Search NASA⌕ Search

SEARCH · Search NASA

Results for “CT images”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Advancing the Frontiers of Deep Learning for Low-Dose 3D Cone-Beam CT Reconstruction

X-ray computed tomography (CT) is an important noninvasive medical imaging modality for studying the structural details of internal organs. Image reconstruction in CT is an inverse problem of recovering an object's internal structure from the absorption profile of X-ray beams (sinogram) measured using a detector. The classical variational approach for CT reconstruction minimizes an energy functional using an appropriate iterative algorithm. Motivated by the success of deep learning (DL), researchers have begun to leverage training data and enhanced computing capabilities in recent years to produce high-fidelity reconstructed images. Nonetheless, much of the academic research in DL algorithms for CT has focused primarily on the two-dimensional setting (with simplified forward operators and noise model) for proofs-of-concept, and a comprehensive benchmarking of various classical and data-driven CT reconstruction approaches has not beenundertaken. The key objective of our CT reconstruction grand challenge was to promote methodological advancements for both classical and DL-based approaches for clinical CT with a reasonably accurately simulated 3D CT forward operator and noise model. We have utilized the publicly available LIDC-IDRI dataset and simulated sinograms and FDK images corresponding to two dose levels (clinical- and low-dose, constituting two tracks of the challenge) starting from the normal-dose images as the ground truth. In this paper, we summarize the motivation, context, and results of our challenge, and highlight the future research directions in DL for clinical CT.

X-ray tomography↗

State 16-2 Well

CT scans, images, and MSCL data to accompany the State 16-2 well

Cane Creek Shale↗

Half-cell electrode assessments of a crossover-tolerant direct methanol fuel cell with a platinum group metal-free cathode

In this work, a platinum group metal- free (PGM-free) Fe-N-C oxygen reduction reaction (ORR) catalyst derived from metal organic framework precursors (Fe-MOF) is evaluated at the cathode side of a direct methanol fuel cell (DMFC). A wide range of methanol concentrations were used, and the performance of the DMFC using air was evaluated and compared to a commercial Pt/C cathode. We conducted our tests with a custom, integrated H 2 reference electrode that separately provided the anode and cathode overpotentials. This allowed us to perform a Tafel analysis on both electrodes and understand the dominant polarizations involved at the PGM-free cathode and the PtRu/C anode. Overall, we achieved a high cell performance using a Fe-N-C based catalyst under liquid methanol and air operation with a peak power density of 111 mW/cm 2 , where the cathode presented a markedly larger contribution to the voltage loss versus the anode. Additionally, we used nanoscale X-ray computed tomography (nano-CT) to image the Fe-N-C cathode and investigate the ionomer and pore size distributions allowing us to identify areas of improvement for catalyst layer fabrication.

30 DIRECT ENERGY CONVERSION↗

A wide-field micro-computed tomography detector: micron resolution at half-centimetre scale

Ideal three-dimensional imaging of complex samples made up of micron-scale structures extending over mm to cm, such as biological tissues, requires both wide field of view and high resolution. For existing optics and detectors used for micro-CT (computed tomography) imaging, sub-micron pixel resolution can only be achieved for fields of view of <2 mm. This article presents a unique detector system with a 6 mm field-of-view image circle and 0.5 µm pixel size that can be used in micro-CT units utilizing both synchrotron and commercial X-ray sources. A resolution-test pattern with linear microstructures and whole adult Daphnia magna were imaged at beamline 8.3.2 of the Berkeley Advanced Light Source. Volumes of 10000 × 10000 × 7096 isotropic 0.5 µm voxels were reconstructed over a 5.0 mm × 3.5 mm field of view. Measurements in the projection domain confirmed a 0.90 µm measured spatial resolution that is largely Nyquist-limited. This unprecedented combination of field of view and resolution dramatically reduces the need for sectional scans and computational stitching for large samples, ultimately offering the means to elucidate changes in tissue and cellular morphology in the context of larger, whole, intact model organisms and specimens. This system is also anticipated to benefit micro-CT imaging in materials science, microelectronics, agricultural science and biomedical engineering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hydro-mechanical behavior of heated bentonite buffer for geologic disposal of high-level radioactive waste: A bench-scale X-ray computed tomography investigation

