Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calcium Chloride”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Blood biochemical and cellular changes during a decompression procedure involving eight hours of oxygen prebreathing

Chemical and cellular parameters were measured in human subjects before and after exposure to a decompression schedule involving 8 h of oxygen prebreathing. The exposure was designed to simulate space-flight extravehicular activity (EVA) for 6 h. Several statistically significant changes in blood parameters were observed following the exposure: increases in calcium, magnesium, osmolality, low-density lipoprotein cholesterol, monocytes, and prothrombin time, and decreases in chloride, creatine phosphokinase and eosinophils. The changes, however, were small in magnitude and blood factor levels remained within normal clinical ranges. Thus, the decompression profile used in this study is not likely to result in blood changes that would pose a threat to astronauts during EVA.

Oxygen/administration & dosage↗

A coated-wire ion-selective electrode for ionic calcium measurements

A coated-wire ion-selective electrode for measuring ionic calcium was developed, in collaboration with Teknektron Sensor Development Corporation (TSDC). This coated wire electrode sensor makes use of advanced, ion-responsive polyvinyl chloride (PVC) membrane technology, whereby the electroactive agent is incorporated into a polymeric film. The technology greatly simplifies conventional ion-selective electrode measurement technology, and is envisioned to be used for real-time measurement of physiological and environment ionic constituents, initially calcium. A primary target biomedical application is the real-time measurement of urinary and blood calcium changes during extended exposure to microgravity, during prolonged hospital or fracture immobilization, and for osteoporosis research. Potential advanced life support applications include monitoring of calcium and other ions, heavy metals, and related parameters in closed-loop water processing and management systems. This technology provides a much simplified ionic calcium measurement capability, suitable for both automated in-vitro, in-vivo, and in-situ measurement applications, which should be of great interest to the medical, scientific, chemical, and space life sciences communities.

Hines, John W.↗

Calcium and nitrogen balance, experiment M007

The collection of data on the response of the skeletal and muscular systems to 14-day space flights was evaluated for loss of calcium, nitrogen, and other metabolically related elements. Considerable interindividual variability was demonstrated in all experimental factors that were measured. Calcium balance became less positive and urinary phosphate excretion increased substantially in flight despite a reduction in phosphate intake. Patterns of excretion of magnesium, sodium, potassium, and chloride were different for each subject, and, in part, could be correlated with changes in adrenocortical steroid production. The principal hormonal change was a striking decrease during flight in the urinary excretion of 17-hydroxycortocosteroids. Dermal losses of calcium, magnesium, sulfate, and phosphate were insignificant during all three phases.

Whedon, G. D.↗

Uptake of aqueous heavy metal ions (Co2+, Cu2+ and Zn2+) by calcium-aluminium-silicate-hydrate gels

Highlights: • C-A-S-H gels containing metal ions (Co{sup 2+}, Cu{sup 2+} or Zn{sup 2+}) were precipitated by a sol-gel technique. • Uptake mechanism and immobilization capacity of divalent metal ions by C-A-S-H are elucidated. • Up to ~55–60 mol% of Zn can be incorporated in defective tobermorite-type C-A-S-H. • Metal uptake by C-A-S-H is controlled mainly by isomorphous substitution for Ca ions. • Crystal-chemical features of C-A-S-H gels and implications for practical application are discussed. Calcium-aluminium-silicate-hydrate (C-A-S-H) gels containing heavy metal ions (Me: Co{sup 2+}, Cu{sup 2+} or Zn{sup 2+}) were precipitated at different Me/Si molar ratios to study the uptake mechanism and immobilization capacity. Aqueous solution chemistry and solid-phase characterization using XRD, FTIR, ESEM-EDX, TEM-HAADF and TG-DSC methods reveal threshold values for ion substitution of ~55–60 mol% for Zn, ~30–40 mol% for Co and ~25–30 mol% for Cu in defective tobermorite-type C-A-S-H with (Ca + Me)/(Si + Al) molar ratios from 0.86 to 1.04. At higher aqueous Me concentrations, Me (chloride) hydroxides start to co-precipitate. The uptake mechanism of Me ions by C-A-S-H is based on (i) isomorphous substitution of Me for Ca in the CaO layer, (ii) ion exchange in the interlayer, (iii) tetrahedral substitution (Zn) within the dreierketten chains and (iv) surface adsorption onto the C-A-S-H gel structure. Systematics in crystal-chemistry of Me-bearing C-A-S-H and implications for application and performance in natural and man-made settings are discussed.

