Search NASA⌕ Search

SEARCH · Search NASA

Results for “Circulating Water System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Measurements of natural circulation flow in a scale model PWR reactor system during postulated degraded core accidents using laser anemometry

The natural circulation of a single-phase fluid in a scale-model pressurized water reactor system was studied during a postulated degraded core accident. A half section of a one-seventh scale model with a plexiglass adiabatic window was employed. Water and SF6 were used as the fluid. LDA was used to perform velocity measurements along the center plane of the model at five elevations. It was found that the recirculation flow patterns are nearly symmetric except near the hot legs and in the upper head and that the fluid in the upper plenum is well mixed.

Kadambi, J. R.↗

Summary report on the Nimbus II satellite.

Nimbus 2 meteorological satellite observations, discussing circulation associated with synoptic scale systems obtained by correlating water vapor and carbon dioxide pictures

Nordberg, W.↗

On the Vertical Distribution of Local and Remote Sources of Water for Precipitation

The vertical distribution of local and remote sources of water for precipitation and total column water over the United States are evaluated in a general circulation model simulation. The Goddard Earth Observing System (GEOS) general circulation model (GCM) includes passive constituent tracers to determine the geographical sources of the water in the column. Results show that the local percentage of precipitable water and local percentage of precipitation can be very different. The transport of water vapor from remote oceanic sources at mid and upper levels is important to the total water in the column over the central United States, while the access of locally evaporated water in convective precipitation processes is important to the local precipitation ratio. This result resembles the conceptual formulation of the convective parameterization. However, the formulations of simple models of precipitation recycling include the assumption that the ratio of the local water in the column is equal to the ratio of the local precipitation. The present results demonstrate the uncertainty in that assumption, as locally evaporated water is more concentrated near the surface.

Bosilovich, Michael G.↗

Interpreting Precession-Driven δ O-18 Variability in the South Asian Monsoon Region

Speleothem records from the South Asian summer monsoon (SASM) region display variability in the ratio of O-18 and O-16 (δ O-18) in calcium carbonate at orbital frequencies. The dominant mode of variability in many of these records reflects cycles of precession. There are several potential explanations for why SASM speleothem records show a strong precession signal, including changes in temperature, precipitation, and circulation. Here we use an Earth system model with water isotope tracers and water-tagging capability to deconstruct the precession signal found in SASM speleothem records. Our results show that cycles of precession-eccentricity produce changes in SASM intensity that correlate with local temperature, precipitation, and δ O-18. However, neither the amount effect nor temperature differences are responsible for the majority of the SASM δ O-18 variability. Instead, changes in the relative moisture contributions from different source regions drive much of the SASM δ O-18 signal, with more nearby moisture sources during Northern Hemisphere summer at aphelion and more distant moisture sources during Northern Hemisphere summer at perihelion. Further, we find that evaporation amplifies the δ O-18 signal of soil water relative to that of precipitation, providing a better match with the SASM speleothem records. This work helps explain a significant portion of the long-term variability found in SASM speleothem records.

paleoclimate↗

Control rod drive mechanism with heat pipe cooling

A representative cooling system for a nuclear reactor control rod drive mechanism (CRDM) includes an evaporation section located within or next to the CRDM and a condensation section fluidly coupled to the evaporation section. The cooling system includes a set of heat fins coupled to drive coils in the CRDM and heat pipes that extend through the drive coils and heat fins. A fluid evaporates while in the evaporation section of the heat pipes from heat generated by the CRDM and moves out of the evaporation section into the condensation section in the heat fins. The fluid cools and condensates while in the condensation section, recirculating back into the evaporation section. This passive natural circulation cooling system reduces or eliminates the number of water hoses, piping, and other water pumping equipment typically used for cooling a CRDM thereby increasing nuclear reactor reliability and simplifying nuclear reactor operation and maintenance.