The behavior of heated bentonite buffer is critical for the security and long-term performance of a geological repository for high-level radioactive waste (HLW). While laboratory column experiments have been conducted to investigate compacted bentonite and coupled THMC (thermal-hydro-mechanical and chemical) processes for a moderate temperature range of up to 100 °C, data for a higher temperature range are limited. Understanding bentonite behavior and coupled THMC processes under higher temperatures (e.g., up to 200 °C) could allow for a more economic repository design and would expand the data and knowledge base for more reliable modeling. In this study, a bench-scale experiment was conducted in a compacted bentonite column experiencing both heating up to 200 °C in the center and hydration from a sand-clay boundary surrounding the column. During the experiment run for 1.5 years, frequent X-ray computed tomography (CT) scanning of bentonite provided insights into the spatiotemporal evolution of (1) hydration/dehydration, (2) clay swelling/shrinkage, (3) displacement, and (4) mineral precipitation. After the experiment, a comprehensive post-dismantling characterization of bentonite samples was conducted. Results showed that the bentonite hydration was axi-symmetrical despite the initial heterogeneity due to packing, confirming the ability of bentonite to seal fast flow/transport paths. Further, compared to a non-heated control experiment, the heated column showed greater CT density variations along the radial distance, indicating that homogenization of bentonite might be more difficult if a temperature gradient is maintained in the repository. Precipitation of an anhydrite layer occurred in the inner hot zone, pointing to potential concerns about salt precipitation causing canister corrosion. Ultimately, the experiments provided a high-resolution window into the strongly dynamic and coupled behavior of bentonite exposed to heating, hydration and swelling, which will be valuable for improving modeling of coupled processes, especially for the early state of a HLW repository.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Genetic interactions between polycystin-1 and Wwtr1 in osteoblasts define a novel mechanosensing mechanism regulating bone formation in mice

Molecular mechanisms transducing physical forces in the bone microenvironment to regulate bone mass are poorly understood. Here, we used mouse genetics, mechanical loading, and pharmacological approaches to test the possibility that polycystin-1 and Wwtr1 have interdependent mechanosensing functions in osteoblasts. We created and compared the skeletal phenotypes of control Pkd1 flox/+ ;Wwtr1 flox/+ , Pkd1 Oc-cKO , Wwtr1 Oc-cKO , and Pkd1/Wwtr1 Oc-cKO mice to investigate genetic interactions. Consistent with an interaction between polycystins and Wwtr1 in bone in vivo, Pkd1/Wwtr1 Oc-cKO mice exhibited greater reductions of BMD and periosteal MAR than either Wwtr1 Oc-cKO or Pkd1 Oc-cKO mice. Micro-CT 3D image analysis indicated that the reduction in bone mass was due to greater loss in both trabecular bone volume and cortical bone thickness in Pkd1/Wwtr1 Oc-cKO mice compared to either Pkd1 Oc-cKO or Wwtr1 Oc-cKO mice. Pkd1/Wwtr1 Oc-cKO mice also displayed additive reductions in mechanosensing and osteogenic gene expression profiles in bone compared to Pkd1 Oc-cKO or Wwtr1 Oc-cKO mice. Moreover, we found that Pkd1/Wwtr1 Oc-cKO mice exhibited impaired responses to tibia mechanical loading in vivo and attenuation of load-induced mechanosensing gene expression compared to control mice. Finally, control mice treated with a small molecule mechanomimetic, MS2 that activates the polycystin complex resulted in marked increases in femoral BMD and periosteal MAR compared to vehicle control. In contrast, Pkd1/Wwtr1 Oc-cKO mice were resistant to the anabolic effects of MS2. These findings suggest that PC1 and Wwtr1 form an anabolic mechanotransduction signaling complex that mediates mechanical loading responses and serves as a potential novel therapeutic target for treating osteoporosis.

60 APPLIED LIFE SCIENCES↗

Patterson #5-25 Well

CT scans, images, and MSCL data to accompany the Patterson #5-25 well TRS

Arbuckle Group; CCUS; Carbon storage; IMSCS↗

Sleepy Hollow Reagan Unit 86A Well Data

Computed tomography data described in the technical report series "Computed Tomography Scanning and Geophysical Measurements of the Integrated Mid-Continent Stacked Carbon Storage Hub Sleepy Hollow Reagan Unit 86A Well" by Thomas Paronish; Mathias Pohl; Alexis Parker; Rhiannon Schmitt; Johnathan Moore; Richard Spaulding; Igor Haljasmaa; Dustin Crandall; Valarie Smith; Andrew Duguid; and R. M. Joeckel

AS↗

WARE 1-9 Well

Computed tomography and core logger data described in Technical Report "Computed Tomography Scanning and Geophysical Measurements of the J. F. WARE Gas Unit 1-9 Well in Smith County, Texas" by Brinza et al. , 2024.

