The interaction of charged particles with a turbulent plasma <o vzaimodeystvii zaryazhennykh chastits s turbulentnoy plazmoy<
Charged particles interaction with turbulent plasma
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Charged particles interaction with turbulent plasma
We consider the resonant interaction of energetic charged particles and transverse plasma wave propagating parallel and/or antiparallel to the uniform magnetic field B(sub 0) in an underlying background plasma of density n. The coupling of the plasma waves and the energetic particles will be controlled by the ratio n/(the absolute value of B(sub 0)(exp 2). A variation of this ratio leads to a strong variation of the dynamics of the energetic particles. By taking into account the whole transverse plasma branch for the resonant interaction we discuss the influence of the background plasma density, the background magnetic field, the cross helicity, and the magnetic helicities on the dynamics of charged particles in astrophysical plasmas. It is shown that low-energy electrons can be accelerated efficiently by the higher electromagnetic waves and short-wavelength whistlers for low values of the ratio n/(the absolute value of B(sub 0)(exp 2), which means for low values of the ratio of plasma frequency to gyrofrequency.
Gateway will be an outpost in cislunar space designed to survive a 15-year mission to support human Moon landings and future deep space exploration. The Gateway Passive Thermal Control System (PTCS) Group has identified charged particle and UV degradation of potential Gateway materials as a knowledge gap for the Near Rectilinear Halo Orbit (NRHO) and transit environment, especially the slow spiral transit planned for the first two modules. Solar absorptivity degradation is important to quantify because the end-of-life absorptivity impacts thermal performance of the system. To address this, ground testing has been completed at NASA Goddard Space Flight Center in which potential Gateway materials, including radiators, multi-layer insulation (MLI), and structural materials are subjected to the expected transit plus 15-year on-orbit charged particle fluence (9.86x1015 protons/cm2 at 2.5 keV and 3.1x1016 electrons/cm2 at 10 keV) and 5093 Equivalent Solar Hours (ESH). Reflectivity of a single sample of each material was measured in atmosphere and in vacuum inside the chamber after exposure to incremental levels of ESH and charged particle fluence. Increase in absorptivity of most samples were seen throughout the test including large differences in absorptivity of materials of the same category. Future planned testing will validate these results and include additional materials of interest.
Graphs of Explorer XIV charged particle detectors responses
The L2 Charged Particle Environment (L2-CPE) model provides estimates of number flux and fluence for the low energy electron, proton, and alpha particle populations in the near Earth solar wind and the Earth’s distant magnetosheath and magnetotail. The model is an engineering tool for specifying radiation environments over an energy range from a few eV to a few MeV of importance to surface dose and radiation damage to thin space exposed materials and is intended for use in space system design applications. Mission fluences are obtained by simulating a spacecraft flight trajectory through time-dependent bow shock and magnetopause boundaries with dimensions and orientations driven by solar wind parameters. Monte Carlo sampling of flux environments within individual plasma regimes and/or fluence accumulated along a fight trajectory through multiple regimes is used to determine statistical variations (means and extremes) of the differential number flux and fluence environments for each of the three charged particle species. Model output is differential (in energy) number fluence and flux for the three particle species in units of particles/cm2-keV and particles/cm2-sec-keV, respectively. Users can select the energy range of interest but the current version of the code (L2-CPE Version 1.4.2d) is limited to an energy range of 1 eV to 10 MeV. Flux is integrated over angle to give flux and fluence to surfaces in the ±XGSE, ±YGSE, and/or ±ZGSE directions. Figure 1 shows the opening screen from the L2-CPE graphical user interface (GUI) with options for flux, fluence, plotting model output. The flux scene generate is not currently implemented in the GUI.
Fermi acceleration of charged particles in shock transition region beyond magnetosphere
Motion of charged particle in a slowly increasing magnetic field
First correction to second adiabatic invariant of charged particle motion in magnetic field
The charging and discharging characteristics of an electrically isolated solar array segment were studied in order to simulate discharges seen during geomagnetic substorms. A solar array segment was floated while bombarded with monoenergetic electrons at various angles of incidence. The potentials of the array surface and of the interconnects were monitored using Trek voltage probes to maintain electrical isolation. A back plate was capacitively coupled to the array to provide information on the characteristics of the transients accompanying the discharges. Several modes of discharging of the array were observed at relatively low differential and absolute potentials (a few kilovolts). A relatively slow discharge response in the array was observed, discharging over one second with currents of nanoamps. Two types of faster discharges were also seen which lasted a few hundredths of a millisecond and with currents on the order of microamps. Some results indicate an electron emission process associated with the arcs.
