Search NASA⌕ Search

SEARCH · Search NASA

Results for “Camera calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Collision Tracking in OpenMC: Methods and Applications in Neutron Noise, Neutron Imaging, Time-of-Flight, and Multiplicity Counting

We present the development and application of a collision tracking feature within the OpenMC Monte Carlo particle transport code, designed for diverse applications such as neutron spectroscopy, scatter camera system, neutron noise, and multiplicity counting simulations. This feature enables the tracking of individual particle collisions, with potential applications in nuclear nonproliferation, reactor physics, and nuclear security. Additionally, the feature holds potential for the calibration of neutron detectors, specifically in converting light output into energy deposited within the detectors. The implementation consists of a set of filters—such as reaction type, energy, cell, and material—that constrain the set of collisions that are tracked, extensions to the Python API to enable simple input specification, and support for writing either OpenMC’s native HDF5-based format or the Monte Carlo particle list format. This feature was added to the official OpenMC release in version 0.15.3. In this work, the feature will be applied to showcase scenarios such as time-of-flight simulations, scatter-camera imaging for neutron source localization, neutron-noise analysis to extract integral kinetic parameters such as the prompt decay constant α, and multiplicity counting to estimate the mass of special nuclear materials. Ultimately, this feature aims to expand the application scope of open-source Monte Carlo particle transport codes such as OpenMC.

Monte Carlo code↗

Hybrid interferometric diagnostic for the refractive index measurement across nearly discrete shock waves

The measurement of high temperature gas properties is key for characterizing high speed flows. Nearly discrete changes in density across shock waves, in particular, are difficult to resolve through traditional fringe-counting interferometric methods. Existing techniques for estimating large fringe jumps are either resolution limited or require specialized window configurations. In this Letter, we describe a unique hybrid interferometric technique that combines narrowband fringes for high resolution and broadband fringes as an absolute reference to measure changes in refractive index with a resolution of up to 7 × 10 −8 across nearly discrete index changes of up to 1.5 × 10 −4 . By capturing fringes with an ultrahigh-speed camera, the refractive index changes across discrete shock fronts can be estimated inside a shock tube with high accuracy and time resolution. First, a novel hybrid calibration method for tracking finite fringes is discussed. Next, this technique is used to measure the post-initial-shock refractive indices for Mach 2.7 to 4.2 flows (pressures from 90.4 to 228.4 kPa). Results are then compared with theoretical values showing agreement within 2%.

Wang, Gwendolyn T. (ORCID:000000016271893X)↗

The Absolute Color Calibration of the Dark Energy Survey: A Spectrophotometric Sample of DA White Dwarfs in the Southern Sky

The Dark Energy Survey (DES), which is nearing the completion of the analysis of its full data set, is an imaging survey of one-quarter of the Southern sky down to an apparent magnitude of $i\sim24.5$. The survey observations were conducted between 2013 and 2019 with a 3-square-degree wide-field CCD mosaic camera (the Dark Energy Camera, or DECam) on the Blanco 4-meter telescope at the Cerro Tololo Interamerican Observatory in the Chilean Andes. The primary scientific goal of the DES was to measure properties of Dark Energy. In order to achieve its science goals, the DES had tight requirements on both its relative and absolute photometric calibrations. In this poster, we describe the sample of pure-hydrogen-atmosphere (“DA”) white dwarfs which were instrumental in working to establish the requirement on the absolute color calibration -- i.e., the calibration across the filter bands -- of the DES.