Lobscheid, Christian↗

System for Continuous Deaeration of Hydraulic Oil

A system for continuous, rapid deaeration of hydraulic oil has been built to replace a prior system that effected deaeration more slowly in a cyclic pressure/ vacuum process. Such systems are needed because (1) hydraulic oil has an affinity for air, typically containing between 10 and 15 volume percent of air and (2) in the original application for which these systems were built, there is a requirement to keep the proportion of dissolved air below 1 volume percent because a greater proportion can lead to pump cavitation and excessive softness in hydraulic-actuator force-versus-displacement characteristics. In addition to overcoming several deficiencies of the prior deaeration system, the present system removes water from the oil. The system (see figure) includes a pump that continuously circulates oil at a rate of 10 gal/min (38 L/min) between an 80-gal (303-L) airless reservoir and a tank containing a vacuum. When the circulation pump is started, oil is pumped, at a pressure of 120 psi (827 kPa), through a venturi tube below the tank with a connection to a stand-pipe in the tank. This action draws oil out of the tank via the standpipe. At the same time, oil is sprayed into the tank in a fine mist, thereby exposing a large amount of oil to the vacuum. When the oil level in the tank falls below the lower of two level switches, a vacuum pump is started, drawing a hard vacuum on the tank through a trap that collects any oil and water entrained in the airflow. When the oil level rises above higher of the two level switches or when the system is shut down, a solenoid valve between the tank and the vacuum pump is closed to prevent suction of oil into the vacuum pump. Critical requirements that the system is designed to satisfy include the following: 1) The circulation pump must have sufficient volume and pressure to operate the venturi tube and spray nozzles. 2) The venturi tube must be sized to empty the tank (except for the oil retained by the standpipe) and maintain a vacuum against the vacuum pump. 3) The tank must be strong enough to withstand atmospheric pressure against the vacuum inside and must have sufficient volume to enable exposure of a sufficiently large amount of sprayed oil to the vacuum. 4) The spray nozzles must be sized to atomize the oil and to ensure that the rate of flow of sprayed oil does not exceed the rate at which the venturi action can empty the tank. 5) The vacuum pump must produce a hard vacuum against the venturi tube and continue to work when it ingests some oil and water. 6) Fittings must be made vacuum tight (by use of O-rings) to prevent leakage of air into the system. The system is fully automatic, and can be allowed to remain in operation with very little monitoring. It is capable of reducing the air content of the oil from 11 to less than 1 volume percent in about 4 hours and to keep the water content below 100 parts per million.

Anderson, Christopher W.↗

Operation of a breadboard liquid-sorbent/membrane-contactor system for removing carbon dioxide and water vapor from air

Processes to remove and recover carbon dioxide (CO2) and water vapor from air are essential for successful long-duration space missions. This paper presents results of a developmental program focused on the use of a liquid-sorbent/membrane-contactor (LSMC) system for removal of CO2 and water vapor from air. In this system, air from the spacecraft cabin atmosphere is circulated through one side of a hollow-fiber membrane contactor. On the other side of the membrane contactor is flowed a liquid sorbent, which absorbs the CO2 and water vapor from the feed air. The liquid sorbent is then heated to desorb the CO2 and water vapor. The CO2 is subsequently removed from the system as a concentrated gas stream, whereas the water vapor is condensed, producing a water stream. A breadboard system based on this technology was designed and constructed. Tests showed that the LSMC breadboard system can produce a CO2 stream and a liquid-water stream. Details are presented on the operation of the system, as well as the effects on performance of variations in feed conditions.

Mccray, Scott B.↗

Lawrence Livermore National Laboratory (LLNL) Experimental Test Site (Site 300) Salinity Evaluation and Minimization Plan for Cooling Towers and Mechanical Equipment Discharges

