Search NASA⌕ Search

SEARCH · Search NASA

Results for “Canister”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Mission Design Overview for Mars 2003/2005 Sample Return Mission

In May 2003, a new and exciting chapter in Mars exploration will begin with the launch of the first of three spacecraft that will collectively contribute toward the goal of delivering samples from the Red Planet to Earth. This mission is called Mars Sample Return (MSR) and will utilize both the 2003 and 2005 launch opportunities with an expected sample return in October 2008. NASA and CNES are major partners in this mission. The baseline mission mode selected for MSR is Mars orbit rendezvous (MOR), analogous in concept to the lunar orbit rendezvous (LOR) mode used for Apollo in the 1960s. Specifically, MSR will employ two NASA-provided landers of nearly identical design and one CNES-provided orbiter carrying a NASA payload of rendezvous sensors, orbital capture mechanisms, and an Earth entry vehicle (EEV). The high-level concept is that the landers will launch surface samples into Mars orbit, and the orbiter will retrieve the samples in orbit and then carry them back to Earth. The first element to depart for Mars will be one of the two landers. Currently, it is proposed that an intermediate class launch vehicle, such as the Boeing Delta 3 or Lockheed Martin Atlas 3A, will launch this 1800-kg lander from Cape Canaveral during the May 2003 opportunity. The lander will utilize a Type-1 transfer trajectory with an arrival at Mars in mid-December 2003. Landing will be aided by precision approach navigation and a guided hypersonic entry to achieve a touchdown accuracy of 10 km or better. Although the exact landing site has not yet been determined, it is estimated that lander resource constraints will limit the site to between 15 degrees north and south latitudes. Following touchdown, the lander will deploy a six-wheeled, 60-kg rover carrying an extensive suite of instruments designed to aid in the analysis of the local terrain and collection of core samples from selected rocks. The surface mission is currently designed around a concept called the surface traverse. Each traverse will involve the rover exploring a selected area of terrain up to 100 meters from the lander, the collection of rock core samples, and the delivery of the samples from the traverse back to a sample canister on the lander. Planning estimates indicate that up to three traverses may be possible during the expected 90-sol lifetime of the lander. The canister that will receive the samples from the rover will be attached to the top stage of a small solid-fueled rocket mounted to the deck of the lander. This rocket is called the Mars Ascent Vehicle (MAV) and consists of three stages weighing a total of about 140 kg. After the conclusion of the surface mission, the MAV will lift-off and insert the sample canister into a near-circular orbit with an altitude of about 600 km and inclination of 45 degrees. The sample canister will wait in this orbit until it is retrieved by the orbiter sometime in early 2007. In August 2005, the second lander and a CNES-provided orbiter weighing 2700 kg will depart for Mars. Currently, it is proposed that a single Ariane 5 provided by CNES will launch both of these two elements onto a Type-2 transfer trajectory. Although the orbiter and lander will be launched together, they will separate shortly after injection and will fly to Mars as two independent spacecraft. However, both spacecraft will perform a maneuver between 10 and 15 days after launch so that their arrival times at Mars differ by between 12 and 24 hours. This scheme will reduce the operational complexity at the encounter date. A set of four 60-kg surface probes will ride piggyback on the orbiter to Mars. These CNES-provided probes are called Netlanders and will serve as surface stations for scientific investigations independent of the Mars Sample Return goals. Starting approximately one month prior to arrival at Mars, the orbiter will begin to release the Netlanders one at a time. Each release cycle will take several days, and will include time for precision navigation to execute one or two maneuvers that will target the Netlanders to their proper landing site. All four deployment cycles will be completed prior to 10 days before arrival. Both the orbiter and lander will arrive in late-July 2006. Upon arrival, the lander will perform a precision landing and surface mission similar in concept to the one that was executed during the 2003 opportunity. Although the landing site for the 2005 opportunity has not been selected, it is expected to be different from the 2003 site to enhance the diversity of the collected samples. The orbiter's arrival at Mars will be highlighted by the first use of aerocapture to insert a spacecraft into a capture orbit around another planet. The choice of aerocapture, as opposed to a propulsive orbit insertion, was considered mission enabling due to a reduction of over 2000 m/s in mission AV. Aerocapture will be targeted to produce a 250 km x 1400 km capture orbit with an inclination of 45 degrees. Current analysis indicates that achieving this goal will require approximately six minutes of flight deep in the atmosphere with a targeted periapsis of approach of about 43 km. After factoring into account the penalty for carrying a heat shield to survive aerocapture, the net savings compared to a propulsive orbital insertion amounts to several hundred kilograms.

