Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cell viability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Pot1 promotes telomere DNA replication via the Stn1-Ten1 complex in fission yeast

Abstract Telomeres are nucleoprotein complexes that protect the chromosome-ends from eliciting DNA repair while ensuring their complete duplication. Pot1 is a subunit of telomere capping complex that binds to the G-rich overhang and inhibits the activation of DNA damage checkpoints. In this study, we explore new functions of fission yeast Pot1 by using a pot1-1 temperature sensitive mutant. We show that pot1 inactivation impairs telomere DNA replication resulting in the accumulation of ssDNA leading to the complete loss of telomeric DNA. Recruitment of Stn1 to telomeres, an auxiliary factor of DNA lagging strand synthesis, is reduced in pot1-1 mutants and overexpression of Stn1 rescues loss of telomeres and cell viability at restrictive temperature. We propose that Pot1 plays a crucial function in telomere DNA replication by recruiting Stn1-Ten1 and Polα-primase complex to telomeres via Tpz1, thus promoting lagging-strand DNA synthesis at stalled replication forks.

Carvalho Borges, Pâmela C. (ORCID:0000000244919874↗

Protective Effect of Phloretin against Hydrogen Peroxide-Induced Oxidative Damage by Enhancing Autophagic Flux in DF-1 Cells

Phloretin (PHL) is a dihydrochalcone flavonoid isolated from the peel and root bark of apples, strawberries, and other plants with antioxidative characteristic. In this study, we aimed to investigate the protective effect and the potential mechanism of PHL on hydrogen peroxide (H2O2)-induced oxidative damage in DF-1 cells. The results showed that PHL exhibited no cytotoxic effect on DF-1 cells at concentration below 20 μM. PHL markedly increased H2O2-reduced cell viability, decreased H2O2-induced apoptosis, as evidenced by reduced apoptosis rate, the upregulation of gene and protein level of Bcl-2, and the downregulation of gene and protein level of Bax and Cleaved caspase3. In addition, PHL reduced H2O2-induced reactive oxygen species (ROS) production and restored antioxidant enzymes activities as well as mitochondrial membrane potential in a dose-dependent manner. Moreover, PHL prior to H2O2 further increased LC3-II level, promoted p62 turnover and improved lysosomal function. Importantly, autophagy inhibitor chloroquine (CQ) reversed the protective effect of PHL, and increased H2O2-induced apoptosis. Furthermore, PHL inhibited the phosphorylation levels of ERK, p38, and JNK. Collectively, these results indicate that PHL could attenuate H2O2-induced oxidative injury and apoptosis by maintaining lysosomal function and promoting autophagic flux, and MAPKs pathway may be involved in this process. Our study provides evidence that PHL could as a new strategy to against oxidative damage in poultry industry.

Song, Dan↗

Improving tolerance of yeast to lignocellulosic-derived feedstocks and products

Combined substrate-product toxicity remains one of the main obstacles hampering the scale-up and cost-effectiveness of bioprocesses harnessing lignocellulosic feedstocks, the most abundant, renewable terrestrial resource. Hydrolytic pretreatments release numerous inhibitors impinging on cell viability: the three most acute to yeast S. cerevisiae (the industry dominant biocatalyst) — and universal to all plant sources — are furfural, hydroxymethylfurfural (HMF), and acetic acid. Likewise, desired fermentation products, such as fuel ethanol or commodity organic acids, are toxic to microbes, typically via unknown biological mechanisms. Here, we have engineered both hydrolysate and end-product tolerance in yeast by combining previously-shown alcohol protective modifications with evolved genetic activities targeting the major pretreatment inhibitors. When tested on a wide sampling of genuine lignocellulosic feedstocks, ethanol production increased by >30% on average to titers >100 g/L, achieving parity with clean-sugar equivalents where conditions permit. Furthermore, we designed the tolerance capability to be fully transferable to pre-existing metabolic chassis strains. As such, we “drop-in” hydrolysate competence into one producing lactic acid, demonstrating the first-ever production of a cellulosic plastic at industrial titers. Our advances thus renew the potential of cellulosic biomass utilization for sustainable fuel and non-fuel products at scale.