This document was created to comply with the Central Valley Regional Water Quality Control Board (CVRWQCB) Waste Discharge Requirement (Order No. 98-148). This order established new requirements to assess the effect of and effort required to reduce salts in process water discharged to the subsurface. This includes the review of technical, operational, and management options available to reduce total dissolved solids (TDS) concentrations in cooling tower and mechanical equipment water discharges at Lawrence Livermore National Laboratory's (LLNL's) Experimental Test Site (Site 300) facility. It was observed that for the six cooling towers currently in operation, the total volume of groundwater used as make up water is about 27 gallons per minute and the discharge to the subsurface via percolation pits is 13 gallons per minute. The extracted groundwater has a TDS concentration of 700 mg/L. The cooling tower discharge concentrations range from 700 to 1,400 mg/L. There is also a small volume of mechanical equipment effluent being discharged to percolation pits, with a TDS range from 400 to 3,300 mg/L. The cooling towers and mechanical equipment are maintained and operated in a satisfactory manner. No major leaks were identified. Currently, there are no re-use options being employed. Several approaches known to reduce the blow down flow rate and/or TDS concentration being discharged to the percolation pits and septic systems were reviewed for technical feasibility and cost efficiency. These options range from efforts as simple as eliminating leaks to implementing advanced and innovative treatment methods. The various options considered, and their anticipated effect on water consumption, discharge volumes, and reduced concentrations are listed and compared in this report. Based on the assessment, it was recommended that there is enough variability in equipment usage, chemistry, flow rate, and discharge configurations that each discharge location at Site 300 should be considered separately when deciding on an approach for reducing the salt discharge to the subsurface. The smaller units may justify moderate changes to equipment, and may benefit from increased cleaning frequencies, more accurate and suitable chemical treatment, and sources of make up water and discharge re-use. The larger cooling towers would be more suitable for automated systems where they don't already exist, re-circulation and treatment of blow down water, and enhanced chemical dosing strategies. It may be more technically feasible and cost efficient for the smaller cooling towers to be replaced by closed loop dry coolers or hybrid towers. There are several potential steps that could be taken at each location to reduce the TDS concentration and/or water use. These include: sump water filtration, minimization of drift, accurate chemical dosing, and use of scale and corrosion coupons for chemical calibration. The implementation of some of these options could be achieved by a step-wise approach taken at two representative facilities. Once viable prototype systems have been proven in the field, systematic implementation should proceed for the remaining systems, with cost, desired reduction, and general feasibility taken into consideration for such systems.

54 ENVIRONMENTAL SCIENCES↗

Heat Pipe Systems

Solar Fundamentals, Inc.'s hot water system employs space-derived heat pipe technology. It is used by a meat packing plant to heat water for cleaning processing machinery. Unit is complete system with water heater, hot water storage, electrical controls and auxiliary components. Other than fans and a circulating pump, there are no moving parts. System's unique design eliminates problems of balancing, leaking, corroding, and freezing.

Source record↗

Southern Ocean polynyas and dense water formation in a high-resolution, coupled Earth system model

Antarctic coastal polynyas produce dense shelf water, a primary source of Antarctic Bottom Water that contributes to the global overturning circulation. This paper investigates Antarctic dense water formation in the high-resolution version of the Energy Exascale Earth System Model (E3SM-HR). The model is able to reproduce the main Antarctic coastal polynyas, although the polynyas are smaller in area compared to observations. E3SM-HR also simulates several occurrences of open-ocean polynyas (OOPs) in the Weddell Sea at a higher rate than what the last 50 years of the satellite sea ice observational record suggests, but similarly to other high-resolution Earth system model simulations. Furthermore, the densest water masses in the model are formed within the OOPs rather than on the continental shelf as is typically observed. Biases related to the lack of dense water formation on the continental shelf are associated with overly strong atmospheric polar easterlies, which lead to a strong Antarctic Slope Front and too little exchange between on- and off-continental shelf water masses. Strong polar easterlies also produce excessive southward Ekman transport, causing a build-up of sea ice over the continental shelf and enhanced ice melting in the summer season. This, in turn, produces water masses on the continental shelf that are overly fresh and less dense relative to observations. Our results indicate that high resolution alone is insufficient for models to properly reproduce Antarctic dense water; the large-scale polar atmospheric circulation around Antarctica must also be accurately simulated.

54 ENVIRONMENTAL SCIENCES↗

Experimental investigation on the flow instability behavior of a multi-channel boiling natural circulation loop at low-pressures

Natural circulation as a mode of heat removal is being considered as a prominent passive feature in the innovative nuclear reactor designs, particularly in boiling-water-reactors, due to its simplicity and economy. However, boiling natural circulation system poses many challenges to designer due to occurrence of various kinds of instabilities such as excursive instability, density wave oscillations, flow pattern transition instability, geysering and metastable states in parallel channels. This problem assumes greater significance particularly at low-pressures i.e. during startup, where there is great difference in the properties of two phases. In light of this, a parallel channel loop has been designed and installed that has a geometrical resemblance to the pressure-tube-type boiling-water-reactor, to investigate into the behavior of boiling natural circulation. The loop comprises of four identical parallel channels connected between two common plenums i.e. steam drum and header. The recirculation path is provided by a single downcomer connected between steam drum and header. Experiments have been conducted over a wide range of power and pressures (1-10 bar). Two distinct unstable zones are observed with respect to power i.e. corresponding to low power (Type-I) and high power (Type-II) with a stable zone at intermediate powers. The nature of oscillations in terms of their amplitude and frequency and their evolution for Type-I and Type-II instabilities are studied with respect to the effect of heater power and pressure. This paper discusses the evolution of unstable and stable behavior along with the nature of flow oscillation in the channels and the effect of pressure on it. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Simultaneous lidar profiling of water vapor, aerosol, and wind over the eastern Pacific and implications for observational challenges on clouds, circulation, and climate sensitivity