Lee, Wayne J.↗

NEA Multi-Chamber Sample Return Container with Hermetic Sealing

A sample return container is being developed by Honeybee Robotics to receive samples from a derivative of the Champollion/ST4 Sample Acquisition and Transfer Mechanism or other samplers such as the 'Touch and Go' Surface Sampler (TGSS), and then hermetically seal the samples for a sample return mission. The container is enclosed in a phase change material (PCM) chamber to prevent phase change during return and re-entry to earth. This container is designed to operate passively with no motors and actuators. Using the rotation axis of the TGSS sampler for interfacing, transferring and sealing samples, the container consumes no electrical power and therefore minimizes sample temperature change. The circular container houses multiple isolated canisters, which will be sealed individually for samples acquired from different sites or depths. The TGSS based sampler indexes each canister to the sample transfer position, below the index interface for sample transfer. After sample transfer is completed, the sampler indexes a seal carrier, which lines up seals with the openings of the canisters. The sampler moves to the sealing interface and seals the sample canisters one by one. The sealing interface can be designed to work with C-seals, knife edge seals and cup seals. This sample return container is being developed by Honeybee Robotics in collaboration with the JPL Exploration Technology program. A breadboard system of the sample return container has been recently completed and tested. Additional information is contained in the original extended abstract.

Rafeek, Shaheed↗

A Sample Return Container with Hermetic Seal

A sample return container is being developed by Honeybee Robotics to receive samples from a derivative of the Champollion/ST4 Sample Acquisition and Transfer Mechanism or other samplers and then hermetically seal samples for a sample return mission. The container is enclosed in a phase change material (PCM) chamber to prevent phase change during return and re-entry to earth. This container is designed to operate passively with no motors and actuators. Using the sampler's featured drill tip for interfacing, transfer-ring and sealing samples, the container consumes no electrical power and therefore minimizes sample temperature change. The circular container houses a few isolated canisters, which will be sealed individually for samples acquired from different sites or depths. The drill based sampler indexes each canister to the sample transfer position, below the index interface for sample transfer. After sample transfer is completed, the sampler indexes a seal carrier, which lines up seals with the openings of the canisters. The sampler moves to the sealing interface and seals the sample canisters one by one. The sealing interface can be designed to work with C-seals, knife edge seals and cup seals. Again, the sampler provides all sealing actuation. This sample return container and co-engineered sample acquisition system are being developed by Honeybee Robotics in collaboration with the JPL Exploration Technology program.

Kin Yuen Kong↗

Results of the International Space Station Interim Resistance Exercise Device Man-in-the-Loop Test

The Interim Resistance Exercise Device (iRED), developed for the International Space Station (ISS), was evaluated using human subjects for a Man-In-The-Loop Test (MILT). Thirty-two human subjects exercised using the iRED in a test that was conducted over a 63-working-day period. The subjects performed the same exercises will be used on board ISS, and the iRED operating constraints that are to be used on ISS were followed. In addition, eight of the subjects were astronauts who volunteered to be in the evaluation in order to become familiar with the iRED and provide a critique of the device. The MILT was scheduled to last for 57,000 exercise repetitions on the iRED. This number of repetitions was agreed to as a number typical of that expected during a 3-person, 17-week ISS Increment. One of the canisters of the iRED failed at the 49,683- repetition mark (87.1% of targeted goal). The remaining canister was operated using the plan for operations if one canister fails during flight (contingency operations). This canister remained functional past the 57,000-repetition mark. This report details the results of the iRED MILT, and lists specific recommendations regarding both operation of the iRED and future resistance exercise device development.

Moore, A. D., Jr.↗

Genesis Preliminary Examination: Ellipsometry Overview

The Genesis spacecraft returned to Earth on September 8, 2004, experiencing a non-nominal reentry in which both the drogue and main parachutes failed to deploy causing the capsule to impact the surface of the UTTR desert at a speed of approximately 310 kph (193 mph). The impact caused severe damage to the capsule and a breach of the science canister in the field. The science canister was recovered and transported to the cleanroom at UTTR within approximately 8 hours of reentry. Although the ground water table did not rise to canister level before removal, damp soil and debris from the heat shield and other spacecraft components did enter the canister and contaminate some collector surfaces. The objective of preliminary examination of the Genesis collectors is to provide the science community with the information necessary to request the most useful samples for their analysis.