Fluctuations of energy loss by charged particles in lithium-drifted silicon semiconductor detectors
Gateway is a lunar orbiting platform that will be assembled in space similar to the International Space Station. Modules will arrive following different transit orbits, some of which have an extended duration in the Van Allen Belts. This means the spacecraft is exposed to significant charged particle radiation, after which it must operate in cislunar space for 15 years. Charged particle and UV degradation of potential Gateway materials was identified as a knowledge gap by the Passive Thermal Control System (PTCS) Group as end-of-life solar absorptivity greatly impacts thermal performance. Multiple rounds of ground testing have been completed at NASA Goddard Space Flight Center in which potential Gateway materials were subjected to expected worst-case transit charged particle fluence (9.86x1015 protons/cm2 at 2.5 keV and 3.1x1016 electrons/cm2 at 10 keV) and up to 5093 Equivalent Solar Hours (ESH) of UV exposure. This report builds on previous data from Zinecker et al. 2022 which presented the first round of ground testing. Additional materials have been tested and solar absorptivity degradation along with lessons learned are shared. Comparisons to previous results are also presented.
Gateway is a lunar orbiting platform that will be assembled in space similar to the International Space Station. Modules will arrive following different transit orbits, some of which have an extended duration in the Van Allen Belts. This means the spacecraft is exposed to significant charged particle radiation, after which it must operate in cislunar space for 15 years. Charged particle and UV degradation of potential Gateway materials was identified as a knowledge gap by the Passive Thermal Control System (PTCS) Group as end-of-life solar absorptivity greatly impacts thermal performance. Multiple rounds of ground testing have been completed at NASA Goddard Space Flight Center in which potential Gateway materials were subjected to expected worst-case transit charged particle fluence (9.86 x 10 15 protons/cm 2 at 2.5 keV and 3.1x10 16 electrons/cm 2 at 10 keV) and up to 5093 Equivalent Solar Hours (ESH) of UV exposure. This report builds on previous data from Zinecker et al. 2022. Round 1a was published in that paper and Rounds 2a, 2b, and 2c are discussed here with some comparisons to Round 1a. Additional materials have been tested and solar absorptivity degradation is presented along with comparisons to previous results.
The NASA MSFC Propulsion Research Center (PRC) is conducting a research activity examining the storage of low energy antiprotons. The High Performance Antiproton Trap (HiPAT) is an electromagnetic system (Penning-Malmberg design) consisting of a 4 Tesla superconductor, a high voltage confinement electrode system, and an ultra high vacuum test section; designed with an ultimate goal of maintaining charged particles with a half-life of 18 days. Currently, this system is being experimentally evaluated using normal matter ions which are cheap to produce and relatively easy to handle and provide a good indication of overall trap behavior, with the exception of assessing annihilation losses. Computational particle-in-cell plasma modeling using the XOOPIC code is supplementing the experiments. Differing electrode voltage configurations are employed to contain charged particles, typically using flat, modified flat and harmonic potential wells. Ion cloud oscillation frequencies are obtained experimentally by amplification of signals induced on the electrodes by the particle motions. XOOPIC simulations show that for given electrode voltage configurations, the calculated charged particle oscillation frequencies are close to experimental measurements. As a two-dimensional axisymmetric code, XOOPIC cannot model azimuthal plasma variations, such as those induced by radio-frequency (RF) modulation of the central quadrupole electrode in experiments designed to enhance ion cloud containment. However, XOOPIC can model analytically varying electric potential boundary conditions and particle velocity initial conditions. Application of these conditions produces ion cloud axial and radial oscillation frequency modes of interest in achieving the goal of optimizing HiPAT for reliable containment of antiprotons.
The linear energy transfer (LET) spectra of charged particles was measured in the 5 to 250 keV/micron (water) interval with CR-39 and in the 250 to 1000 keV/micron (water) interval with polycarbonate plastic nuclear track detectors (PNTDs) under different shielding depths in the P0006 experiment. The optimal processing conditions were determined for both PNTDs in relation to the relatively high track densities due to the long term exposure in space. The total track density was measured over the selected samples, and tracks in coincidence on the facing surfaces of two detector sheets were selected for measuring at the same position on each sheet. The Short Range (SR) and Galactic Cosmic Ray (GCR) components were measured separately. The integral dose and dose rate spectra of charged particles are also given. The high LET portion of the LET spectra was measured with high statistical accuracy. This is a unique result of this experiment due to the low flux of this type of particle under typical shielding conditions.
Low energy charged particle detection with continuous channel electron multiplier
Propagation of low energy charged particles in inner solar system
Statistical mechanics of charged particles in presence of magnetic irregularities
Elementary particle detection by high resolution cosmic ray charged particle telescope during three flights in summer of 1966