79 ASTRONOMY AND ASTROPHYSICS↗

Calibration of the sub-aperture backscatter system on OMEGA EP

The sub-aperture backscatter (SABS) diagnostic on the OMEGA EP Laser System is a diagnostic that is used to measure the backscattered and sidescattered light during laser–plasma interaction experiments that are relevant to high-energy-density physics and inertial confinement fusion. The diagnostic collects stimulated Brillouin scattering (SBS) UV light at around 351 nm and stimulated Raman scattering (SRS) in the visible-light regime in the 420–720-nm-wavelength range and provides spectrally and temporally resolved information. Five 1-in. light collectors, composed of a lens, ground glass diffuser, and coupling into a 300-μm fiber, are positioned behind the last steering mirror on one of the four beamlines to catch a portion of the beam cross section (~1.5%) of the emission that is scattered into the beamline. The SRS light is collected in two light collectors, combined, and transported via graded index fibers to a streaked spectrometer. The SABS-SRS streak spectrometer has a temporal and spectral resolution of 100 ps and 1 nm, respectively. Three other light collectors collect, combine, and transport the SBS signal to a Hamamatsu high-voltage photodiode, where an oscilloscope digitizes the data, providing a time resolution of better than 1 ns. To obtain an absolute energy calibration of SRS measurements, light signals of known energy and wavelength were injected into the light collectors one at a time. The resulting counts on the streak camera charge-coupled device for SRS are then correlated with the incident fluence of scattered light at the light collector in order to allow a quantitative assessment of streak camera sensitivity to determine the energy of the scattered light during experiments. The measurements were performed in situ from the light collectors to the detectors. Other offline measurements provided the transmission of the optics between the target chamber center and the light collectors.

47 OTHER INSTRUMENTATION↗

Infrastructure-Based Cooperative Perception at a Traffic Intersection: Overview and Challenges: Preprint

Recent advancement in autonomous driving vehicles and V2X communication has attracted increasing attention towards Intelligent Transportation Systems to build a safe and reliable traffic intersection. However, most of the systems are still at the initial stages and require significant progress to become a reality. This paper presents an overview of NREL Infrastructure Perception and Control (IPC) framework which is an open-source track-data fusion engine which takes input from infrastructure-based perception sensors and cooperatively shared messages from Connected Autonomous Vehicles (CAVs) and Connected Vehicle (CVs) and the challenges associated with deploying such cooperative perception framework at a four-way traffic intersection in the city of Colorado Springs, CO, USA. The sensor data is collected by deploying two radars and two LiDAR sensors on the IPC mobile lab and two radars on diagonally opposite traffic poles at the proposed intersection. The sensor output results imply the need for rapid sensor calibration to bring the collective perception to a common coordinate frame, the importance of time synchronization between the sensors in order to capture accurate spatial and temporal alignment of the objects, and the need for a health monitoring system with fail safe closed-loop detection model for real-time deployment.

camera↗

Photometry and astrometry with JWST – III. A NIRCam-Gaia DR3 analysis of the open cluster NGC 2506

ABSTRACT In the third paper of this series aimed at developing the tools for analysing resolved stellar populations using the cameras on board of the James Webb Space Telescope (JWST), we present a detailed multiband study of the 2 Gyr Galactic open cluster NGC 2506. We employ public calibration data sets collected in multiple filters to: (i) derive improved effective Point Spread Functions (ePSFs) for 10 NIRCam filters; (ii) extract high-precision photometry and astrometry for stars in the cluster, approaching the main sequence (MS) lower mass of ∼0.1 M⊙; and (iii) take advantage of the synergy between JWST and Gaia DR3 to perform a comprehensive analysis of the cluster’s global and local properties. We derived a MS binary fraction of ∼57.5 per cent, extending the Gaia limit (∼0.8 M⊙) to lower masses (∼0.4 M⊙) with JWST. We conducted a study on the mass functions (MFs) of NGC 2506, mapping the mass segregation with Gaia data, and extending MFs to lower masses with the JWST field. We also combined information on the derived MFs to infer an estimate of the cluster present-day total mass. Lastly, we investigated the presence of white dwarfs (WDs) and identified a strong candidate. However, to firmly establish its cluster membership, as well as that of four other WD candidates and of the majority of faint low-mass MS stars, further JWST equally deep observations will be required. We make publicly available catalogues, atlases, and the improved ePSFs.