Moist convective processes and related circulations are key components of the Earth’s climate system. Improving our understanding of moisture and cloud processes over oceans is especially challenging due to observational limitations, but also important due to the large radiative effects of cloud over ocean as well as the ties to local and global-scale circulations. A unique dataset for addressing these topics was collected over 5 flights with the NASA HALO (water vapor DIAL and aerosol HSRL) and DAWN (Doppler wind) lidar systems onboard the NASA DC-8 aircraft during the spring 2019 ADM-Aeolus Cal/Val test flight campaign. High-resolution water vapor, aerosol/cloud, and wind profiles were simultaneously collected and complimented with in situ high-resolution dropsonde measurements of temperature, relative humidity, and wind profiles. Airborne lidar measurements of these key variables captured both large-scale spatial variability across different cloud and atmospheric conditions as well as finer features, providing insight into processes from large-scale circulations down to aerosol/cloud interactions. The 5 flights spanned the northeast Pacific and southwest U.S. from 6 N to 52 N and 112 W to 157 W and captured several features of interest including moist layers from the ascending region of the Hadley circulation, very dry layers above midlatitude marine stratocumulus and cloud-free planetary boundary layers, and cloud top height and spatial variability. High covariance of aerosol and water vapor in the free troposphere was also observed for the first time. Preliminary analysis of these data sets will be presented as they apply to clouds and circulations, supplemented by model reanalysis to inform how regional water vapor structure and large-scale motion may contribute to observed shallow cloud formations and other meteorological processes that underpin our current understanding of how these state variables couple to impact the Earth’s weather and climate systems. The potential of complementary measurements in future field campaigns will also be mentioned.

Brian James Carroll↗

Ocean-Science Mission Needs: Real-Time AUV Data for Command, Control, and Model Inputs

Predictive models for tides, hydrodynamics, and bio-optical properties affecting the visibility and buoyancy of coastal waters are needed to evaluate the safety of personnel and equipment engaged in maritime operations under potentially hazardous conditions. Predicted currents can be markedly different for two-layer systems affected by terrestrial runoff than for well-mixed conditions because the layering decouples the surface and bottom Ekman layers and rectifies the current response to oscillatory upwelling-and downwelling-favorable winds. Standard ocean models (e.g. Princeton Ocean Model) require initial-and boundary data on the physical and optical properties of the multilayered water column to provide accurate simulations of heat budgets and circulation. Two observational systems are designed to measure vertically structured conditions on the West Florida Shelf (WFS): a tethered buoy network and an autonomous underwater vehicle (AUV) observational system. The AUV system is described with a focus on the observational systems that challenge or limit the communications command and control network for various types of measurement programs. These include vertical oscillatory missions on shelf transects to observe the optical and hydrographic properties of the water column, and bottom-following missions for measuring the bottom albedo. Models of light propagation, absorption, and conversion to heat as well as determination of the buoyancy terms for physical models require these measurements. High data rates associated with video bottom imagery are the most challenging for the real-time, command and control communications system, but they are met through a combination of loss-less and lossy data-compression methods, depending upon the data-rate of the radio links.

Carder, Kendall L.↗

DNC Simulation Results and Risk Assessment

The performance of Dynamic Natural Circulation (DNC) systems during a station blackout in a pressurizer water reactor was evaluated. Thermal-hydraulic calculations of a PWR with passive DNC systems were performed using RELAP5-3D. The effects of the DNC systems on the cumulative core damage frequency during a station blackout was evaluated using probabilistic and risk assessment methods.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Solar heating and hot water system installed at office building, One Solar Place, Dallas, Texas

A solar heating on cooling system is described which is designed to provide 87 percent of the space heating needs, 100 percent of the potable hot water needs and is sized for future absorption cooling. The collection subsystem consists of 28 solargenics, series 76, flat plate collectors with a total area of 1,596 square feet. The solar loop circulates an ethylene glyco water solution through the collectors into a hot water system exchanger. The water storage subsystem consists of a heat exchanger, two 2,300 gallon concrete hot water storage tanks with built in heat exchangers and a back-up electric boiler. The domestic hot water subsystem sends hot water to the 10,200 square feet floor area office building hot water water fixtures. The building cold water system provides make up to the solar loop, the heating loop, and the hot water concrete storage tanks. The design, construction, cost analysis, operation and maintenance of the solar system are described.