Stansbery, E. K.↗

ISS External Microorganisms: Collecting Planetary Protection Samples During Extravehicular Activity

Introduction: We have designed1, built, and tested a sampling kit (Fig. 1) to aseptically collect microbiological samples from exterior surfaces on the ISS (International Space Station). The kit was flown to ISS as part of the NG-19 commercial cargo mission in August of 2023. Astronauts will use the kit to collect samples from six exterior surfaces on ISS. These samples will be frozen at -80°C after collection and returned to the ground for next generation DNA sequencing. The results of this experiment will help inform planetary protection requirements for crewed missions. We hypothesize that there are detectable microbial communities outside ISS and that these communities originate from inside ISS. Current life support systems do not include any components for reducing microbial leakage. Gases are vented from inside ISS without filtration and there are currently no protocols in place to minimize bioburden on space suit exteriors prior to use. It is important to quantify the bioburden on current vehicles so that achievable limits can be set for crewed missions to astrobiologically relevant locations like Mars. Figure 1: The sampling kit contains eight swab canisters in total (six on the top and two on the bottom). A resuable end effector (1) is used to remove and reinstall the swabs. The kit also contains a handrail (2), tether loop (3), and, bayonet probes(4) to allow easy manipulation during EVA. Methods: We have designed a kit to carry 8 commercially available foam swabs into and out of vacuum without compromising the swabs’ sterility. The specially designed swab canisters contain a 0.2 µm Teflon filter that allows the canister to accommodate pressure changes without introducing unwanted contaminants. The kit meets existing EVA (Extravehicular Activity) safety requirements and has been used by human test subjects in the neutral buoyance lab and at vacuum in test chambers at the Johnson Space Center. In the early part of 2024, astronauts will use this sampling kit to swab six surfaces on the exterior of ISS. We will collect samples from: the airlock vestibule, the interior surface of the airlock thermal cover, an exterior handrail, a vent connected to the CO2 removal system, and a vent connected to the payload vacuum system inside ISS. Approximately 300 cm2 will be swabbed at each location. A seventh swab will be exposed to the vacuum of space without touching any surfaces as a blank. The eighth swab will remain sealed as a process control. After the EVA the swab kit will be frozen at -80°C and returned to earth at the earliest possible opportunity. The samples will remain frozen until they are thawed for next generation DNA sequencing on earth. We will use amplicon sequencing to identify any bacteria, archaea or fungi present in the samples. If there is enough DNA present, we will use shotgun metagenomic sequencing to further characterize the microbial ecology outside ISS. Preliminary Results: Results from ground-based testing demonstrate that the swab kit is capable of cycling in and out of vacuum without contaminating the swabs. Test subjects, wearing flight-like EVA gloves could remove swabs from the canister and sample discrete locations without inadvertently touching any other surfaces. Several types of bacteria and fungi were collected during these ground tests and survived up to 6 hours at vacuum. This includes non-spore forming bacterial like Staphyloccus capitis that are not traditionally considered extremophiles. Shotgun metagenomic sequencing of the ground-test samples revealed bacteria associated with human skin and airways on the exterior of space suits used during these tests 2 In addition to these results we will present preliminary results from our space-flight samples. We will also present lessons learned from attempting to collect microbiological samples during an EVA and describe how our results will affect planetary protection requirements for future crewed missions.

Aaron B. Regberg↗

ISS External Microorganisms: Collecting Planetary Protection Samples During Extravehicular Activity