36 MATERIALS SCIENCE↗

Field Testing of High Current Electrokinetic Nanoparticle Treatment for Corrosion Mitigation in Reinforced Concrete

This work examines field performance of nanoscale pozzolan treatments delivered el ctrokinetically to suppress chloride induced corrosion of concrete reinforcement. The particles are 20 nm silica spheres coated with 2 nm alumina particles that carry a net positive charge. Earlier work demonstrated that the alumina particles were stripped from the silica carriers and formed a dense phase with an interparticle spacing that is small enough to inhibit the transport of solvated chlorides. A D.C. field was used to inject the particles into the pores of concrete specimens, directly toward the mild steel bars that were embedded within each 3 inch diameter by 6 inch length concrete specimen. The voltage was held constant at 25 v per inch of concrete cover for a period of 7 days. These voltages permitted current densities as high as 3 A/sq m. During the final 3 days, a 1 molar solution of calcium nitrate tetrahydrate was used to provide a source of calcium to facilitate stronger and more densified phase formation within the pores. In a departure from prior work the particle treatments were started concurrent with chloride extraction in order to determine if particle delivery would inhibit chloride transport. Following treatment the specimens were immersed in seawater for 4 weeks. After this posttreatment exposure, the specimens were tested for tensile strength and the steel reinforcement was examined for evidence of corrosion. Scanning electron microscopy was conducted to assess impact on microstructure.

Calle, Luz Marina↗

Thermo-chemo-mechanical understanding of damage development in porous cementitious materials exposed to sodium chloride under thermal cycling

Interactions between sodium chloride (NaCl) and cementitious materials have shown to facilitate premature deteriorations of concrete in cold environments. NaCl chemically interacts with tri‑calcium aluminate (C{sub 3}A) and monosulfate (AF{sub m}) resulting in a chemical phase change during thermal cycling. The chemical phase change can create damage in porous cementitious materials. Experimental and thermodynamic modeling were conducted in this study to understand the thermo-chemo-physical interactions between NaCl and cementitious materials and identify the source of the chemical phase change. Results indicates that the destructive chemical phase change is the formation of mirabilite (Na{sub 2}SO{sub 4}.10H{sub 2}O). It was found that the phase change temperature of mirabilite is strongly influenced by the concentration of NaCl in the solution. At high concentration NaCl solutions (>10% by mass), mirabilite is formed due to the release of a small amount of sulfate ions from the concrete matrix.

36 MATERIALS SCIENCE↗

Materials Data on CaC2 by Materials Project

CaC2 is Cyanogen Chloride-derived structured and crystallizes in the monoclinic C2/m space group. The structure is zero-dimensional and consists of two calcium, dimethyl- molecules. Ca2+ is bonded in a linear geometry to two equivalent C1- atoms. Both Ca–C bond lengths are 2.24 Å. C1- is bonded in a single-bond geometry to one Ca2+ atom.