09 BIOMASS FUELS↗

Enhanced Corneal Penetration of a Poorly Permeable Drug Using Bioadhesive Multiple Microemulsion Technology

Corneal penetration is a key rate limiting step in the bioavailability of topical ophthalmic formulations that incorporate poorly permeable drugs. Recent advances have greatly aided the ocular delivery of such drugs using colloidal drug delivery systems. Ribavirin, a poorly permeable BCS class-III drug, was incorporated in bioadhesive multiple W/O/W microemulsion (ME) to improve its corneal permeability. The drug-loaded ME was evaluated regarding its physical stability, droplet size, PDI, zeta potential, ultrastructure, viscosity, bioadhesion, in vitro release, transcorneal permeability, cytotoxicity, safety and ocular tolerance. Our ME possessed excellent physical stability, as it successfully passed several cycles of centrifugation and freeze–thaw tests. The formulation has a transparent appearance due to its tiny droplet size (10 nm). TEM confirmed ME droplet size and revealed its multilayered structure. In spite of the high aqueous solubility and the low permeability of ribavirin, this unique formulation was capable of sustaining its release for up to 24 h and improving its corneal permeability by 3-fold. The in vitro safety of our ME was proved by its high percentage cell viability, while its in vivo safety was confirmed by the absence of any sign of toxicity or irritation after either a single dose or 14 days of daily dosing. Our ME could serve as a vehicle for enhanced ocular delivery of drugs with different physicochemical properties, including those with low permeability.

Ibrahim, Mohamed Moustafa↗

Effect of Foot-and-Mouth Disease Virus 2B Viroporin on Expression and Extraction of Mammalian Cell Culture Produced Foot-and-Mouth Disease Virus-like Particles

To improve the production of foot-and-mouth disease (FMD) molecular vaccines, we sought to understand the effects of the FMD virus (FMDV) 2B viroporin in an experimental, plasmid-based, virus-like particle (VLP) vaccine. Inclusion of the FMDV viroporin 2B into the human Adenovirus 5 vectored FMD vaccine enhanced transgene expression despite independent 2B expression negatively affecting cell viability. Evaluating both wildtype 2B and mutants with disrupted viroporin activity, we confirmed that viroporin activity is detrimental to overall transgene expression when expressed independently. However, the incorporation of 2B into an FMD molecular vaccine construct containing a wildtype FMDV 3C protease, a viral encoded protease responsible for processing structural proteins, resulted in enhancement of transgene expression, validating previous observations. This benefit to transgene expression was negated when using the FMDV 3CL127P mutant, which has reduced processing of host cellular proteins, a reversion resulting from 2B viroporin activity. Inclusion of 2B into VLP production constructs also adversely impacted antigen extraction, a possible side effect of 2B-dependent rearrangement of cellular membranes. These results demonstrate that inclusion of 2B enhanced transgene expression when a wildtype 3C protease is present but was detrimental to transgene expression with the 3CL127P mutant. This has implications for future molecular FMD vaccine constructs, which may utilize mutant FMDV 3C proteases.

2B↗

Microbial response to space environment, part B

The performance of the microbial response to space environment experiment is considered excellent by all investigators. For most microbial systems, only preliminary survival data are available at this time. None of the available data indicate space flight-mediated changes in cell viability or recovery. One quite important observation has been made at this early date, however. The eggs produced after mice had been infected with N. dubius larvae demonstrated a significant decrease in hatchability when compared to identical ground controls. Except for the fact that the Apollo 16 flight larvae had been on board the command module, treatment of the flown larvae and ground control larvae was the same; neither had been exposed to UV irradiation. The significance and implications of this finding are currently being studied.

Taylor, G. R.↗

Countercurrent distribution of biological cells

A neutral polymer phase system consisting of 7.5 percent dextran 40/4.5 percent PEG 6, 0.11 M Na phosphate, 5 percent fetal bovine serum (FBS), pH 7.5, was developed which has a high phase droplet electrophoretic mobility and retains cell viability over many hours. In this and related systems, the drop mobility was a linear function of drop size, at least in the range 4-30 micron diameter. Applications of and electric field of 4.5 v/cm to a system containing 10 percent v/v bottom phase cleared the system more than two orders of magnitude faster than in the absence of the field. At higher bottom phase concentrations a secondary phenomenon intervened in the field driven separations which resulted in an increase in turbidity after clearing had commenced. The increase was associated with a dilution of the phase system in the chamber. The effect depended on the presence of the electric field. It may be due to electroosmotic flow of buffer through the Amicon membranes into the sample chamber and flow of phase system out into the rinse stream. Strategies to eliminate this problem are proposed.