Nardiello, D. (ORCID:0000000311493659)↗

SITCOMTN-162: Testing the implementation of Metadetection and Cell-Based Coadds on Abell 360 LSSTComCam data

The purpose of this technote is to test the technical quality of LSSTComCam commissioning data, specifically the Rubin_SV_38_7 field, by utilizing cell-based coadds and Metadetection by measuring the tangential and cross weak lensing shear profiles of the massive cluster Abell 360 (called A360 throughout the technote). The process entails generating the cell-based coadds for Metadetection to run on, identifying and removing cluster member galaxies, applying quality cuts, calibrating the shear measurements, and validation. Cell-based coadds and Metadetection are both currently in the process of being implemented within the LSST Science Pipelines at the time of this technote. There is substantial technical value in attempting a difficult measurement prior to full implementation. Measuring the tangential shear around A360 will showcase the current abilities of these algorithms, as well as highlight where work is still needed. As seen from the resulting shear profile of A360, the cell-based coadds and Metadetection are able to work in tandem to produce a shear catalog and resulting reduced shear profile. This technote is one part of a series studying A360 in order to both stress test the commissioning camera and demonstrate the technical capabilities of the Vera Rubin Observatory. We study the quality of the PSF modeling and impact it can have on cluster WL in [Combet et al., 2025], implementation of cell-based coadds and subsequent use for Metadetect [Sheldon et al., 2023] in this technote, photometric calibration in (in prep), source selection and photometric redshifts in [Adari et al., 2025], use of Anacal [Li et al., 2024] to produce a cluster shear profile in [Li et al., 2025], and background subtraction in this field and Fornax in [Zhou et al., 2025].

79 ASTRONOMY AND ASTROPHYSICS↗

O 2 based resonantly ionized photoemission thermometry analysis of supersonic flows

Characterization of the thermal gradients within supersonic and hypersonic flows is essential for understanding transition, turbulence, and aerodynamic heating. Developments in novel, impactful non-intrusive techniques are key for enabling flow characterizations of sufficient detail that provide experimental validation datasets for computational simulations. In this work, Resonantly Ionized Photoemission Thermometry (RIPT) signals are directly imaged using an ICCD camera to realize the techniques 1D measurement capability for the first time. The direct imaging scheme presented for oxygen-based RIPT (O 2 RIPT) uses the previously established calibration data to direct excite various resonant rotational peaks within the S-branch of the C 3 Π, ( v = 2) ← X 3 Σ( v ′ = 0) absorption band of O 2 . The efficient ionization of O 2 liberates electrons that induce electron avalanche ionization of local N 2 molecules generating N 2 + , which primarily deexcites via photoemissions of the first negative band of N 2 + ( B 2 Σ <#comment/> u + − <#comment/> X 2 Σ <#comment/> g + ) . When sufficient lasing energy is used, the ionization region and subsequent photoemission signal is achieved along a 1D line thus, if directly imaged can allow for gas temperature assignments along said line; demonstrated here of up to five centimeters in length. The temperature gradients present within the ensuing shock train of a supersonic under expanded free jet serves as a basis of characterization for this new RIPT imaging scheme. The O 2 RIPT results are extensively compared and validated against well-known and established techniques (i.e., CARS and CFD). The direct imaging capability fully realizes the technique’s fundamental potential and is expected to be the standard of implementation going forward. The direct imaging capability can play instrumental roles in future scientific studies that rely upon acute characterization of thermal gradients within a medium that cannot be easily resolved by a point. Furthermore, the removal of the spectrometer greatly reduces the cost, complexity, and optical alignment associated with prior RIPT measurements.