Introduction: We have designed1, built, and tested a sampling kit (Fig. 1) to aseptically collect microbiological samples from exterior surfaces on the ISS (International Space Station). The kit was flown to ISS as part of the NG-19 commercial cargo mission in August of 2023. Astronauts will use the kit to collect samples from six exterior surfaces on ISS. These samples will be frozen at -80°C after collection and returned to the ground for next generation DNA sequencing. The results of this experiment will help inform planetary protection requirements for crewed missions. We hypothesize that there are detectable microbial communities outside ISS and that these communities originate from inside ISS. Current life support systems do not include any components for reducing microbial leakage. Gases are vented from inside ISS without filtration and there are currently no protocols in place to minimize bioburden on space suit exteriors prior to use. It is important to quantify the bioburden on current vehicles so that achievable limits can be set for crewed missions to astrobiologically relevant locations like Mars. Figure 1: The sampling kit contains eight swab canisters in total (six on the top and two on the bottom). A resuable end effector (1) is used to remove and reinstall the swabs. The kit also contains a handrail (2), tether loop (3), and, bayonet probes(4) to allow easy manipulation during EVA. Methods: We have designed a kit to carry 8 commercially available foam swabs into and out of vacuum without compromising the swabs’ sterility. The specially designed swab canisters contain a 0.2 µm Teflon filter that allows the canister to accommodate pressure changes without introducing unwanted contaminants. The kit meets existing EVA (Extravehicular Activity) safety requirements and has been used by human test subjects in the neutral buoyance lab and at vacuum in test chambers at the Johnson Space Center. In the early part of 2024, astronauts will use this sampling kit to swab six surfaces on the exterior of ISS. We will collect samples from: the airlock vestibule, the interior surface of the airlock thermal cover, an exterior handrail, a vent connected to the CO2 removal system, and a vent connected to the payload vacuum system inside ISS. Approximately 300 cm2 will be swabbed at each location. A seventh swab will be exposed to the vacuum of space without touching any surfaces as a blank. The eighth swab will remain sealed as a process control. After the EVA the swab kit will be frozen at -80°C and returned to earth at the earliest possible opportunity. The samples will remain frozen until they are thawed for next generation DNA sequencing on earth. We will use amplicon sequencing to identify any bacteria, archaea or fungi present in the samples. If there is enough DNA present, we will use shotgun metagenomic sequencing to further characterize the microbial ecology outside ISS. Preliminary Results: Results from ground-based testing demonstrate that the swab kit is capable of cycling in and out of vacuum without contaminating the swabs. Test subjects, wearing flight-like EVA gloves could remove swabs from the canister and sample discrete locations without inadvertently touching any other surfaces. Several types of bacteria and fungi were collected during these ground tests and survived up to 6 hours at vacuum. This includes non-spore forming bacterial like Staphyloccus capitis that are not traditionally considered extremophiles. Shotgun metagenomic sequencing of the ground-test samples revealed bacteria associated with human skin and airways on the exterior of space suits used during these tests 2 In addition to these results we will present preliminary results from our space-flight samples. We will also present lessons learned from attempting to collect microbiological samples during an EVA and describe how our results will affect planetary protection requirements for future crewed missions.

Aaron B. Regberg↗

OSIRIS-REx Curation: The First Year with Bennu Samples on Earth

The OSIRIS-REx (Origins, Spectral Interpretation, Resource Identification, and Security – Regolith Explorer) sample return capsule landed on the Utah Test and Training Range (UTTR) on September 24, 2023. Preparations for the curation of the sample from asteroid Bennu inside of this capsule spanned more than a decade. On the morning of landing, the sample return capsule was brought to a temporary cleanroom at UTTR for initial de-integration and connection of the sample canister to a nitrogen gas purge to protect the sample from modification by the terrestrial atmosphere. In the week following landing, the sample canister was flown to Houston while on nitrogen purge, transferred to a nitrogen atmosphere glovebox at NASA Johnson Space Center in which the canister lid was removed revealing small amounts of sample on the inside of the canister lid and avionics deck, some of this sample was allocated rapidly to the mission sample analysis team as “quick look” samples. Next, the Touch-and-Go sample acquisition mechanism (TAGSAM) head was disassembled inside of a specially designed glovebox. A challenge arose during one of the last stages of disassembly when two fasteners resisted being loosened. The curation team was able to remove 70.3 grams of asteroid sample from the TAGSAM head with those fasteners in-place and began initial sample processing which supported long-term curation of hermetically sealed and frozen samples, transfer of some samples to remote storage, and allocation of aggregate samples to the mission sample analysis team. Meanwhile, curation engineers developed a tool to remove the stubborn fasteners without contaminating the remaining sample, enabling the remaining bulk sample to be transferred to long-term storage trays in January 2024. With this second part of the bulk sample, the returned bulk asteroid sample reached 121.6 grams. During disassembly and prior to sealing the bulk sample trays into long-term storage containers, archival photographs were collected. Select particles are gradually being XCT scanned while inside of containers that hold a nitrogen atmosphere. The initial OSIRIS-REx sample catalog was released in spring 2024 with an update in fall 2024. The curation team will be busy working to allocate samples to scientists around the world for the foreseeable future.

Curation↗

Regenerable metallic oxide systems for removal of carbon dioxide: A concept

Design concepts for portable canisters for removal of carbon dioxide are described. One is screen pack configuration consisting of brazed rectangular canister with four metal oxide packs inserted. Other is radial flow canister with perforated central tube. Methods of production and operating principles are presented.