Brooks, D. E.↗

Investigations on gel forming media use in low gravity bioseparations research

Research on gelling media and conditions suitable for the preservation of the spatial configuration of cell suspensions and macromolecular solutions after separation in free fluid during low gravity experiments is presented. The examples studied included free electrophoresis of cells in a cylindrical column and two-phase aqueous polymer separation. Microgravity electrophoresis experiments were simulated by separating model cell types (animal or human) in a vertical density gradient containing low-conductivity buffer, 1.7-6.5 percent Ficoll, 6.8-5.0 percent sucrose, and 1 percent SeaPrep low-melting temperature agarose. Upon cooling, a gel formed in the column and cells could be captured at the forming locations. Two-phase extraction experiments were simulated using two-polymer solutions in which phase separation occurs in normal saline at temperatures compatible with cell viability and in which one or both phases form a gel upon cooling. Suitable polymers included commercial agaroses (1-2 percent), maltodextrin (5-7 percent), and gelatin (5-20 percent).

Todd, Paul↗

Adaptation of Motility Analysis Apparatus for Space Science and Microgravity Ground-Based Experiments

Previous space flight studies have described unfavorable effects of microgravity on testicular morphology and spermatogenesis (Cosmos 1887 Biosputnik flight, 9/29/87 - 10/12/87). The flight animals demonstrated small reductions in testicular and epididymal size, the phenomenon explained as resulting water loss. Yet, light microscopic histological preparations revealed few spermatozoa in the rete testis of the flight males compared to control animals. The cause for this finding was subjectively assessed to be due to "the anatomical dislocation of the organs... and a disturbance in testicular blood supply". Unfortunately, the reported effects of microgravity on the reproductive processes (particularly within males) are few and divergent. If habitation in space is a futuristic goal, more objective testing (of male and female gametes) in a microgravity environment will provide insight to the developmental potential of these reproductive cells. As part of the Marshall Space Flight Centers' Summer Faculty Fellowship Program within the Biophysics Branch, a key component of the research investigation was to develop a test to evaluate individual cell motility and orientation in varying gravitational environments, using computerized assessment of sperm cell concentration, morphology and motility to provide objective, quantitative experimental control. In previous work performed jointly by the author and a NASA colleague, it has been shown that macroscopic motile aggregates of spermatozoa were not altered by the absence of microgravity. Variations in the number of normal versus abnormal sperm due to microgravity influences have yet to be established. It is therefore of interest to monitor the cytoskeletal matrix (microtubulin) of these organisms as a possible indicator of cell viability and/or function.

Johnson, Jacqueline U.↗

Building Better Biosensors for Exploration into Deep-Space, Using Humanized Yeast

1.BioSentinel is 1 of 13 secondary payloads hitching a ride beyond Low Earth Orbit on Exploration Mission 1 (EM-1), set to launch from NASAs Space Launch System in 2019. EM-1 is our first opportunity to investigate the effects of the deep space environment on a eukaryotic biological system, the budding yeast S. cerevisiae. Though separated by a billion years of evolution we share hundreds of genes important for basic cell function, including responses to DNA damage. Thus, yeast is an ideal biosensor for detecting typesextent of damage induced by deep-space radiation.We will fly desiccated cells, then rehydrate to wake them up when the automated payload is ready to initiate the experiment. Rehydration solution contains SC (Synthetic Complete) media and alamarBlue, an indicator for changes in growth and metabolism. Telemetry of LED readings will then allow us to detect how cells respond throughout the mission. The desiccation-rehydration process can be extremely damaging to cells, and can severely diminish our ability to accurately measure and model cellular responses to deep-space radiation. The aim of this study is to develop a better biosensor: yeast strains that are more resistant to desiccation stress. We will over-express known cellular protectants, including hydrophilin Sip18, the protein disaggregase Hsp104, and thioredoxin Trx2, a responder to oxidative stress, then measure cell viability after desiccation to determine which factors improve stress tolerance. Over-expression of SIP18 in wine yeast starter cultures was previously reported to increase viability following desiccation stress by up to 70. Thus, we expect similar improvements in our space-yeast strains. By designing better yeast biosensors we can better prepare for and mitigate the potential dangers of deep-space radiation for future missions.This work is funded by NASAs AES program.

biosensor↗

Developing High-Throughput Organ-On-A-Chip Models to Investigate the Effects of Ionizing Radiation on the Central Nervous System