36 MATERIALS SCIENCE↗

Calcium Sulfate in Atacama Desert Basalt: A Possible Analog for Bright Material in Adirondack Basalt, Gusev Crater

The Atacama Desert in northern Chile is one of the driest deserts on Earth (< 2mm/y). The hyper-arid conditions allow extraordinary accumulations of sulfates, chlorides, and nitrates in Atacama soils. Examining salt accumulations in the Atacama may assist understanding salt accumulations on Mars. Recent work examining sulfate soils on basalt parent material observed white material in the interior vesicles of surface basalt. This is strikingly similar to the bright-white material present in veins and vesicles of the Adirondack basalt rocks at Gusev Crater which are presumed to consist of S, Cl, and/or Br. The abundance of soil gypsum/anhydrite in the area of the Atacama basalt suggested that the white material consisted of calcium sulfate (Ca-SO4) which was later confirmed by SEM/EDS analysis. This work examines the Ca-SO4 of Atacama basalt in an effort to provide insight into the possible nature of the bright material in the Adirondack basalt of Gusev Crater. The objectives of this work are to (i) discuss variations in Ca-SO4 crystal morphology in the vesicles and (ii) examine the Ca-SO4 interaction(s) with the basalt interior.

Sutter, B.↗

Electrokinetic comparison of CaF 2 and AgCl from a MDS perspective

CaF 2 has limited electrokinetic sensitivity to fluoride ions in solution and the positive CaF 2 surface charge is not reversed at high fluoride ion concentration. Similar insensitivity of surface charge to high fluoride ion concentration has been observed for other alkali and alkaline earth fluoride salts. On the contrary, chloride ions act as potential determining ions for AgCl and reverse the surface charge, as expected. FTIR-IRS results indicate that the AgCl/water interface has a water structure-breaking tendency, whereas the CaF 2 /water interface has a structure-making tendency. Here, it is speculated that the strong hydrogen bonding between fluoride ions and water prevents the accommodation of excess fluoride ions at surface lattice sites of fluorite, and therefore explains the low sensitivity of the fluorite surface charge sign and magnitude to fluoride ion concentration. However, this speculation has not been examined at the molecular level and is evaluated by molecular dynamics simulations (MDS) in the research presented in this paper. Higher hydrogen bond density at the CaF 2 mineral/water interface confirms that the water structure has stronger hydrogen bonding at both the CaF 2 mineral surface and with the F - ion in solution. In this way, the interaction of the F - ion with the CaF 2 surface is inhibited.

36 MATERIALS SCIENCE↗

Electrochemical generation of oxygen. 1: The effects of anions and cations on hydrogen chemisorption and anodic oxide film formation on platinum electrode. 2: The effects of anions and cations on oxygen generation on platinum electrode

The effects were studied of anions and cations on hydrogen chemisorption and anodic oxide film formation on Pt by linear sweep voltammetry, and on oxygen generation on Pt by potentiostatic overpotential measurement. The hydrogen chemisorption and anodic oxide film formation regions are greatly influenced by anion adsorption. In acids, the strongly bound hydrogen occurs at more cathodic potential when chloride and sulfate are present. Sulfate affects the initial phase of oxide film formation by produced fine structure while chloride retards the oxide-film formation. In alkaline solutions, both strongly and weakly bound hydrogen are influenced by iodide, cyanide, and barium and calcium cations. These ions also influence the oxide film formation. Factors considered to explain these effects are discussed. The Tafel slope for oxygen generation was found to be independent on the oxide thickness and the presence of cations or anions. The catalytic activity indicated by the exchange current density was observed decreasing with increasing oxide layer thickness, only a minor dependence on the addition of certain cations and anions was found.

Huang, C. J.↗

Combustion system processes leading to corrosive deposits

Degradation of turbine engine hot gas path components by high temperature corrosion can usually be associated with deposits even though other factors may also play a significant role. The origins of the corrosive deposits are traceable to chemical reactions which take place during the combustion process. In the case of hot corrosion/sulfidation, sodium sulfate was established as the deposited corrosive agent even when none of this salt enters the engine directly. The sodium sulfate is formed during the combustion and deposition processes from compounds of sulfur contained in the fuel as low level impurities and sodium compounds, such as sodium chloride, ingested with intake air. In other turbine and power generation situations, corrosive and/or fouling deposits can result from such metals as potassium, iron, calcium, vanadium, magnesium, and silicon.