Sutton, J. G.↗

Development of a low temperature phase change material package

Test data obtained for a low temperature phase change material (PCM) canisters are presented. The canister was designed to provide up to 30 w-hrs of storage capacity at approximately -90 C with an overall thermal conductance which is greater than 8 w/deg C. N-heptane which is an n-paraffin and has a -90.6 C freezing point was used as the working fluid. The canister was fabricated from aluminum and has an aluminum honeycomb core. Its void volume permits service temperatures up to 70 C. Results obtained from component and system's tests indicate well defined melting and freezing points which are repeatable and within 1 C of each other. Subcooling effects are less than 0.5 C and are essentially negligible. Measured storage capacities are within 94 to 88% the theoretical.

Brennan, P. J.↗

A new approach to helicopter rotor blade research instrumentation

A rotor-blade-mounted telemetry instrumentation system developed and used in flight tests by the NASA/Langley Research Center is described. The system uses high-speed digital techniques to acquire research data from miniature pressure transducers on advanced rotor airfoils which are flight tested using an AH-1G helicopter. The system employs microelectronic PCM multiplexer-digitizer stations located remotely on the blade and in a hub-mounted metal canister. The electronics contained in the canister digitizes up to 16 sensors, formats this data with serial PCM data from the remote stations, and transmits the data from the canister which is above the plane of the rotor. Data is transmitted over an RF link to the ground for real-time monitoring and to the helicopter fuselage for tape recording.

Knight, V. H., Jr.↗

A systems-level performance history of get away specials after 25 space shuttle missions

Summarized are the results of a thorough performance study of Get Away Special (GAS) payloads conducted in 1986. During the study, a complete list of standard and non-standard GAS payloads vs. Shuttle mission was constructed, including specific titles for the experiments in each canister. A broad data base for each canister and each experiment was then compiled. Performance results were then obtained for all but a few experiments. The canisters and experiments were subsequently categorized according to the degree of experiment success. For those experiments experiencing failures or anomalies, several correlations and generalizations were extracted from individual subsystem performance data. Recommendations are made which may enhance the success and performance of future GAS payloads.

Ridenoure, Rex W.↗

A systems-level performance history of get away specials after 25 Space Shuttle missions

This paper summarizes the results of a thorough performance study of Get Away Special (GAS) payloads that was conducted in 1986. During the study a complete list of standard and nonstandard GAS payloads vs. Shuttle mission was constructed, including specific titles for the experiments in each canister. A broad data base for each canister and each experiment was then compiled. Performance results were then obtained for all but a few experiments. The canisters and experiments were subsequently categorized according to the degree of experiment success. For those experiments that experienced failures or anomalies, several correlations and generalizations were extracted from individual subsystem performance data. Recommendations are made which may enhance the success and performance of future GAS payloads.

Ridenoure, Rex W.↗

Design of a cavity heat pipe receiver experiment

A cavity heat pipe experiment has been designed to test the critical issues involved with incorporating thermal energy storage canisters into a heat pipe. The experiment is a replication of the operation of a heat receiver for a Brayton solar dynamic power cycle. The heat receiver is composed of a cylindrical receptor surface and an annular heat pipe with thermal energy storage canisters and gaseous working fluid heat exchanger tubes surrounding it. Hardware for the cavity heat pipe experiment will consist of a sector of the heat pipe, complete with gas tube and thermal energy storage canisters. Thermal cycling tests will be performed on the heat pipe sector to simulate the normal energy charge/discharge cycle of the receiver in a spacecraft application.

Schneider, Michael G.↗

Radiation and phase change of lithium fluoride in an annulus

A one-dimensional thermal model is developed to evaluate the effect of radiation on the phase change of lithium-fluoride (LiF) in an annular canister under gravitational and microgravitational conditions. Specified heat flux at the outer wall of the canister models focused solar flux; adiabatic and convective conditions are considered for the inner wall. A two-band radiation model is used for the combined-mode heat transfer within the canister, and LiF optical properties relate metal surface properties in vacuum to those in LiF. For axial gravitational conditions, the liquid LiF remains in contact with the two bounding walls, whereas a void gap is used at the outer wall to model possible microgravitational conditions. For the adiabatic cases, exact integrals are obtained for the time required for complete melting of the LiF. Melting was found to occur primarily from the outer wall in the 1-g model, whereas it occurred primarily from the inner wall in the mu-g model. For the convective cases, partially melted steady-state conditions and fully melted conditions are determined to depend on the source flux level, with radiation extending the melting times.