One of the main health risks in human space exploration is central nervous system (CNS) damage by ionizing radiation. Irradiation with simulated GCRs or their components, or high doses of low-LET radiation such as gamma rays, in animal models has been shown to cause neuronal damage together with glial cell activation and neuroinflammation and has been associated with prolonged cognitive and behavioral dysfunction. The extent of CNS damage in response to any insult, including ionizing radiation, is partially regulated by the blood-brain barrier (BBB), which enables immune cells to enter the CNS. The main cellular regulators of BBB permeability are astrocytes, which also modulate neuronal death, immune responses and oxidative stress, and thus could serve as a robust CNS-specific target for countermeasure development. However, studies on BBB permeability and astrocyte functions in regulating CNS responses to ionizing radiation have been limited, especially in human tissue/organ analogs. Therefore, we have established a high throughput 3D organ-on-a-chip system to study human CNS functions in response to ionizing radiation, with the eventual goal of adapting it to spaceflight missions. We utilized commercially available OrganoPlate system (Mimetas, Inc.) seeded with primary or induced pluripotent stem cell-derived human cells for developing 3D neuronal-astrocytic and BBB models. We investigated both immediate and delayed CNS dose responses to 0.5-1 Gy X-rays by measuring BBB permeability and morphology, and astrocyte activation. We have also quantified secreted markers of oxidative stress and cell viability. In the future, we are planning to monitor dendritic, axonal and synaptic changes in neurons, evaluate the combined exposures to simulated microgravity and ionizing radiation, and compare the responses to low and high-LET ionizing radiation. We anticipate these studies could indicate novel cellular and mechanistic targets for countermeasure developments to improve CNS functions in astronauts.

Malkani, Sherina↗

A Heritage BioSensor for Lunar Biology Experiments

Introduction: Automated biological experiments on small spacecraft missions have gained prominence over the past decade due to their simplicity, accessibility, and small mass, volume, and power needs. Most recently, the BioSensor microfluidic CubeSat payload aboard BioSentinel used an automated microfluidic cell culture system to study the effects of environmental stressors like deep space radiation and microgravity on yeast growth and metabolism. BioSentinel’s successor, the Lunar Explorer Instrument for space biology Applications (LEIA), will study the effects of lunar gravity and radiation using an improved version of the BioSensor microfluidic platform. The BioSensor payload has great adaptability to host a diverse range of biological experiments with single- and multi-celled organisms in both crewed and uncrewed missions, making it a compelling candidate for future space biology studies in a lunar surface environment. BioSensor Instrumentation on BioSentinel: The first spaceflight mission with the BioSensor, BioSentinel’s biology experiments occurred at three locations -- deep space, ISS and ground. The payload contained 18 microfluidic cards, each featuring 16 growth wells (a total of 288 growth wells). Each well was loaded before launch with desiccated yeast. In space, liquid culture medium (nutrients) was automatically introduced to batches of wells at a time to initiate a series of biology experiments. Temperature was maintained by thin film heaters on both sides of each card. Each well was equipped with three LEDs emitting at 570 nm, 630 nm, and 850 nm, paired with photodetectors to measure cell concentration and the alamarBlue (metabolic indicator dye) color transition from blue to pink. Phenotypic parameters like cell viability, metabolic rate, and generation time can be derived from these measurements. The sequence and timing of fluid fills, optical measurements, and thermal control were stored onboard, but could be updated asynchronously via ground communication. LEIA: LEIA is slated for launch no earlier than 2026 on a CLPS lander. BioSentinel’s BioSensor has been modified for use in LEIA. These improvements include: (a) storage for multiple culture medium types, (b) additional LED color (465 nm) for a new biological assay for antioxidant (carotenoid) production, (c) housing modifications for later biology load before launch, (d) improved isolation between electronic and fluidic components, and (e) improved humidity control for prolonged organism viability in case of post-load launch delay. Future Prospects: The consistent and successful demonstration of complex fluidics platforms alongside reliable instrument operations in a space environment is poised to create strong momentum for BioSensor-based biological experiment payloads. Planned future developments with the BioSensor include extending compatibility to a broader range of organisms and assays. Preliminary work has already demonstrated successful growth of Arabidopsis seedlings in fluidic cards. With a few modifications to the optical assembly, the setup could easily measure photosynthetic traits in plants and cyanobacteria. The addition of fluorescence measurements and generation of novel luminescent assays will elevate BioSensor’s functionality further. Beyond the BioSensor’s potential uses on free-flyer missions, ISS and Gateway, and CLPS landers, deploying the BioSensor to the lunar surface or in an artificial habitat on crewed missions could enable pioneering research on both how life responds to lunar conditions and future bioproduction capabilities making the BioSensor an indispensable tool for future space biology research.