42 ENGINEERING↗

Measurement of laser absorption in underdense plasmas using near-field imaging of the incident and transmitted beams

Measurements of laser absorption in high-temperature, underdense plasmas produced at the Omega Laser Facility are made using two near-field imaging detectors that diagnose the spatial profile and energy of the port P9 beam before and after it transmits through the plasma. The incident beam is sampled using a partial reflection from a full-aperture, (30 cm-diam) uncoated wedge pickoff located before the target chamber vacuum window and final focus lens assembly. A concave mirror reduces the reflected beam size, allowing it to be recorded directly using a charged-coupled device (CCD) camera. The P9 transmitted beam diagnostic (P9TBD) characterizes the transmitted light by terminating the expanded beam on a semi-transparent diffuser and imaging the illuminated surface using a lens and CCD camera. The P9TBD samples a numerical aperture twice as large as the input beam, allowing the energy of transmitted beams with moderate levels of beam spray to be measured accurately. Calibration shots with no plasma provide a path to infer absorption without absolute photometric calibration of either detector. Lastly, the cross-calibration between the two detectors was measured to remain stable at ±200 ppm, enabling measurements of total beam absorption below 1% with ±0.07% error.

47 OTHER INSTRUMENTATION↗

Design and Characterization of an Optically Segmented Single Volume Scatter Camera Module

Here, the optically segmented single volume scatter camera (OS-SVSC) aims to image neutron sources for nuclear nonproliferation applications using the kinematic reconstruction of elastic double-scatter events. We report on the design, construction, and calibration of one module of a new prototype. The module includes 16 EJ-204 organic plastic scintillating bars individually wrapped in Teflon tape, each measuring 0.5cx0.5cmx20cm . The scintillator array is coupled to two custom silicon photomultiplier (SiPM) boards consisting of a 2x8 array of SensL J-Series-60035 SiPMs, which are read out by a custom 16 channel DRS4 based digitizer board. The electrical crosstalk between SiPMs within the electronics chain is measured as 0.76%±0.11% among all 16 channels. We report the detector response of one module including interaction position, time, and energy, using two different optical coupling materials: EJ-560 silicone rubber optical coupling pads and EJ-550 optical coupling grease. We present results in terms of the overall mean and standard deviation of the z -position reconstruction and interaction time resolutions for all 16 bars in the module. We observed the 1σz -position resolution for gamma interactions in the 0.3–0.4 MeVee range to be 2.24 cm ± 1.10 cm and 1.45 cm ± 0.19 cm for silicone optical coupling pad and optical grease, respectively. The observed 1σ interaction time resolution is 265 ps ± 29 ps and 235 ps ± 10 ps for silicone optical coupling pad and optical grease, respectively.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Single-Volume Scatter Camera (Final Report)

This document serves as a comprehensive final report for the Single-Volume Scatter Camera (SVSC) project. Most of the work over the course of this project has been documented in journal articles, conference papers, and other reports. We therefore reference those materials for detailed presentation of our technical results. The most recent efforts on the project have not been published and are presented in detail here. We present characterizations of two neutron scatter camera prototypes; one using a monolithic geometry, and one using an optically segmented geometry. Both detectors employ plastic scintillator with SiPM-based readout. For the monolithic prototype, we present calibrations of several detector parameters made using a set of dark counts. In particular, we employ a coincidence analysis to characterize the distribution external optical crosstalk, along with the relative timing of the different SiPMs. For the optically segmented prototype we present the results of calibrations made using a tagged 22 Na source, as well as the results of an imaging measurement made using a tagged AmBe source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using Fiducial Markers for Pose Estimation of an OSWEC in a Wave Tank: Preprint

