with a UAV. Augmented with a parabolic mirror, point sensor range can be increased to a safe inspection standoff distance, at the cost of a narrowed field of view. Results from a test flight of an augmented UV sensor are described. The imaging approach is superior in sensitivity and acquisition time, while the point sensor approach has superior size, weight, cost and durability advantages.

Moore, Andrew J.↗

Corona-vacuum failure mechanism test facilities

A nondestructive corona-vacuum test facility for testing high-voltage power system components has been developed using commercially available hardware. The facility simulates operating temperature and vacuum while monitoring coronal discharges with residual gases. Corona threshold voltages obtained from statorette tests with various gas-solid dielectric systems and comparison with calculated data support the following conclusions: (1) air gives the highest corona threshold voltage and helium the lowest, with argon and helium-xenon mixtures intermediate; (2) corona threshold voltage increases with gas pressure; (3) corona threshold voltage for an armature winding can be accurately calculated by using Paschen curves for a uniform field; and (4) Paschen curves for argon can be used to calculate the corona threshold voltage in He-Xe mixtures, for which Paschen curves are unavailable.-

Lalli, V. R.↗

Development of compact excimer lasers for remote sensing

The capabilities of excimer lasers for remote sensing applications are illustrated in a discussion of the development of a compact tunable XeCl excimer laser for the detection of atmospheric OH radicals. Following a brief review of the operating principles and advantages of excimer lasers, measurements of the wavelength dependence of the net small signal gain coefficient of a discharge excited XeCl laser are presented which demonstrate the overlap of several absorption lines of the A-X(0,0) transition of OH near 308 nm with the wavelengths of the XeCl laser. A range of continuous narrow bandwidth tunability of from 307.6 to 308.4 nm with only a 30 percent variation in output is reported for an XeCl laser used as a double-pass amplifier for a frequency-doubled dye laser, and measurements demonstrating the detection of laser-induced fluorescence from OH in a methane-oxygen flame are also noted. The design of an oscillator-amplifier excimer system comprising a corona-preionized, transverse-discharge oscillator and amplifier is then presented. Output energies of 12-15 mJ have been achieved in the regions where injection locking was established, with energies of 8-10 mJ elsewhere.

Laudenslager, J. B.↗

Ionization waves in low-current dc discharges in noble gases obtained with a hybrid kinetic-fluid model

A hybrid kinetic-fluid model is used to study ionization waves (striations) in a low-current plasma column of dc discharges in noble gases. Coupled solutions of a kinetic equation for electrons, a drift-diffusion equation for ions, and a Poisson equation for the electric field are obtained to clarify the nature of plasma stratification in the positive column. A simplified two-level excitation-ionization model is used for the conditions when the nonlinear effects due to stepwise ionization, gas heating, and Coulomb interactions among electrons are negligible. It is confirmed that the nonlocal effects are responsible for the formation of moving striations in dc discharges at low plasma densities and low values of pR (the product of gas pressure and tube radius). Here, the calculated properties of self-excited waves of S–, P–, and R types in neon and S type in argon agree with available experimental data. The reason for helium plasma stability to stratification is clarified. It is shown that sustaining stratified plasma is more efficient than striation-free plasma when the ionization rate is a nonlinear function of the electric field. However, the nonlinear dependence of the ionization rate on the electric field is not required for plasma stratification. Striations of S–, P–, and R types in neon exist with minimal or no ionization enhancement. Effects of the column length and plasma density on the wave properties are demonstrated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