Stearns, C. A.↗

Combustion system processes leading to corrosive deposits

Degradation of turbine engine hot gas path components by high temperature corrosion can usually be associated with deposits even though other factors may also play a significant role. The origins of the corrosive deposits are traceable to chemical reactions which take place during the combustion process. In the case of hot corrosion/sulfidation, sodium sulfate was established as the deposited corrosive agent even when none of this salt enters the engine directly. The sodium sulfate is formed during the combustion and deposition processes from compounds of sulfur contained in the fuel as low level impurities and sodium compounds, such as sodium chloride, ingested with intake air. In other turbine and power generation situations, corrosive and/or fouling deposits can result from such metals as potassium, iron, calcium, vanadium, magnesium, anad silicon. Previously announced in STAR as N81-23243

Stearns, C. A.↗

Cation Data for the East River Watershed, Colorado (2014-2025)

This data package contains mean values for cation concentration for water samples taken from the East River Watershed in Colorado. Inductively coupled plasma mass spectrometry (ICP-MS) has been used to measure the concentrations of elements of interest simultaneously for the East River Watershed, Colorado groundwater and surface water samples to inform insights on the biogeochemistry processes within the watershed. The East River is part of the Watershed Function Scientific Focus Area (WFSFA) located in the Upper Colorado River Basin, United States. For samples collected prior to 06-16-2021, the instrumentation, Elan DRC II, PerkinElmer SCIEX, automatically switches among the three models necessary to analyze all 37 elements. These 37 elements include: (1) Lithium (Li), Beryllium (Be), Boron (B), Sodium (Na), Magnesium (Mg), Aluminium (Al), Silicon (Si), Phosphorus (P), Titanium (Ti), Cobalt (Co), Nickel (Ni), Copper (Cu), Zinc (Zn), Germanium (Ge), Arsenic (As), Rubidium (Rb), Strontium (Sr), Zirconium (Zr), Molybdenum (Mo), Silver (Ag), Cadmium (Cd), Tin (Sn), Antimony (Sb), Caesium (Cs), Barium (Ba), Europium (Eu), Lead (Pb), Thorium (Th), Uranium (U) using standard model, argon Ar as reaction gas, (2) Potassium (K), Calcium (Ca), Vanadium (V), Chromium (Cr), Manganese (Mn), Iron (Fe) using dynamic reaction cell (DRC) model, ammonia NH3 as reaction gas, and (3) Phosphorus (P) and Selenium (Se) using DRC model, oxygen O2 as reaction gas. Note for the samples with higher concentrations of chloride (Cl-), asenic (As) concentrations were analysed with DRC model (oxygen O2 as reaction gas) to avoid the interference of chloride. For samples collected on and after 06-16-2021, an advanced Agilent 8900 triple quadrupole inductively coupled plasma mass spectrometry system (Agilent 8900 QQQ ICP-MS, Agilent Technologies) has been used to measure the concentrations of interested 36 elements simultaneously for environmental samples, including (1) Lithium (Li), Beryllium (Be) and Boron (B) using standard no gas mode, (2) Sodium (Na), Magnesium (Mg), Aluminium (Al) Phosphorus (P), Potassium (K), Chromium (Cr), Manganese (Mn), Iron (Fe), Cobalt (Co), Nickel (Ni), Copper (Cu), Zinc (Zn), Germanium (Ge), Arsenic (As), Rubidium (Rb), Strontium (Sr), Zirconium (Zr), Molybdenum (Mo), Silver (Ag), Cadmium (Cd), Tin (Sn), Antimony (Sb), Cesium (Cs), Barium (Ba), Europium (Eu), Lead (Pb), Thorium (Th) and Uranium (U) using standard helium (He) collision mode, (3) Titanium (Ti) and Vanadium (V) using high Energy (HEHe) helium (He) collision mode, and (4) Silicon (Si), Calcium (Ca) and Selenium (Se) using standard H2 reaction mode. All samples were prepared/diluted with 2% (v/v) ultrapure nitric acid in Milli-Q