Search NASA⌕ Search

SEARCH · Search NASA

Results for “COUNTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

An imaging gas scintillation proportional counter for the detection of subkiloelectron-volt X-rays

A large area imaging gas scintillation proportional counter (IGSPC) was constructed for use in X-ray astronomy. The IGSPC consists of a gas scintillation proportional counted (GSPC) with a micron polyprotylene window coupled to a multiwire proportional counter (MWPC) via a calcium fluoride window. Over a sensitive area of 21 cu cm the instrument has a measured energy resolution of 17.5% (FWHM) and 1.9 mm (FWHM) spatial resolution at 1.5 keV.

Hailey, C. J.↗

Technology and benefits of aircraft counter rotation propellers

Results are reported of a NASA sponsored analytical investigation into the merits of advanced counter rotation propellers for Mach 0.80 commercial transport application. Propeller and gearbox performance, acoustics, vibration characteristics, weight, cost and maintenance requirements for a variety of design parameters and special features were considered. Fuel savings in the neighborhood of 8 percent relative to single rotation configurations are feasible through swirl recovery and lighter gearboxes. This is the net gain which includes a 5 percent acoustic treatment weight penalty to offset the broader frequency spectrum noise produced by counter rotation blading.

Strack, W. C.↗

X-ray observations of 4U 1626-67 by the monitor counter on the Einstein /HEAO 2/ observatory

The pulsing X-ray source 4U 1626-67 was observed with the Monitor Proportional Counter (MPC) on board the Einstein X-Ray Observatory on three occasions in early 1979. The MPC is a sealed, argon-filled proportional counter with a 1.5 mil beryllium window and is coaligned with the X-ray telescope on board the observatory. The spectral data spanning the energy range from 1.1 to 21 keV are divided into eight logarithmically spaced energy channels which integrate for 2.56 s. The Time Interval Processor (TIP) circuitry of the MPC measures time intervals between events to within 1 microsecond or 1.6%, whichever is larger, for a count rate dependent fraction of all events in all eight energy channels. It is found that in the energy range from 1 to 21 keV, the spectrum and 7.7 s pulse shape of 4U 1626-67 are variable on a time scale of minutes. The pulse shape variations correlate in a complex way with the intensity variations in this source.

Elsner, R. F.↗

Calibration of an aerogel counter of index 1.1 at the Bevalac

The counter, which is exposed to sea level muons and to a beam of relativistic Mn-55, is 6 cm thick and approximmately 60 cm in diameter; it is viewed by twelve 12.7-cm-diameter photomultipliers. It comprises a mosaic with 48 aerogel pieces whose refractive indices are approximately 1.1. It is pointed out that a relativistic muon produces typically 23 + or - 4 photo-electrons. The light yield, which is mapped as a function of position, has an r.m.s. variation of less than 1 percent per cm. An analysis of the light yield suggests that absorption is important at short wavelengths. The calibration reveals that the light yield and uniformity of the counter are sufficient to determine particle velocity in the gamma range from 2.4 to 3.1.

Rasmussen, I. L.↗

Frequency-Discriminating Acoustic-Event Counter

Broadband events rejected. Acoustic-event counter discriminates against signals that simultaneously exceed preset amplitude thresholds in both low and high-frequency bands of its spectrum. Counter acts as spectral analyzer for mechanical vibrations. In combination with broadband acoustic transducer discriminates between signals and noise in acoustical destructive or nondestructive testing, vibration monitoring for machinery, burglar alarms, and other monitoring/warning systems.

Sugg, F. E.↗

Filter induced errors in laser anemometer measurements using counter processors

Simulations of laser Doppler anemometer (LDA) systems have focused primarily on noise studies or biasing errors. Another possible source of error is the choice of filter types and filter cutoff frequencies. Before it is applied to the counter portion of the signal processor, a Doppler burst is filtered to remove the pedestal and to reduce noise in the frequency bands outside the region in which the signal occurs. Filtering, however, introduces errors into the measurement of the frequency of the input signal which leads to inaccurate results. Errors caused by signal filtering in an LDA counter-processor data acquisition system are evaluated and filters for a specific application which will reduce these errors are chosen.

Oberle, L. G.↗

Fast scintillation counter preamplifier for the observation of Linsley effect

A fast preamplifier circuit has been designed and thoroughly tested for the purpose of observing the air shower arrival directions including the Linsley effect. The circuit intends to eliminate the time jitter due to variation of scintillation counter signal amplitudes. It assumes that the output signals from one counter system have the same rise time. On this basis, error arising from time jitter is removed by voltage discrimination at about half signal amplitudes. Detailed description of the circuit is reported.

Ng, L. K.↗

An instrument employing electronic counters and an emulsion chamber for studying heavy cosmic ray interactions (JACEE-3)

A JACEE-3 instrument was flown on a balloon in June 1982 for 6.1 sq m sr hr exposure at an average atmospheric depth of 5 gm/sq cm in order to study the cosmic ray spectra, composition, and interactions above 1 TeV. The nucleus-nucleus interactions were studied above 20 GeV/amu from z = 6 to z = 26. The electronic counters contained gas Cerenkov structures with a 1.0-cm thick lead glass and a 1.27-cm thick Teflon radiator. A comparison to the instrument prototype is made. Based on the electronic counter event data, the finding efficiency of the hodoscope is noted to be near 100 percent for z greater than or equal to 22. A comparison is made between the hodoscope-predicted position and track found at P3 in an emulsion chamber.