CoreCM↗

First-In-Human Validation of CT-Based Proton Range Prediction Using Prompt Gamma Imaging in Prostate Cancer Treatments

Uncertainty in computed tomography (CT)-based range prediction substantially impairs the accuracy of proton therapy. Direct determination of the stopping-power ratio (SPR) from dual-energy CT (DECT) has been proposed (DirectSPR), and initial validation studies in phantoms and biological tissues have proven a high accuracy. However, a thorough validation of range prediction in patients has not yet been achieved by any means. Here, we present the first systematic validation of CT-based proton range prediction in patients using prompt gamma imaging (PGI).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Core Characterization of Bakken Shale from the Bedwell 33-52-1-1H Well, Sheridan County, Montana

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize core of the Bedwell 33-52-1-1H well (API 25-091-21920), a wildcat field in Sheridan County, Montana. The primary impetus of this work is to provide a unique dataset to researchers at universities, national laboratories, geological surveys, and other locations for additional analyses. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/bedwell-33-52-1-1h-well. The equipment and techniques used to characterize the full core were non-destructive, enabling future examinations and analyses to be performed on these cores. However, none of the equipment used was suitable for direct visualization of the pore space in fine-grained structures such as those found in shales; fractures, discontinuities, and millimeter scale features were readily detectable with the methods tested. Imaging with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis. A selection of samples (Table 1) were cored, sliced, and powdered for additional characterization analyses. These analyses did involve destructive subsampling of the full core at discrete sections, and the results are presented here in the context of the larger core description. Selected sections of the core were removed from the full core for detailed analyses using the following destructive techniques: bulk inductively coupled plasma-optical emission spectroscopy (ICP-OES), isolation of carbon and sulfur, Fourier transform infrared (FTIR) spectroscopy, scanning electron microscopy (SEM), and higher resolution CT scan with NETL’s micro-CT scanning systems. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy related examinations traditionally performed at NETL.

04 OIL SHALES AND TAR SANDS↗

Computed Tomography Scanning and Geophysical Measurements of the Wabash No.1 Core

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize Mt. Simon core from the Wabash CarbonSAFE project, Wabash No. 1 well. The primary impetus of the work in this report is a collaboration between NETL Research and Innovation Center and the Illinois State Geological Survey at the Prairie Research Institute, University of Illinois Urbana-Champaign in Champaign, Illinois. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/wabash-no-1-well. The Wabash No. 1 well was drilled as part of a U.S. Department of Energy (DOE) funded Carbon Storage Assurance Facility Enterprise field project to assess the feasibility of developing a commercial-scale geological storage complex at the Wabash Valley Resources Integrated Gasification Combined Cycle plant near Terre Haute, Indiana. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. None of the equipment used was suitable for direct visualization of the pore space in fine-grained structures; fractures, discontinuities, and millimeter scale features were readily detectable with the methods tested. Imaging with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy-related examinations traditionally performed at NETL.

54 ENVIRONMENTAL SCIENCES↗

Computed Tomography Scanning and Geophysical Measurements of UW Enterprises LP 1-250512-129 Well in Southwestern Indiana

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia, were used to characterize Illinois Basin core of the Upper Devonian-Early Mississippian New Albany Shale Formation from Posey County, Indiana. The primary impetus of this work is a collaboration between Indiana Geological and Water Survey at Indiana University Bloomington, NETL, and Woolsey Operating Company LLC to characterize and make publicly available core information from the New Albany Shale of the Illinois Basin. Core characterization of this unconventional oil/gas well will aid in understanding the lithology changes and the fracture complexity of the New Albany Shale. There is a potential for this formation to be developed in the future for critical mineral and rare earth element (CM/REE) extraction. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/uw-enterprises. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on this core. None of the equipment used was suitable for direct visualization of the pore space in the fine-grained structures studied; however, fractures, discontinuities, and millimeter-scale features were readily detectable with the methods tested. Imaging with the NETL medical CT scanner was performed on the entire core. Targeted higher resolution CT scanning of select sections was performed with NETL’s industrial and micro-CT scanner. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy related examinations traditionally performed at NETL.

58 GEOSCIENCES↗

Computed Tomography Scanning and Geophysical Measurements of Appalachian Basin Core from the Jones and Laughlin #1 Well, Beaver County, PA

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia, were used to characterize Appalachian Basin core from Beaver County, Pennsylvania. The primary impetus of this work is a collaboration between the U.S. Department of Energy (DOE) and the Pennsylvania Geological Survey to characterize and make publicly available core information from the Onondaga-Huntersville formations of the Appalachian Basin. This stratigraphic well and the core data produced in this report will aid in understanding the structural complexities of the Onondaga-Huntersville formations. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/jonesandlaughlin1well. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. Fractures, discontinuities, and millimeter-scale features were readily detectable with imaging performed with the NETL medical CT scanner over the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for further study. Targeted higher resolution CT scanning of select sections was performed with NETL’s micro-CT scanner. The combination of methods used provides a multiscale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy related examinations traditionally performed at NETL.