water (18.2 mega ohm-cm), and analyzed under a rigorous quality assurance and quality control (QA/QC) process. This data package contains (1) a zip file (cation_data_2014_2025.zip) containing a total of 5,849 files: 5.848 data files of cation data from across the Lawrence Berkeley National Laboratory (LBNL) Watershed Function Scientific Focus Area (SFA) which is reported in .csv files per location and a locations.csv (1 file) with latitude and longitude for each location; (2) a file-level metadata (v6_20260901_flmd.csv) file that lists each file contained in the dataset with associated metadata; (3) a data dictionary (v6_20260901_dd.csv) file that contains terms/column_headers used throughout the files along with a definition, units, and data type; (4) PDF and docx files for the detemination of Method Detection Limits (MDLs) for ICP-MS PerkinElmer DRC II instrumentation (Detemination_of_Method_Detection_Limits__MDLs__for_ICP_MS__PerkinElmer_Elan_DRC_II__LBL_Bldg74_Lab214D) for samples before November 2021; (5) PDF and docx files for the determination of MDLs for ICP-MS Agilent 8900 QQQ instrumentation (ICP_MS_Analysis_detection_limits_and_QA_QC_WenmingDong_updated_2026-08-06) for samples November 2021 and onward. Missing values within the anion data files are noted as either "-9999" or "0.0" for not detectable (N.D.) data. There are a total of 113 locations containing cation data. Update on 2021-04-11: Added Detemination of Method Detection Limits (MDLs) for ICP-MS document, which can be accessed as a PDF or with Microsoft Word. Update on 2022-06-10: versioned updates to this dataset was made along with these changes: (1) updated cation data for all locations up to 2021-12-31, (2) removal of units from column headers in datafiles, (3) added row underneath headers to contain units of variables, (4) removed suffix and prefix on two variables (“aqberylliumion_asberyllium” and “aqlithiumion_aslithium”), (5) added -9999 for empty numerical cells, and (6) the addition of the file-level metadata (flmd.csv) and data dictionary (dd.csv) were added to comply with the File-Level Metadata Reporting Format. Update on 2022-09-09: Updates were made to reporting format specific files (file-level metadata and data dictionary) to correct swapped file names, add additional details on metadata descriptions on both files, add a header_row column to enable parsing, and add version number and date to file names (v2_20220909_flmd.csv and v2_20220909_dd.csv). Update on 2023-08-08: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-01-05. The file level metadata and data dictionary files were updated to reflect the additional data added. Update on 2024-03-11: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-10-16. Further, revisions to the data files were made to remove incorrect data points (from 1970 and 2001). The reporting format specific files were updated to reflect the additional data added. Updated versions of the PDF and docx files for determination of MDLs for ICP-MS data were added to this dataset for samples starting in November 2021. Update on 2025-05-15: Updates were made to both the data files and reporting format specific files. New available cation data was added, up until the end of WY2024 (September 30, 2024). International Generic Sample Numbers (IGSNs), when registered, were added to the data files. The reporting format specific files were updated to reflect the additional data added. Update on 2026-09-01: Updates were made to both the data files and reporting format specific files. New available cation data was added, up until the end of WY2025 (September 30, 2025). Updated versions, as of 2026-08-06, of the PDF and docx files for determination of MDLs for ICP-MS data were added to this dataset for samples starting in November 2021.