In this study, we consider a novel method of sensing the motion of a wave energy converter during testing in a wave flume under the influence of incoming waves. The wave energy converter considered in our research is an oscillating surge wave energy converter, which is a hinged paddle that responds to incoming waves. Motion sensing is normally done with inertial sensors, which can hinder the motion due to suspended cables that carry power and transmit signals. Our proposed method is contactless and can be implemented economically. A camera is used to record different marker patterns affixed to the moving paddle and the motion deduced by pose estimation algorithms. Fiducial markers are commonly used for robot localization and in augmented reality. There are many types of fiducial markers, including ArUco-type markers which are accurate, fast and robust. The system consists of markers attached to the paddle element and recorded using a machine vision camera. A pose estimation algorithm is then applied to the detected markers to estimate the tilt of the paddle. In this work, we examine the challenges of image acquisition and calibration for underwater targets, compare the motion obtained by this new system with a calibrated tilt sensor and identify areas where the new system may be superior.

computer vision↗

Mass calibration of DES Year-3 clusters via SPT-3G CMB cluster lensing

We measure the stacked lensing signal in the direction of galaxy clusters in the DarkEnergy Survey Year 3 (DES Y3) redMaPPer sample, using cosmic microwave background (CMB)temperature data from SPT-3G, the third-generation CMB camera on the South PoleTelescope (SPT). Here, we estimate the lensing signal using temperature maps constructed fromthe initial 2 years of data from the SPT-3G 'Main' survey, covering 1500 deg$^{2}$ of the Southernsky. We then use this lensing signal as a proxy for the mean cluster mass of the DES sample. Thethermal Sunyaev-Zel'dovich (tSZ) signal, which can contaminate the lensing signal if notaddressed, is isolated and removed from the data before obtaining the mass measurement. In thiswork, we employ three versions of the redMaPPer catalogue: a Flux-Limited sample containing 8865clusters, a Volume-Limited sample with 5391 clusters, and a Volume&Redshift-Limited sample with4450 clusters. For the three samples, we detect the CMB lensing signal at a significance of12.4σ, 10.5σ and 10.2σ and find the mean cluster masses to be M$_{200m}$ = 1.66±0.13 [stat.]± 0.03 [sys.], 1.97±0.18 [stat.]± 0.05 [sys.],and 2.11±0.20 [stat.]± 0.05 [sys.]×10$^{14}$ M$_{⊙}$, respectively. Thisis a factor of ∼ 2 improvement relative to the precision of measurements with previousgenerations of SPT surveys and the most constraining cluster mass measurements using CMB clusterlensing to date. Overall, we find no significant tensions between our results and masses given byredMaPPer mass-richness scaling relations of previous works, which were calibrated using CMBcluster lensing, optical weak lensing, and velocity dispersion measurements from variouscombinations of DES, SDSS and Planck data. We then divide our sample into 3 redshift and 3richness bins, finding no significant discrepancies with optical weak-lensing calibrated masses inthese bins. We forecast a 5.7% constraint on the mean cluster mass of the DES Y3 sample withthe complete SPT-3G surveys when using both temperature and polarization data and including anadditional ∼ 1400 deg$^{2}$ of observations from the 'Extended' SPT-3G survey.

79 ASTRONOMY AND ASTROPHYSICS↗

Calibration of a versatile multi-energy soft x-ray diagnostic for WEST long pulse plasmas

A compact multi-energy soft x-ray diagnostic is being installed on the W Environment in Steady-state Tokamak (WEST), which was designed and built to test ITER-like tungsten plasma facing components in a long pulse (~1000 s) scenario. The diagnostic consists of a pinhole camera fielded with the PILATUS3 photon-counting Si-based detector (≲100 kpixel). The detector has sensitivity in the range 1.6–30 keV and enables energy discrimination, providing a higher energy resolution than conventional systems with metal foils and diodes with adequate space and time resolution (≲1 cm and 2 ms). The lower-absorption cut-off energy is set independently on each one of the ~100 kpixels, providing a unique opportunity to measure simultaneously the plasma emissivity in multiple energy ranges and deduce a variety of plasma parameters (e.g., T e , n Z , and ΔZ eff ). The energy dependence of each pixel is calibrated here over the range 3–22 keV. The detector is exposed to a variety of monochromatic sources—fluorescence emission from metallic targets—and for each pixel, the lower energy threshold is scanned to calibrate the energy dependence. The data are fit to a responsivity curve (“S-curve”) that determines the mapping between the possible detector settings and the energy response for each pixel. Here, the calibration is performed for three energy ranges: low (2.3–6 keV), medium (4.5–13.5 keV), and high (5.4–21 keV). We determine the achievable energy resolutions for the low, medium, and high energy ranges as 330 eV, 640 eV, and 950 eV, respectively. The main limitation for the energy resolution is found to be the finite width of the S-curve.