58 GEOSCIENCES↗

Personalized and uncertainty-aware coronary hemodynamics simulations: From Bayesian estimation to improved multi-fidelity uncertainty quantification

Non-invasive simulations of coronary hemodynamics have improved clinical risk stratification and treatment outcomes for coronary artery disease, compared to relying on anatomical imaging alone. However, simulations typically use empirical approaches to distribute total coronary flow amongst the arteries in the coronary tree, which ignores patient variability, the presence of disease, and other clinical factors. Further, uncertainty in the clinical data often remains unaccounted for in the modeling pipeline. We present an end-to-end uncertainty-aware pipeline to (1) personalize coronary flow simulations by incorporating vessel-specific coronary flows as well as cardiac function; and (2) predict clinical and biomechanical quantities of interest with improved precision, while accounting for uncertainty in the clinical data. We assimilate patient-specific measurements of myocardial blood flow from clinical CT myocardial perfusion imaging to estimate branch-specific coronary artery flows. Simulated noise in the clinical data is used to estimate the joint posterior distributions of the model parameters using adaptive Markov Chain Monte Carlo sampling. Additionally, the posterior predictive distribution for the relevant quantities of interest is determined using a new approach combining multi-fidelity Monte Carlo estimation with non-linear, data-driven dimensionality reduction. This leads to improved correlations between high- and low-fidelity model outputs. Our framework accurately recapitulates clinically measured cardiac function as well as branch-specific coronary flows under measurement noise uncertainty. We observe substantial reductions in confidence intervals for estimated quantities of interest compared to single-fidelity Monte Carlo estimation and state-of-the-art multi-fidelity Monte Carlo methods. This holds especially true for quantities of interest that showed limited correlation between the low- and high-fidelity model predictions. In addition, the proposed multi-fidelity Monte Carlo estimators are significantly cheaper to compute than traditional estimators, under a specified confidence level or variance. The proposed pipeline for personalized and uncertainty-aware predictions of coronary hemodynamics is based on routine clinical measurements and recently developed techniques for CT myocardial perfusion imaging. The proposed pipeline offers significant improvements in precision and reduction in computational cost.

Bayesian parameter estimation↗

Plug-and-Play Methods for Integrating Physical and Learned Models in Computational Imaging: Theory, algorithms, and applications

Plug-and-play (PnP) priors constitute one of the most widely used frameworks for solving computational imaging problems through the integration of physical models and learned models. PnP leverages high-fidelity physical sensor models and powerful machine learning methods for prior modeling of data to provide state-of-the-art reconstruction algorithms. PnP algorithms alternate between minimizing a data fidelity term to promote data consistency and imposing a learned regularizer in the form of an image denoiser. Recent highly successful applications of PnP algorithms include biomicroscopy, computerized tomography (CT), magnetic resonance imaging (MRI), and joint ptychotomography. This article presents a unified and principled review of PnP by tracing its roots, describing its major variations, summarizing main results, and discussing applications in computational imaging. Additionally, we also point the way toward further developments by discussing recent results on equilibrium equations that formulate the problem associated with PnP algorithms.

97 MATHEMATICS AND COMPUTING↗

Multimodal Defect Imaging of Pure Tungsten Components Fabricated via Electron Beam Powder Bed Fusion

The utilization of additive manufacturing (AM) techniques for refractory materials in high-temperature environments has significantly expanded because of the ability to fabricate geometrically complex components. Electron beam powder bed fusion (EB-PBF), which provides lower residual stress, a cleaner vacuum environment, and better efficiency for high melting point, is one of the best-suited AM methods to produce advanced refractory components. However, the property variation attributed to the heterogeneous microstructure and process-induced defects has hindered the widespread adoption of EB-PBF-produced material like tungsten. While numerous in-situ monitoring and defect detection methods have been demonstrated for EB-PBF, a workflow that compares and evaluates process-induced abnormalities from different imaging perspectives is still limited. This study examines a feature-embedded tungsten component manufactured via the EB-PBF process to demonstrate the defect detection capabilities of a multimodal defect imaging workflow. The predefined and process-induced defects are evaluated by harnessing various imaging techniques, including in-situ electron imaging, layerwise near-infrared (NIR) imaging, post-build high-energy x-ray computed tomography (CT), and conventional destructive metallography. The results highlight the strengths and limitations of distinctive defect imaging techniques concerning specific defect types, sizes, and conditions. It was found that electron imaging can provide more abnormal detection capabilities while maintaining a higher measuring accuracy, against the conventional metallography in this case study, compared with NIR and CT imaging techniques.

36 MATERIALS SCIENCE↗