54 ENVIRONMENTAL SCIENCES↗

Atmospheric particle abundance and sea salt aerosol observations in the springtime Arctic: a focus on blowing snow and leads

Abstract. Sea salt aerosols play an important role in the radiation budget and atmospheric composition over the Arctic, where the climate is rapidly changing. Previous observational studies have shown that Arctic sea ice leads are an important source of sea salt aerosols, and modeling efforts have also proposed blowing snow sublimation as a source. In this study, size-resolved atmospheric particle number concentrations and chemical composition were measured at the Arctic coastal tundra site of Utqiaġvik, Alaska, during spring (3 April–7 May 2016). Blowing snow conditions were observed during 25 % of the 5-week study period and were overpredicted by a commonly used blowing snow parameterization based solely on wind speed and temperature. Throughout the study, open leads were present locally. During periods when blowing snow was observed, significant increases in the number concentrations of 0.01–0.06 µm particles (factor of 6, on average) and 0.06–0.3 µm particles (67 %, on average) and a significant decrease (82 %, on average) in 1–4 µm particles were observed compared to low wind speed periods. These size distribution changes were likely caused by the generation of ultrafine particles from leads and/or blowing snow, with scavenging of supermicron particles by blowing snow. At elevated wind speeds, both submicron and supermicron sodium and chloride mass concentrations were enhanced, consistent with wind-dependent local sea salt aerosol production. At moderate wind speeds below the threshold for blowing snow as well as during observed blowing snow, individual sea spray aerosol particles were measured. These individual salt particles were enriched in calcium relative to sodium in seawater due to the binding of this divalent cation with organic matter in the sea surface microlayer and subsequent enrichment during seawater bubble bursting. The chemical composition of the surface snowpack also showed contributions from sea spray aerosol deposition. Overall, these results show the contribution of sea spray aerosol production from leads on both aerosols and the surface snowpack. Therefore, if blowing snow sublimation contributed to the observed sea salt aerosol, the snow being sublimated would have been impacted by sea spray aerosol deposition rather than upward brine migration through the snowpack. Sea spray aerosol production from leads is expected to increase, with thinning and fracturing of sea ice in the rapidly warming Arctic.

54 ENVIRONMENTAL SCIENCES↗

Heterogeneous phase reactions of Martian volatiles with putative regolith minerals

The chemical reactivity of several minerals thought to be present in Martian fines is tested with respect to gases known in the Martian atmosphere. In these experiments, liquid water is excluded from the system, environmental temperatures are maintained below 0 C, and the solar illumination spectrum is stimulated in the visible and UV using a xenon arc lamp. Reactions are detected by mass spectrometric analysis of the gas phase over solid samples. No reactions were detected for Mars nominal gas over sulfates, nitrates, chloride, nontronite clay, or magnetite. Oxidation was not observed for basaltic glass, nontronite, and magnetite. However, experiments incorporating SO2 gas an expected product of volcanism and intrusive volatile release - gave positive results. Displacement of CO2 by SO2 occurred in all four carbonates tested. These reactions are catalyzed by irradiation with the solar simulator. A calcium nitrate hydrate released NO2 in the presence of SO2. These results have implications for the cycling of atmospheric CO2, H2O, and N2 through the regolith.

Clark, B. C.↗

Perchlorate Reduction by Yeast for Mars Exploration

Martian soil contains high levels (0.6 percentage by mass) of calcium perchlorate (Ca(ClO4)2), which readily dissociates into calcium and the perchlorate ion (ClO4−) in water. Even in trace amounts, perchlorates are toxic to humans and have been implicated in thyroid dysfunction. Devising methods to lessen perchlorate contamination is crucial to minimizing the health risks associated with human exploration and colonization of Mars. We designed a perchlorate reduction pathway, which sequentially reduces perchlorate to chloride (Cl−) and oxygen (O2), for implementation in the yeast Saccharomyces cerevisiae. Using genes obtained from perchlorate reducing bacteria Azospira oryzae and Dechloromonas aromatica, we plan to assemble this pathway directly within S. cerevisiae through recombinational cloning. A perchlorate reduction pathway would enable S. cerevisiae to lower perchlorate levels and produce oxygen, which may be harvested or used directly by S. cerevisiae for aerobic growth and compound synthesis. Moreover, using perchlorate as an external electron acceptor could improve the efficiency of redox-imbalanced production pathways in yeast. Although several perchlorate reducing bacteria have been identified and utilized in water treatment systems on Earth, the widespread use of S. cerevisiae as a synthetic biology platform justifies the development of a perchlorate reducing strain for implementation on Mars.