Austin, R. W.↗

Filter induced errors in laser anemometry using counter-processor

Simulations of laser Doppler anemometer (LDA) systems have focused primarily on noise studies or biasing errors. Another possible source of error is the choice of filter types and filter cutoff frequencies. Before it is applied to the counter portion of the signal processor, a Doppler burst is filtered to remove the pedestal and to reduce noise in the frequency bands outside the region in which the signal occurs. Filtering, however, introduces errors into the measurement of the frequency of the input signal which leads to inaccurate results. Errors caused by signal filtering in an LDA counter-processor data acquisition system are evaluated and filters for a specific application will reduce these errors are chosen.

Oberle, L. A.↗

A VLSI architecture of a binary updown counter

A pipeline binary updown counter with many bits is developed which can be used in a variety of applications. One such application includes the design of a digital correlator for very long baseline interferometry (VLBI). The advantage of the presently conceived approach over the previous techniques is that the number of logic operations involved in the design of the binary updown counter can be reduced substantially. The architecture design using these methods is regular, simple, expandable and, therefore, naturally suitable for VLSI implementation.

Reed, I. S.↗

A method for using a time interval counter to measure frequency stability

It is shown how a commercial time interval counter can be used to measure the relative stability of two signals that are offset in frequency and mixed down to a beat note of about 1 Hz. To avoid the dead-time problem, the counter is set up to read the time interval between each beat note upcrossing and the next pulse of a 10 Hz reference pulse train. The actual upcrossing times are recovered by a simple algorithm whose outputs can be used for computing residuals and Allan variance. A noise floor-test yielded a delta f/f Allan deviation of 1.3 times 10 to the minus 9th power/tau relative to the beat frequency.

Greenhall, C. A.↗

A fluorescent gated proportional counter for X-ray astronomy

The development of a position-sensitive proportional counter having a large drift volume is reported. It incorporates a fluorescent gating technique which results in a large improvement in background rejection over conventional proportional counters, and in addition offers the benefit of enhanced energy resolution (predicted to be about 3 percent at 40 keV) above the K shell of Xe.

Ramsey, B. D.↗

Three-dimensional unsteady Euler solutions for propfans and counter-rotating propfans in transonic flow

An Euler code designed for computing the unsteady, three-dimensional, transonic flow about single-rotating and counter-rotating propfans using dynamic blocked-grids is presented. The algorithm is a finite volume, flux-split, upwind, implicit scheme and solves the equations which have been written in a time-dependent curvilinear coordinate system. Relative motion of the blades for counter-rotating configurations is handled by requiring that grid lines be aligned after each discrete rotation of fore and aft rotor grid blocks. The method by which information is passed across block interfaces, as well as how downstream characteristic outflow boundary conditions which enforce simple radial equilibrium are implemented, is discussed. Comparisons of computed flow-field parameters and propfan performance with experimental data indicate good overall agreement between predictions and measurements.

Whitfield, D. L.↗

A panel method for counter rotating propfans

A time domain source-doublet surface paneling method is developed for analyzing the unsteady loads on counter rotating propellers in incompressible irrotational flow. A scheme for treating the blade-wake interaction problem is described. Sample results for single rotation propellers are given, with comparisons to alternate theories and experiment. Finally, some preliminary results for quasi-steady and fully unsteady loads on counter rotating systems are presented.

Williams, M. H.↗

VLSI Architecture Of A Binary Up/Down Counter

Identical stages contain relatively-few logic gates. New algorithm simplifies design of binary up/down counter. Design suitable for very-large-scale integrated circuits. Contains simple "pipeline" array of identical cells. Programmable logic unit converts increment and decrement input signals to "U" and "D" signals required by algorithm of counter.

Hsu, In-Shek↗

Primary instabilities and bicriticality in flow between counter-rotating cylinders

The primary instabilities and bicritical curves for flow between counter-rotating cylinders have been computed numerically from the Navier-Stokes equations assuming axial periodicity. The computations provide values of the Reynolds numbers, wavenumbers, and wave speeds at the primary transition from Couette flow for radius ratios from 0.40-0.98. Particular attention has been focused on the bicritical curves that separate (as the magnitude of counter-rotation is increased) the transitions from Couette flow to flows with different azimuthal wavenumbers m and m + 1. This lays the foundation for further analysis of nonlinear mode interactions and pattern formation occurring along the bicritical curves and serves as a benchmark for experimental studies. Preliminary experimental measurements of transition Reynolds numbers and wave speeds presented here agree well with the computations from the mathematical model.

Langford, W. F.↗

Gas mixtures for X-ray proportional counters

Results are presented which detail the performance of proportional counters when filled with a wide variety of argon- and xenon-based gas mixtures. It is shown that alternative gas mixtures can offer considerable advantages in the counters. The mixtures of argon plus 10 percent propane and xenon plus 10 percent propylene look particularly attractive in terms of operating voltage and energy resolution. The quench gas CO2 returns the poorest results in all areas except aging.

Ramsey, B. D.↗

A method for using a time interval counter to measure frequency stability

It is shown how a commercial time interval counter can be used to measure the relative stability of two signals that are offset in frequency and mixed down to a beat note of about 1 Hz. To avoid the dead-time problem, the counter is set up to read the time interval between each beat note upcrossing and the next pulse of a 10 Hz reference pulse train. The actual upcrossing times are recovered by a simple algorithm whose outputs can be used for computing residuals and Allan variance. A noise floor-test yielded a delta f-f Allan deviation of 1.3 times 10 to the minus 9th power/tau relative to the beat frequency.

Greenhall, Charles A.↗