Chinmayee Govinda Raj↗

Electrical sensing, tracking, and actuation of droplets

Devices, techniques, and processes are disclosed that use electrical impedance to detect of the presence and contents of droplets including cells, nucleic acids, proteins, or solute concentrations in an array of retrievable, trackable, trapped droplets in a fluidic system. Electrodes may be positioned underneath individual droplet traps in a microchannel to assay droplet contents and/or actuating droplets for the release of the droplets from corresponding traps. The disclosed technology may be used for detection of the results of solvent extraction processes including time-dependent quantification of metal ion concentration in the aqueous and organic phases, for wastewater treatment, heavy metal detection, pharmaceutical industry, and/or biotechnology, or for environmental monitoring of wastewater for toxic metal, monitoring of biological cell viability and proliferation, monitoring of extraction processes used in heavy metal mining, monitoring of extraction processes used in nuclear fuel processing, monitoring kinetics of enzyme processes, and/or assessing pharmacodynamics and drug efficacy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microwave Sensing of Yeast Cell Species and Viability

We report the development of a simple interferometer-based microwave sensing system for multiple frequency characterization and differentiation of in-flow yeast cells. The interferometer uses a simple microstrip line, integrated with a microfluidic channel, for single-cell measurement. An algorithm was developed and verified with high-frequency structure simulator (HFSS) for complex permittivity, ε*( f ) = ε'( f ) - jε"(f), extraction from measured scattering parameters. The sensing system and the algorithm were evaluated by measuring polystyrene particles of different diameters and at different interferometer operating frequencies. Viable and nonviable Saccharomyces cerevisiae and Saccharomyces pastorianus cells were measured at those frequencies. The results showed frequency-dependent permittivity values for each species of yeast and viability as well as frequency-dependent permittivity differences between different yeast types. The differences at some frequency points are significant and enable the differentiation of cells in mixed suspension, which is also demonstrated with a prediction model developed in this work.

59 BASIC BIOLOGICAL SCIENCES↗

Droplet bioprinting of acellular and cell-laden structures at high-resolutions

Advances in digital light projection(DLP) based (bio) printers have made printing of intricate structures at high resolution possible using a wide range of photosensitive bioinks. A typical setup of a DLP bioprinter includes a vat or reservoir filled with liquid bioink, which presents challenges in terms of cost associated with bioink synthesis, high waste, and gravity-induced cell settling, contaminations, or variation in bioink viscosity during the printing process. Here, we report a vat-free, low-volume, waste-free droplet bioprinting method capable of rapidly printing 3D soft structures at high resolution using model bioinks and model cells. A multiphase many-body dissipative particle dynamics model was developed to simulate the dynamic process of droplet-based DLP printing and elucidate the roles of surface wettability and bioink viscosity. Process variables such as light intensity, photo-initiator concentration, and bioink formulations were optimized to print 3D soft structures (∼0.4–3 kPa) with a typical layer thickness of 50 µm, an XY resolution of 38 ± 1.5 μm and Z resolution of 237 ± 5.4 µm. To demonstrate its versatility, droplet bioprinting was used to print a range of acellular 3D structures such as a lattice cube, a Mayan pyramid, a heart-shaped structure, and a microfluidic chip with endothelialized channels. Droplet bioprinting, performed using model C3H/10T1/2 cells, exhibited high viability (90%) and cell spreading. Additionally, microfluidic devices with internal channel networks lined with endothelial cells showed robust monolayer formation while osteoblast-laden constructs showed mineral deposition upon osteogenic induction. Overall, droplet bioprinting could be a low-cost, no-waste, easy-to-use, method to make customized bioprinted constructs for a range of biomedical applications.

DLP↗

Evaluation of results of cell electrophoresis experiments on space shuttle STS-3 including pre-flight and post-flight laboratory experiments

The objectives of the red blood cell experiments were to provide a visual check on the electrophoretic process and especially electroosmotic flow in space as well as to provide test separations of non-degradable standard particles for comparison with the separations of the three viable cell types studied on the Apollo-Soyuz Test Project. Determination of the maximum concentrations of cells that can be separated in column electrophore was a significant goal. Two of the eight columns were available for red cell experiments, so two concentrations of human and rabbit RBC mixtures were used. The objectives of another experiment were to evaluate the reproducibility of microgravity electrophoretic separation of living kidney cells, to separate cells with highly viability despite two freeze-thaw cycles, and to optimize the physical conditions of cell separation. Owing to the uncertain heterogeneity of the starting material, the experimental design does not assess resolution in microgravity, but improved separability was sought in comparison to density-gradient electrophoresis or continuous-flow electrophoresis. Efforts were made to increase cell yield and cell viability and to assess reproducibility directly.