Perchlorate↗

The “good,” the “bad,” and the “hidden” in neutron scattering and molecular dynamics of ionic aqueous solutions

We characterize a concentrated 7.3 m CaCl 2 solution, combining neutron diffraction with chloride isotopic substitution (Cl-NDIS) in null water and molecular dynamics (MD) simulations. We elucidate the solution structure, thermodynamic properties, and extent of ion pairing previously suggested as concentration-dependent and often not observed at lower concentrations. Our Cl-NDIS measurements designate the solvent-shared ion pairing as dominant and the contact ion pairing (CIP) as insignificant even under conditions close to the solubility limit. The MD models parameterized against neutron diffraction with calcium isotopic substitution (Ca-NDIS) overestimate CIP despite successfully reproducing most of the Cl-NDIS signal. This drawback originates from the fact that Ca 2+ –Cl - interactions were primarily “hidden” in the Ca-NDIS signal due to overlapping with Ca 2+ –O w and Ca 2+ –H w contributions to the total scattering. Contrary, MD models with moderate CIP and possessing generally good performance at high concentrations fail to reproduce the NDIS measurements accurately. Therefore, the electronic polarization, introduced in most of the recent MD models via scaling ionic charges, resolves some but not all parameterization drawbacks. We conclude that despite improving the quality of MD models “on average,” the question “which model is the best” has not been answered but replaced by the question “which model is better for a given research.” An overall “good” model can still be inappropriate or, in some instances, “bad” and, unfortunately, produce erroneous results. Additionally, the accurate interpretation of several NDIS datasets, complemented by MD simulations, can prevent such mistakes and help identify the strengths, weaknesses, and convenient applications for corresponding computational models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Activation of the CaR-CSE/H2S pathway confers cardioprotection against ischemia-reperfusion injury

Ischemia-reperfusion (I/R) injury is a multifactorial process triggered when an organ is subjected to transiently reduced blood supply. The result is a cascade of pathological complications and organ damage due to the production of reactive oxygen species following reperfusion. The present study aims to evaluate the role of activated calcium-sensing receptor (CaR)-cystathionine γ-lyase (CSE)/hydrogen sulfide (H2S) pathway in I/R injury. Firstly, an I/R rat model with CSE knockout was constructed. Transthoracic echocardiography, TTC and HE staining were performed to determine the cardiac function of rats following I/R Injury, followed by TUNEL staining observation on apoptosis. Besides, with the attempt to better elucidate how CaR-CSE/H2S affects I/R, in-vitro culture of human coronary artery endothelial cells (HCAECs) was conducted with gadolinium chloride (GdCl3, a CaR agonist), H{sub 2}O{sub 2}, siRNA against CSE (siCSE), or W7 (a CaM inhibitor). The interaction between CSE and CaM was subsequently detected. Plasma oxidative stress indexes, H2S and CSE, and apoptosis-related proteins were all analyzed following cell apoptosis. We found that H2S elevation led to the improvement whereas CSE knockdown decreased cardiac function in rats with I/R injury. Moreover, oxidative stress injury in I/R rats with CSE knockout was aggravated, while the increased expression of H2S and CSE in the aortic tissues resulted in alleviated the oxidative stress injury. Moreover, increased H2S and CSE levels were found to inhibit cell apoptotic ability in the aortic tissues after I/R injury, thus attenuating oxidative stress injury, accompanied by inhibited expression of apoptosis-related proteins. In HCAECs following oxidative stress treatment, siCSE and CaM inhibitor were observed to reverse the protection of CaR agonist. Coimmunoprecipitation assay revealed the interaction between CSE and CaM. Taken together, all above-mentioned data provides evidence that activation of the CaR-CSE/H2S pathway may confer a potent protective effect in cardiac I/R injury.

60 APPLIED LIFE SCIENCES↗