47 OTHER INSTRUMENTATION↗

Streaked Sub-ps-resolution X-ray Line Shapes and Implications for Solid-density Plasma Dynamics

A high-resolution x-ray spectrometer was coupled with an ultrafast x-ray streak camera to produce time-resolved line shape spectra measured from hot, solid-density plasmas. A Bragg crystal was placed near a laser-produced plasma to maximize throughput; alignment tolerances were established by raytracing. The streak camera produced single-shot time-resolved spectra, heavily sloped due to photon time-of-flight differences, with sufficient reproducibility to accumulate photon statistics. The images are time-calibrated by the slope of streaked spectra and dewarped to generate spectra emitted at different times defined at the source. The streaked spectra demonstrate the evolution of spectral shoulders and other features on ps timescales, showing the feasibility of plasma parameter measurements on the rapid timescales necessary to study high-energy-density plasmas.

High-energy-density plasmas↗

Test GammaPix™ Radiation Detection Software with Smartphones

GammaPix™ is a smartphone application that uses smartphone cameras to detect ionizing radiation. Brookhaven National Laboratory (BNL) evaluated the performance of the software in detecting radioactive materials. For this purpose, a series of tests were conducted at the Radiation Calibration Facility Annex at BNL. The experiments included dose measurements with three types of NIST-traceable calibration sources, 60Co, 241Am, and 137Cs. The recorded results by GammaPix™ were compared with the values measured by calibrated dosimeters to determine the detection thresholds. Several selected models of iPhones and Android cell phones with different pixel sizes and resolution were tested. In this paper, we present the test procedures and discuss the test results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experiments and numerical modeling of surrogate droplet combustion for a 93 octane gasoline calibration fuel

Gasoline is the world’s most prolific liquid transportation fuel for ground transportation vehicles. Yet, a fundamental understanding of its burning characteristics is still lacking. Complicating this matter is the highly multicomponent nature of gasoline (comprised of hundreds of chemical species) and the seasonable variability of its composition due to variations in the crude oil feedstocks used in refining. The need to bring order to this complex problem has led to development of calibration fuels (Tier II in presented study) which on average will provide repeatable metrics that replicate performance of refined gasoline for various engine designs. This study presents results of experiments using the configuration of an isolated droplet to study the combustion dynamics of calibration fuel and three different surrogates (S4, S5, S6) for the calibration fuel. Droplet burning is under microgravity conditions, where gas transport is determined entirely by fuel evaporation in order to promote spherical symmetry in the burning process. The initial droplet diameters ranged between 0.55 mm and 0.60 mm. The droplets were spark-ignited and their burning histories were recorded by digital video cameras to obtain quantitative data. For each fuel, the evolutions of droplet, flame, and soot-shell diameters were measured to calculate the burn rates, flame-droplet diameter ratios (FSR) and soot-droplet diameter ratios. Additionally, a detailed numerical modeling is presented. This simulation includes multicomponent phase equilibrium, unsteady gas and liquid transport, radiative heat transfer, internal liquid diffusion and detailed combustion chemistry of different fuels during their burning process. Experiment results show that the calibration fuel and surrogates have a close burn rates and FSR, and S5 presents a relatively similar results with calibration fuel. Predictions from the numerical simulation using the surrogate are compared with experiment measurements, which showed a good agreement with the experiment results, including the droplet burning rate and FSR.

Guo, Songtao↗