Source record↗

Two-phase flow measurements and observations in a cooling panel of the reactor cavity cooling system

The analysis of the flow behavior within a cooling panel of a scaled water-cooled reactor cavity cooling system has been performed supported by high-resolution measurements of the void fraction at the risers’ outlet. The results have shown a stable, symmetric distribution of the flow through the risers during subcooled boiling conditions, characterized by small, slow bubbles with average void fraction lower than 0.3 for all risers. As the temperature increased to saturation, flow distribution appeared strongly asymmetrical and unstable, with peaks of void fraction as high as 0.9. Large, faster bubbles were observed during these peaks, immediately followed by flow of subcooled liquid water. Flow stagnation and inversion has also been observed. The high resolution void fraction results, complemented by the measurements of the coolant flow rate and temperatures, not only have further described the behavior of the system under hypothetical accident conditions, but represent a unique set of data to support the validation of system-level codes, and more advanced computational tools.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Numerical Study of Hypoxia in Chesapeake Bay Using an Unstructured Grid Model: Validation and Sensitivity to Bathymetry Representation

A three-dimensional unstructured-grid hydrodynamic and water quality model (Semi-implicit Cross-scale Hydroscience Intergrated System Model-Integrated Compartment Model) is applied successfully for Chesapeake Bay. The model is validated with observations of salinity, chlorophyll-a, dissolved oxygen, nutrients, and phytoplankton productions from the year 1991 to 1995 for the mainstem and some major tributaries, based on multiple model skill scores. Model experiments are conducted to test the importance of having (1) an accurate representation of bathymetry to correctly predict hypoxia and other processes and (2) a high-resolution model grid for tributaries to correctly simulate water quality variables. Further, comparison with the model experiment results with bathymetry smoothing indicates that bathymetry smoothing, as commonly used for many systems, changes the stratification and lateral circulation pattern, resulting in more salt intrusion into shallow water regions, and an increase in the freshwater age. Consequently, a model with bathymetry smoothing can lead to an unrealistic prediction of the distribution of hypoxia and phytoplankton production. Local grid refinement shows significant improvement of model simulations on local stratification and water quality variables. Overall, the use of high-resolution unstructured grid model leads to a faithful representation of the complex geometry, and thus a seamless cross-scale capability for simulating water quality processes in the Bay including tributaries and tidal creeks.

54 ENVIRONMENTAL SCIENCES↗

Effect of Glacial/Interglacial Recharge Conditions on Flow of Meteoric Water Through Deep Orogenic Faults: Insights Into the Geothermal System at Grimsel Pass, Switzerland

Many meteoric-recharged, fault-hosted geothermal systems in amagmatic orogenic belts have been active through the Pleistocene glacial/interglacial climate fluctuations. The effects of such climate-induced recharge variations on fluid flow patterns and residence times of the thermal waters are complex and may influence how the geothermal and mineralization potential of the systems are evaluated. We report systematic thermal–hydraulic simulations designed to reveal the effects of recharge variations, using a model patterned on the orogenic geothermal system at Grimsel Pass in the Swiss Alps. Fault-bound circulation of meteoric water through the Grimsel fault is driven to depths of ~10 km by the high alpine topography. Simulations suggest that the current single pass flow is typical of interglacial periods, during which 1) meteoric recharge into the fault is high (above tens of centimeters per year), 2) conditions are at or somewhat below the critical Rayleigh number, and 3) the hydraulic connectivity along the fault plane is extensive (an extent of at least 10 km into increasingly higher terrain is required to explain the 10 km penetration depth). The subcritical condition constrains the bulk fault permeability to < 1e-14 m2. In contrast, the limited recharge during the numerous Pleistocene glaciation events likely induced a layered flow system with single pass flow confined to shallow depths while non-Rayleigh convection occurred in the deep fault. The same layering can be observed at low aspect ratios (length/depth) of the fault plane, when the available recharge area limits the flux through the fault.

58 GEOSCIENCES↗