Todd, P. W.↗

Summer 2015 Internship Abstract

Green fluorescent protein (GFP) visually shows the expression of proteins by fluorescing when exposed to certain wavelengths of light. The GFP in this experiment was used to identify cells actively releasing viruses. The experiment focused on the effect of microgravity on the GFP expression of Akata B-cells infected with Epstein Barr Virus (EBV). Two flasks were prepared with 30 million cells each and two bioreactors were prepared with 50 million cells each. All four cultures were incubated for 16 days and fed every four days. Cellometer readings were taken on the feeding days to find cell size, viability, and GFP expression. In addition, the cells were treated with Propodium monoazide (PMA) and run through real time PCR to determine viral load on the feeding days. On the International Space Station air samples are taken to analyze the bacterial and fungal organisms in the air. The Sartorius Portable Airport is being investigated for potential use on the ISS to analyze for viral content in the air. Multiple samples were taken around Johnson Space Center building 37 and in Clear Lake Pediatric Clinic. The filter used was the gelatin membrane filter and the DNA was extracted directly from the filter. The DNA was then run through real time PCR for Varicella Zoster Virus (VZV) and EBV as well as GAPDH to test for the presence of DNA. The results so far have shown low DNA yield and no positive results for VZV or EBV. Further inquiry involves accurately replicating an atmosphere with high viral load from saliva as would be found on the ISS to run the air sampler in. Another line of research is stress hormones that may be correlated to the reactivation of latent viruses. The stress hormones from saliva samples are analyzed rather than blood samples. The quantity found in saliva shows the quantity of the hormones actually attached to cells and causing a reaction, whereas in the blood the quantity of hormones is the total amount released to cause a reaction. The particular hormones tested for were cortisol, alpha-amylase, and DHEA. The DHEA was very high in the two control samples tested. Regularly, samples came into the lab from local clinics to be tested for various viruses. Saliva, blood, body scrapes, and tears were received from the clinics and then run for VZV, EBV, and Human Simplex Virus 1 (HSV-1) with the results then reported back to the clinician. Blood, saliva, and urine from astronauts were also tested for viruses and logged. In addition, several cell cultures were brought up and grown, including adherent Human Lung Fibroblast (HFL) cells infected with VZV, and Akata B-cells infected with EBV.

Smith, Courtney↗

Both necrosis and apoptosis contribute to HIV-1-induced killing of CD4 cells

BACKGROUND: Data currently available on HIV-1-induced cytopathology is unclear regarding the mechanism of cell killing. OBJECTIVE: To clarify the extent to which apoptosis or necrosis is involved in HIV-1-induced cell death in view of conflicting existing data. METHODS: T lymphoblastoid cells or peripheral blood mononuclear cells were infected by various strains of HIV-1 and the numbers of apoptotic or necrotic cells were quantified at various times after infection using video-image analysis techniques; the results were compared with the amount of fragmented DNA using a quantitative method. Measurement of mitochondrial transmembrane potential (deltapsi(m)) and intracellular calcium concentrations [Ca2+]i was performed with fluorescent probes and fluorescence concentration analysis (FCA). RESULTS: Although lymphoblastoid and monocytoid cells acutely infected by HIV-1 had increased levels of fragmented DNA, a marker of apoptotic cell death, few (<12%) had condensed chromatin and fragmented nuclei, the morphological features of apoptosis. The predominant alterations in acutely infected cells were distended endoplasmic reticulum and abnormal mitochondria; these ultrastructural changes are consistent with necrosis, although some infected cells simultaneously displayed features of both necrosis and apoptosis. Viability of cells persistently infected by HIV-1 was only minimally reduced from that of uninfected cells. This reduction was accounted for by an increased propensity of the persistently infected cells to die by apoptosis. Alterations in [Ca2+]i and deltapsi(m) occurred in both acutely and persistently infected cells. CONCLUSION: Both necrosis and apoptosis contribute to HIV-1-induced killing of CD4 cells.

Non-NASA Center↗