Lund, Kurt O.↗

Performance and durability of high emittance heat receiver surfaces for solar dynamic power systems

Haynes 188, a cobalt-based superalloy, will be used to make thermal energy storage (TES) containment canisters for a 2 kW solar dynamic ground test demonstrator (SD GTD). Haynes 188 containment canisters with a high thermal emittance (epsilon) are desired for radiating heat away from local hot spots, improving the heating distribution, which will in turn improve canister service life. In addition to needing a high emittance, the surface needs to be durable in an elevated temperature, high vacuum environment for an extended time period. Thirty-five Haynes 188 samples were exposed to 14 different types of surface modification techniques for emittance and vacuum heat treatment (VHT) durability enhancement evaluation. Optical properties were obtained for the modified surfaces. Emittance enhanced samples were exposed to VHT for up to 2692 hours at 827 C and less than or equal to 10(exp -6) torr with integral thermal cycling. Optical properties were taken intermittently during exposure, and after final VHT exposure. The various surface modification treatments increased the emittance of pristine Haynes 188 from 0.11 up to 0.86. Seven different surface modification techniques were found to provide surfaces which met the SD GTD receiver VHT durability requirement. Of the 7 surface treatments, 2 were found to display excellent VHT durability: an alumina based (AB) coating and a zirconia based coating. The alumina based coating was chosen for the epsilon enhancement surface modification technique for the SD GTD receiver. Details of the performance and vacuum heat treatment durability of this coating and other Haynes 188 emittance surface modification techniques are discussed. Technology from this program will lead to successful demonstration of solar dynamic power for space applications, and has potential for application in other systems requiring high emittance surfaces.

Degroh, Kim K.↗

Preliminary results of radiation measurements on EURECA

The eleven-month duration of the EURECA mission allows long term radiation effects to be studied similarly to those of the Long Duration Exposure Facility (LDEF). Basic data can be generated for projections of crew doses and electronic and computer reliability on spacecraft missions. A radiation experiment has been designed for EURECA which uses passive integrating detectors to measure average radiation levels. The components include a Trackoscope, which employs fourteen plastic nuclear track detector (PNTD) stacks to measure the angular dependence of LET (greater than or equal to 6 keV/microns) radiation. Also included are TLD's for total absorbed doses, thermal/resonance neutron detectors (TRND's) for low energy neutron fluences and a thick PNTD stack for depth dependence measurements. LET spectra are derived from the PNTD measurements. Preliminary TLD results from seven levels within the detector array show that integrated doses inside the flight canister varied from 18.8 plus or minus 0.6 cGy to 38.9 plus or minus 1.2 cGy. The TLD's oriented toward the least shielded direction averaged 53 percent higher in dose than those oriented away from the least shielded direction (minimum shielding toward the least shielded direction varied from 1.13 to 7.9 g/cm(exp 2), Al equivalent). The maximum dose rate on EURECA (1.16 mGy/day) was 37 percent of the maximum measured on LDEF and dose rates at all depths were less than measured on LDEF. The shielding external to the flight canister covered a greater solid angle about the canister than in the LDEF experiments.

Benton, E. V.↗

Preliminary results of radiation measurements on EURECA

The eleven-month duration of the EURECA mission allows long-term radiation effects to be studied similarly to those of the Long Duration Exposure Facility (LDEF). Basic data can be generated for projections to crew doses and electronic and computer reliability on spacecraft missions. A radiation experiment has been designed for EURECA which uses passive integrating detectors to measure average radiation levels. The components include a Trackoscope, which employs fourteen plastic nuclear track detector (PNTD) stacks to measure the angular dependence of high LET (greater than or equal to 6 keV/micro m) radiation. Also included are TLD's for total absorbed doses, thermal/resonance neutron detectors (TRND's) for low energy neutron fluences and a thick PNTD stack for depth dependence measurements. LET spectra are derived from the PNTD measurements. Preliminary TLD results from seven levels within the detector array show that integrated does inside the flight canister varied from 18.8 +/- 0.6 cGy to 38.9 +/- 1.2 cGy. The TLD's oriented toward the least shielded direction averaged 53% higher in dose than those oriented away from the least shielded direction (minimum shielding toward the least shielded direction varied from 1.13 to 7.9 g/cm(exp 2), Al equivalent). The maximum dose rate on EURECA (1.16 mGy/day) was 37% of the maximum measured on LDEF and dose rates at all depths were less than measured on LDEF. The shielding external to the flight canister covered a greater solid angle about the canister than the LDEF experiments.

Benton, E. V.↗